1.Perioperative digital surveillance with a multiparameter vital signs monitoring system in a gastric cancer patient with diabetes.
Reziya AIERKEN ; Z W JIANG ; G W GONG ; P LI ; X Y LIU ; F JI
Chinese Journal of Gastrointestinal Surgery 2025;28(11):1318-1322
Objective: To evaluate the application value of a digital technology-based multiparameter vital signs monitoring system in perioperative comprehensive full-cycle surveillance. Methods: A comprehensive multidimensional vital signs monitoring system was developed through the integration of medical-grade wireless wearable devices, incorporating patch-type ambulatory electrocardiographic monitor, continuous glucose monitoring sensor, pulse oximeter, wireless digital thermometer, smart wristband, and bioelectrical impedance analyzer. This system facilitates continuous real-time acquisition of multiple physiological parameters including electrocardiogram, blood glucose, oxygen saturation, body temperature, physical activity, and body composition indices. The acquired data were systematically integrated and analyzed through a four-level digital architecture consisting of nurse mobile interfaces, bedside patient terminals, centralized ward monitoring displays, and hospital management information systems. One patient with gastric cancer complicated by diabetes mellitus was selected for full-cycle digital monitoring from preoperative evaluation to hospital discharge. The technical performance of the monitoring system was assessed in terms of data acquisition continuity and timeliness of abnormal event alerts. Results: The monitoring system effectively identified early postoperative abnormalities, such as decreased oxygen saturation and blood glucose fluctuations, providing timely guidance for clinical intervention. The built-in algorithm enabled visualization of perioperative stress levels through heart rate variability indices and continuous glucose monitoring data. The patient demonstrated good compliance with early postoperative mobilization, and the satisfaction score for monitoring management was 4 points based on the Likert 5-point scale. Conclusions: The multiparameter vital signs monitoring system enhanced the precision of perioperative management through continuous and dynamic physiological status assessment. Its modular design aligns with the principles of enhanced recovery after surgery, offering a novel technological solution for intelligent perioperative management.
Humans
;
Stomach Neoplasms/physiopathology*
;
Vital Signs
;
Monitoring, Physiologic/instrumentation*
;
Diabetes Mellitus
;
Wearable Electronic Devices
;
Perioperative Period
2.2021 Asian Pacific Society of Cardiology Consensus Recommendations on the use of P2Y12 receptor antagonists in the Asia-Pacific Region: Special populations.
W E I C H I E H T A N TAN ; P C H E W CHEW ; L A M T S U I TSUI ; T A N TAN ; D U P L Y A K O V DUPLYAKOV ; H A M M O U D E H HAMMOUDEH ; Bo ZHANG ; Yi LI ; Kai XU ; J O N G ONG ; Doni FIRMAN ; G A M R A GAMRA ; A L M A H M E E D ALMAHMEED ; D A L A L DALAL ; T A N TAN ; S T E G STEG ; N N G U Y E N NGUYEN ; A K O AKO ; A L S U W A I D I SUWAIDI ; C H A N CHAN ; S O B H Y SOBHY ; S H E H A B SHEHAB ; B U D D H A R I BUDDHARI ; Zu Lv WANG ; Y E A N Y I P F O N G FONG ; K A R A D A G KARADAG ; K I M KIM ; B A B E R BABER ; T A N G C H I N CHIN ; Ya Ling HAN
Chinese Journal of Cardiology 2023;51(1):19-31
5.Radiation-associated sarcomas of bone and soft tissue: a clinicopathological analysis of 46 cases.
L H GONG ; W F LIU ; L LI ; X Q SUN ; M ZHANG ; Y DING
Chinese Journal of Pathology 2023;52(10):995-1000
Objective: To investigate the clinical, imaging, histological, and molecular features and the differential diagnosis of radiation-associated sarcomas of bone and soft tissue. Methods: Forty-six cases of radiation-associated sarcomas of the bone and soft tissue in Beijing Jishuitan Hospital from January 2010 to January 2022 were retrospectively analyzed; and the imaging, histological features and immunophenotype were examined. Results: There were 33 females and 13 males, aged from 18 to 74 years, with a mean of 52 years. The most common site of radiation-associated sarcomas were the limbs and spine (15 cases), followed by the chest (9 cases). The primary diseases included epithelial tumors (15 breast cancer, 6 cervical cancer, and 5 bowel cancer), hematolymphoid tumors, bone and soft tissue tumors and infectious lesions. The latent period of radiation-associated sarcomas ranged from 2-22 years, with an average of 11.6 years. Histopathologically, the morphology was divergent from the primary tumor. The most common malignant tumor type was undifferentiated sarcoma (22 cases), followed by osteosarcoma (16 cases). The immunophenotype of radiation-related sarcoma was almost the same as the corresponding soft tissue sarcoma. Conclusions: Radiation-induced sarcoma has a wide range of primary tumor types and its imaging, morphology and immunohistochemical features are similar to those of the primary sarcoma of bone and soft tissue. Clinical correlation is often recommended for the differential diagnosis.
Male
;
Female
;
Humans
;
Retrospective Studies
;
Sarcoma/pathology*
;
Osteosarcoma/diagnostic imaging*
;
Soft Tissue Neoplasms/pathology*
;
Bone Neoplasms/pathology*
6.Glomuvenous malformation: a clinicopathological analysis of 31 cases.
Q Y LIU ; W J BAO ; C X LI ; S XUE ; Y Z DING ; D K LIU ; B X MA ; F F FU ; L F KONG
Chinese Journal of Pathology 2023;52(10):1001-1005
Objective: To investigate the clinicopathological features of glomuvenous malformation (GVM). Methods: Thirty-one cases of GVM diagnosed at the Henan Provincial People's Hospital from January 2011 to December 2021 were collected. Their clinical and pathological features were analyzed. The expression of relevant markers was examined using immunohistochemistry. The patients were also followed up. Results: There were 16 males and 15 females in this study, with an average age of 11 years (range, 1-52 years). The locations of the disease included 13 cases in the limbs (8 cases in the upper limbs, 5 cases in the lower limbs), 9 cases in the trunks, and 9 cases in the foot (toes or subungual area). Twenty-seven of the cases were solitary and 4 were multifocal. The lesions were characterized by blue-purple papules or plaques on the skin surface, which grew slowly. The lumps became larger and appeared to be conspicuous. Microscopically, GVM mainly involved the dermis and subcutaneous tissue, with an overall ill-defined border. There were scattered or clustered irregular dilated vein-like lumens, with thin walls and various sizes. A single or multiple layers of relatively uniform cubic/glomus cells were present at the abnormal wall, with scattered small nests of the glomus cells. The endothelial cells in the wall of abnormal lumen were flat or absent. Immunohistochemistry showed that glomus cells strongly expressed SMA, h-caldesmon, and collagen IV. Malformed vascular endothelial cells expressed CD31, CD34 and ERG. No postoperative recurrence was found in the 12 cases. Conclusions: GVM is an uncommon type of simple venous malformation in the superficial soft tissue and different from the classical glomus tumor. Morphologically, one or more layers of glomus cells grow around the dilated venous malformation-like lumen, which can be combined with common venous malformations.
Male
;
Female
;
Humans
;
Child
;
Glomus Tumor/surgery*
;
Endothelial Cells/pathology*
;
Paraganglioma, Extra-Adrenal/pathology*
;
Immunohistochemistry
7.The application of the non-woven fabric and filter paper "sandwich" fixation method in preventing the separation of the mucosal layer and muscular layer in mouse colon histopathological sections.
L SHEN ; Y T LI ; M Y XU ; G Y LIU ; X W ZHANG ; Y CHENG ; G Q ZHU ; M ZHANG ; L WANG ; X F ZHANG ; L G ZUO ; Z J GENG ; J LI ; Y Y WANG ; X SONG
Chinese Journal of Pathology 2023;52(10):1040-1043
9.Application and evaluation of artificial intelligence TPS-assisted cytologic screening system in urine exfoliative cytology.
L ZHU ; M L JIN ; S R HE ; H M XU ; J W HUANG ; L F KONG ; D H LI ; J X HU ; X Y WANG ; Y W JIN ; H HE ; X Y WANG ; Y Y SONG ; X Q WANG ; Z M YANG ; A X HU
Chinese Journal of Pathology 2023;52(12):1223-1229
Objective: To explore the application of manual screening collaborated with the Artificial Intelligence TPS-Assisted Cytologic Screening System in urinary exfoliative cytology and its clinical values. Methods: A total of 3 033 urine exfoliated cytology samples were collected at the Henan People's Hospital, Capital Medical University, Beijing, China. Liquid-based thin-layer cytology was prepared. The slides were manually read under the microscope and digitally presented using a scanner. The intelligent identification and analysis were carried out using an artificial intelligence TPS assisted screening system. The Paris Report Classification System of Urinary Exfoliated Cytology 2022 was used as the evaluation standard. Atypical urothelial cells and even higher grade lesions were considered as positive when evaluating the recognition sensitivity, specificity, and diagnostic accuracy of artificial intelligence-assisted screening systems and human-machine collaborative cytologic screening methods in urine exfoliative cytology. Among the collected cases, there were also 1 100 pathological tissue controls. Results: The accuracy, sensitivity and specificity of the AI-assisted cytologic screening system were 77.18%, 90.79% and 69.49%; those of human-machine coordination method were 92.89%, 99.63% and 89.09%, respectively. Compared with the histopathological results, the accuracy, sensitivity and specificity of manual reading were 79.82%, 74.20% and 95.80%, respectively, while those of AI-assisted cytologic screening system were 93.45%, 93.73% and 92.66%, respectively. The accuracy, sensitivity and specificity of human-machine coordination method were 95.36%, 95.21% and 95.80%, respectively. Both cytological and histological controls showed that human-machine coordination review method had higher diagnostic accuracy and sensitivity, and lower false negative rates. Conclusions: The artificial intelligence TPS assisted cytologic screening system has achieved acceptable accuracy in urine exfoliation cytologic screening. The combination of manual screening and artificial intelligence TPS assisted screening system can effectively improve the sensitivity and accuracy of cytologic screening and reduce the risk of misdiagnosis.
Humans
;
Artificial Intelligence
;
Urothelium/pathology*
;
Cytodiagnosis
;
Epithelial Cells/pathology*
;
Sensitivity and Specificity
;
Urologic Neoplasms/urine*

Result Analysis
Print
Save
E-mail