1.Assessment and management of HIV-reactive blood donors based on routine blood screening data
Xuelian DENG ; Xiaohan GUO ; Yingying WANG ; Xiaochun LIU ; Xiaohua LIANG
Chinese Journal of Blood Transfusion 2026;39(4):430-436
Objective: To establish evidence-based, safe and efficient management of HIV-reactive blood donors by investigating safe and feasible assessment strategies for HIV-reactive blood donors based on routine blood screening data. Methods: The data of blood screening, supplementary testing, follow-up and CDC confirmation for HIV-reactive blood donors in our center from 2014 to 2024 were analyzed systematically to confirm HIV infection and identify infection status. Results: There were 1 235 samples (0.13%, 1 235/928 000) reactive in HIV blood screening over the 11-year period. A-mong them, 199 donors (16.11%) in asymptomatic HIV infection (HIV Ag/Ab++&HIV RNA+), 2(0.16%) as acute early HIV infection (HIV Ag/Ab+-&HIV RNA+) and 7(0.57%) as window-period infection (HIV RNA positive only) were confirmed. Donors with the result of HIV Ag/Ab+-&HIV RNA-(single-positive) were all excluded for HIV infection, while 1 in 6 HIV Ag/Ab++&HIV RNA-donors (double-positive) was confirmed to have HIV infection. When HIV Ag/Ab reagents were used continuously before and after the follow-up, it's observed in one reagent that the proportion of negative results in subsequent follow-up in single-positive donors who had negative results in the first sampling was significantly higher than the proportion of negative results in subsequent follow-up in those initially single-positive (P<0.05). But no significant difference was observed in another reagent (P>0.05). When reagents were changed in follow-up, the rate of singlepositive donors with negative results in the first sampling reached 96.7%, which was significantly higher than the negative rate of those without reagent changing in follow-up (P<0.05). Conclusion: Based on the serological and nucleic acid testing results of HIV blood screening, the confirmation of HIV infection and identification of infection status can be achieved accurately and efficiently. All HIV Ag/Ab+-&HIV RNA-donors were confirmed as false positive, and should be maintained their eligibilities for blood donation, but recommended to pass the retest before next donation. Using a different reagent for retesting helps improve the eligible rate. HIV Ag/Ab++&HIV RNA-donors should be deferred permanently due to the risk of true positivity.
2.The management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection
Xuelian DENG ; Liang ZANG ; Xiaofang GONG ; Lei ZHOU ; Xiaochun LIU ; Lin WANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):444-451
Objective: To explore the management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection. Methods: Multiple HCV antibody assays, repeating HCV RNA testing, follow-up of blood donors and retesting of archive samples were performed to confirm HCV infection, identify infection status, and exclude false positives in blood donors reactive to HCV in blood screening. Results: From 2011 to 2024, the unqualified rate of HCV detection in blood screening was 2.45‰(2 751/1 122 026). Among these, anti-HCV+-&NAT-accounted for 1.85‰, followed by anti-HCV++ at 0.60‰. The proportion of anti-HCV+-&NAT-and HCV RNA yields was extremely low (0.007‰). The positive rate of anti-HCV+-&NAT-samples tested by electrochemiluminescence method (ELCIA) was approximately 7.5%, differing among reagents (P<0.05). The follow-up of anti-HCV+-&NAT-donors showed that 96.2% (202/210) were false positives, but 51.4% of donors remained anti-HCV+-&NAT-during follow-up. Among them, 8 donors (3.8%) could not be ruled out from HCV infection due to positive retesting by ELCIA. Of the anti-HCV+-&NAT-donors who were reactive at the first follow-up, 86.8% remained anti-HCV+-&NAT-at the second follow-up. The sampling confirmation data showed that all of 260 anti-HCV++ donors were confirmed as anti-HCV positive, and the proportion of false positives or missed detections by NAT was very low. Two occult HBV infections (OBIs) and one HBsAg carrier were identified among the 3 anti-HCV +-&NAT+ donors, and no HCV infection was confirmed in 5 anti-HCV--&HCV RNA + donors. Conclusion: The prevalence of HCV among blood donors in Dalian was about 0.06%, with extremely low proportion of window-period infection and slightly higher proportion of resolved infections than that of current infections. The majority of anti-HCV+-&NAT-were false positive. Blood donors confirmed as false positive should be qualified in blood screening 3 months later before next donation. In order to reduce the false positive results, it was advisable to avoid the same type of supplementary reagents as the initial reagents when performing confirmation.
3.Confirmatory analysis of HBsAg reactive samples from voluntary blood donors
Qiaolin ZHANG ; Fang WANG ; Dong LIU ; Fengjiao HAN ; Liu LI ; Xiaochuan ZHENG ; Xuelian DENG ; Dongyan YANG
Chinese Journal of Blood Transfusion 2026;39(4):452-457
Objective: To systematically analyze the confirmatory positivity of different combinations of HBsAg screening results in blood testing, providing data to support the optimization of blood donor eligibility management. Methods: A retrospective analysis was conducted on blood screening data from 174 266 voluntary blood donor samples at the Chongqing Blood Center between October 2021 and September 2022. Samples with inconsistent results between the two HBsAg enzymelinked immunosorbent assays (ELISA) and individual donor nucleic acid testing (NAT) were confirmed using an electrochemiluminescence immunoassay (ECLIA) and a neutralization test. The detection efficacy of four different HBsAg ELISA reagents was compared using the HBsAg-confirmed positive samples. Results: A total of 767(0.44%) HBV-reactive (HB-sAg and/or HBV DNA reactive) samples were detected. Among them, 344 samples with discordant serological and NAT results were collected, of which 64(18.6%) were confirmed positive by neutralization test. Additionally, 5 samples that were neutralization-negative but double-reactive for HBsAg and HBV DNA were confirmed as positive according to FDA guidance, resulting in a total of 69(20.1%) confirmed HBsAg-positive samples. There were significant differences in the neutralization test confirmation rates among different screening result categories (P<0.05): The group with dual HBsAg reagent reactivity (double reactive) & NAT-negative had the highest confirmation rate (96.9%, 31/32); the group reactive to only reagent 2 (single reactive) had a rate of 25.7% (29/113); while the confirmation rates for samples reactive to only reagent 1 and samples with isolated HBV DNA positivity were extremely low [0(0/34) and 2.4%(4/165), respectively]. The four commercial reagents showed significant differences in their ability to detect confirmed positive samples that were initially single reactive (P<0.05). Conclusion: Given the performance variations among HBsAg screening reagents, thorough performance verification is essential before implementation. When NAT is negative, dual HBsAg reactivity in screening can serve as a basis for confirming infection and directly deferring blood donors. However, confirming infection in donors with single HBsAg reactivity is more challenging, necessitating supplementary tests to rule out infection risk.
4.Evaluation of repeated testing with blood screening platform in confirmation of NAT non-discriminatory reactive samples
Mengfan LI ; Xuelian DENG ; Liang ZANG ; Lei ZHOU ; Xiaochun LIU ; Xiaohua LIANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):458-464
Objective: To evaluate repeated testing on blood screening platforms in confirmation of non-discriminatory reactive (NDR) samples in nucleic acid testing (NAT). Methods: A total of 102 HBsAg-negative/NAT NDR samples were collected from voluntary blood donors at Dalian Blood Center between January 2021 and December 2023. Repeated testing was performed using two NAT platforms (Cobas s201 and Panther). For the first round of repeated testing, all samples were tested 12 times on each system; for the second round, the samples which were non-reactive or only reactive once in the first round were tested an additional 8 times. Anti-HBc and anti-HBs was detected using electrochemiluminescence assay (ECA). Meanwhile, blood donors were followed up. Results: The proportion of anti-HBc+ in 102 NDR samples was 88.2%. Forty-one samples (40.2%, 41/102) and 7 samples were confirmed HBV DNA+ in first-round and second-round repeated testing, respectively. The cumulative confirmation rate of HBV DNA+ was 47.1% (48/102) after repeated testing. Extra five blood donors detected HBV DNA+ in follow-up were identified as anti-HBc+ occult hepatitis B virus infection (OBI), while no window period infection was observed. Ultimately, there were 53 HBV infected donors confirmed, 46 HBV infection-unconfirmed, and 3 HBV uninfected. No significant difference was observed between the confirmation rate of the first-round testing and the cumulative confirmation rate after the second-round testing (P>0.05). The proportion of anti-HBc+ donors was quite high in both HBV infection-confirmed (98.1%) and unconfirmed group (82.6%), and donors with seronegative and anti-HBs-only occupied a high proportion in the latter (P<0.05). Conclusion: Numerous repeated testing of NDR samples using NAT platforms cannot achieve complete confirmation of HBV infection. Supplementary anti-HBc testing can minimize potential OBI risk among NDR donors, and is low-cost and efficient.
5.Development and Validation of a High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Detecting Adrenocortical Hormones and Establishment of Age-Stratified Reference Intervals in Reproductive-Aged Women from Guangxi, China
Yixuan LIU ; Tingwei JIN ; Yushuang WEI ; Xuelian QIN ; Siyu DENG ; Jie ZHENG ; Boteng YAN ; Yuanyuan NONG ; Yu YE ; Shengzhu HUANG ; Yu LONG ; Jianmin LI ; Ganqin WANG ; Pei HUANG ; Jinghang JIANG ; Fan WU ; Zengnan MO ; Yonghua JIANG
Annals of Laboratory Medicine 2026;46(2):146-154
Background:
Adrenocortical hormones, particularly 11-oxygenated androgens, are pivotal in female reproductive health and fertility. Standardized detection kits and population-specific reference intervals are lacking in China, hindering related clinical applications.
Methods:
A HPLC-tandem mass spectrometry (HPLC-MS/MS) pipeline was developed, rigorously validated, and applied to simultaneously quantify corticosterone, cortisone, cortisol, 18-OH cortisol, androstenedione (A4), 11β-hydroxyandrostenedione (11-OH A4), dehydroepiandrosterone, and dehydroepiandrosterone sulfate in serum samples from 455 reproductive-aged women (18–45 yrs) in Guangxi, China. Age-dependent concentration trends were analyzed, and reference intervals stratified by age (2.5th to 97.5th percentiles) were established. Correlations with body-composition metrics, ethnicity, and the menstrual cycle were investigated.
Results:
The HPLC-MS/MS method demonstrated high precision (intra- and inter-assay CVs < 15%), accuracy, and sensitivity. All eight hormones exhibited significant age-related declines (P < 0.001 for seven hormones; P = 0.001 for 11-OH A4). Notably, 11-OH A4 levels were significantly lower in the 35–45-yr (3.05 nmol/L) and 25–34-yr (3.09 nmol/L) age groups than in the 18–24-yr (3.57 nmol/L) age group, whereas no significant difference was observed between the 35–45-yr and 25–34-yr age groups. Weak negative correlations were observed between the body mass index and corticosterone and cortisone levels, whereas ethnicity and the menstrual cycle showed no significant associations with hormone levels.
Conclusions
We developed an HPLC-MS/MS-based method for simultaneously quantifying eight adrenocortical hormones, including 11-OH A4, and defined age-specific reference intervals for reproductive-aged Chinese women. These findings advance the clinical utility of adrenocortical hormones in diagnosing and managing reproductive disorders.
6.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
7.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
8.Research on hepatitis E virus antigen screening among voluntary blood donors
Li ZHANG ; Xuelian DENG ; Lei ZHOU ; Dan LIU ; Liang ZANG
Chinese Journal of Blood Transfusion 2025;38(8):1083-1088
Objective: To investigate prevalence of hepatitis E virus (HEV) infection among voluntary blood donors in Dalian and provide evidence for enhancing blood screening strategies. Methods: A total of 3 277 blood donor samples collected between December 2023 and February 2024 at Dalian Blood Center underwent routine blood screening (ALT, HBsAg, anti-HCV, HIV Ag/Ab, anti-TP, and HBV/HCV/HIV NAT). Subsequently, HEV antigen (Ag) was detected using chemiluminescence immunoassay (CLIA). HEV-Ag reactive samples were further tested for HEV RNA, IgM and IgG antibodies. Blood donors with repeated reactive HEV Ag results were followed up to clarify the status of infection. Results: Among the 3 277 blood donor samples, 6 (0.18%) were repeatedly reactive for HEV Ag. However, supplemental testing for HEV RNA, anti-HEV IgM, and anti-HEV IgG on these samples yielded non-reactive results. One of these six blood donors was successfully followed up. On day 218 after the initial detection of HEV Ag reactivity, HEV Ag, HEV RNA, HEV IgM and IgG antibody were found to be non-reactive. Conclusion: The reaction rate for HEV antigen screening among voluntary blood donors in Dalian is low. CLIA method for detecting HEV antigen is easy to operate and cost-effective, but demonstrates some false reactivity. Improving the specificity of the assay and combining it with nucleic acid testing (NAT) would be valuable for implementing a selective HEV screening strategy for blood donors.
9.Clinical characteristics and risk factors in patients with upper urinary tract stones complicated with non-alcoholic fatty liver disease
Enxu XIE ; Xuelian GU ; Xiaohan CHU ; Shengwei ZHANG ; Xinze XIA ; Xiaofu WANG ; Changwei LIU ; Changbao XU
Journal of Modern Urology 2025;30(7):571-575
Objective To explore the clinical characteristics and risk factors of upper urinary tract stones complicated with non-alcoholic fatty liver disease(NAFLD),so as to provide reference for the prevention of this disease.Methods The clinical data of 158 NAFLD patients undergoing surgical treatment in our hospital during Jan.2022 and Jul.2023 were retrospectively analyzed.According to whether the patients were complicated with NAFLD,they were divided into the NAFLD group(n=56)and non-NAFLD group(n=102).The general data,laboratory indexes and 24-h urinary metabolic indexes were compared between the two groups,and the risk factors were analyzed with univariate and multivariate logistic regression analyses.Results Compared with the non NAFLD group,the NAFLD group had higher BMI[(28.17±4.17)vs.(24.11±3.72),P<0.001],blood uric acid[(354.13±111.01)μmol/L vs.(294.41±93.72)μmol/L,P<0.001],and 24-h urinary oxalate level[(37.74±15.00)mmol vs.(27.73±15.27)mmol,P<0.001].Multivariate logistic analysis showed that BMI(OR=1.311,P<0.001),24-h urinary oxalate(OR=1.046,P=0.004),and 24-h urinary magnesium(OR=0.599,P=0.002)were the independent factors for NAFLD with upper urinary tract stones.Conclusion NAFLD complicated with upper urinary tract stones is significantly associated with high BMI,high 24-h urinary oxalate,and low 24-h urinary magnesium.
10.Palpitations, Shortness of Breath, Weakness in Limbs, Edema, and Dyspnea: A Rare Inflammatory Myopathy with Positive Aniti-mitochondrial Antibodies and Cardiac Involvement
Chunsu LIANG ; Xuchang ZHANG ; Ning ZHANG ; Lin KANG ; Xiaohong LIU ; Jiaqi YU ; Yingxian LIU ; Lin QIAO ; Yanli YANG ; Xiaoyi ZHAO ; Ruijie ZHAO ; Na NIU ; Xuelian YAN
Medical Journal of Peking Union Medical College Hospital 2025;16(1):248-255
This article presents a case study of a patient who visited the Geriatric Department of Peking Union Medical College Hospital due to "palpitations, shortness of breath for more than 2 years, limb weakness for 6 months, edema, and nocturnal dyspnea for 2 months". The patient exhibited decreased muscle strength in the limbs and involvement of swallowing and respiratory muscles, alongside complications of heart failure and various arrhythmias which were predominantly atrial. Laboratory tests revealed the presence of multiple autoantibodies and notably anti-mitochondrial antibodies. Following a comprehensive multidisciplinary evaluation, the patient was diagnosed with anti-mitochondrial antibody-associated inflammatory myopathy. Treatment involved a combination of glucocorticoids and immunosuppressants, along with resistance exercises for muscle strength and rehabilitation training for lung function, resulting in significant improvement of clinical symptoms. The case underscores the importance of collaborative multidisciplinary approaches in diagnosing and treating rare diseases in elderly patients, where careful consideration of clinical manifestations and subtle abnormal clinical data can lead to effective interventions.

Result Analysis
Print
Save
E-mail