1.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
3.Application of genome tagging technology in elucidating the function of sperm-specific protein 411 (Ssp411).
Xue-Hai ZHOU ; Min-Min HUA ; Jia-Nan TANG ; Bang-Guo WU ; Xue-Mei WANG ; Chang-Gen SHI ; Yang YANG ; Jun WU ; Bin WU ; Bao-Li ZHANG ; Yi-Si SUN ; Tian-Cheng ZHANG ; Hui-Juan SHI
Asian Journal of Andrology 2025;27(1):120-128
The genome tagging project (GTP) plays a pivotal role in addressing a critical gap in the understanding of protein functions. Within this framework, we successfully generated a human influenza hemagglutinin-tagged sperm-specific protein 411 (HA-tagged Ssp411) mouse model. This model is instrumental in probing the expression and function of Ssp411. Our research revealed that Ssp411 is expressed in the round spermatids, elongating spermatids, elongated spermatids, and epididymal spermatozoa. The comprehensive examination of the distribution of Ssp411 in these germ cells offers new perspectives on its involvement in spermiogenesis. Nevertheless, rigorous further inquiry is imperative to elucidate the precise mechanistic underpinnings of these functions. Ssp411 is not detectable in metaphase II (MII) oocytes, zygotes, or 2-cell stage embryos, highlighting its intricate role in early embryonic development. These findings not only advance our understanding of the role of Ssp411 in reproductive physiology but also significantly contribute to the overarching goals of the GTP, fostering groundbreaking advancements in the fields of spermiogenesis and reproductive biology.
Animals
;
Female
;
Humans
;
Male
;
Mice
;
Spermatids/metabolism*
;
Spermatogenesis/physiology*
;
Spermatozoa/metabolism*
;
Thioredoxins/genetics*
4.The systemic inflammatory response index as a risk factor for all-cause and cardiovascular mortality among individuals with coronary artery disease: evidence from the cohort study of NHANES 1999-2018.
Dao-Shen LIU ; Dan LIU ; Hai-Xu SONG ; Jing LI ; Miao-Han QIU ; Chao-Qun MA ; Xue-Fei MU ; Shang-Xun ZHOU ; Yi-Xuan DUAN ; Yu-Ying LI ; Yi LI ; Ya-Ling HAN
Journal of Geriatric Cardiology 2025;22(7):668-677
BACKGROUND:
The association of systemic inflammatory response index (SIRI) with prognosis of coronary artery disease (CAD) patients has never been investigated in a large sample with long-term follow-up. This study aimed to explore the association of SIRI with all-cause and cause-specific mortality in a nationally representative sample of CAD patients from United States.
METHODS:
A total of 3386 participants with CAD from the National Health and Nutrition Examination Survey (NHANES) 1999-2018 were included in this study. Cox proportional hazards model, restricted cubic spline (RCS), and receiver operating characteristic curve (ROC) were performed to investigate the association of SIRI with all-cause and cause-specific mortality. Piece-wise linear regression and sensitivity analyses were also performed.
RESULTS:
During a median follow-up of 7.7 years, 1454 all-cause mortality occurred. After adjusting for confounding factors, higher lnSIRI was significantly associated with higher risk of all-cause (HR = 1.16, 95% CI: 1.09-1.23) and CVD mortality (HR = 1.17, 95% CI: 1.05-1.30) but not cancer mortality (HR = 1.17, 95% CI: 0.99-1.38). The associations of SIRI with all-cause and CVD mortality were detected as J-shaped with threshold values of 1.05935 and 1.122946 for SIRI, respectively. ROC curves showed that lnSIRI had robust predictive effect both in short and long terms.
CONCLUSIONS
SIRI was independently associated with all-cause and CVD mortality, and the dose-response relationship was J-shaped. SIRI might serve as a valid predictor for all-cause and CVD mortality both in the short and long terms.
5.Research on Detection Method for Constituent Content of Fresh Tea Leaf Based on Residual Attention Convolutional Neural Network
Hai-Liang ZHANG ; Yan ZHOU ; Wei LUO ; Bai-Shao ZHAN ; Jing ZHANG ; Xue-Mei LIU
Chinese Journal of Analytical Chemistry 2025;53(5):842-851
The rapid and non-destructive detection of constituent content of fresh tea leaves shows an important reference value for quality identification of tea.Visible near infrared(Vis-NIR)spectroscopy has been used for qualitative and quantitative analysis of chemical components in plant samples with the advantages such as simple,rapid and non-destructive detection.In this study,residual attention convolutional neural network(RACNN)was used to predict the internal constituent content of fresh tea leaves.Firstly,the reflectance spectral data of the samples in the Vis-NIR band range and the constituent contents of gallic acid(GA),gallocatechin(GC),epigallocatechin(EGC),and epigallocatechin gallate(ECG)in fresh tea leaves were collected.Based on the preprocessing of the spectral data,the contents of the four components were predicted using a partial least squares regression(PLSR)model,and the optimal preprocessing was determined.Subsequently,the characteristic bands were extracted using the random forest(RF)algorithm.Finally,the performances of PLSR,convolutional neural network(CNN)and RACNN models were compared.The results showed that for GA,the RACNN model worked best with a validation set coefficient of determination(R2)of 0.946 and a root mean square error of the prediction set(RMSEP)of 1.173;for GC,the RACNN model works best with a validation set R2 of 0.928 and RMSEP of 6.081;for EGC,the RACNN model works best with a validation set R2 of 0.891 and a RMSEP of 15.197;for ECG,the RACNN model worked best with a validation set R2 of 0.878 and a RMSEP of 7.837.The RACNN model established by Vis-NIR spectroscopy combined with chemometrics could realize the accurate detection of the contents of components in fresh tea.
6.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
7.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets
8.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
9.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
10.Case Analysis of MYH9-Related Disease with Non-Hodgkin Lymphoma Caused by Rare Mutations
Xue-Ting KONG ; Dan-Yu WANG ; Ze-Lin LIU ; Zhao-Gui ZHOU ; Nan ZHONG ; Lei LIU ; Meng-Di JIN ; Hai-Yan CUI
Journal of Experimental Hematology 2025;33(4):1145-1149
Objective:To analyze the MYH9 gene sequence of a patient with hereditary thrombocytopenia and diffuse large B-cell lymphoma and his family members,and to explore the relationship between MYH9 gene and tumors.Methods:Peripheral blood samples were collected from the patients and their family members for complete blood count analysis.The platelet morphology was observed under microscope.The MYH9 gene sequence was analyzed by Whole Exon Sequencing and Sanger Sequencing.Results:The mutation site c.279C>A:p.(Asn93Lys)in exon 2 of the MYH9 gene were found in patient and his family members,both presenting as thrombocytopenia.The platelet count was significantly increased after the administration of Avatrombopag.Conclusion:A novel mutation of MYH9 was found in this study,and the case was sensitive to Avatrombopag,by exploring the relationship between the MYH9 gene and tumors,suggesting that the MYH9 gene may be associated with the development of diffuse large B-cell lymphoma.

Result Analysis
Print
Save
E-mail