1.Treatment of foot and ankle deformities combined with knee and lower limb deformities using QIN Sihe's surgical strategy.
Jiancheng ZANG ; Xuyue PAN ; Yidong CUI ; Li XIAO ; Fangyuan WEI ; Zhaojun CHEN ; Zhengyi WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(8):965-973
OBJECTIVE:
To summarize the clinical characteristics of foot and ankle deformities combined with knee and lower limb deformities and evaluate the advantages, clinical outcomes, and considerations of QIN Sihe's surgical strategy for treating such complex deformities.
METHODS:
Between January 2022 and December 2024, 32 patients with foot and ankle deformities combined with knee and lower limb deformities were enrolled. The cohort included 23 males and 9 females, aged 10-67 years (mean, 41.1 years). The main etiologies included post-polio sequelae (20 cases) and congenital limb deformities (3 cases). Deformities were categorized as follows: equinovarus foot (12 cases), equinus foot (2 cases), equinovalgus foot (3 cases), equinus foot with swan-neck deformity (2 cases), calcaneus foot (5 cases), foot valgus (2 cases), knee flexion deformity (14 cases), genu recurvatum (4 cases), genu varum (3 cases), genu valgum (3 cases), lower limb shortening (3 cases), and lower limb external rotation (6 cases). QIN Sihe's surgical strategies included osteotomies, tendon releases, and tendon transfers for deformity correction, followed by external fixation for residual deformity adjustment and stabilization. Outcomes were assessed using QIN Sihe's Postoperative Evaluation Criteria for Lower Limb (Foot and Ankle) Deformity Correction and Functional Reconstruction.
RESULTS:
All patients were followed up 8-32 months (mean, 16.5 months). Complications included pin tract infection (1 case, 1 site), ankle pain (2 cases), delayed healing at the proximal tibial osteotomy site (1 case), and anterior talar dislocation (1 case). At last follow-up, insufficient correction of foot deformity was observed in 1 case; both knee and lower limb deformities were corrected, with only mild recurrence of knee flexion deformity in 1 case. The foot/ankle and knee joint function improved. Based on QIN Sihe's Postoperative Evaluation Criteria for Lower Limb (Foot and Ankle) Deformity Correction and Functional Reconstruction, outcomes were rated as excellent in 30 cases and good in 2 cases, with an excellent-good rate of 100%.
CONCLUSION
Foot and ankle deformities combined with knee and lower limb deformities are complex, QIN Sihe's surgical strategy can achieve satisfactory clinical outcomes for simultaneous correction.
Humans
;
Male
;
Female
;
Adult
;
Middle Aged
;
Child
;
Adolescent
;
Aged
;
Treatment Outcome
;
Young Adult
;
Plastic Surgery Procedures/methods*
;
Lower Extremity Deformities, Congenital/surgery*
;
Osteotomy/methods*
;
Foot Deformities, Congenital/surgery*
;
Ankle Joint/surgery*
;
Knee Joint/surgery*
;
Foot Deformities/surgery*
2.Comparative study of NERC-300 high-frequency electric welding device in rat partial hepatectomy
Dongyue PAN ; Zhai CAI ; Shuai HAN ; Zhou LI ; Mengying SHEN ; Xuyue ZHOU ; Jiaying ZHOU ; Mifang LI
Chongqing Medicine 2018;47(5):601-603
Objective To contrastively study the effects of NERC-300 high frequency welding device and ultrasonic scalpel in rat partial hepatectomy.Methods Forty-eight rats were divided into the experimental group and control group(n=24).The experimental group applied NERC-300 high frequency welding instrument for conducting partial hepatectomy,while the control group used ultrasonic scalpel.The survival rate,operation time,bleeding volume,working temperature,extent of hepatic thermal damage and change of liver function on 1,3,7 d were compared between the two groups.Results The liver function recovery on 3 d in the experimental group was superior to the control group (P<0.05).The intra-operative working temperature in the experimental group was lower than that in the control group(P<0.05).The thermal damage range in the experimental group was lower than that in the control group(P<0.05).The survival rate,operation time,bleeding volume and liver function change on 1,7 d had no statistical differences between the two groups(P>0.05).Conclusion NERC-300 high frequency welding device is safe and effective for partial hepatectomy in rat.

Result Analysis
Print
Save
E-mail