1.The Mechanism of Echinococcus Granulosus Sensu Stricto Antigen B to Protect Immune Thrombocytopenia Mouse Model by Influen-cing Autophagy
Hai-Chen SONG ; Xue-Mei WANG ; Dan-Lu LI ; Li ZHAO ; Xue-Hua YANG ; Mei YAN
Journal of Experimental Hematology 2025;33(6):1694-1700
Objective:To investigate the mechanism of natural antigen B(nAgB)to protect Immune thrombocytopenia(ITP)mouse model by influencing autophagy.Methods:Twenty-eight female BALB/c mice aged 8-10 weeks were randomly divided into four groups.7 mice of each group were immunized intraperitoneally,the control group was treated with PBS as the control group;ITP group was treated with anti-CD41 monoclonal antibody(anti-CD41Ab)only;nAgB group was treated with nAgB intraperitoneal injection for 5d;nAgB+ITP group was treated with nAgB intraperitoneal injection for 5d,then treated with anti-CD41 Ab.The peripheral blood platelet count in each group was tested;and the spleen and liver should be isolated and weighed,the organ index was calculated;qRT-PCR was used to detect spleen microtubule-associated protein 1 light chain 3(LC3),p62,Beclin-1 mRNA expression levels.Western blot was used to detect the protein expression level of spleen LC3 Ⅱ/LC3 Ⅰ,p62,Beclin-1.Results:Compared with the control group,mice in the ITP group showed a significant decrease in blood PLT count[(102.1±17.9)× 109/L vs(485.4±185.2)×109/L,P<0.01],a significant increase in spleen index(P<0.01),mice in the nAgB group showed a significant increase in blood PLT count,rising to(1051±127.6)× 109/L on the 3 day after modeling.Compared with the ITP group,mice in the nAgB+ITP group showed a significant increase in PLT count on the 1 day of anti-CD41 Ab administration[(428.6±131.6)× 109/L vs(102.1±17.9)×109/L,P<0.05],however,the spleen index was significantly decreased(P<0.05).qRT-PCR and Western blot results showed that compared with the control group,the mRNA and protein expression levels of spleen LC3,p62 and Beclin-1 were increased in the ITP group of mice(P<0.05,P<0.01).Compared with the ITP group,the nAgB+ITP group could significantly decrease mRNA levels of spleen LC3,p62 and Beclin-1(P<0.05,P<0.01),and also significantly decrease the protein expression levels of LC3 Ⅱ/LC3 Ⅰ,p62 and Beclin-1(P<0.05,P<0.01).Conclusion:nAgB inhibits the transcription and expression levels of autophagy-related genes and regulates immune intolerance,thereby protecting ITP mouse models.
2.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
3.Effect of miR-129-3p mimetic on bone loss in tail-suspended mice
Yi WU ; Zi-dong AN ; Yong-jie PANG ; Li-qiang WANG ; Xin-yang WANG ; Yu-hai GAO ; Xue-yan LI ; Ke-ming CHEN
Chinese Pharmacological Bulletin 2025;41(4):703-709
Aim To study whether intravenous injec-tion of miR-129-3p mimetic(agomir)can resist bone loss caused by hind limb disuse,and to provide new i-deas for preventing bone loss in microgravity environ-ment.Methods Forty-eight C57BL/6J male mice were randomly divided into the control group(CON),tail suspension model group(TS),tail suspension+miR-129-3p agomir administration group(miRNA)and tail suspension+miR-129-3p negative sequence agomir control group(NC).The miRNA group was given 4 mg·kg-1 miR-129-3p agomir by intravenous injection into the medial canthus twice a week.The NC agomir group were consistent with those in the miR-129-3p agomir group,and the CON and TS groups were given only equal volumes of normal saline.After four weeks,all mice were sacrificed and samples were collected.Micro-CT scan of femur,three-point femur bending test,serum bone metabolism index detection,oxidative stress index detection and osteogenesis-related protein expression analysis in bone tissue were per-formed.Results After four weeks,the number of tra-becular bone in the TS group was significantly re-duced,and Tb.BMD,Tb.Th,Tb.N,Tb.BS/TV and Tb.BV/TV were significantly lower than those in the CON group(P<0.01).While Tb.Sp TS group was significantly higher than the CON group(P<0.05),the maximum load and flexural strength of the femur significantly decreased(P<0.01),the content of ser-um bone formation index PINP was significantly lower than that of the CON group(P<0.01),and the con-tent of bone resorption index CTX-I was significantly higher than that of the CON group(P<0.01),the content of serum oxidative damage indexes 8-iso-PGF2α and 8-OHdG significantly increased(P<0.01),and the expression of osteogenesis-related pro-teins in bone tissue markedly decreased(P<0.01).However,the increase or decrease of all indexes in miRNA group was significantly lower than that in TS group.Conclusions miR-129-3p mimetic can signifi-cantly reduce bone loss caused by hind limb disuse.This experiment provides a new idea and method for preventing bone loss in microgravity environment.
4.Chemical contituents from Dictamni Cortex
Yan LIU ; Tian-tian WEN ; Ye SUN ; Qing-shan CHEN ; Li-li ZHANG ; Hai-xue KUANG ; Bing-you YANG
Chinese Traditional Patent Medicine 2025;47(3):812-821
AIM To study the chemical constituents from Dictamni Cortex.METHODS The 70%ethanol extract from Dictamni Cortex was isolated and purified by HP-20 macroporous resin,silica gel,MCI,ODS and preparative HPLC,then the structures of obtained compounds were identified by physicochemical properties and spectral data.RESULTS Thirty-three compounds were isolated and identified as rutin(1),apigenin(2),catechin(3),hesperetin(4),leonuriside A(5),androsin(6),2-methoxy-4-acetylphenol-O-α-rhamnopyranosyl-(1"-6')-β-glucopyranoside(7),vanillic acid(8),gallic acid(9),4-hydroxybenzoic acid(10),benzoic acid(11),involcranoside B(12),benzyl β-D-glucopyranoside(13),bphenylethyl-rutinoside(14),1-bromonaphthalene(15),cimifugin(16),9(S),12(S),13(S)-trihydroxyoctadeca-10(E),15(Z)-dienoic acid(17),methyl-9,12,13-trihydroxyoctadeca-10,15-dienoate(18),7,8-dihydroxy-9,12(Z,Z)-octadecadienoic acid(19),vernolic acid(20),9,10(erythro)-dihydroxy-11 E-octadecadienoic acid methyl ester(21),(7Z,9E,13Z)-11-hydroxyhexadeca-7,9,13-trienoic acid(22),(7Z,10Z,14E,16Z,19Z)-13-hydroxydocosa-7,10,14,16,19-pentaenoic acid(23),(9E)-8,11,12-trihydroxyoctadecenoic acid methyl ester(24),n-hexanol-O-rutinoside(25),hexyl β-sophoroside(26),3-pentyl 6'-(3-hydroxy-3-methylglutaryl)-β-D-glucopyranoside(27),3-methylbut-3-enyl-6-O-β-D-glucopyranosyl-β-D-glucopyranoside(28),3-methyl-but-2-en-1-yl β-D-glucopyranoside(29),3-methylbutan-1-ol-β-D-glucopyranoside(30),pregnenolone(31),2-butoxytetrahydrofuran(32),psydrin(33).CONCLUSION Compounds 2-4,8-13,15-16,25-28 and 32-33 are isolated from Rutaceae family for the first time.
5.Comparison of left ventricular reverse remodeling and prognosis after transcatheter aortic valve replacement in aortic stenosis and mixed aortic valve disease
Meng SUN ; Lu-lin CHEN ; Jing-yun BAI ; Li-jie YAN ; Jing-jing LIU ; Xian-wei FAN ; Xue-jie LI ; Juan HU ; Jin-tao WU ; Hai-tao YANG
Chinese Journal of Interventional Cardiology 2025;33(2):71-78
Objective To evaluate the effects of transcatheter aortic valve replacement(TAVR)on left ventricular reverse remodeling(LVRR)and outcomes in patients with mixed aortic valve disease(MAVD)and predominant aortic stenosis(AS).Methods Patients undergoing TAVR at our center between January 2020 and December 2022 were enrolled consecutively.Propensity score matching(PSM)(1∶1 ratio)was used to reduce selection bias.Transthoracic echocardiography(TTE)was used to monitor left ventricular ejection fraction(LVEF)and other structural parameters over time.The study outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes.Linear mixed-effects models and logistic regression were utilized for comparing echocardiographic changes across groups and identifying independent risk factors for no-LVRR,respectively.Results After PSM,126 patients were included.MAVD group exhibited larger structural parameters(left ventricular end-systolic/end-diastolic diameter and volume,left ventricular mass index)and a lower left ventricular ejection fraction(LVEF)(all P<0.05).However,more pronounced improvements in left ventricular structure and hemodynamics were observed during follow-up.Multivariate logistic regression analysis indicated that the left ventricular mass index(LVMI)was an independent predictor of left ventricular reverse remodeling(LVRR)after TAVR,whereas persistent moderate or greater mitral regurgitation(MR)and paravalvular leak(PVL)significantly reduced the incidence of LVRR.During a median follow-up period of 23 months,a total of 31 endpoint events occurred,and there was no statistically significant difference in long-term prognosis between the two groups(Log-rank P=0.330).Conclusions Compared to patients in the AS group,those in the MAVD group exhibited more severe left ventricular remodeling before TAVR.However,more significant LVRR was observed during postoperative follow-up.Additionally,the long-term prognosis was comparable between the two groups.
6.Comparison of left ventricular reverse remodeling and prognosis after transcatheter aortic valve replacement in aortic stenosis and mixed aortic valve disease
Meng SUN ; Lu-lin CHEN ; Jing-yun BAI ; Li-jie YAN ; Jing-jing LIU ; Xian-wei FAN ; Xue-jie LI ; Juan HU ; Jin-tao WU ; Hai-tao YANG
Chinese Journal of Interventional Cardiology 2025;33(2):71-78
Objective To evaluate the effects of transcatheter aortic valve replacement(TAVR)on left ventricular reverse remodeling(LVRR)and outcomes in patients with mixed aortic valve disease(MAVD)and predominant aortic stenosis(AS).Methods Patients undergoing TAVR at our center between January 2020 and December 2022 were enrolled consecutively.Propensity score matching(PSM)(1∶1 ratio)was used to reduce selection bias.Transthoracic echocardiography(TTE)was used to monitor left ventricular ejection fraction(LVEF)and other structural parameters over time.The study outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes.Linear mixed-effects models and logistic regression were utilized for comparing echocardiographic changes across groups and identifying independent risk factors for no-LVRR,respectively.Results After PSM,126 patients were included.MAVD group exhibited larger structural parameters(left ventricular end-systolic/end-diastolic diameter and volume,left ventricular mass index)and a lower left ventricular ejection fraction(LVEF)(all P<0.05).However,more pronounced improvements in left ventricular structure and hemodynamics were observed during follow-up.Multivariate logistic regression analysis indicated that the left ventricular mass index(LVMI)was an independent predictor of left ventricular reverse remodeling(LVRR)after TAVR,whereas persistent moderate or greater mitral regurgitation(MR)and paravalvular leak(PVL)significantly reduced the incidence of LVRR.During a median follow-up period of 23 months,a total of 31 endpoint events occurred,and there was no statistically significant difference in long-term prognosis between the two groups(Log-rank P=0.330).Conclusions Compared to patients in the AS group,those in the MAVD group exhibited more severe left ventricular remodeling before TAVR.However,more significant LVRR was observed during postoperative follow-up.Additionally,the long-term prognosis was comparable between the two groups.
7.In vivo effects of albendazole-glucan particles in the treatment of secondary Echinococcus metacestode infections in mice
Hai-shan YANG ; Sheng-xue LI ; Hai-xia ZHANG ; Hong-chang ZHAO ; Tong-chuan XING ; Xi-chen WU ; Xiang ZHANG ; Yan LIU
Chinese Journal of Zoonoses 2025;41(1):15-22
Albendazole-glucan particles(ABZ-GPS)and abendazole(ABZ)were used to treat secondary alveolar echinococ-cosis in mice.The therapeutic effects of ABZ-GPS on alveolar echinococcosis in vivo were evaluated,and the feasibility of using glucan particles as anti-hydatid drug carriers was further verified.Mice with echinococcosis were randomly divided into an ABZ group,glucan nanoparticle(GP)group,ABZ-GPS group,and control group.After four courses of administration with a final concentration of 50 mg/mL,the therapeutic effects of ABZ-GPS were evaluated on the basis of imaging,histopathological changes,ultrastructure,and immunology.After ABZ-GPS and ABZ administration,clear liver lesion tissue necrosis and large numbers of infiltrating lymphocytes were observed.Significant differences in the average cyst wet weight(t=7.83,P<0.05),were observed between the ABZ-GPS group and ABZ group.Imaging revealed that ABZ-GPs were targeted to liver tissue.Pa-thology and ultrastructure analyses demonstrated that the alveolar hydatid cells in the liver in the control group and GP group grew well,and the vesicles were large,filled with cystic fluid,and translucent or transparent;the cyst wall tension was high;no calcification was observed;the stratum corneum and germinal layer were clear;and more fertile capsules and different num-bers of protocephalospora were present in the liver.In the ABZ group,the capsular cavity collapsed,and showed partial necro-sis and lymphocyte infiltration.In the ABZ-GP group,the corneum and germinal layer of echinococcus vesicles were difficult to identify,and we observed bulbous necrosis,central calcification,fibrous tissue hyperplasia,inflammatory cell infiltration,coarser,shorter or absent microvilli of the germinal layer,nuclear shrinkage,dissolution or disappearance,clear expansion of cytoplasmic microtubules,and myelin-like or vacuole-like changes.Therefore,ABZ-GPs showed good targeting and killing ac-tivity in vivo in mice with secondary alveolar coccosis.
8.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
9.The Mechanism of Echinococcus Granulosus Sensu Stricto Antigen B to Protect Immune Thrombocytopenia Mouse Model by Influen-cing Autophagy
Hai-Chen SONG ; Xue-Mei WANG ; Dan-Lu LI ; Li ZHAO ; Xue-Hua YANG ; Mei YAN
Journal of Experimental Hematology 2025;33(6):1694-1700
Objective:To investigate the mechanism of natural antigen B(nAgB)to protect Immune thrombocytopenia(ITP)mouse model by influencing autophagy.Methods:Twenty-eight female BALB/c mice aged 8-10 weeks were randomly divided into four groups.7 mice of each group were immunized intraperitoneally,the control group was treated with PBS as the control group;ITP group was treated with anti-CD41 monoclonal antibody(anti-CD41Ab)only;nAgB group was treated with nAgB intraperitoneal injection for 5d;nAgB+ITP group was treated with nAgB intraperitoneal injection for 5d,then treated with anti-CD41 Ab.The peripheral blood platelet count in each group was tested;and the spleen and liver should be isolated and weighed,the organ index was calculated;qRT-PCR was used to detect spleen microtubule-associated protein 1 light chain 3(LC3),p62,Beclin-1 mRNA expression levels.Western blot was used to detect the protein expression level of spleen LC3 Ⅱ/LC3 Ⅰ,p62,Beclin-1.Results:Compared with the control group,mice in the ITP group showed a significant decrease in blood PLT count[(102.1±17.9)× 109/L vs(485.4±185.2)×109/L,P<0.01],a significant increase in spleen index(P<0.01),mice in the nAgB group showed a significant increase in blood PLT count,rising to(1051±127.6)× 109/L on the 3 day after modeling.Compared with the ITP group,mice in the nAgB+ITP group showed a significant increase in PLT count on the 1 day of anti-CD41 Ab administration[(428.6±131.6)× 109/L vs(102.1±17.9)×109/L,P<0.05],however,the spleen index was significantly decreased(P<0.05).qRT-PCR and Western blot results showed that compared with the control group,the mRNA and protein expression levels of spleen LC3,p62 and Beclin-1 were increased in the ITP group of mice(P<0.05,P<0.01).Compared with the ITP group,the nAgB+ITP group could significantly decrease mRNA levels of spleen LC3,p62 and Beclin-1(P<0.05,P<0.01),and also significantly decrease the protein expression levels of LC3 Ⅱ/LC3 Ⅰ,p62 and Beclin-1(P<0.05,P<0.01).Conclusion:nAgB inhibits the transcription and expression levels of autophagy-related genes and regulates immune intolerance,thereby protecting ITP mouse models.
10.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]

Result Analysis
Print
Save
E-mail