1.Optimization of drug management model for investigator-initiated trial with benchmarking analysis
Yufei XI ; Tianxiao WANG ; Xue ZHANG ; Yingzhuo DING ; Li YAN ; Feng JIANG ; Xiangui HE ; Jiannan HUANG ; Qin LI
China Pharmacy 2025;36(3):280-284
OBJECTIVE To optimize the management model of drugs used in investigator-initiated trial (IIT). METHODS With benchmarking analysis, based on the practical work experience of a tertiary specialized hospital in the field of IIT drug management in Shanghai, a thorough review was conducted, involving relevant laws, regulations, and academic literature to establish benchmark criteria and the evaluation standards. Starting from the initiation of IIT projects, a detailed comparative analysis of key processes was carried out, such as the receipt, storage, distribution, use and recycling of drugs for trial. The deficiencies in the current management of IIT drugs were reviewed in detail and a series of optimization suggestions were put forward. RESULTS It was found that the authorized records of drug management were missing, the training before project implementation was insufficient, and the records of receipt and acceptance of IIT drugs were incomplete. In light of these existing problems, improvement measures were put forward, including strengthening the training of drug administrators and stipulating that only drug administrators with pharmacist qualifications be eligible to inspect and accept drugs, etc. The related systems were improved, and 17 key points of quality control for the management of IIT drugs were developed. CONCLUSIONS A preliminary IIT drug management system for medical institutions has been established, which helps to improve the institutional X2023076) framework of medical institutions in this field.
2.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Advances in molecular mechanisms and neuronal circuits underlying circadian rhythms in Drosophila.
Wu-Yan XU ; Chun-Xue QIAO ; Fei-Xiang LI ; Ding-Bang MA
Acta Physiologica Sinica 2025;77(4):627-640
Circadian rhythms are core regulatory mechanisms that evolved to align biological functions with the Earth's rotation. These rhythms are conserved across organisms from unicellular life to multicellular species and play essential roles in metabolism, immune responses, and sleep-wake cycle. Circadian disruptions are strongly associated with various diseases. Over the past decades, genetic studies in Drosophila and mice have identified key conserved clock genes and uncovered transcription-translation feedback loops governing circadian regulation. Additionally, rhythmic neurons in the brain integrate complex neural circuits to precisely regulate physiological and behavioral rhythms. This review highlights recent advances in understanding the neuronal circuit mechanisms of rhythmic neurons in the Drosophila brain and discusses future directions for translating circadian rhythm research into chronomedicine and precision therapies.
Animals
;
Circadian Rhythm/genetics*
;
Neurons/physiology*
;
Drosophila/physiology*
;
Brain/physiology*
;
Nerve Net/physiology*
9.Development and application of intensive care unit digital intelligence multimodal shift handover system.
Xue BAI ; Lixia CHANG ; Wei FANG ; Zhengang WEI ; Yan CHEN ; Zhenfeng ZHOU ; Min DING ; Hongli LIU ; Jicheng ZHANG
Chinese Critical Care Medicine 2025;37(10):950-955
OBJECTIVE:
To develop a digital intelligent multimodal shift handover system for the intensive care unit (ICU) and evaluate its application effect in ICU shift handovers.
METHODS:
A research and development team was established, consisting of 1 department director, 1 head nurse, 3 information technology engineers, 3 nurses, and 2 doctors. Team members were assigned responsibilities including overall coordination and planning, platform design and maintenance, pre-application training, collection and organization of clinical feedback, and research investigation respectively. A digital intelligent multimodal shift handover system was developed for ICU based on the Shannon-Weaver linear transmission model. This innovative system integrated automated data collection, intelligent dynamic monitoring, multidimensional condition analysis and visual reporting functions. A cloud platform was used to gather data from multi-parameter vital signs monitors, infusion pumps, ventilators and other devices. Artificial intelligence algorithms were employed to standardize and analyze the data, providing personalized recommendations for healthcare professionals. A self-controlled before-after method was adopted. Before the application of the ICU digital intelligent multimodal shift handover system (from December 2023 to March 2024), the traditional verbal bedside handover was used; from June 2024 to March 2025, the ICU digital intelligent multimodal shift handover system was applied for shift handovers. Questionnaires before the application of the shift handover system were collected in April 2024, and those after the application were collected in April 2025. The shift handover time, handover quality (scored by the nursing handover evaluation scale), satisfaction with doctor-nurse communication (scored by the ICU doctor-nurse scale) before and after the application of the handover system were compared, and nurses' satisfaction with the shift handover system (scored by the clinical nursing information system effectiveness evaluation scale) was investigated.
RESULTS:
After the application of the ICU digital intelligent multimodal shift handover system, the shift handover time was significantly shorter than that before the application [minutes: 20 (15, 25) vs. 30 (22, 40)], the handover quality was significantly higher than that before the application [score: 84.0 (78.0, 88.5) vs. 71.0 (55.0, 79.0)], and the satisfaction with doctor-nurse communication was also significantly higher than that before the application (score: 84.58±6.79 vs. 74.50±11.30). All differences were statistically significant (all P < 0.05). In addition, the nurses' system effectiveness evaluation scale score was 102.30±10.56, which indicated that nurses had a very high level of satisfaction with the ICU digital intelligent multimodal shift handover system.
CONCLUSIONS
The application of the ICU digital intelligent multimodal shift handover system can shorten the shift handover time, improve the handover quality, and enhance the satisfaction with doctor-nurse communication. Nurses have a high level of satisfaction with this system.
Intensive Care Units
;
Humans
;
Patient Handoff
;
Artificial Intelligence
;
Algorithms
10.Short-term Effects of Fine Particulate Matter and its Constituents on Acute Exacerbations of Chronic Bronchitis: A Time-stratified Case-crossover Study.
Jing Wei ZHANG ; Jian ZHANG ; Peng Fei LI ; Yan Dan XU ; Xue Song ZHOU ; Xiu Li TANG ; Jia QIU ; Zhong Ao DING ; Ming Jia XU ; Chong Jian WANG
Biomedical and Environmental Sciences 2025;38(3):389-393

Result Analysis
Print
Save
E-mail