1.Effects of bioactive peptides combined with probiotics on serum uric acid in patients with hyperuricemia
HAN Dan ; ZHAO Ya ; HUANG Enshan ; YE Shuhua ; WANG Wanjin ; WU Fangmin ; WANG Dingliang ; ZHANG Ronghua
Journal of Preventive Medicine 2025;37(1):40-45
Objective:
To evaluate the effect of bioactive peptides combined with probiotics on serum uric acid (SUA) in patients with hyperuricemia (HUA), so as to provide the evidence for prevention and treatment of HUA.
Methods:
The patients with HUA aged 18 to 65 years were selected and randomly divided into an intervention group and a control group. The patients in the intervention group received bioactive peptides combined with probiotics for 28 days at a dose of 3 g/d, while the patients in the control group received an equal dose of placebos. Demographic information, body mass index (BMI), blood pressure and blood lipid were collected through questionnaire surveys, physical examination and laboratory tests. SUA levels were detected before and after 14 days and 28 days of interventions. The differences of SUA levels between the two groups were compared using generalized estimation equation.
Results:
Totally 108 patients with HUA were recruited, including 54 patients in the intervention group and 53 patients in the control group (1 dropout). Before interventions, there were no statistically significant differences in gender, age, course of HUA, exercise duration, frequency of alcohol consumption, frequency of meat broth consumption, BMI, prevalence of hypertension and prevalence of dyslipidemia between the two groups (all P>0.05). After 14 days of interventions, the SUA levels of the patients in the intervention group decreased by 3.00 μmol/L, while those in the control group increased by 7.00 μmol/L. After 28 days of interventions, the SUA levels of the patients in the intervention group and the control group decreased by 26.00 μmol/L and 16.00 μmol/L, respectively. However, there was no statistically significant interaction between the intervention time and group (both P>0.05). Subgroup analysis showed that after 28 days of interventions, the decrease in SUA levels in the patients aged 55 years and older and without hypertension in the intervention group was greater than those in the control group (both P<0.05).
Conclusions
Bioactive peptides combined with probiotics showed no significant difference in reducing SUA levels in patients with HUA compared to the control group. The effect was more significant for patients aged 55 years and older and without hypertension.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Guiding significance of intra-articular sagittal reduction in the treatment of tibial plateau fractures.
Jia-Fan ZHANG ; An-Hua LONG ; Da-Cheng HAN ; Zi-Chao JIA ; Ya-Kui ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(1):100-104
Tibial plateau fracture is a fracture involving the proximal articular surface of the tibia, and its injury mechanism is complex, the fracture morphology is different, and it is often accompanied by different degrees of soft tissue injury, which is difficult to diagnose and treat. In recent years, the research hotspot has focused on solving the reduction and fixation of the posterior lateral column of the tibial plateau, because it has been clinically found that the residual sagittal plane after tibial plateau fracture is insufficient reduction or loss of reduction leads to knee joint dysfunction. The posterior inclination angle of the tibial plateau is an important parameter to describe the sagittal alignment of the tibia. In the natural state, the posterior tibial slope(PTS) is altered to involve the soft tissues around the knee joint such as anterior cruciate ligament(ACL) and posterior cruciate ligament(PCL), which affects the stability of the knee joint. In total knee arthroplasty(TKA), choosing the appropriate PTS can effectively increase the prosthesis survival rate, improve the flexion and extension knee efficacy, which is beneficial to knee joint stability. In the field of orthopedic trauma, correction of sagittal deformity is equally important, following the principle of "reverse mechanism of injury". Quantitative evaluation of postoperative sagittal realignment of tibial plateau fractures and investigation of the effect of sagittal realignment on long-term outcomes and complications are still poorly understood and require further clinical and biomechanical studies.
Humans
;
Tibial Fractures/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Tibial Plateau Fractures
8.Preliminary efficacy and safety of a dose-intensified C5VD regimen in 24 children with locally advanced hepatoblastoma.
Jia-Xin PENG ; Can HUANG ; An-An ZHANG ; Ya-Li HAN ; Hai-Shan RUAN ; Xiao-Xia WANG ; Min XU ; Yuan XIN ; Li-Ting YU ; Zhi-Bao LYU ; Sha-Yi JIANG ; Yi-Jin GAO
Chinese Journal of Contemporary Pediatrics 2025;27(10):1247-1252
OBJECTIVES:
To assess the preliminary efficacy and safety of a dose-intensified C5VD regimen (cisplatin, 5-fluorouracil, vincristine, and doxorubicin) in children with locally advanced hepatoblastoma.
METHODS:
This prospective study enrolled 24 children with newly diagnosed, locally advanced hepatoblastoma who received the dose-intensified C5VD regimen at Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, and Shanghai Children's Hospital between January 2020 and December 2023. Clinical characteristics, treatment outcomes, and chemotherapy-related toxicities were analyzed.
RESULTS:
Of the 24 patients, 13 were male and 11 were female, with a median age at diagnosis of 18.7 months (range: 3.5-79.4 months). All patients achieved complete macroscopic resection of hepatic lesions without liver transplantation. Serum alpha-fetoprotein levels decreased significantly after two chemotherapy cycles. During a median follow-up of 38.4 months (range: 15.8-50.7 months), all patients maintained continuous complete remission, with 3-year event-free survival and overall survival rates of 100%. Across 144 chemotherapy cycles, the incidence rates of grade 3-4 neutropenia, thrombocytopenia, and infections were 97%, 77%, and 71%, respectively; no treatment-related deaths occurred. Notably, 5 patients (21%) developed Brock grade ≥3 hearing loss, of whom 1 required a hearing aid.
CONCLUSIONS
The dose-intensified C5VD regimen demonstrates significant efficacy with an overall favorable safety profile in the treatment of newly diagnosed, locally advanced pediatric hepatoblastoma. Grade 3-4 myelosuppression and infection are the predominant toxicities. However, high‑dose cisplatin-induced ototoxicity remains a concern, highlighting the need for improved otoprotective strategies.
Humans
;
Hepatoblastoma/pathology*
;
Male
;
Female
;
Infant
;
Liver Neoplasms/pathology*
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Child, Preschool
;
Prospective Studies
;
Doxorubicin/adverse effects*
;
Child
;
Cisplatin/adverse effects*
;
Vincristine/adverse effects*
;
Fluorouracil/adverse effects*
10.Dorsal CA1 NECTIN3 Reduction Mediates Early-Life Stress-Induced Object Recognition Memory Deficits in Adolescent Female Mice.
Yu-Nu MA ; Chen-Chen ZHANG ; Ya-Xin SUN ; Xiao LIU ; Xue-Xin LI ; Han WANG ; Ting WANG ; Xiao-Dong WANG ; Yun-Ai SU ; Ji-Tao LI ; Tian-Mei SI
Neuroscience Bulletin 2025;41(2):243-260
Early-life stress (ES) leads to cognitive dysfunction in female adolescents, but the underlying neural mechanisms remain elusive. Recent evidence suggests that the cell adhesion molecules NECTIN1 and NECTIN3 play a role in cognition and ES-related cognitive deficits in male rodents. In this study, we aimed to investigate whether and how nectins contribute to ES-induced cognitive dysfunction in female adolescents. Applying the well-established limited bedding and nesting material paradigm, we found that ES impairs recognition memory, suppresses prefrontal NECTIN1 and hippocampal NECTIN3 expression, and upregulates corticotropin-releasing hormone (Crh) and its receptor 1 (Crhr1) mRNA levels in the hippocampus of adolescent female mice. Genetic experiments revealed that the reduction of dorsal CA1 (dCA1) NECTIN3 mediates ES-induced object recognition memory deficits, as knocking down dCA1 NECTIN3 impaired animals' performance in the novel object recognition task, while overexpression of dCA1 NECTIN3 successfully reversed the ES-induced deficits. Notably, prefrontal NECTIN1 knockdown did not result in significant cognitive impairments. Furthermore, acute systemic administration of antalarmin, a CRHR1 antagonist, upregulated hippocampal NECTIN3 levels and rescued object and spatial memory deficits in stressed mice. Our findings underscore the critical role of dCA1 NECTIN3 in mediating ES-induced object recognition memory deficits in adolescent female mice, highlighting it as a potential therapeutic target for stress-related psychiatric disorders in women.
Animals
;
Female
;
Mice
;
CA1 Region, Hippocampal/metabolism*
;
Cell Adhesion Molecules/metabolism*
;
CRF Receptor, Type 1/metabolism*
;
Memory Disorders/etiology*
;
Mice, Inbred C57BL
;
Nectins/genetics*
;
Receptors, Corticotropin-Releasing Hormone/antagonists & inhibitors*
;
Recognition, Psychology/physiology*
;
Stress, Psychological/complications*


Result Analysis
Print
Save
E-mail