1.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
2.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
3.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.A novel anti-ischemic stroke candidate drug AAPB with dual effects of neuroprotection and cerebral blood flow improvement.
Jianbing WU ; Duorui JI ; Weijie JIAO ; Jian JIA ; Jiayi ZHU ; Taijun HANG ; Xijing CHEN ; Yang DING ; Yuwen XU ; Xinglong CHANG ; Liang LI ; Qiu LIU ; Yumei CAO ; Yan ZHONG ; Xia SUN ; Qingming GUO ; Tuanjie WANG ; Zhenzhong WANG ; Ya LING ; Wei XIAO ; Zhangjian HUANG ; Yihua ZHANG
Acta Pharmaceutica Sinica B 2025;15(2):1070-1083
Ischemic stroke (IS) is a globally life-threatening disease. Presently, few therapeutic medicines are available for treating IS, and rt-PA is the only drug approved by the US Food and Drug Administration (FDA) in the US. In fact, many agents showing excellent neuroprotection but no blood flow-improving activity in animals have not achieved ideal clinical efficacy, while thrombolytic drugs only improving blood flow without neuroprotection have limited their wider application. To address these challenges and meet the huge unmet clinical need, we have designed and identified a novel compound AAPB with dual effects of neuroprotection and cerebral blood flow improvement. AAPB significantly reduced cerebral infarction and neural function deficit in tMCAO rats, pMCAO rats, and IS rhesus monkeys, as well as displayed exceptional safety profiles and excellent pharmacokinetic properties in rats and dogs. AAPB has now entered phase I of clinical trials fighting IS in China.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Research and application of a new deep learning based strategy for platelet histogram review
Enming ZHANG ; Chao YANG ; Xianchun CHEN ; Yan LIN ; Taixue AN ; Haixia LI ; Yongjian HE ; Zhiwei LIU ; Limei FENG ; Wanying LIN ; Tie XIONG ; Kai QIU ; Ya GAO ; Lizhu HUANG ; Jing HE ; Chunyan WANG ; Dehua SUN ; Bo SITU ; Lei ZHENG
Chinese Journal of Laboratory Medicine 2025;48(9):1201-1206
Objective:To develop an artificial intelligence (AI)-based platelet review strategy to identify abnormal platelet histograms with no significant difference between initial impedance platelet count (PLT-I) and PLT-F results.Methods:This study included 5 119 routine blood analysis in Nanfang Hospital of Southern Medical University and its Ganzhou branch from July 2023 and March 2024. Specimens exhibiting abnormal platelet histograms and an initial platelet count >40×10?/L underwent review using the fluorescent platelet count (PLT-F) channel. Consistency of the results was defined as a difference between impedance platelet count (PLT-I) and PLT-F less than ±20% of the PLT-F results. A deep learning model was developed using platelet and red blood cell histogram data from a training set of 3 807 specimens. The model′s diagnostic performance was evaluated on an independent external validation set ( n=805) using receiver operating characteristic (ROC) curve analysis. Changes in the number of reviewed samples and sample turnaround time were analyzed to assess its clinical utility. Results:The deep learning model based on platelet and red blood cell histograms achieved an area under the ROC curve (AUC) of 0.854 in the training set. At a cutoff value of 0.1, the sensitivity was 0.954 and specificity was 0.358. The model could reduce review by 16.80% (190/1 131). In the validation set, the AUC was 0.805, with a sensitivity of 0.955 and specificity of 0.307, corresponding to a reduction of 17.41% (47/270) in reviewed specimens.Conclusion:The platelet review prediction model developed based on deep learning technology can efficiently identify samples with consistent results before and after review, reducing unnecessary reviews and shortening specimen testing time, thereby improving the efficiency of platelet test.

Result Analysis
Print
Save
E-mail