1.Comparison of SEC-RI-MALLS and SEC-RID methods for determining molecular weight and molecular weight distribution of PLGA
WANG Baocheng ; ZHANG Xiaoyan ; ZHOU Xiaohua ; ZHAO Xun ; MA Congyu ; GAO Zhengsong ; SHI Haiwei ; YUAN Yaozuo ; HANG Taijun
Drug Standards of China 2025;26(1):110-116
Objective: To establish a method for determining the molecular weight and molecular weight distribution of Poly(Lactide-co-Glycolide Acid) (PLGA) using Size Exclusion Chromatography-Refractive Index-Multiangle Laser Light Scattering (SEC-RI-MALLS) and Size Exclusion Chromatography-Refractive Index (SEC-RID), and to compare the results obtained from these two methods.
Methods: For SEC-RI-MALLS, tetrahydrofuran was used as the mobile phase, Shodex GPC KF-803L was employed as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, and an injection volume of 100 μL. For SEC-RID, tetrahydrofuran was also used as the mobile phase, Agilent PLgel 5 μm MIXD-D was used as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, differential detector temperature at 35 ℃, and an injection volume of 20 μL. The molecular weight and molecular weight distribution were calculated using Agilent’s GPC software. The newly established methods were validated methodologically, and the molecular weight and molecular weight distribution of 13 batches of samples were determined.
Results: The precision, accuracy, stability, and repeatability tests for SEC-RI-MALLS showed RSD values of 1.35%, 1.58%, 1.53%, and 1.26%, respectively. The SEC-RID method exhibited good linearity (r=0.999 9), with RSD values for precision, accuracy, stability, and repeatability tests (n=6) of 2.05%, 1.62%, 1.30%, and 2.97%, respectively. The results obtained from SEC-RI-MALLS were lower than those from SEC-RID, and the molecular weight distribution coefficient was smaller, but the results from the paired T-test performed with the value measured by SEC-RID method and the value measured by SEC-RI-MALLS method multiplied a conversion coefficient of 1.5 showed no significant difference between the two methods.
Conclusion: Both methods are stable and reliable, and can be used for the determination of PLGA molecular weight and molecular weight distribution based on the specific situations.
2.Construction and application of the "Huaxi Hongyi" large medical model
Rui SHI ; Bing ZHENG ; Xun YAO ; Hao YANG ; Xuchen YANG ; Siyuan ZHANG ; Zhenwu WANG ; Dongfeng LIU ; Jing DONG ; Jiaxi XIE ; Hu MA ; Zhiyang HE ; Cheng JIANG ; Feng QIAO ; Fengming LUO ; Jin HUANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):587-593
Objective To construct large medical model named by "Huaxi HongYi"and explore its application effectiveness in assisting medical record generation. Methods By the way of a full-chain medical large model construction paradigm of "data annotation - model training - scenario incubation", through strategies such as multimodal data fusion, domain adaptation training, and localization of hardware adaptation, "Huaxi HongYi" with 72 billion parameters was constructed. Combined with technologies such as speech recognition, knowledge graphs, and reinforcement learning, an application system for assisting in the generation of medical records was developed. Results Taking the assisted generation of discharge records as an example, in the pilot department, after using the application system, the average completion times of writing a medical records shortened (21 min vs. 5 min) with efficiency increased by 3.2 time, the accuracy rate of the model output reached 92.4%. Conclusion It is feasible for medical institutions to build independently controllable medical large models and incubate various applications based on these models, providing a reference pathway for artificial intelligence development in similar institutions.
3.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
4.Expression of CD19/CD73 in Chronic Lymphocytic Leukemia and Its Correlation with Clinical Features.
Yan-Yu WANG ; Lan LIU ; Yu-Jie ZHAO ; Geng-Hui SHI ; Xun MIN
Journal of Experimental Hematology 2025;33(5):1274-1278
OBJECTIVE:
To investigate the expression of CD19/CD73 in chronic lymphocytic leukemia (CLL) and its correlation with clinical features.
METHODS:
The clinical data of 60 CLL patients and 40 healthy volunteers (control group) from January 2022 to November 2023 were retrospectively analyzed. The levels of CD19 and CD73 in peripheral blood of CLL patients were measured by flow cytometry. Kaplan-Meier method was used for survival analysis.
RESULTS:
The hemoglobin (Hb) and CD19/CD73 levels in CLL group were significantly lower than those in control group, while CD19, CD73 and β2-MG were significantly higher (all P <0.001). According to ROC curve analysis, the AUC value of CD19/CD73 for CLL diagnosis was 0.980 (95%CI : 0.949-1.000, P <0.05), the specificity was 92.50%, and the sensitivity was 98.30%. The CD19/CD73 level of CLL patients with splenomegaly was significantly lower than those without splenomegaly (P <0.01). There was no significant correlation between CD19/CD73 and Hb in CLL patients ( r =0.056, P >0.05). CD19/CD73 was positively correlated with β2-MG ( r =0.837, 95%CI : 0.740 2-0.899 6, P <0.01). According to the median value (12.84) of CD19/CD73, the patients were divided into high and low expression groups. Kaplan-Meier survival analysis showed that the overall survival rate and progression-free survival rate at 18th month in the low expression group were 87.08% and 93.25%, while those in the high expression group were 96.41% and 99.90%, respectively (both P <0.05).
CONCLUSION
The level of CD19/CD73 is low in CLL patients, which can be used as an auxiliary index for clinical diagnosis of CLL. CD19/CD73 is closely related to splenomegaly in CLL patients. Low expression of CD19/CD73 predicts poor prognosis.
Humans
;
Leukemia, Lymphocytic, Chronic, B-Cell/metabolism*
;
5'-Nucleotidase/metabolism*
;
Antigens, CD19/metabolism*
;
Retrospective Studies
;
Male
;
Female
;
Prognosis
;
Middle Aged
;
Aged
;
Adult
;
GPI-Linked Proteins
5.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
6.Development of A Portable Gas Chromatograph-Micro Photoionization Detector System and Its Application in Online Detection of Volatile Organic Compounds
Xun WEN ; Hao-Nan XU ; Li-Li SHI ; Xiang-Hong WANG ; Xiao-Bing PANG
Chinese Journal of Analytical Chemistry 2025;53(10):1615-1622
In recent years,micro photoionization detectors(μPID),with their rapid response speed and excellent sensitivity,have attracted widespread attention in both scientific research and industry.This study developed a portable gas chromatograph based on μPID technology(GC-μPID),and examined its key performance characteristics such as reproducibility,sensitivity,and online analytical capability.The results showed that the method's relative standard deviation(RSD)was controlled within 2.7%,demonstrating good reproducibility;for the standard curves of 27 kinds of volatile organic compounds(VOCs),the linearity was excellent(R2≥0.99),with detection limits of≤10 μg/m3 and benzene series compounds reaching detection limits as low as 0.5 μg/m3.In field applications at an industrial park,this method successfully identified and quantified 17 kinds of VOCs,accurately capturing their diurnal concentration variations.The results above validated that the method developed here had the capability of onsite real-time monitoring and provided an effective tool for in situ monitoring atmospheric pollutants.
7.Expression and clinical significance of serum tumor-associated antigens in patients with rheumatoid arthritis
Ying XIA ; Yu TANG ; Xinyi ZHA ; Yanru WANG ; Wei SHI ; Xun GONG ; Yingying QIU ; Xiaoming FEI
Journal of Clinical Medicine in Practice 2025;29(9):1-6
Objective To investigate the expression of serum tumor-associated antigens(TAAs)in patients with rheumatoid arthritis(RA)and analyze their clinical significance for RA.Methods A total of 214 RA patients were enrolled in the RA group,while 198 age-and gender-matched healthy individuals were included in the HC group.Rheumatoid factor(RF),anti-cyclic citrullinated peptide antibody(Anti-CCP),C-reactive protein(CRP),erythrocyte sedimentation rate(ESR),interleu-kin-6(IL-6),ferritin levels,as well as gender,age,disease duration,disease activity score(DAS28)and clinical manifestations were collected from the RA group.The expression of TAAs in RA patients and the clinical characteristics of TAA-positive patients were analyzed.Spearman correla-tion analysis was used to evaluate the relationships between TAAs and clinical indicators in RA pa-tients.Results The positive rate of carbohydrate antigen 125(CA125)in the RA group was 8.88%,which was significantly higher than 1.01% in the HC group(P<0.001).Serum CA125 and cytok-eratin fragment 19(CYFRA21-1)levels in the RA group were significantly higher than those in the HC group,whereas alpha-fetoprotein(AFP),carcinoembryonic antigen(CEA),carbohydrate anti-gen 199(CA199)and neuron-specific enolase(NSE)levels were significantly lower(P<0.001).TAA-positive patients had significantly older age and higher rates of pulmonary interstitial lesions compared to TAA-negative patients(P<0.05).Patients with DAS28 scores>5.1 had significantly higher CA125 levels than those with DAS28 scores ≤5.1(P<0.05).CA125 levelswere positively corre-lated with DAS28 scores,ESR,RF,and anti-CCP antibodies(r=0.142,0.140,0.268,0.183;P<0.05).Conclusion In RA patients,the positivity rate and levels of some serum TAAs are ele-vated,and TAA-positive patients tend to be older and have higher incidence of pulmonary interstitial lesions.CA125 levels are positively correlated with RA disease activity.
8.Application of seminal carnitine assay in male fertility assessment and therapeutic monitoring of asthenospermia
Jun KAI ; Laiqing ZHU ; Minhuan LI ; Guohai SUN ; Xue ZHOU ; Xun WANG ; Youfeng HAN ; Liang SHI
Chinese Journal of Clinical Laboratory Science 2024;42(2):107-110
Objective To compare seminal carnitine levels between normal males and asthenozoospermic patients,evaluate its correla-tion with progressive motility(PR)of sperm,and observe the effects of exogenous carnitine supplementation on asthenozoospermic pa-tients.Methods Semen samples were collected from 511 normal fertile males and asthenozoospermic patients.Seminal was measured using a fixed-time assay kit and the levels of carnitine were compared between the two groups.The consistency between seminal carni-tine and PR was assessed.Additionally,77 asthenozoospermic patients received L-carnitine(1 g/time,3 times/day,30 days/course).The levels of seminal carnitine and PR alteration pre-and post-treatment were monitored.Results The seminal L-carnitine level in the patients with asthenospermia([194.34±65.41]μmol/L)was significantly lower than that in normal fertile males([405.43±72.12]μmol/L)(P<0.01).When the seminal L-carnitine level ≥325 μmol/L was set as the threshold,the statistical results showed that Kappa value was 0.81,with a diagnostic coincidence rate of 93.74%.After one course of administration of L-carnitine,the concentra-tion of seminal L-carnitine([356.03±84.87]μmol/L)and PR([32.69±8.35]%)were significantly higher those that before treat-ment([183.61±79.54]μmol/L and[16.56±7.74]%,P<0.01).Conclusion The seminal carnitine assay kit could be used for ac-curate and high-throughput quantification of clinical samples,facilitating asthenozoospermia diagnosis and therapeutic efficacy evalua-tion.Exogenous carnitine supplementation may elevate seminal carnitine levels and sperm motility in asthenozoospermic patients and po-tentially improve their fertility.
9.Schisandrin A ameliorates DSS-induced acute ulcerative colitis in mice via regulating the FXR signaling pathway
Jia-rui JIANG ; Kua DONG ; Yu-chun JIN ; Xin-ru YANG ; Yi-xuan LUO ; Shu-yang XU ; Xun-jiang WANG ; Li-hua GU ; Yan-hong SHI ; Li YANG ; Zheng-tao WANG ; Xu WANG ; Li-li DING
Acta Pharmaceutica Sinica 2024;59(5):1261-1270
Inflammatory bowel disease (IBD) is characterized by chronic relapsing intestinal inflammation and encompasses ulcerative colitis (UC) and Crohn's disease (CD). IBD has emerged as a global healthcare problem. Clinically efficacious therapeutic agents are deficient. This study concentrates on models of ulcerative colitis with the objective of discovering novel therapeutic strategies. Previous investigations have established that schisandrin A demonstrates anti-inflammatory effects
10.Antimicrobial resistance of bacteria from blood specimens:surveillance re-port from Hunan Province Antimicrobial Resistance Surveillance System,2012-2021
Hong-Xia YUAN ; Jing JIANG ; Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Xing-Wang NING ; Jun LIU ; Guo-Min SHI ; Man-Juan TANG ; Jing-Min WU ; Huai-De YANG ; Ming ZHENG ; Jie-Ying ZHOU ; Nan REN ; An-Hua WU ; Xun HUANG
Chinese Journal of Infection Control 2024;23(8):921-931
Objective To understand the change in distribution and antimicrobial resistance of bacteria isolated from blood specimens of Hunan Province,and provide for the initial diagnosis and treatment of clinical bloodstream infection(BSI).Methods Data reported from member units of Hunan Province Antimicrobial Resistance Survei-llance System from 2012 to 2021 were collected.Bacterial antimicrobial resistance surveillance method was imple-mented according to the technical scheme of China Antimicrobial Resistance Surveillance System(CARSS).Bacteria from blood specimens and bacterial antimicrobial susceptibility testing results were analyzed by WHONET 5.6 soft-ware and SPSS 27.0 software.Results A total of 207 054 bacterial strains were isolated from blood specimens from member units in Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021,including 107 135(51.7%)Gram-positive bacteria and 99 919(48.3%)Gram-negative bacteria.There was no change in the top 6 pathogenic bacteria from 2012 to 2021,with Escherichia coli(n=51 537,24.9%)ranking first,followed by Staphylococcus epidermidis(n=29 115,14.1%),Staphylococcus aureus(n=17 402,8.4%),Klebsiella pneu-moniae(17 325,8.4%),Pseudomonas aeruginosa(n=4 010,1.9%)and Acinetobacter baumannii(n=3 598,1.7%).The detection rate of methicillin-resistant Staphylococcus aureus(MRSA)decreased from 30.3%in 2015 to 20.7%in 2021,while the detection rate of methicillin-resistant coagulase-negative Staphylococcus(MRCNS)showed an upward trend year by year(57.9%-66.8%).No Staphylococcus was found to be resistant to vancomy-cin,linezolid,and teicoplanin.Among Gram-negative bacteria,constituent ratios of Escherichia coli and Klebsiella pneumoniae were 43.9%-53.9%and 14.2%-19.5%,respectively,both showing an upward trend(both P<0.001).Constituent ratios of Pseudomonas aeruginosa and Acinetobacter baumannii were 3.6%-5.1%and 3.0%-4.5%,respectively,both showing a downward trend year by year(both P<0.001).From 2012 to 2021,resistance rates of Escherichia coli to imipenem and ertapenem were 1.0%-2.0%and 0.6%-1.1%,respectively;presenting a downward trend(P<0.001).The resistant rates of Klebsiella pneumoniae to meropenem and ertapenem were 7.4%-13.7%and 4.8%-6.4%,respectively,presenting a downward trend(both P<0.001).The resistance rates of Pseudomonas aeruginosa and Acinetobacter baumannii to carbapenem antibiotics were 7.1%-15.6%and 34.7%-45.7%,respectively.The trend of resistance to carbapenem antibiotics was relatively stable,but has de-creased compared with 2012-2016.The resistance rates of Escherichia coli to the third-generation cephalosporins from 2012 to 2021 were 41.0%-65.4%,showing a downward trend year by year.Conclusion The constituent ra-tio of Gram-negative bacillus from blood specimens in Hunan Province has been increasing year by year,while the detection rate of carbapenem-resistant Gram-negative bacillus remained relatively stable in the past 5 years,and the detection rate of coagulase-negative Staphylococcus has shown a downward trend.

Result Analysis
Print
Save
E-mail