1.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
2.Exploration of stratified treatment plans for neonatal congenital chylothorax
Lei LIU ; Yajuan WANG ; Xuefang YANG ; Yijun DING
Chinese Journal of Perinatal Medicine 2025;28(3):241-246
Objective:To explore the stratified treatment plan process for neonatal congenital chylothorax by summarizing its clinical treatment characteristics.Methods:A retrospective analysis was conducted on the clinical data of 36 neonates with congenital chylothorax treated at the Department of Neonatology of Beijing Children's Hospital, Capital Medical University, from January 1, 2010, to December 31, 2021. Based on different treatment methods and initial drainage volumes, the cases were divided into the conservative treatment group [initial drainage volume<20 ml/(kg·d), n=20], octreotide group [initial drainage volume ≥20-<30 ml/(kg·d), n=4], erythromycin group [initial drainage volume ≥30-<50 ml/(kg·d), n=6], and octreotide plus erythromycin group [initial drainage volume≥50 ml/(kg·d), n=6]. The clinical characteristics and treatment effects of the children in different treatment groups, as well as the choice of further treatment plans, were summarized to determine the timing of different treatment methods. A more standardized stratified treatment plan was formulated by combining the literature. Results:Among the 36 cases of congenital chylothorax, 18 cases (50.0%) were diagnosed in utero, with no intrauterine intervention. In the conservative treatment group, 20 cases were treated with respiratory support, thoracic drainage, and nutritional therapy. Except for one case who was discharged after abandoning treatment, the remaining 19 cases were cured. In the octreotide group, four children received continuous intravenous infusion of octreotide at doses ranging from 1 to 10 μg/(kg·h), with three cases improving and one case being cured. No adverse effects such as hypoglycemia, thyroid dysfunction, or neonatal necrotizing enterocolitis occurred. In the group of six children who received intrapleural erythromycin injections, the dosage of erythromycin was 25-30 mg/kg, and the median thoracic drainage volume was reduced to approximately 50% of the pre-treatment volume after 3-5 injections, with four cases improving and two cases being cured. In the group of six children who received octreotide combined with erythromycin, treatment involved the intravenous infusion of octreotide along with intrapleural erythromycin injections. Four cases showed improvement, and two cases were cured. Based on previous treatments and a comprehensive review of the literature, a stratified treatment flowchart with invasiveness ranging from low to high was finally formed. Conclusions:For congenital chylothorax, a stratified treatment approach is recommended based on initial drainage volume and the response to treatment. This approach ranges from conservative treatment to pharmacological treatment (intravenous infusion of octreotide). For children with poor outcomes, surgical treatment (intrapleural erythromycin injection or other surgical interventions) can be added.
3.Optimization of Discrete Element Simulation Parameter Calibration Method for Traditional Chinese Medicine Extract Powder Under Low Shear Conditions
Xuefang TANG ; Huanzheng LI ; Zichen LIANG ; Yifei LIU ; Ying LIU ; Fangfang XU ; Bing XU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):211-218
ObjectiveTo improve the accuracy of discrete element method in simulating the processing of traditional Chinese medicine(TCM) powder system under low shear conditions. MethodsIn this study, extract powders of Tongsaimai tablets and Qige granules were used as the research objects, the angle of repose(AOR) and effective angle of internal friction of the two materials were determined by AOR test method and shear cell test method. Based on the Hertz-Mindlin with JKR V2 contact model and particle scaling theory, taking the particle-particle restitution coefficient(A), particle-particle static friction coefficient(B), particle-particle rolling friction coefficient(C), particle-steel restitution coefficient(D), particle-steel static friction coefficient(E), particle-steel rolling friction coefficient(F) and Johnson-Kendall-Roberts(JKR) surface energy(G) as test factors, the simulated contact parameters of Tongsaimai tablets extract powder were first calibrated with a single reference value using AOR as the reference value, and then the simulated contact parameters of Tongsaimai tablets extract powder as well as Qige granules extract powder were co-calibrated with AOR and effective angle of internal friction as the joint reference value, respectively. Then, Plackett-Burman design was used to screen the critical contact parameters that have a significant effect on the simulated reference value, and the steepest ascent design was used to determine the optimal range of the critical contact parameters, finally, the regression model between the critical contact parameters and the simulated reference values was established through the design of the response surface test, and the critical contact parameters were calibrated based on the regression model and the desirability function approach. ResultsThe optimal combination of discrete elemental contact parameters A-G for Tongsaimai tablets extract powder under a single reference value was 0.100, 0.718, 0.616, 0.100, 0.400, 0.250 and 0.075 J·m-2, which was validated to have relative errors of 0.10% and -8.64% for the simulated AOR and the simulated effective angle of internal friction, respectively. And the optimal combination of discrete elemental contact parameters A-G for Tongsaimai tablets extract powder at the joint reference values was 0.100, 0.682, 0.598, 0.100, 0.521, 0.294 and 0.075 J·m-2, which was verified to have relative errors of 0.10% and -0.18% for the simulated AOR and the simulated effective angle of internal friction, respectively. The optimal combination of discrete elemental contact parameters A-G for Qige granules extract powder at the joint reference values was 0.150, 0.370, 0.330, 0.150, 0.500, 0.500 and 0.100 J·m-2, which was verified to have relative errors of 2.70% and -1.30% for the simulated AOR and the simulated effective angle of internal friction, respectively. Compared with the single reference value method, the joint calibration method not only increased the number of the critical contact parameters for characterizing particle-device interactions, but also was more accurate and reliable. ConclusionCompared with the results of single reference value calibration, the results obtained by the method of joint calibration of discrete element simulation contact parameters with AOR and effective angle of internal friction as the reference values are more accurate, which can provide more accurate and reliable simulation physical property data for the simulation experiments of TCM extract powder under low shear process conditions.
4.Comparison of magnetic resonance images of the temporomandibular joint using different coils
Xiaojie ZHANG ; Tingting WU ; Ye ZHANG ; Ruiqiang GUO ; Zhi YIN ; Yue ZHAO ; Jian WANG ; Tingjun LI ; Hongmei LIU ; Xicheng GUO ; Xinhua ZHANG ; Wei HOU ; Tingting LIU ; Xuefang MA ; Xinhua LIU
Chinese Journal of Stomatology 2025;60(7):713-722
Objective:To explore and compare the clinical application value of 8-channel head phased-array coil, an 8-channel temporomandibular joint (TMJ)-specific surface coil, and a single-channel surface coil in TMJ MRI examinations.Methods:A total of 600 temporomandibular disorders (TMD) patients (1 200 joints) who underwent TMJ MRI examination in the First People′s Hospital of Jinzhong from June 2020 to January 2025 were retrospectively screened. Based on inclusion/exclusion criteria, 120 TMD patients (240 joints) with closed-mouth oblique sagittal proton density weighted imaging (OSag PDWI), coronal T2 fat-suppression weighted imaging (OCor fs T2WI) and open-mouth oblique sagittal proton density weighted imaging (OSag PDWI) were included. Patients were divided into groups A, B, and C, with 40 cases in each group. Group A (31female, 9male, median age 24 years old), underwent 8-channel head phased-array coil imaging. Group B (29 female, 11male, median age 23.5 years old) underwent TMJ imaging with an 8-channel surface coil. Group C (29 female, 11male, median age 22.5 years old) underwent single-channel surface coil imaging. There were no significant differences in age, gender, type or disease types among groups ( P>0.05). Six healthy volunteers without TMD (4 female, 2 male, range 19 to 45 years old) underwent imaging with all three coils as self-control. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality were compared for five regions of interest (ROI) in both patients and volunteers. Results:Under the same sequence and the same parameters, SNR and CNR in group B were higher than those in group A, and SNR and CNR in group C were also higher than those in group A, the differences were statistically significant ( P<0.05). However, there were significant differences in SNR and CNR between group B and group C in the closed and open positions of ROI1, the open positions of ROI3 and the open positions of ROI5 ( P<0.05), and there were no significant differences in other positions ( P>0.05). Group B had the best image quality, followed by group C and group A had the worst image quality. There were significant differences in the visualization of OSag PDWI in the closed mouth position, OCor T2WI in the coronal position, and OSag PDWI in the open mouth position, such as condyle, anterior attachment, joint disc, double lamina area, joint cavity and lateral pterygoid muscle ( P<0.05). There were significant differences between group B and group C in showing the joint cavity in the closed mouth position and showing the structure of the bilaminar area in the open mouth position ( P<0.05). There was no significant difference in other regions of interest ( P>0.05). The subjective scores of condyle, anterior attachment, articular disc, bilaminar area, articular cavity, lateral pterygos muscle and other structures were medium to high in group A, high in group B, and high or high in group C by two radiologists independently. In the five rois, the 8-channel TMJ surface coil showed more details, especially in the articular disc, condyle and lateral pterygoid muscle regions, and had more advantages in both volunteers and patients. Conclusions:The 8-channel TMJ-specific surface coil provides significantly clearer visualization of critical anatomical details within the ROIs, demonstrating the highest clinical application value and is recommended as the preferred choice.
5.Performance of Computer-Aided Detection Software in Tuberculosis Case Finding in Township Health Centers in China
Xuefang CAO ; Boxuan FENG ; Bin ZHANG ; Dakuan WANG ; Jiang DU ; Yijun HE ; Tonglei GUO ; Shouguo PAN ; Zisen LIU ; Jiaoxia YAN ; Qi JIN ; Lei GAO ; Henan XIN
Chronic Diseases and Translational Medicine 2025;11(2):140-147
Background::Computer-aided detection (CAD) software has been introduced to automatically interpret digital chest X-rays. This study aimed to evaluate the performance of CAD software (JF CXR-1 v3.0, which was developed by a domestic Hi-tech enterprise) in tuberculosis (TB) case finding in China.Methods::In 2019, we conducted an internal evaluation of the performance of JF CXR-1 v3.0 by reading standard images annotated by a panel of experts. In 2020, using the reading results of chest X-rays by a panel of experts as the reference standard, we conducted an on-site prospective study to evaluate the performance of JF CXR-1 v3.0 and local radiologists in TB case finding in 13 township health centers in Zhongmu County, Henan Province.Results::Internal assessment results based on 277 standard images showed that JF CXR-1 v3.0 had a sensitivity of 85.94% (95% confidence interval [CI]: 77.42%, 94.45%) and a specificity of 74.65% (95% CI: 68.81%, 80.49%) to distinguish active TB from other imaging conditions. In the on-site evaluation phase, images from 3705 outpatients who underwent chest X-ray detection were read by JF CXR-1 v3.0 and local radiologists in parallel. The imaging diagnosis of local radiologists for active TB had a sensitivity of 32.89% (95% CI: 22.33%, 43.46%) and a specificity of 99.28% (95% CI: 99.01%, 99.56%), while JF CXR-1 v3.0 showed a significantly higher sensitivity of 92.11% (95% CI: 86.04%, 98.17%) ( p < 0.05) and maintained high specificity at 94.54% (95% CI: 93.81%, 95.28%). Conclusions::CAD software could play a positive role in improving the TB case finding capability of township health centers.
6.Performance of Computer-Aided Detection Software in Tuberculosis Case Finding in Township Health Centers in China
Xuefang CAO ; Boxuan FENG ; Bin ZHANG ; Dakuan WANG ; Jiang DU ; Yijun HE ; Tonglei GUO ; Shouguo PAN ; Zisen LIU ; Jiaoxia YAN ; Qi JIN ; Lei GAO ; Henan XIN
Chronic Diseases and Translational Medicine 2025;11(2):140-147
Background::Computer-aided detection (CAD) software has been introduced to automatically interpret digital chest X-rays. This study aimed to evaluate the performance of CAD software (JF CXR-1 v3.0, which was developed by a domestic Hi-tech enterprise) in tuberculosis (TB) case finding in China.Methods::In 2019, we conducted an internal evaluation of the performance of JF CXR-1 v3.0 by reading standard images annotated by a panel of experts. In 2020, using the reading results of chest X-rays by a panel of experts as the reference standard, we conducted an on-site prospective study to evaluate the performance of JF CXR-1 v3.0 and local radiologists in TB case finding in 13 township health centers in Zhongmu County, Henan Province.Results::Internal assessment results based on 277 standard images showed that JF CXR-1 v3.0 had a sensitivity of 85.94% (95% confidence interval [CI]: 77.42%, 94.45%) and a specificity of 74.65% (95% CI: 68.81%, 80.49%) to distinguish active TB from other imaging conditions. In the on-site evaluation phase, images from 3705 outpatients who underwent chest X-ray detection were read by JF CXR-1 v3.0 and local radiologists in parallel. The imaging diagnosis of local radiologists for active TB had a sensitivity of 32.89% (95% CI: 22.33%, 43.46%) and a specificity of 99.28% (95% CI: 99.01%, 99.56%), while JF CXR-1 v3.0 showed a significantly higher sensitivity of 92.11% (95% CI: 86.04%, 98.17%) ( p < 0.05) and maintained high specificity at 94.54% (95% CI: 93.81%, 95.28%). Conclusions::CAD software could play a positive role in improving the TB case finding capability of township health centers.
7.Comparison of magnetic resonance images of the temporomandibular joint using different coils
Xiaojie ZHANG ; Tingting WU ; Ye ZHANG ; Ruiqiang GUO ; Zhi YIN ; Yue ZHAO ; Jian WANG ; Tingjun LI ; Hongmei LIU ; Xicheng GUO ; Xinhua ZHANG ; Wei HOU ; Tingting LIU ; Xuefang MA ; Xinhua LIU
Chinese Journal of Stomatology 2025;60(7):713-722
Objective:To explore and compare the clinical application value of 8-channel head phased-array coil, an 8-channel temporomandibular joint (TMJ)-specific surface coil, and a single-channel surface coil in TMJ MRI examinations.Methods:A total of 600 temporomandibular disorders (TMD) patients (1 200 joints) who underwent TMJ MRI examination in the First People′s Hospital of Jinzhong from June 2020 to January 2025 were retrospectively screened. Based on inclusion/exclusion criteria, 120 TMD patients (240 joints) with closed-mouth oblique sagittal proton density weighted imaging (OSag PDWI), coronal T2 fat-suppression weighted imaging (OCor fs T2WI) and open-mouth oblique sagittal proton density weighted imaging (OSag PDWI) were included. Patients were divided into groups A, B, and C, with 40 cases in each group. Group A (31female, 9male, median age 24 years old), underwent 8-channel head phased-array coil imaging. Group B (29 female, 11male, median age 23.5 years old) underwent TMJ imaging with an 8-channel surface coil. Group C (29 female, 11male, median age 22.5 years old) underwent single-channel surface coil imaging. There were no significant differences in age, gender, type or disease types among groups ( P>0.05). Six healthy volunteers without TMD (4 female, 2 male, range 19 to 45 years old) underwent imaging with all three coils as self-control. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality were compared for five regions of interest (ROI) in both patients and volunteers. Results:Under the same sequence and the same parameters, SNR and CNR in group B were higher than those in group A, and SNR and CNR in group C were also higher than those in group A, the differences were statistically significant ( P<0.05). However, there were significant differences in SNR and CNR between group B and group C in the closed and open positions of ROI1, the open positions of ROI3 and the open positions of ROI5 ( P<0.05), and there were no significant differences in other positions ( P>0.05). Group B had the best image quality, followed by group C and group A had the worst image quality. There were significant differences in the visualization of OSag PDWI in the closed mouth position, OCor T2WI in the coronal position, and OSag PDWI in the open mouth position, such as condyle, anterior attachment, joint disc, double lamina area, joint cavity and lateral pterygoid muscle ( P<0.05). There were significant differences between group B and group C in showing the joint cavity in the closed mouth position and showing the structure of the bilaminar area in the open mouth position ( P<0.05). There was no significant difference in other regions of interest ( P>0.05). The subjective scores of condyle, anterior attachment, articular disc, bilaminar area, articular cavity, lateral pterygos muscle and other structures were medium to high in group A, high in group B, and high or high in group C by two radiologists independently. In the five rois, the 8-channel TMJ surface coil showed more details, especially in the articular disc, condyle and lateral pterygoid muscle regions, and had more advantages in both volunteers and patients. Conclusions:The 8-channel TMJ-specific surface coil provides significantly clearer visualization of critical anatomical details within the ROIs, demonstrating the highest clinical application value and is recommended as the preferred choice.
8.Distribution and drug resistance of pathogens isolated from renal transplantation patients with postoperative nosocomial infections
Zhina YANG ; Zhuo WANG ; Yingnan CHEN ; Chang LIU ; Xuefang BEN ; Minmin PENG
Chinese Journal of Nosocomiology 2025;35(12):1814-1817
OBJECTIVE To analyze the distribution and drug resistance of pathogenic bacteria in hospital-associat-ed infections for patients after renal transplantation,and to provide a reference for the rational selection of antibac-terial drugs for anti-infective treatment in such patients.METHODS Clinical data were collected from 89 hospital-ized patients who underwent renal transplantation and developed hospital-associated infection at Beidaihe Rehabili-tation and Recuperation Center(formerly known as 281 Hospital)from 2017 to 2021.The pathogenic bacteria de-tected in different types of hospital-associated infections and the drug resistance of the main pathogenic bacteria were analyzed.RESULTS A total of 89 pathogenic bacterial strains were isolated from the 89 patients with hospi-tal-associated infection,including 74 gram-negative bacterial strains(83.15%)and 15 gram-positive bacterial strains(16.85%).The predominant pathogenic bacterial strains were Klebsiella pneumoniae,Escherichia coli and Pseudomonas aeruginosa.Respiratory tract infection was the most common.E.coli showed severe drug re-sistance,with high drug resistance rates to various antibacterial drugs(complete drug resistance to piperacillin and ampicillin).K.pneumoniae was generally drug resistant to ampicillin.Enterobacter cloacae showed high sensitivi-ty to carbapenems,amikacin and enzyme inhibitor combinations.P.aeruginosa had low drug resistance rates to imipenem and meropenem.Staphylococcus aureus was completely drug resistant to antibacterial drugs such as penicillin,erythromycin and gentamicin,and no drug-resistant strains to vancomycin and linezolid were found.CONCLUSIONS The gram-negative bacteria are dominant among the bacteria isolated from the renal trans-planted patients with postoperative hospital-associated infections,with a high detection rate of E.coli and a severe drug resistance situation.Therefore,it is necessary to strengthen the monitoring of drug resistance in renal trans-plant recipients and make rational choices of antibacterial drugs.
9.Distribution and drug resistance of pathogens isolated from renal transplantation patients with postoperative nosocomial infections
Zhina YANG ; Zhuo WANG ; Yingnan CHEN ; Chang LIU ; Xuefang BEN ; Minmin PENG
Chinese Journal of Nosocomiology 2025;35(12):1814-1817
OBJECTIVE To analyze the distribution and drug resistance of pathogenic bacteria in hospital-associat-ed infections for patients after renal transplantation,and to provide a reference for the rational selection of antibac-terial drugs for anti-infective treatment in such patients.METHODS Clinical data were collected from 89 hospital-ized patients who underwent renal transplantation and developed hospital-associated infection at Beidaihe Rehabili-tation and Recuperation Center(formerly known as 281 Hospital)from 2017 to 2021.The pathogenic bacteria de-tected in different types of hospital-associated infections and the drug resistance of the main pathogenic bacteria were analyzed.RESULTS A total of 89 pathogenic bacterial strains were isolated from the 89 patients with hospi-tal-associated infection,including 74 gram-negative bacterial strains(83.15%)and 15 gram-positive bacterial strains(16.85%).The predominant pathogenic bacterial strains were Klebsiella pneumoniae,Escherichia coli and Pseudomonas aeruginosa.Respiratory tract infection was the most common.E.coli showed severe drug re-sistance,with high drug resistance rates to various antibacterial drugs(complete drug resistance to piperacillin and ampicillin).K.pneumoniae was generally drug resistant to ampicillin.Enterobacter cloacae showed high sensitivi-ty to carbapenems,amikacin and enzyme inhibitor combinations.P.aeruginosa had low drug resistance rates to imipenem and meropenem.Staphylococcus aureus was completely drug resistant to antibacterial drugs such as penicillin,erythromycin and gentamicin,and no drug-resistant strains to vancomycin and linezolid were found.CONCLUSIONS The gram-negative bacteria are dominant among the bacteria isolated from the renal trans-planted patients with postoperative hospital-associated infections,with a high detection rate of E.coli and a severe drug resistance situation.Therefore,it is necessary to strengthen the monitoring of drug resistance in renal trans-plant recipients and make rational choices of antibacterial drugs.
10.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.

Result Analysis
Print
Save
E-mail