1.Clinical effect of non-diffractive extended depth of focus IOL in patients with high myopia complicated with cataract
Yanhong JIA ; Xuemei LIANG ; Litao TAN ; Fang FU ; Yuanran PANG ; Kangming ZHU ; Li LI
International Eye Science 2026;26(4):700-705
AIM: To evaluate the postoperative clinical efficacy of non-diffractive extended depth of focus intraocular lens(EDOF IOL)in patients with highly myopic cataract(HMC).METHODS:A retrospective analysis was conducted on the clinical data of patients diagnosed with HMC at the hospital from January 2022 to December 2024. Patients were divided into an observation group [undergoing femtosecond laser-assisted cataract surgery(FLACS)combined with non-diffractive EDOF IOL implantation] and a control group(undergoing FLACS combined with aspheric monofocal IOL implantation)according to the type of implanted IOL. Postoperative visual acuity(LogMAR), visual quality, and patient satisfaction were compared between the two groups.RESULTS: A total of 33 patients(47 eyes)were finally included in this study, including 10 patients(17 eyes)in the observation group and 23 patients(30 eyes)in the control group. The observation group had a median age of 59.0(52.8, 63.8)y, with 8 males(13 eyes)and 2 females(4 eyes). The control group had a median age of 56.0(53.5, 60.0)y, with 13 males(17 eyes)and 10 females(13 eyes). At 3 mo postoperatively, the best-corrected distance visual acuity(BCDVA)was 0.10(0.08, 0.12)in the observation group and 0.20(0.10, 0.40)in the control group(P=0.586). However, the best-corrected intermediate visual acuity(BCIVA)[0.10(0.10, 0.10)vs 0.50(0.40, 0.90), P=0.032] and best-corrected near visual acuity(BCNVA)[0.20(0.18, 0.20)vs 0.60(0.45, 1.45), P=0.044] in the observation group were significantly better than those in the control group. The defocus curve showed that the uncorrected visual acuity(UCVA)in the observation group was relatively stable within the range of -2.00 to +1.00 D, which was superior to that in the control group. Postoperative questionnaires showed that the spectacle independence rate(76%)and overall satisfaction(88%)in the observation group were significantly higher than those in the control group(10% and 60%, respectively).CONCLUSION: Non-diffractive EDOF IOL significantly improves intermediate and near visual acuity, reduces spectacle dependence, and maintains distance visual acuity by extending the depth of focus, providing better postoperative visual quality and life satisfaction for HMC patients.
2.Distribution of traditional Chinese medicine syndromes in intrahepatic cholestasis of pregnancy and its association with perinatal outcomes
Jin CHEN ; Dan YANG ; Qianrong LI ; Yan SANG ; Zhi YU ; Jiao XU ; Xuemei WANG ; Heying HUANG ; Xue TANG ; Lin ZHUANG ; Xiaoyin WANG
Journal of Clinical Hepatology 2025;41(11):2343-2350
ObjectiveTo investigate the distribution of traditional Chinese medicine (TCM) syndromes in intrahepatic cholestasis of pregnancy (ICP) and its association with perinatal outcomes, and to provide a basis for precise treatment based on TCM syndrome differentiation. MethodsA cross-sectional study was conducted among 275 patients with ICP who were admitted to The Affiliated Hospital of Chengdu University of Traditional Chinese Medicine from April 2023 to April 2025. A hierarchical cluster analysis was used to summarize TCM syndromes. The Kruskal-Wallis H test was used for comparison of non-normally distributed continuous data between groups, and the chi-square test was used for comparison of categorical data between groups. A multivariate Logistic regression analysis was used to identify the clinical features significantly associated with TCM syndrome. ResultsThe cluster analysis identified three core TCM syndromes among the 275 patients with ICP, i.e., liver-gallbladder damp-heat syndrome (45.8%), syndrome of blood deficiency generating wind (30.9%), and liver depression and spleen deficiency syndrome (23.3%). There was a significant difference in the distribution of TCM syndromes between different groups stratified by maternal age at delivery, parity, history of ICP recurrence, gestational weeks at disease onset, total bile acid (TBA), alanine aminotransferase (ALT), and comorbidity with gestational diabetes mellitus (GDM) (all P<0.05). The multivariate Logistic regression analysis showed that<34 gestational weeks at disease onset was significantly associated with all three syndromes (damp-heat: odds ratio [OR]=3.769, P<0.001; blood deficiency: OR=4.031, P<0.001; liver stagnation: OR=3.552, P<0.001). Liver-gallbladder damp-heat syndrome was associated with maternal age ≥35 years at disease onset (OR=2.048, P=0.014), parity ≥2 times (OR=1.921, P=0.034), history of ICP recurrence (OR=2.404, P=0.030), ALT ≥200 U/L (OR=2.051, P=0.018), comorbidity with GDM (OR=1.944, P=0.029), and TBA ≥40 μmol/L (OR=2.542, P=0.024). The syndrome of blood deficiency generating wind syndrome was associated with maternal age ≥35 years (OR=2.939, P=0.003), parity ≥2 time (OR=3.222, P=0.003), history of ICP recurrence (OR=3.809, P=0.010), ALT ≥200 U/L (OR=2.889, P=0.006), comorbidity with GDM (OR=3.711, P=0.001), and comorbidity with hypertensive disorders of pregnancy (OR=4.472, P=0.011). Liver depression and spleen deficiency syndrome was associated with TBA ≥40 μmol/L (OR=2.995, P=0.044). The analysis of perinatal outcomes showed that there were significant differences in mode of delivery, gestational weeks at the time of delivery, postpartum blood loss, and neonatal birth weight between the three groups with different TCM syndromes (all P<0.05). ConclusionLiver-gallbladder damp-heat syndrome, syndrome of blood deficiency generating wind, and liver depression and spleen deficiency syndrome are the main TCM syndrome types in ICP, and the distribution of TCM syndromes is closely associated with clinical factors and perinatal outcomes, which provides a basis for precise TCM syndrome differentiation and individualized treatment.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Application of Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation sputum expulsion in the treatment of severe pneumonia in children
Wenyuan ZHUANG ; Hongjuan WU ; Xuemei WU
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2023;30(6):676-680
Objective To analyze the application value of Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation sputum expulsion in children with severe pneumonia,and provide theoretical reference for the formulation of treatment plans for severe pneumonia.Methods From April 2022 to April 2023,120 children with severe pneumonia were selected from the Children's Respiratory Department of the Second Affiliated Hospital of Wenzhou Medical University.According to different treatment plans,the children were divided into traditional airway clearance group,Acapella positive expiratory pressure therapy group,high-frequency chest wall oscillation treatment group,and Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation treatment group,with 30 cases in each group.The duration of pneumonia symptom remission and hospitalization,as well as the difference of pulmonary function index and inflammatory factors before and after treatment were compared.Results Compared with traditional airway clearance group,Acapella positive expiratory pressure therapy group,high-frequency chest wall oscillation treatment group,the disappearance time of pulmonary rales,the recovery time of body temperature,the time of cough relief and the length of stay of children in the Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation treatment group were significantly shortened[the disappearance time of pulmonary rales(days):4.85±0.78 vs.8.47±2.36,5.22±2.12,5.38±1.56,the recovery time of body temperature(days):3.51±1.04 vs.7.84±2.34,4.45±1.92,4.76±1.59,the time of cough relief(days):7.45±2.15 vs.13.59±4.08,8.88±3.35,8.72±2.59,the length of stay(days):3.78±0.63 vs.8.29±2.07,5.02±1.44,4.96±1.25,all P<0.05].The disappearance time of pulmonary rales,the recovery time of body temperature,the time of cough relief,and the length of stay in Acapella positive expiratory pressure therapy group and high-frequency chest wall oscillation treatment group were shorter than those in traditional airway clearance group(all P<0.05).Forced expiratory volume in one second(FEV1),forced vital capacity(FVC)and FEV1/FVC after treatment were significantly higher than before treatment,and the inflammatory factors tumor necrosis fact-α(TNF-α),hypersensitive C-reactive protein(hs-CRP)and white blood cell count(WBC)were significantly lower than before treatment.After treatment,FEV1,FCV and FEV1/FVC in the Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation treatment group were significantly higher than those in the traditional airway clearance group,Acapella positive expiratory pressure therapy group and high-frequency chest wall oscillation treatment group[FEV1(L):3.65±1.33 vs.2.28±0.45,2.94±0.63,2.99±0.72,FVC(L):4.56±1.84 vs.2.94±0.83,3.46±1.28,3.65±1.34,FEV1/FVC:(72.36±8.84)% vs.(59.84±4.05)%,(62.35±5.22)%,(64.59±5.58)%,all P<0.05].The pulmonary function indexes of children in Acapella positive expiratory pressure therapy group and high-frequency chest wall oscillation treatment group were higher than those in traditional airway clearance group(all P<0.05).After treatment,the levels of serum inflammatory factors in the Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation treatment group were significantly lower than those in the traditional airway clearance group,Acapella positive expiratory pressure therapy group,high-frequency chest wall oscillation treatment group[TNF-α(ng/L):14.62±4.55 vs.29.44±6.13,18.09±5.33,17.52±4.42,hs-CRP(mg/L):21.41±3.65 vs.48.67±8.39,40.24±6.42,37.24±5.12,WBC(×109/L):13.42±3.67 vs.19.29±6.45,15.43±5.34,14.22±4.14,all P<0.05],the serum inflammatory factor indexes of Acapella positive expiratory pressure therapy group,high-frequency chest wall oscillation treatment group were lower than those of traditional airway clearance group(all P<0.05).Conclusion Acapella positive expiratory pressure therapy combined with high-frequency chest wall oscillation sputum expulsion is effective in the treatment of severe pneumonia in children,which can shorten the time of sputum improvement and hospital stay,reduce the level of inflammatory factors,improve the pulmonary function of the children,and promote the rehabilitation process of the children.
8.Risk factors and prognostic value of heart-type fatty acid binding protein in patients with heart failure
Yuyi CHEN ; Pengchao TIAN ; Changhong ZOU ; Jiayu FENG ; Yan HUANG ; Qiong ZHOU ; Mei ZHAI ; Xiaofeng ZHUANG ; Yihang WU ; Boping HUANG ; Jingyuan GUAN ; Jing WANG ; Xinqing LI ; Xuemei ZHAO ; Tianyu XU ; Yuhui ZHANG ; Jian ZHANG
Chinese Journal of Laboratory Medicine 2022;45(9):968-976
Objective:To investigate the prognostic value and related factors of heart-type fatty acid binding protein (H-FABP) in patients with heart failure.Methods:A total of 877 consecutive patients who were admitted to heart failure care unit of Fuwai hospital and diagnosed as heart failure from July 2015 to July 2017 were enrolled in this study. Baseline serum H-FABP concentration was measured by fluorescence lateral flow immunoassay. According to serum H-FABP levels, patients were divided into three groups: low H-FABP group (H-FABP≤4.04 ng/ml, n=292), middle H-FABP group (H-FABP 4.04-7.02 ng/ml, n=292) and high H-FABP group (H-FABP≥7.02 ng/ml, n=293). The general clinical characteristics were collected and compared among the three groups. According to whether heart failure was caused by coronary artery disease or not, patients with heart failure were divided into ischemic heart failure and non-ischemic heart failure. Multivariate linear regression analysis was performed to explore the independent risk factors of H-FABP. The primary endpoint events were the composite of all-cause death or heart transplantation. Multivariate Cox regression analyses, receiver operating characteristic (ROC) curves, risk prediction tests with multivariate Cox regression model and Kaplan-Meier analyses were conducted to investigate the relationship between H-FABP and the prognosis of heart failure. Results:Multivariate linear regression analysis showed that age, coronary artery disease, alanine aminotransferase, uric acid and N-terminal pro-B type natriuretic peptide (NT-proBNP) were positively associated with H-FABP (β=0.012, 0.238, 0.001, 0.345 and 0.063 respectively,all P<0.05), while female, hemoglobin, albumin, sodium, and estimated glomerular filtration rate (eGFR) were negatively associated with H-FABP (β=-0.184, -0.006, -0.016, -0.034 and -0.006 respectively, all P<0.05). One hundred and nineteen patients (13.6%) lost to follow-up, and 246 patients (32.5%) suffered from all-cause death or heart transplantation during the median follow-up duration of 931 (412-1 185) days. Multivariate Cox regression analysis showed that baseline H-FABP (log 2H-FABP) level was the independent predictor of all-cause death or heart transplantation in patients with heart failure ( HR=1.39, P<0.001). ROC curves showed that baseline H-FABP was a predictor of all-cause death or heart transplantation in patients with heart failure within 3 months, 1 year and 2 years (areas under the curves were 0.69, 0.69 and 0.71 respectively), and the best cut-off values were 5.85 ng/ml, 6.54 ng/ml and 6.54 ng/ml respectively. Risk prediction test with multivariate Cox regression model showed that baseline H-FABP could provide additional prognostic value in predicting all-cause death or heart transplantation for patients with heart failure on top of basic model and baseline NT-proBNP ( P<0.001). Taking 6.54 ng/ml and trisected levels of H-FABP as cut-off values respectively, Kaplan-Meier analyses showed that the survival rates were significantly different among the two or three groups ( P<0.001). Subgroup analyses showed that baseline H-FABP (log 2H-FABP) level was an independent predictor of all-cause death or heart transplantation in patients with ischemic heart failure ( HR=1.74, P<0.001), as well as in patients with non-ischemic heart failure ( HR=1.28, P=0.027). Conclusions:Age, sex, coronary artery disease, hemoglobin, albumin, alanine aminotransferase, sodium, eGFR, uric acid and NT-proBNP are associated with H-FABP level. Baseline H-FABP level is an independent predictor of all-cause death or heart transplantation in patients with heart failure. On top of basic model and baseline NT-proBNP, baseline H-FABP could provide additional prognostic value in predicting adverse events for patients with heart failure.
9.Severe lower gastrointestinal hemorrhage caused by overdose of aspirin without a doctor′s advice
Jieting ZHANG ; Hai YANG ; Xuemei ZHUANG ; Di YU
Adverse Drug Reactions Journal 2020;22(11):638-639
A 67-year-old female patient took aspirin enteric-coated tablets 100 mg thrice daily orally in order to prevent arteriosclerotic cardiovascular disease without doctor′s advice. After 42 days of medication, the patient developed hematochezia, which was progressively aggravated and finally led to severe hemorrhagic anemia (red blood cell count 1.55×10 12/L, hemoglobin 47 g/L) and decreased blood pressure (58/33 mmHg). On the 4th day of bleeding, exploratory laparotomy was performed and colonic hemorrhage was diagnosed. Ligation of the mesenteric artery was performed and the patient′s bleeding stopped. The patient took aspirin by herself at a daily dose exceeding the recommended dose without assessment of benefits and bleeding risks by professional physicians and developed severe lower gastrointestinal hemorrhage, which led to hospitalization and surgical treatment. It was a grade H medication error.
10.Severe lower gastrointestinal hemorrhage caused by overdose of aspirin without a doctor′s advice
Jieting ZHANG ; Hai YANG ; Xuemei ZHUANG ; Di YU
Adverse Drug Reactions Journal 2020;22(11):638-639
A 67-year-old female patient took aspirin enteric-coated tablets 100 mg thrice daily orally in order to prevent arteriosclerotic cardiovascular disease without doctor′s advice. After 42 days of medication, the patient developed hematochezia, which was progressively aggravated and finally led to severe hemorrhagic anemia (red blood cell count 1.55×10 12/L, hemoglobin 47 g/L) and decreased blood pressure (58/33 mmHg). On the 4th day of bleeding, exploratory laparotomy was performed and colonic hemorrhage was diagnosed. Ligation of the mesenteric artery was performed and the patient′s bleeding stopped. The patient took aspirin by herself at a daily dose exceeding the recommended dose without assessment of benefits and bleeding risks by professional physicians and developed severe lower gastrointestinal hemorrhage, which led to hospitalization and surgical treatment. It was a grade H medication error.

Result Analysis
Print
Save
E-mail