1.Influence of plasma infusion during orthotopic liver transplantation on the incidence of postoperative acute kidney injury
Xun LIU ; Liang BI ; Ren LANG ; Anshi WU
Organ Transplantation 2026;17(2):235-242
Objective To investigate the influence of plasma infusion during orthotopic liver transplantation on the incidence of acute kidney injury (AKI) in recipients. Methods Cinical data of 473 liver transplant recipients who underwent orthotopic liver transplantation at Beijing Chaoyang Hospital Affiliated to Capital Medical University from January 2016 to December 2020 were retrospectively collected. The study included 354 recipients who received plasma infusion during the operation (plasma group) and 119 recipients who did not receive plasma infusion during the operation (control group). Preoperative conditions, donor conditions, intraoperative conditions, main outcome indicators and secondary outcome indicators of the two groups were analyzed and compared. Receiver operating characteristic curve was drawn to calculate the maximum cut-off value of intraoperative plasma infusion volume that affected the occurrence of AKI within 7 days after surgery. Logistic regression analysis was performed to analyze the correlation between intraoperative plasma infusion volume and the incidence of AKI within 7 days after surgery. Results Before propensity score matching, the incidence of AKI within 7 days after surgery and the incidence of grade Ⅲ AKI in the plasma group were higher than those in the control group (both P<0.05). After propensity score matching, 62 recipients were included in each group. There was no statistically significant difference in the incidence of AKI within 7 days after surgery between the plasma group and the control group, but the incidence of grade Ⅲ AKI within 7 days after surgery in the plasma group was higher than that in the control group (P=0.041). Logistic regression analysis showed that intraoperative plasma infusion volume >900 mL was a potential risk factor for AKI within 7 days after surgery (odds ratio=1.936, 95% confidence interval 1.193-3.142, P=0.007). There were no statistically significant differences in the incidence of 365-day postoperative fatality, reperfusion syndrome, and postoperative 30-day complications between the two groups before and after propensity score matching. In addition, the postoperative albumin, fibrinogen levels, and international normalized ratio in the plasma group were better than those in the control group before and after matching (all P<0.05). Conclusions Large amount of intraoperative plasma infusion is associated with an increased risk of grade Ⅲ AKI after orthotopic liver transplantation. Intraoperative plasma infusion volume >900 mL may increase the risk of AKI within 7 days after surgery.
2.Protective effect of Shenfu injection against neonatal hypoxic-ischemic brain injury by inhibiting the ferroptosis
Xiaotong Zhang ; Meng Zhang ; Gang Li ; Yang Hu ; Yajing Xun ; Hui Ding ; Donglin Shen ; Ming Wu
Acta Universitatis Medicinalis Anhui 2025;60(1):31-40
Objective :
To observe the brain tissue injury during hypoxia-ischemia, as well as the pathological changes and the expression of ferroptosis-related factors after the use of Shenfu injection(SFI), and to explore the protective effect of SFI on hypoxic-ischemic brain injury(HIBD) by inhibiting ferroptosis.
Methods :
An animal model of HIBD in SD rats was constructed and intervened with SFI. Pathologic changes in brain tissue were observed by HE staining methods. Nissen staining was used to observe neuron survival. Glutathione Peroxidase 4(GPX4) and Divalent Metal Transporter 1(DMT1) expression were detected in brain tissue by Western blot, immunohistochemistry and immunofluorescence. Reduced Glutathione(GSH), Lactate Dehydrogenase(LDH), Malondialdehyde(MDA), Superoxide Dismutase(SOD) and tissue iron content were determined with the kits. BV-2 microglial cell line(BV2) cells were culturedin vitroand divided into control group(Ctrl group), oxygen-glucose deprivation group(OGD group), iron ferroptosis-inducing group(Erastin group), iron ferroptosis-inhibiting group(Fer-1 group), Shenfu injection group(SFI group), and Erastin+Shenfu injection group(Erastin+SFI group). 2′,7′-Dichlorodihydrofluorescein diacetate(DCFH-DA) reactive oxygen species(ROS) fluorescent probe was used to detect the ROS release level; Immunofluorescence was used to observe intracellular GPX4, DMT1 expression.
Results :
Compared with the Sham group, rats in the HIBD group showed significant neuronal cell damage in brain tissue, decreased GPX4 expression(P<0.01), increased DMT1 expression(P<0.01), decreased GSH and SOD levels(P<0.01), and increased LDH, MDA and tissue iron levels(P<0.05,P<0.05,P<0.01). In contrast, after the intervention of SFI, GPX4 expression was elevated(P<0.01), DMT1 expression decreased(P<0.01), GSH and SOD levels were elevated(P<0.01), and LDH, MDA, and tissue iron levels decreased(P<0.05,P<0.05,P<0.01). The cells experiments showed that compared with the Ctrl group, the OGD group had a significantly higher ROS content and a decrease in the expression of GPX4 fluorescence intensity, and an increase in the fluorescence intensity of DMT1(P<0.01), compared with the OGD group, the ROS content was reduced in the SFI group, while the expression of GPX4 was elevated and the expression of DMT1 was reduced(P<0.01).
Conclusion
Hippocampal and cortical regions are severely damaged after HIBD in neonatal rats, and their brain tissues show decreased expression of GPX4 and increased expression of DMT1. The above suggests that ferroptosis is involved in HIBD brain injury in neonatal rats. In contrast, Shenfu injection has a protective effect on HIBD experimental animal model and BV2 cell injury model by reducing iron aggregation and ROS production.
3.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
4.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
5.Anti-CD24 antibody-nitric oxide donor conjugates bearing a self-bioorthogonal cleavable linker.
Jianbing WU ; Tianyue CHENG ; Jiajun XIE ; Ziyu QIAN ; Linhua HUANG ; Xun YUAN ; Libang ZHANG ; Shan YANG ; Yihua ZHANG ; Tonglin XU ; Juan ZHANG ; Zhangjian HUANG
Acta Pharmaceutica Sinica B 2025;15(10):5366-5386
Triple-negative breast cancer (TNBC) is a highly aggressive malignancy predominantly managed via chemotherapy. Our clinical sample analysis revealed a significant correlation between elevated CD24 expression in TNBC tumor cells and patient survival rates. We developed a novel antibody-drug conjugate (ADC), named HN03, consisting of an antibody with engineered cysteines for site-specific conjugation with a low toxic nitric oxide (NO) precursor as its payload through a novel Pt(IV)-mediated bioorthogonal self-cleavable linker. HN03 specifically targets tumor cells expressing high levels of CD24, concurrently generating cisplatin and releasing NO upon activation. HN03 also exhibited potent in vitro and in vivo antitumor activity. It significantly reduced tumor growth at various doses, prevented tumor metastasis, with markedly lower toxicity than traditional chemotherapy agents. We found that a key mechanism of its action involved inducing apoptosis and endoplasmic reticulum stress, substantially decreasing the number of M2-type macrophages. Overall, HN03 stands out as a promising therapeutic option for TNBC, offering a targeted treatment with reduced side effects and the potential for improved outcomes. Furthermore, using Pt(IV) in the linker and an NO precursor as the payload enhances the versatility of the Antibody-NO donor Conjugate (ANC), offering new avenues for the design of the next generation of ADCs.
6.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
7.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
8.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
9.Effect of performance of pneumatic logistics transmission system on quality of laboratory medicine
Hailong WANG ; Jing WU ; Xiaoya ZHENG ; Yaping WANG ; Lili CHEN ; Zhenbao SONG ; Xun CHEN
International Journal of Laboratory Medicine 2025;46(12):1498-1502
Objective To evaluate the effect of pneumatic logistics transport system(PTS)on the trans-portation efficiency of the transferred samples and the accuracy of the results.Methods The transportation speed,temperature and humidity change of PTS were analyzed by temperature and humidity transmitter.Anti-coagulant samples containing disodium ethylenediaminetetraacetate(EDTA-K2),sodium citrate,lithium hepa-rin and samples containing inert separation gel coagulant were selected.and used respectively for complete blood cell analysis,prothrombin time(PT),activated partial prothrombin time(APTT),troponin T(TnT)and other myocardial markers,as well as the detection of items such as glucose(Glu)and lactate dehydrogen-ase(LDH).According to the transfer mode,they were divided into the manual transfer group and the PTS transfer group,and according to the number of PTS transfers,they were divided into the one-time transfer group,the three-time transfer group and before transfer(control).The differences among each group were statistically analyzed,and 1/3 allowable total error(1/3TEa)was adopted as the criterion for determining the clinical application value.Results There was no statistically significant difference in the changes of tempera-ture and humidity during the transportation process of PTS compared with manual transportation(P>0.05),but it was significantly faster than manual transportation in terms of transportation time(P<0.05).Com-pared with before transfer,the differences between the PT,APTT,Glu and LDH items in the one-time trans-fer group and the three-time transfer group were statistically significant(P<0.01),and their deviations were all much greater than 1/3TEa.However,in the plasma samples,compared with before transport,there were statistically significant differences in Glu and LDH between the one-time transfer group and the three-time transfer group(P<0.05),but the deviations were all less than 1/3TEa.For the items of TnT,red blood cell count and hematocrit,compared with before transfer,there were statistically significant differences between some groups of the one-time transfer group and the three-time transfer group(P<0.05),but the deviations were all less than 1/3TEa.Conclusion PTS can significantly improve the transportation efficiency of sam-ples,but it significantly affects the detection of Glu and LDH in plasma samples,which can be improved by u-sing serum sample transportation instead.In addition,PTS also affects the detection of PT and APTT,and it is not recommended to use PTS to transport coagulation specimen.
10.Occipital lobe epilepsy
Journal of Apoplexy and Nervous Diseases 2025;42(8):675-680
Occipital lobe epilepsy (OLE) accounts for 5%-10% of all focal epilepsy cases. Ictal clinical symptoms mainly include visual and ocular movements, with common and specific elementary visual hallucinations. Electroencephalography has certain limitations, and a well-localized unifocal rhythmic ictal discharge during seizure is infrequent on ictal EEG. Detailed preoperative evaluation, especially the evaluation of symptoms and intracranial EEG monitoring, can help to obtain good outcomes after surgical treatment.


Result Analysis
Print
Save
E-mail