1.Curative effect of distal tibiofibular screw fixation combined with ligament repair for the treatment of ankle fracture accompanied with distal tibiofibular syndesmosis injuries
Xuping LIN ; Qingjun LIU ; Zhenqi DING ; Bin LIN ; Weihuang LIN ; Weina XIE ; Chengquan TU
Chinese Journal of Trauma 2022;38(5):424-429
Objective:To investigate the clinical efficacy of distal tibiofibular screw fixation combined with ligament repair for the treatment of ankle fracture accompanied with distal tibiofibular syndesmosis injuries.Methods:A retrospective cohort analysis was made on clinical data of 72 patients with ankle fracture accompanied with distal tibiofibular syndesmosis injuries admitted to 909th Hospital of Joint Service Support Force of PLA from September 2017 to September 2020, including 38 males and 34 females, aged 19-65 years [(42.5±12.2)years]. The fracture was type B in 30 patients, type C 1 in 29 and type C2 in 13 according to Danis-Weber classification. A total of 36 patients were treated by distal tibiofibular screw fixation combined with ligament repair (fixation+repair group) and 24 patients by distal tibiofibular screw fixation (fixation group). Operation time, intraoperative blood loss and hospital stay were recorded. Visual analogue scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot score and ankle range of motion (ROM) were determined at 1, 3 months postoperatively and at the final follow-up. Complications were documented. Results:All patients were followed up for 12-22 months [(15.9±2.2)months]. There were no significant differences in operation time, intraoperative blood loss and hospital stay between the two groups (all P>0.05). VAS in fixation+repair group was (3.1±1.0)points and (2.1±0.6)points at 1, 3 months postoperatively, significantly lower than (3.9±0.8)points and (2.6±0.8)points in fixation group (all P<0.05), but the score showed no significant difference between the two groups at the final follow-up ( P>0.05). AOFAS score in fixation+repair group was (64.7±4.0)points, (73.2±3.4)points and (87.2±3.4)points at 1, 3 months postoperatively and at the final follow-up, significantly higher than (60.1±4.9)points, (70.2±1.9)points and (84.1±2.6)points in fixation group (all P<0.05). There was no significant difference in the ROM between the two groups at 1 month postoperatively ( P>0.05), but the ROM at 3 months postoperatively and at the final follow-up in fixation+repair group [(44.4±2.9)° and (52.3±2.5)°, respectively] was significantly higher than that in fixation group [(41.4±2.7)° and (50.1±2.7)°, respectively] (all P<0.05). There was 1 patient with internal fixation loosening in fixation+repair group, with the incidence of complications of 3% (1/36). While the incidence of complications was significantly lhigher in fixation group [17%(6/36)], including 2 patients with re-separation of distal tibiofibular syndesmosis, 2 with internal fixation loosening and 2 with internal fixation breakage ( P<0.05). Conclusion:Compared with distal tibiofibular screw fixation, distal tibiofibular screw fixation combined with ligament repair for the treatment of ankle fracture accompanied with distal tibiofibular syndesmosis injuries is effective to early relieve ankle pain, improve ankle function and ROM, and reduce occurrence of complications.
2.Analysis of the reasons of contrast agent venues intravasation during transvaginal four-dimensional hysterosalpingo-contrast sonography
Ying SANG ; Xingxing ZHOU ; Weiqun WANG ; Zixin MAI ; Keni DENG ; Xuping XIE
Chinese Journal of Ultrasonography 2020;29(8):706-710
Objective:To explore the influencing factors of uterine myometrial and parauterine venous plexus reflux during transvaginal four-dimensional contrast-enhanced hysterosalpingography, which will help reduce and avoid the occurrence of reflux and improve the accuracy of diagnosis.Methods:A total of 306 infertile patients who underwent transvaginal four-dimensional contrast-enhanced hysterosalpingograph from June 2016 to June 2017 in the Third Affiliated Hospital of Guangzhou Medical University were retrospectively enrolled. The ultrasonographic characteristics were reviewed and the correlations between reflux and endometrial thickness, days after menstruation, intrauterine operation history and patency of fallopian tube were analyzed.Results:The incidence of countercurrent during four-dimensional contrast-enhanced hysterosalpingography was 14.71%. The chi-square test showed that the endometrial thickness and the days after menstruation had statistically significant effects on the incidence of reflux ( P=0.031 and <0.001, respectively). There were no statistically significant effects of intrauterine operation history and patency of the fallopian tube on the incidence of reflux ( P=0.610, 0.137). Logistic regression analysis showed that the incidence of reflux was associated with endometrial thickness ( B=-1.171, P<0.001) and the days after menstruation ( B=0.439, P=0.015). Conclusions:Transvaginal ultrasound measurement of endometrial thickness before angiography and selection of appropriate examination time according to the menstrual cycle can effectively reduce the incidence of reflux, and adverse reactions, and improve the accuracy of four-dimensional contrast-enhanced hysterosalpingography.
3.Research on the Current Situation of Health Food Inspection Standard System
Jing ZHANG ; Yin XIE ; Liangfa WU ; Xuping LIU
China Pharmacist 2017;20(8):1450-1452
Standards provide technical basis for the development of health food, which are the technical cornerstone for health food to base on and the technical methods for the promotion of quality improvement of health food.Under the new situation of the Thirteenth Five-year period, a more systematic, safer and more effective inspection standard system for health food is urgently needed to establish, which can fully satisfy the growing needs of health food products and meet the requests of industry development at high level.Based on the current standards of health food, this paper stated the present development situation of inspection standard system of health food, and studied and summarized the main problems in the standard source, classification and existing standard system.On this basis, the author put forward some exploratory suggestions to improve the standard system of health food.
4.Correlation between the characteristics of vertebrobasilar artery on magnetic resonance angiography and isolated vertigo
Xuping GAO ; Gaosheng XIE ; Rong YAN
International Journal of Cerebrovascular Diseases 2016;24(12):1085-1090
Objective To investigate the correlation between the morphological characteristics of vertebrobasilar artery on magnetic resonance angiography (MRA) and isolated vertigo. Methods The patients with isolated vertigo were enrolled retrospectively as a case group. Other patients without vertigo were selected over the same period as a control group. The clinical data and MRA data were collected. Univariate analysis and multivariate logistic regression analysis were used to identify the independent risk factors for isolated vertigo. Results A total of 118 patients with isolated vertigo and 179 controls were enrolled. Univariate analysis showed that there were significant differences in left vertebral artery bending degree, basilar artery stenosis rate, previous stroke, dolichoec tatic basilar artery, and left and right vertebral artery hypoplasia between the two groups (all P < 0.05). Multivariate logistic regression analysis showed that previous vertigo (odds ratio [OR] 6.177, 95%confidence interval [CI] 1.945-19.620; P = 0.002), more serious left vertebral artery bending (OR 1.860, 95% CI 1.127-3.069; P =0.015), and left vertebral artery hypoplasia (OR 4.543,95% CI 1.761-11.721; P = 0.002) were the independent risk factors for isolated vertigo, and previous stroke ( OR 0.377, 95% CI 0.162-0.877; P = 0.024), basal artery hypoplasia ( OR 0.401, 95% CI 0.193-0.830; P = 0.014) were its protective factors. Conclusions Previous vertigo, more serious left vertebral artery bending, and left vertebral artery hypoplasia are the independent risk factors for isolated vertigo, and previous stroke and basal artery hypoplasia may be its protective factors.
5.Percutaneous vertebroplasty for treatment of metastatic tumor in axis
Gang SUN ; Peng JIN ; Yuhai YI ; Xunwei LIU ; Fandong LI ; Zhiyong XIE ; Xuping ZHANG ; Min LI
Chinese Journal of Radiology 2010;44(4):421-423
Objective To explore the safety and effectiveness of percutaneous vertebrophasty(PVP)in the treatment of the metastatic tumor involved axis.Methods Ten patients(8 male,2 female)with osteolytic metastases involved axis were treated with PVPs.The anterolateral approach with fluoroscopy guidance was selected in 9 cases,while the posterolateral approach with CT guidance was selected in 1 case.Results Successful unilateral-paracentesis for PVP were achieved in all patients without intervention related complications such as bleeding and symptomatic polymethylmethacrylate(PMMA)leakage.CT scan taken following PVP showed that over 70% of the osteolytic metastatic area was well filled with PMMA in all cases.Varying degrees of pain relief were observed(CR in 7 cases,PR in 3 cases)within 7 days.All patients could support their heads without brackets.During a 3 to 24 months follow up after the procedures,No aggravated pain was found in the group.Two patients died in 4 months,3 Patients died in 8 to 11 months 4 patients died in 13 to 15 months,and 1 patient still was alive after 24 months.Conclusion Anterolateral or posterolateral approach to Aixs in PVP is safe and effective in treating osteolytic metastatic tumors.
6.Imaging and pathologic study of intravertebral vacuum phenomenon in vertebral compression fracture
Gang SUN ; Peng JIN ; Min LI ; Xunwei LIU ; Fandong LI ; Zhiyong XIE ; Xuping ZHANG ; Changling LIN
Chinese Journal of Radiology 2010;44(2):165-168
Objective To investigate the features of intravertebral vacuum phenomenon (IVP)in vertebral compression fractures (VCFs). Methods Two hundred and nine patients with VCFs underwent percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP). The biopsies and the images of X-ray, CT, MRI of VCFs were obtained. The consistency between IVP and osteonecrosis on histology and the positive predictive value (PPV), negative predictive value (NPV), sensitivity, specificity and Youden index of IVP for diagnosing local osteonecrosis in VCFs were analyzed. Fisher exact probability test was used to analyze the coherence between IVP and osteonecrosis. Results Histological examination revealed 146(69.9%) osteoporoses, 10 (4.8%) osteonecroses with osteoporoses, 53 (25.4%) neoplasms. Prior to surgery,10 cases of IVP were found. Plain radiograph showed horizontally oriented lucent cleft in the vertebral body;CT further confirmed the location of gas;T_1-weighted MR image appeared hypointensity,while the signal intensity of T_2-weighted MR image differed, depending on the duration of recumbency. Nine of 10 patients with IVP showed osteonecrosis on histology, while 9 of 10 patients with osteonecrosis contained IVP. The association of osteonecrosis on histology and the IVP was statistically significant(P <0.01). The PPV, NPV, sensitivity, specificity, and Youden index for diagnosing local osteonecrosis was 90% (9/10), 99.5% (198/199), 90.0% (9/10), 99.5% (198/199), and 0.9, respectively. Conclusion The IVP is stongly suggestive of local osteonecrosis in vertebral compression fracture.
7.Kyphoplasty with single balloon inflation followed by cement filling for osteoporotic vertebral compression fractures
Gang SUN ; Peng JIN ; Xunwei LIU ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG ; Runsong HAO
Chinese Journal of Tissue Engineering Research 2008;12(6):1179-1183
BACKGROUND: In kyphoplasty procedure, two balloons are inserted into the vertebral body and inflated simultaneously for height symmetric restoration of the vertebral body. However, the expensive cost of balloon of kyphoplasty limits the extensive development of this procedure in developing countries. In this study, we try to inflate single balloon with bilateral transpedicular routes alternatively to achieve vertebral body height balanced restoration and reduce operation expenditure. But biocompatibility of bone cement and effect of kyphoplasty still need further observation.OBJECTIVE: To investigate the biocompatibility of bone cement and the clinical efficacy of bipedicular kyphoplasty for osteoporotic vertebral compression fractures by inserting single inflatable balloon into injured vertebral body and filling bone cement in the cavity caused by inflating balloon via bipedicular approach.DESIGN: Controlled observation.SETTING: Department of Medical Imaging, General Hospital of Jinan Military Area Command of Chinese PLA.PARTICIPANTS: Twenty-two patients (31 vertebral bodies) undergoing kyphoplasty with single balloon in Department of Medical Imaging, General Hospital of Ji'nan Military Area Command of Chinese PLA from May 2004 to May 2005 were selected, including 5 males and 17 females aged 68-85 years. Patients with painful compression fractures caused by osteoporosis were enrolled, and confirmed by CT and MRI with complete vertebral posterior wall but no spine deformity. The informed consent was obtained from all subjects, and the experiment and treatment were approved by Ethics Committee. METHODS: The especial instrument for kyphoplasty including puncturing device and balloon were provided by Shandong Guanlong Medical Utensils Co., Ltd. [LDAI (T) 2004 No. 2150017]; bone cement (Polymethymethacrylate) was made in China [MAIT 2005(T) No. 3650267]. Under X-ray fluoroscopy monitoring, single inflatable balloon was inserted into fractured vertebral body by puncturing needle and inflated via bipedicular approach to restore vertebral height. MAIN OUTCOME MEASURES: ①Bone cement biocompatibility during and after surgery; ②pain relief within 72 hours after surgery, restoration of vertebral height and correction of kyphotic deformity.RESULTS: ①Bone cement biocompatibility: Little cement leakage was observed at one intervertebral space of one patient by X-ray film, but no clinical symptoms, inflammatory reaction or rejection were found. ②Obvious pain relief was found in 22 cases with within 72 hours after kyphoplasty. ③The height loss of the anterior and middle vertebral body reduced from (14.70±4.21) mm and (10.62±4.11) mm preoperatively to (10.38±4.23) mm and (6.45±4.04) mm postoperatively after single balloon inflation and cement filling. Cobb angle was corrected averagely from (21.15±6.33)° preoperatively to (11.64±4.33)° postoperatively. CONCLUSION:Biocompatibility of bone cement is good, and no specific adverse effects are found in despite of cement leakage. Bipedicular kyphoplasty with single balloon for painful osteoporotic vertebral compression fractures effectively restores vertebral heights and relieves pain.
8.The preliminary study on a single balloon cross-medline expansion using unipedicular approach in kyphoplasty
Gang SUN ; Peng JIN ; Xunwei LIU ; Runsong HAO ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG
Chinese Journal of Radiology 2008;42(5):519-522
Objective To evaluate the clinical efficacy and safety of kyphoplasty with single balloon cross-midline expansion using unipedicular approach for osteoporotic vertebral body compressive fracture (OVCF).Methods Thirty six cases of painful OVCF were included in the study,with 61 vertebrae involved.Under X-ray fluoroscopy monitoring,kyphoplasty was performed using a unilateral,single,balloon via a unilateral transpedicular approach.A final balloon position was in the midline of the vertebral body with the balloon cross-midline expansions and bone cement filled. Clinical outcomes were determined by comparison of preoperative and postoperative VAS and ODI scores.Radiographic assessment included vertebral height restoration and correction of kyphosis.Follow-up was conducted for 6.0-12.0 months(mean 9.2 months).Results Thirty-six consecutive patients with 61 vertebrae were successfully operated with an operative time of(37.4±9.6)rain per vertebra.All patients had significant pain relief and functional recovery within 96 h after the procedure with no surgery-and device-related complications.VAS score improved from(7.3±1.0)preoperatively to(2.7±0.8)postoperatively(t=19.53,P<0.01).ODI score was decreased from(71.1±10.9)%preoperatively to(26.6±6.4)%postoperatively(t=18.54,P<0.01).The average anterior body height loss was(14.3±2.8)mm before procedure and(10.0±1.8)mm after procedure(t=14.68,P<0.01).The average middle body height loss was(10.2±2.7)mm before procedure and(5.9±1.8)mm after procedure(t=16.44,P<0.01).The Cobb's angle was corrected from 23.4°±5.0° to 16.2°±2.8°(t=15.60,P<0.01).Some leakages of cement around the anterior margin of vertebra and inter-vertebral space were found in 2 patients,but there were no clinical symptoms.X-ray examination indicated there were no cement leakages in other vertebra.The pain relief and functional recovery were substantial and maintained to the last follow up without any re-collapse or adjacent level fracture.Conclusions A single-balloon cross-midline expansion using unipedicular approach in kyphoplasty for OVCF is effective and safety,less operation time,less radiation exposure compared to the conventional kyphoplasty technique.
9.Analysis of the factors affecting the accuracy of detection for single base alterations by oligonucleotide microarray.
Sanzhen LIU ; Yao LI ; Xuping FU ; Minyan QIU ; Bin JIANG ; Hai WU ; Rongyu LI ; Yumin MAO ; Yi XIE
Experimental & Molecular Medicine 2005;37(2):71-77
The oligonucleotide microarray, a high-throughput polymorphism detection technology, holds great promise for the characterization of complex genetic variance. To achieve greater sensitivity and specificity for it to be an effective platform technology we present results and discuss some of the factors influencing signal intensities and single-mismatch discrimination in array-based mutation/SNP detection. Probes with a series of concentrations were spotted onto the slide in order to find the optimal concentration with the identifiable satisfying signals and the stable ratios between matched and mismatched probes. It was found that under our experimental conditions, when the initial probe concentration is higher than the maximum immobilization capability of the slide (7.5 micrometer), the hybridization signal will be saturated and the ratio between matched and mismatched probes will be more stable than at a lower probe concentration. Considering the cost of probes and the systematic stability, a constant spotting concentration of 10 micrometer was selected. The stability of different types of mismatched oligo-DNA duplexes on the glass surface was also confirmed. The results show that the order of stability of mismatched oligo-DNA duplexes on a glass surface is in general agreement with previous reports conducted using liquid and polyacrylamide gel pads. This suggests that the influence of the mismatched base pair on the stability of the duplex in a solid hybridization system is similar to that in the solution hybridization environment.
Nucleic Acid Heteroduplexes/chemistry
;
*Nucleic Acid Hybridization
;
*Oligonucleotide Array Sequence Analysis
;
Oligonucleotide Probes/chemistry
;
*Polymorphism, Single Nucleotide
;
Research Support, Non-U.S. Gov't
10.Percutaneous vertebroplasty using instruments and drugs made in China for vertebral metastases.
Gang SUN ; Yongjian CONG ; Zonggui XIE ; Peng JIN ; Fandong LI ; Yuhai YI ; Xuping ZHANG
Chinese Medical Journal 2003;116(8):1207-1212
OBJECTIVESTo evaluate the effect of percutaneous vertebroplasty on vertebral tumor metastasis using instruments and drugs made in China and to explore the technique of percutaneous vertebroplasty.
METHODSThirty-two patients with vertebral metastasis were treated with percutaneous vertebroplasty with instruments and drugs made in China. Anterolateral approach for cervical vertebrae and transpedicular approach for thoracic and lumbar vertebrae were used. The volume of disease focus and the amount of polymethy methacrylate (PMMA) injected were calculated with formula V = 4/3pi (D/2)(3) preoperatively. PMMA with contrast was mixed according to the ratio of powder/liquid/contrast of 3:2:1. The procedures were monitored under fluoroscopy. PMMA was injected in the polymerization time. CT scanning was performed before and after the operation.
RESULTSThe percentage of lesion PMMA fill was more than 50% as demonstrated by CT. Clinical data were obtained from the cases followed up for 7 - 12 months, and the rate of pain relief was 90.6% (29/32) at one week, 71.8% (23/32) at six months, and 58.6% (17/29) at 12 months after operation. There were no cases of PMMA leakage that affected clinical performance.
CONCLUSIONSPercutaneous vertebroplasty for vertebral tumor metastasis using instruments and drugs made in China was effective. It is important to prevent paravertebral leaks of PMMA and to ensure that PMMA is injected within the polymerization time.
Aged ; Aged, 80 and over ; China ; Female ; Humans ; Lumbar Vertebrae ; surgery ; Male ; Middle Aged ; Polymethyl Methacrylate ; administration & dosage ; Reconstructive Surgical Procedures ; instrumentation ; methods ; Spinal Neoplasms ; secondary ; surgery ; Spine ; surgery ; Thoracic Vertebrae ; surgery

Result Analysis
Print
Save
E-mail