1.Preliminary Clinical Observation on the Implantation of AVEIR VR Single Chamber Leadless Pacemaker
Yi WEI ; Feng ZE ; Cuncao WU ; Cuizhen YUAN ; Ding LI ; Xuebin LI
Chinese Circulation Journal 2025;40(6):577-582
Objectives:To evaluate the performance of AVEIR VR single chamber leadless pacemaker(AVEIR VR)in the real world in China and the predictive factors of pacing threshold to assess the feasibility of AVEIRTM VR implantation in the domestic population.Methods:All patients who underwent AVEIR VR implantation by experienced operators from Peking University People's Hospital in multiple domestic hospitals from June 2024 to October 2024 were consecutively included,and their baseline characteristics,procedural data(including pacemaker electrical measurements at various stages),and follow-up results were observed,recorded,and statistically analyzed.Results:This study included 20 patients who met the indication for pacemaker implantation and underwent AVEIR VR implantation.Their mean age was(71.40±13.37)years,body mass index(BMI)was(23.05±3.71)kg/m2,body surface area(BSA)was(1.70±0.16)m2,all 20 patients were successfully implanted with pacemakers,there were no major complications(newly occurred pericardial effusion during the perioperative period,cardiac tamponade,poor pacemaker function,pacemaker dislocation/perforation,tricuspid valve injury,myocardial infarction,stroke,pulmonary embolism,and clinical death).One patient developed new frequent ventricular premature contractions after pacemaker release.The pacing threshold(PCT)at one week after implantation was correlated with PCT in tether mode(r=0.650,P=0.009)and PCT in release phase(r=0.596,P=0.019),but not with the sensing and impedance in each phase.Conclusions:This preliminary exploration study show that AVEIRTM VR implantation demonstrates satisfactory performance among real world patients in China,especially in elderly and low weight populations,confirming its safety.
2.Feasibility study of subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction
Cuizhen YUAN ; Feng ZE ; Ding LI ; Cuncao WU ; Jinshan HE ; Yi WEI ; Jingliang ZHOU ; Xuebin LI
Chinese Journal of Cardiology 2025;53(10):1141-1145
Objective:To evaluate the clinical feasibility of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation following transvenous lead extraction (TLE).Methods:This was a retrospective study. Consecutive patients who underwent S-ICD implantation at Peking University People′s Hospital between June 2015 and October 2023 were enrolled. Patients were divided into the TLE group and the newly implanted group based on whether they received TLE prior to S-ICD implantation. Baseline characteristics, S-ICD indication, defibrillation threshold test results, complications, and postoperative follow-up data were collected and compared between the two groups.Results:A total of 27 patients were included, aged (49.2±14.2) years, including 19 males. There were 12 patients in the TLE group and 15 in the newly implanted group. Compared with the TLE group, patients in the newly implanted group were younger ((43.3±13.7) years vs. (55.6±12.0) years, P=0.013). The main S-ICD indication in the TLE group was high infection risk (9/12), whereas in the newly implanted group it was younger age (11/15). All patients underwent successful S-ICD implantation, with 18 patients completing defibrillation threshold testing (all successful). Additionally, the TLE group had longer follow-up duration than the newly implanted group (42 (19, 60) months vs. 12 (3, 28) months, P=0.001). No complications or deaths occurred during follow-up, with normal device function in both groups. A total of 17 ventricular tachycardia or fibrillation events were recorded, of which 7 met defibrillation criteria and all received effective therapy. Conclusion:S-ICD demonstrates safety and efficacy as a therapeutic option for patients after TLE, with comparable device functionality and follow-up outcomes to patients with newly implanted S-ICD.
3.Preliminary Clinical Observation on the Implantation of AVEIR VR Single Chamber Leadless Pacemaker
Yi WEI ; Feng ZE ; Cuncao WU ; Cuizhen YUAN ; Ding LI ; Xuebin LI
Chinese Circulation Journal 2025;40(6):577-582
Objectives:To evaluate the performance of AVEIR VR single chamber leadless pacemaker(AVEIR VR)in the real world in China and the predictive factors of pacing threshold to assess the feasibility of AVEIRTM VR implantation in the domestic population.Methods:All patients who underwent AVEIR VR implantation by experienced operators from Peking University People's Hospital in multiple domestic hospitals from June 2024 to October 2024 were consecutively included,and their baseline characteristics,procedural data(including pacemaker electrical measurements at various stages),and follow-up results were observed,recorded,and statistically analyzed.Results:This study included 20 patients who met the indication for pacemaker implantation and underwent AVEIR VR implantation.Their mean age was(71.40±13.37)years,body mass index(BMI)was(23.05±3.71)kg/m2,body surface area(BSA)was(1.70±0.16)m2,all 20 patients were successfully implanted with pacemakers,there were no major complications(newly occurred pericardial effusion during the perioperative period,cardiac tamponade,poor pacemaker function,pacemaker dislocation/perforation,tricuspid valve injury,myocardial infarction,stroke,pulmonary embolism,and clinical death).One patient developed new frequent ventricular premature contractions after pacemaker release.The pacing threshold(PCT)at one week after implantation was correlated with PCT in tether mode(r=0.650,P=0.009)and PCT in release phase(r=0.596,P=0.019),but not with the sensing and impedance in each phase.Conclusions:This preliminary exploration study show that AVEIRTM VR implantation demonstrates satisfactory performance among real world patients in China,especially in elderly and low weight populations,confirming its safety.
4.Feasibility study of subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction
Cuizhen YUAN ; Feng ZE ; Ding LI ; Cuncao WU ; Jinshan HE ; Yi WEI ; Jingliang ZHOU ; Xuebin LI
Chinese Journal of Cardiology 2025;53(10):1141-1145
Objective:To evaluate the clinical feasibility of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation following transvenous lead extraction (TLE).Methods:This was a retrospective study. Consecutive patients who underwent S-ICD implantation at Peking University People′s Hospital between June 2015 and October 2023 were enrolled. Patients were divided into the TLE group and the newly implanted group based on whether they received TLE prior to S-ICD implantation. Baseline characteristics, S-ICD indication, defibrillation threshold test results, complications, and postoperative follow-up data were collected and compared between the two groups.Results:A total of 27 patients were included, aged (49.2±14.2) years, including 19 males. There were 12 patients in the TLE group and 15 in the newly implanted group. Compared with the TLE group, patients in the newly implanted group were younger ((43.3±13.7) years vs. (55.6±12.0) years, P=0.013). The main S-ICD indication in the TLE group was high infection risk (9/12), whereas in the newly implanted group it was younger age (11/15). All patients underwent successful S-ICD implantation, with 18 patients completing defibrillation threshold testing (all successful). Additionally, the TLE group had longer follow-up duration than the newly implanted group (42 (19, 60) months vs. 12 (3, 28) months, P=0.001). No complications or deaths occurred during follow-up, with normal device function in both groups. A total of 17 ventricular tachycardia or fibrillation events were recorded, of which 7 met defibrillation criteria and all received effective therapy. Conclusion:S-ICD demonstrates safety and efficacy as a therapeutic option for patients after TLE, with comparable device functionality and follow-up outcomes to patients with newly implanted S-ICD.
5.A Single-Arm Phase II Study of Nab-Paclitaxel Plus Gemcitabine and Cisplatin for Locally Advanced or Metastatic Biliary Tract Cancer
Ting LIU ; Qing LI ; Zhen LIN ; Chunhua LIU ; Wei PU ; Shasha ZENG ; Jun LAI ; Xuebin CAI ; Lisha ZHANG ; Shuyang WANG ; Miao CHEN ; Wei CAO ; Hongfeng GOU ; Qing ZHU
Cancer Research and Treatment 2024;56(2):602-615
Purpose:
Patients with advanced biliary tract cancer (BTC) have a poor survival. We aim to evaluate the efficacy and safety of nab-paclitaxel plus gemcitabine and cisplatin regimen in Chinese advanced BTC patients.
Materials and Methods:
Eligible patients with locally advanced or metastatic BTC administrated intravenous 100 mg/m2 nab-paclitaxel, 800 mg/m2 gemcitabine, and 25 mg/m2 cisplatin every 3 weeks. The primary endpoint was progression-free survival (PFS). The secondary endpoints included overall survival (OS) and adverse events, while exploratory endpoint was the association of biomarkers with efficacy.
Results:
After the median follow-up of 25.0 months, the median PFS and OS of 34 enrolled patients were 7.1 months (95% confidence interval [CI], 5.4 to 13.7) and 16.4 months (95% CI, 10.9 to 23.6), respectively. The most common treatment-related adverse events at ≥ 3 grade were neutropenia (26.5%) and leukopenia (26.5%). Survival analyses demonstrated that carcinoembryonic antigen (CEA) levels could monitor patients’ survival outcomes. A significant increase in the number of infiltrating CD4+ cells (p=0.008) and a decrease in programmed death-1–positive (PD-1+) cells (p=0.032) were observed in the response patients.
Conclusion
In advanced BTC patients, nab-paclitaxel plus gemcitabine and cisplatin regimen showed therapeutic potential. Potential prognostic factors of CEA levels, number of CD4+ cells and PD-1+ cells may help us maximize the efficacy benefit.
6.Identification and clearance of high-level drug-resistant Salmonella Kentucky ST198.2-1 from an occupational health examinee
Yan ZHONG ; Jingfang RUAN ; Xiachan QIN ; Bei WEI ; Yue LIU ; Min ZHOU ; Xuebin XU
Chinese Journal of Laboratory Medicine 2024;47(9):1094-1097
A 49-year-old female examinee, employed at a paper company in Guigang, Guangxi (engaged in the production of napkins), visited the Qintang District People′s Hospital in Guigang on June 11, 2023, to apply for a health certificate. Salmonella was isolated during a physical examination screening for enteric pathogens ( Salmonella, Shigella), and repeated use of empirical antibacterial drugs failed to eradicate the pathogen. A reference laboratory identified the two isolates as S. Kentucky ST198 by performing serotyping, drug resistance phenotyping, and whole genome sequencing. Based on the regional serotype database of Salmonella in China, a phylogenetic tree of S. Kentucky ST198 resistance genotypes was constructed, defining both isolated strains as high-level drug-resistant ST198.2-1 subclade clones. Following a multidisciplinary consultation and based on antimicrobial susceptibility test results, the treatment was adjusted to amoxicillin/clavulanate and azithromycin. On August 19, three consecutive negative test results confirmed the eradication of Salmonella Kentucky.
7.Campylobacter fetus subsp. fetus ST20 isolated and identified from the bacteremia patient
Bei WEI ; Fen GAO ; Yue LIU ; Yan ZHONG ; Yanfang LI ; Deju QIN ; Jincheng ZHOU ; Xuebin XU
Chinese Journal of Laboratory Medicine 2024;47(9):1102-1105
A 72-year-old female patient was admitted to the emergency department of Qintang District People′s Hospital of Guigang City in August 2023 due to chills and fever, abdominal distension and pain, diarrhea, cough and shortness of breath for 1 day. She had a history of chronic obstructive and pulmonary heart disease, stage Ⅲ hypertension, and ceftazidime allergy. Clinical diagnosis of acute bacterial infection of chronic obstructive pneumonia was made and levofloxacin combined with piperacillin/tazobactam were given as symptomatic treatment. The blood culture reported Campylobacter fetus after four days, and the patient was cured and discharged after seven days with negative blood culture. The morphology and mass spectrometry identification of the strain were consistent with the definition of Campylobacter fetus. Whole genome sequencing predicted the multi-site sequence type as Campylobacter fetus subsp. fetus( Cff) ST20, carrying the tetracycline resistance gene tet (O/M/O), 18 flagella genes (including rpoN gene from Campylobacter jejuni. these genes were not found in the other two Campylobacter fetus subspecies), and six virulence genes (including like-typhoidal toxin and typhoid toxin genes). The pathogen has the ecological characteristics of parasitic farmed animal colonization and the biological characteristics of high mobility and virulence. These attributes facilitated its entry into the bloodstream via the fecal-oral route, leading to invasive infections.
8.Analysis of Clinical Characteristics and Lead Extraction in Patients With Venous Occlusion Related to Infection of Cardiovascular Implantable Electronic Devices
Wenqiong ZHANG ; Feng ZE ; Ding LI ; Cuncao WU ; Xu ZHOU ; Yi WEI ; Xuebin LI
Chinese Circulation Journal 2024;39(9):859-864
Objectives:To assess the clinical characteristics and lead extraction in patients with venous occlusion related to infection of cardiovascular implantable electronic devices. Methods:Clinical data of 405 patients(147 men,mean age[62.4±13.2]years)who underwent lead extraction from January 2020 to January 2024 in Peking University People's Hospital were reviewed.Contrast venography of the access vein was retrospectively analyzed.The patients were divided into venous occlusion group(n=119)and non-venous occlusion group(n=286)according to the presence or absence of venous occlusion.The clinical characteristics and lead extraction of patients in two groups were analyzed. Results:Occlusion of the access vein occurred in 119 patients(29.4%).The subclavian vein was occluded in 48 cases(40.3%),brachiocephalic vein was occluded in 37 cases(31.1%),axillary vein was occluded in 30 cases(25.2%),superior vena cava was occluded in 4 cases(3.4%).There were no significant differences between venous occlusion group and non-venous occlusion group in terms of age,sex,device type,number of leads,or anticoagulation therapy(all P>0.05).Time from implant of the initial leads was significantly longer in the venous occlusion group than in the non-venous occlusion group([10.4±3.8]years vs.[5.9±4.1]years,P=0.042).Clinical extraction success rate and complications were similar between the venous occlusion group and the non-venous occlusion group(both P>0.05).Procedural duration and fluoroscopy exposure time were significantly lower in non-venous occlusion group than in the venous occlusion group(both P<0.05).Patients in the venous occlusion group required more advanced tools(such as laser sheaths,evolution sheaths,and needle's eye snares)for lead extraction compared to patients in the non-venous occlusion group(84.0%vs.67.1%,P=0.001). Conclusions:The incidence of venous occlusion related to infection of cardiovascular implantable electronic devices is 29.4%.Time from implant of the initial leads is significantly longer and lead extraction is more difficult in patients with venous occlusion,and requires more advanced tools and more time to achieve the successful lead extraction.
9.Relationship between non-high density lipoprotein cholesterol and leptomeningeal collaterals in patients with acute middle cerebral artery occlusion
Yi AN ; Yanfang YUN ; Guixin YANG ; Haiyan CHEN ; Yong-Ming JIANG ; Dongxu HUANG ; Xiaorong MO ; Xiaolan LI ; Baoyin WEI ; Yingjie ZHOU ; Xuebin LI ; Jianmin HUANG
The Journal of Practical Medicine 2023;39(24):3200-3204
Objective To explore the relationship between non-high density lipoprotein cholesterol(non-HDL-C)level and leptomeningeal collateral circulation in patients with acute middle cerebral artery occlusion.Methods A total of 85 patients with first-onset acute cerebral infarction with middle cerebral artery M1 segment occlusion were enrolled.According to the results of DSA,LMC circulation was assessed by American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology Collateral Circulation Assess-ment System.All patients were assigned to better LMC circulation group(score 2~4,n = 30)and worse LMC circulation group(score 0~1,n = 55),and the levels of non-HDL-C were compared between the two groups.Results The levels of LDL-C and non-HDL-C in worse LMC circulation group were significantly higher than those of the better LMC circulation group(P = 0.026,P = 0.010).non-HDL-C was an independent risk factor for the worse LMC circulation(OR = 3.019,95%CI:1.053~8.658,P = 0.04).LMC circulatory score of patients was negatively correlated with the levels of non-HDL-C level(r =-0.228,P = 0.036).The AUC of non-HDL-C predicted for the worse LMC circulation was 0.638(95%CI:0.521~0.755,P = 0.036).Conclusions non-HDL-C in patients with acute cerebral infarction was significantly related to worse LMC circulation,and was a risk factor for worse LMC circulation.It is suggested that the higher expression of non-HDL-C could be used to predict worse LMC circulation as a serological indicator.
10.Analysis on serotype and antimicrobial resistance of invasive non-typhoidal Salmonella
Yujie HU ; Xuebin XU ; Yan WANG ; Wei WANG ; Xinnan CUI ; Qiongyu HE ; Menghan LI ; Jin XU ; Fengqin LI
Chinese Journal of Epidemiology 2021;42(3):549-554
Objective:To investigate the serotypes and antimicrobial resistance of seven invasive non-typhoidal Salmonella (iNTS) isolates. Methods:For 7 iNTS strains collected, serotype identification, antimicrobial susceptibility testing and whole genome sequencing were performed. We identified, annotated and analyzed the serotypes, MLST types, and antimicrobial resistance genes.Results:Among the 7 tested iNTS isolates, we found one Salmonella Typhimurium strain and two Salmonella Ⅰ 4, [5], 12: i:- strains whose MLST types were ST34, two Salmonella Enteritidis strains, one Salmonella Corvallis strain and one strain of unknown serotype with the antigenic formulae of Ⅰ 4, [5], 12: d:- (ST279 type). Six of seven strains were monophasic and the deletion or pseudogenization of Salmonella Flagellum gene might contribute to the enhancement of Salmonella invasiveness. None was found to be resistant to tigarcycline, aztreonam, amikacin, cephalosporins and carbapenem and one Salmonella Typhimurium strain was found to be co-resistant to eight classes of antimicrobials at the same time. Resistance genes were generally in accord with relative resistant phenotypes. Conclusion:The iNTS strains could show high level multi-drug resistance, indicating that close attention should be paid to the resistance of iNTS though the overall resistance might be relatively not high.

Result Analysis
Print
Save
E-mail