1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Design, synthesis and evaluation of oxadiazoles as novel XO inhibitors
Hong-zhan WANG ; Ya-jun YANG ; Ying YANG ; Fei YE ; Jin-ying TIAN ; Chuan-ming ZHANG ; Zhi-yan XIAO
Acta Pharmaceutica Sinica 2025;60(1):164-171
Xanthine oxidase (XO) is an important therapeutic target for the treatment of hyperuricemia and gout. Based on the previously identified potent XO inhibitor
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
7.Correlation of knee joint asymmetry with balance and walking ability in hemiplegic stroke patients
Zheng-Hua XIAO ; Jiang MA ; Hong LI ; Fang WANG ; Li-Ying GUO ; Xiao-Lin TAO ; Feng ZHANG ; Ya-Yong LI ; Xiao-Li YAN
Medical Journal of Chinese People's Liberation Army 2025;50(2):134-140
Objective To explore the correlation of bilateral knee joint strength asymmetry with balance,walking ability,and motor function in hemiplegic stroke patients,providing a reference for clinical assessment of stroke patients.Methods A total of 46 hemiplegic stroke patients admitted to the Rehabilitation Medicine Department of People's Hospital of Shijiazhuang from February to December 2023 were selected.According to the Berg Balance Scale(BBS)scores,patients were divided into Group A(BBS score≤20,n=23)and Group B(BBS score>20,n=23).The peak torque and differences of bilateral knee flexors and extensors were compared between two groups.Isokinetic technology was used to assess the differences in peak torque of bilateral knee joints at 60°/s and 120°/s.BBS,Functional Ambulation Classification(FAC),and Fugl-Meyer Assessment of Lower Extremity(FMA-LE)were used to evaluate patients'balance,walking ability,and lower limb motor function.The correlation between bilateral knee joint peak torque and its difference with the scores of three functional scales was analyzed.Results The peak torque of knee flexors and extensors at 60°/s in group A was significantly lower than that in group B(P<0.05).At both 60°/s and 120°/s the differences in peak torque between the healthy and affected sides of knee flexors and extensors were greater than those in group B(P<0.05).At 60°/s,the difference in peak torque of bilateral knee extensors in hemiplegic stroke patients was negatively correlated with the scores of BBS,FAC,and FMA-LE(r=-0.569,-0.582,-0.606,P<0.01),as did the knee flexors(r=-0.534,-0.386,-0.458,P<0.05).At 120°/s,similar negative correlations were observed for both knee extensors(r=-0.304,-0.304,-0.443,P<0.05)and flexors(r=-0.337,-0.349,-0.370,P<0.05).Conclusions Bilateral knee joint strength asymmetry in hemiplegic stroke patients is negatively correlated with balance and walking ability.The difference in strength between the two sides of knee joint may be one of the clinical indicators for evaluating the motor function of stroke patients.
8.Effect of Chaihuang Qingyi Huoxue Granules on multiple organ damage induced by cerulein combined with lipopolysaccharide in mice with severe acute pancreatitis
Jian-Qin LIU ; Hong-Lian WANG ; Li LI ; Zhi LI ; Ya-Li LIU ; Xin ZHOU
Medical Journal of Chinese People's Liberation Army 2025;50(7):876-881
Objective To investigate the effects of Chaihuang Qingyi Huoxue Granules on multiple organ damage induced by caerulein combined with lipopolysaccharide in mice with severe acute pancreatitis(SAP).Methods Twenty-four C57BL/6J mice were randomly divided into three groups:control(n=8),SAP(n=8)and Chaihuang Qingyi Huoxue Granules(CHQY group,n=8).Mice in SAP and CHQY groups were intraperitoneally injected with caerulein(50 μg/kg)at hourly intervals for 7 consecutive times,followed by an immediate intraperitoneal injection of lipopolysaccharide(10 mg/kg).Mice in control group received an equal volume of normal saline.After the successful establishment of the model,CHQY group mice were administered Chaihuang Qingyi Huoxue Granules[3.185 g/(kg·d)]via gavage,while control and SAP group mice received an equal volume of normal saline.Twenty-four hours post-modeling,mice were anesthetized,and serum was collected and separated for analysis of the activities of amylase(AMY),lipase(LPS),aspartate transaminase(AST),alanine transaminase(ALT)and the contents of creatinine(CREA)and urea(UREA)using an automatic biochemical analyzer.Serum levels of interleukin(IL)-1β,IL-6,IL-8,IL-18,and tumor necrosis factor-α(TNF-α)were measured by ELISA.Tissue samples from pancreas,lung,liver,kidney,and small intestine were collected for histopathological examination using hematoxylin-eosin(HE)staining and scored.The expression of nuclear factor-κB p65(NF-κB p65)was detected in all tissues by immunohistochemistry.Results Compared with control group,the activities of AMY,LPS,AST and ALT,and the contents of CREA,UREA,IL-1β,IL-6,IL-8,IL-18,and TNF-α were increased(P<0.05).Pathological injuries in the pancreas,lung,liver,kidney,and small intestine was significant,with increased pathological scores and a higher proportion of NF-κB p65 positive cells(P<0.05).Compared with SAP group,the activities of AMY,LPS,AST,ALT,and the contents of CREA,UREA,IL-1β,IL-6,IL-8,IL-18,and TNF-α in the serum of CHQY group were decreased(P<0.05).Pathological injuries in the pancreas,lung,liver,kidney and small intestine were reduced,with lower pathological scores and a decreased proportion of NF-κB p65 positive cells(P<0.05).Conclusion Chaihuang Qingyi Huoxue Granules have a certain therapeutic effect on SAP model mice,which may be related to reducing inflammation response and improving multiple organ damage such as the pancreas,lung,liver,kidney and small intestine.
9.Research progress on decidual natural killer cell education in recurrent pregnancy loss
Ya-Jing LI ; Yu-Jing XIONG ; Jie DONG ; Xiao-Hong WANG
Medical Journal of Chinese People's Liberation Army 2025;50(10):1332-1337
Decidual natural killer(dNK)cells are the most abundant immune cells in the decidua.The functional acquisition during dNK cell development depends on NK cell education,a process in which the highly polymorphic killer cell immunoglobulin-like receptors(KIRs)and CD94/NKG2s expressed on dNK cells bind to major histocompatibility complex(MHC)class Ⅰmolecules expressed by extravillous trophoblast(EVT)cells.This interaction regulates the effector functions of NK cells.dNK cells participate in the establishment and maintenance of pregnancy by modulating immune tolerance at the maternal-fetal interface.Defects in dNK cell education leading to dNK dysfunction are potential pathological mechanisms underlying adverse pregnancy outcomes such as recurrent pregnancy loss(RPL).This review summarizes the characteristics of dNK cells,dNK cell education and its key associated molecules,and the pathological mechanisms by which poorly educated dNK cells contribute to RPL,aiming to offer insights for predicting and improving pregnancy outcomes in RPL patients associated with dNK cell abnormalities.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.