1.Gradient artificial bone repair scaffold regulates skeletal system tissue repair and regeneration
Yu ZHANG ; Ruian XU ; Lei FANG ; Longfei LI ; Shuyan LIU ; Lingxue DING ; Yuexi WANG ; Ziyan GUO ; Feng TIAN ; Jiajia XUE
Chinese Journal of Tissue Engineering Research 2025;29(4):846-855
BACKGROUND:Gradient artificial bone repair scaffolds can mimic unique anatomical features in musculoskeletal tissues,showing great potential for repairing injured musculoskeletal tissues. OBJECTIVE:To review the latest research advances in gradient artificial bone repair scaffolds for tissue engineering in the musculoskeletal system and describe their advantages and fabrication strategies. METHODS:The first author of the article searched the Web of Science and PubMed databases for articles published from 2000 to 2023 with search terms"gradient,bone regeneration,scaffold".Finally,76 papers were analyzed and summarized after the screening. RESULTS AND CONCLUSION:(1)As an important means of efficient and high-quality repair of skeletal system tissues,gradient artificial bone repair scaffolds are currently designed bionically for the natural gradient characteristics of bone tissue,bone-cartilage,and tendon-bone tissue.These scaffolds can mimic the extracellular matrix of native tissues to a certain extent in terms of structure and composition,thus promoting cell adhesion,migration,proliferation,differentiation,and regenerative recovery of damaged tissues to their native state.(2)Advanced manufacturing technology provides more possibilities for gradient artificial bone repair scaffold preparation:Gradient electrospun fiber scaffolds constructed by spatially differentiated fiber arrangement and loading of biologically active substances have been developed;gradient 3D printed scaffolds fabricated by layered stacking,graded porosity,and bio-3D printing technology;gradient hydrogel scaffolds fabricated by in-situ layered injections,simple layer-by-layer stacking,and freeze-drying method;and in addition,there are also scaffolds made by other modalities or multi-method coupling.These scaffolds have demonstrated good biocompatibility in vitro experiments,were able to accelerate tissue regeneration in small animal tests,and were observed to have significantly improved histological structure.(3)The currently developed gradient artificial bone repair scaffolds have problems such as mismatch of gradient scales,unclear material-tissue interactions,and side effects caused by degradation products,which need to be further optimized by combining the strengths of related disciplines and clinical needs in the future.
2.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
3.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
4.Radiation dose measurement for breast cone-beam CT-scanned examinees based on ART phantom of breast
Ke XUE ; Hui XU ; Zechen FENG ; Baorong YUE ; Yanqiu DING ; Zhaoxiang YE
Chinese Journal of Radiological Medicine and Protection 2025;45(2):122-128
Objective:To measure and estimate the radiation dose to breast cone-beam CT (CBCT) -scanned examinees, which can provide a dose reference for the selection of mammography equipment in the clinic.Methods:In this study, using a 400 cm 3 Alderson radiation therapy (ART) breast phantom and thermoluminescent detectors (TLDs), the distribution of absorbed dose, and the average glandular dose (AGD), to the examined breasts caused by a breast CBCT scanner was measured and calculated scanner at 50 and 100 mA tube currents. Results:At 50 and 100 mA tube currents, the range of breast absorbed dose inside the examined breast measured based on the phantom was 2.25-7.97 mGy and 3.88-15.68 mGy, respectively, with breast absorbed dose decreasing from the periphery to the centre of the phantom, and the related AGDs were 4.87 and 9.81 mGy, respectively.Conclusions:The AGDs to the breast of CBCT-scanned examinees measured in this study was higher than in the case of commonly used digital mammography. This will be meaningful to provide the guidance on the rational choice of imaging equipment in future clinical practice.
5.Application value of intestinal stent placement assisted by disposable subscope for acute malignant colorectal obstruction (with video)
Yuanzhi WANG ; Bengang ZHOU ; Bangjie LIU ; Guanghuai YAO ; Guiqing LI ; Yaoyao LI ; Feng XUE ; Ming ZHOU ; Yanbing DING
Chinese Journal of Digestive Endoscopy 2025;42(9):722-726
To investigate the application value of disposable subscope-assisted intestinal metal stent placement in the treatment for acute malignant colorectal obstruction, a retrospective analysis was conducted on the patients who underwent intestinal metal stent placement assisted by disposable subscope for acute malignant colorectal obstruction at the Digestive Endoscopy Center, Affiliated Hospital of Yangzhou University from June 2023 to July 2024. The technical success rate, clinical success rate, operation time, postoperative complications and first-stage surgical resection anastomosis rate of intestinal metal stent placement assisted by subscope were analyzed. Among the 16 included patients, there were 10 males and 6 females, with the age of 72.19±9.40 years. Obstruction occurred at the descending colon in 8 cases (50.00%), at the sigmoid colon in 6 cases (37.50%), at the rectosigmoid junction in 1 case (6.25%), and at the splenic flexure of the transverse colon in 1 case (6.25%). All 16 patients successfully underwent stent placement, with a technical success rate of 100.00% (16/16). Obstruction symptoms did not relieve in one patient (6.25%) after stent placement, resulting in a clinical success rate of 93.75% (15/16). The endoscopic operation time for the 16 patients was 37.8±13.9 minutes. No bleeding, perforation, stent displacement, or detachment occurred after the operation. Fourteen patients underwent subsequent surgical treatment, the first-stage surgical resection anastomosis rate was 71.43% (10/14). This preliminary study suggests that the disposable subscope-assisted intestinal metal stent placement for the treatment of acute malignant colorectal obstruction is safe and effective, with no radiation exposure.
6.Radiation dose measurement for breast cone-beam CT-scanned examinees based on ART phantom of breast
Ke XUE ; Hui XU ; Zechen FENG ; Baorong YUE ; Yanqiu DING ; Zhaoxiang YE
Chinese Journal of Radiological Medicine and Protection 2025;45(2):122-128
Objective:To measure and estimate the radiation dose to breast cone-beam CT (CBCT) -scanned examinees, which can provide a dose reference for the selection of mammography equipment in the clinic.Methods:In this study, using a 400 cm 3 Alderson radiation therapy (ART) breast phantom and thermoluminescent detectors (TLDs), the distribution of absorbed dose, and the average glandular dose (AGD), to the examined breasts caused by a breast CBCT scanner was measured and calculated scanner at 50 and 100 mA tube currents. Results:At 50 and 100 mA tube currents, the range of breast absorbed dose inside the examined breast measured based on the phantom was 2.25-7.97 mGy and 3.88-15.68 mGy, respectively, with breast absorbed dose decreasing from the periphery to the centre of the phantom, and the related AGDs were 4.87 and 9.81 mGy, respectively.Conclusions:The AGDs to the breast of CBCT-scanned examinees measured in this study was higher than in the case of commonly used digital mammography. This will be meaningful to provide the guidance on the rational choice of imaging equipment in future clinical practice.
7.Application value of intestinal stent placement assisted by disposable subscope for acute malignant colorectal obstruction (with video)
Yuanzhi WANG ; Bengang ZHOU ; Bangjie LIU ; Guanghuai YAO ; Guiqing LI ; Yaoyao LI ; Feng XUE ; Ming ZHOU ; Yanbing DING
Chinese Journal of Digestive Endoscopy 2025;42(9):722-726
To investigate the application value of disposable subscope-assisted intestinal metal stent placement in the treatment for acute malignant colorectal obstruction, a retrospective analysis was conducted on the patients who underwent intestinal metal stent placement assisted by disposable subscope for acute malignant colorectal obstruction at the Digestive Endoscopy Center, Affiliated Hospital of Yangzhou University from June 2023 to July 2024. The technical success rate, clinical success rate, operation time, postoperative complications and first-stage surgical resection anastomosis rate of intestinal metal stent placement assisted by subscope were analyzed. Among the 16 included patients, there were 10 males and 6 females, with the age of 72.19±9.40 years. Obstruction occurred at the descending colon in 8 cases (50.00%), at the sigmoid colon in 6 cases (37.50%), at the rectosigmoid junction in 1 case (6.25%), and at the splenic flexure of the transverse colon in 1 case (6.25%). All 16 patients successfully underwent stent placement, with a technical success rate of 100.00% (16/16). Obstruction symptoms did not relieve in one patient (6.25%) after stent placement, resulting in a clinical success rate of 93.75% (15/16). The endoscopic operation time for the 16 patients was 37.8±13.9 minutes. No bleeding, perforation, stent displacement, or detachment occurred after the operation. Fourteen patients underwent subsequent surgical treatment, the first-stage surgical resection anastomosis rate was 71.43% (10/14). This preliminary study suggests that the disposable subscope-assisted intestinal metal stent placement for the treatment of acute malignant colorectal obstruction is safe and effective, with no radiation exposure.
8.Optimization of drug management model for investigator-initiated trial with benchmarking analysis
Yufei XI ; Tianxiao WANG ; Xue ZHANG ; Yingzhuo DING ; Li YAN ; Feng JIANG ; Xiangui HE ; Jiannan HUANG ; Qin LI
China Pharmacy 2025;36(3):280-284
OBJECTIVE To optimize the management model of drugs used in investigator-initiated trial(IIT).METHODS With benchmarking analysis,based on the practical work experience of a tertiary specialized hospital in the field of IIT drug management in Shanghai,a thorough review was conducted,involving relevant laws,regulations,and academic literature to establish benchmark criteria and the evaluation standards.Starting from the initiation of IIT projects,a detailed comparative analysis of key processes was carried out,such as the receipt,storage,distribution,use and recycling of drugs for trial.The deficiencies in the current management of IIT drugs were reviewed in detail and a series of optimization suggestions were put forward.RESULTS It was found that the authorized records of drug management were missing,the training before project implementation was insufficient,and the records of receipt and acceptance of IIT drugs were incomplete.In light of these existing problems,improvement measures were put forward,including strengthening the training of drug administrators and stipulating that only drug administrators with pharmacist qualifications be eligible to inspect and accept drugs,etc.The related systems were improved,and 17 key points of quality control for the management of IIT drugs were developed.CONCLUSIONS A preliminary IIT drug management system for medical institutions has been established,which helps to improve the institutional framework of medical institutions in this field.
9.Human placental mesenchymal stem cells inhibit occurrence of pulmonary fibrosis by regulating transforming growth factor-beta 1/Smad3 signaling pathway
Jiawei CAO ; Shaorui DING ; Hua TIE ; Jing XUE ; Yuanyuan JIA ; Xueyun LIANG ; Feng LI
Chinese Journal of Tissue Engineering Research 2024;28(31):4970-4974
BACKGROUND:Human placental mesenchymal stem cells have been shown to be effective in inhibiting the development of pulmonary fibrosis,but the underlying mechanisms remain unclear. OBJECTIVE:To investigate the therapeutic effect and related mechanism of human placental mesenchymal stem cells on silica-induced pulmonary fibrosis in human embryonic lung fibroblasts(MRC-5). METHODS:CCK-8 assay was used to detect the effects of different mass concentrations of silica on the proliferation of MRC-5 at different time points.Immunofluorescence staining was used to screen out the best stimulating mass concentration and time of silica for subsequent experiments.MRC-5 cells were divided into blank group,silica group,and silica + human placental mesenchymal stem cell group.In the blank group,cells were not treated.In the silica group,MRC-5 cells were stimulated with 100 μg/mL silica for 48 hours.In the silica + human placental mesenchymal stem cell group,MRC-5 cells were stimulated with 100 μg/mL silica for 48 hours and then co-cultured with human placental mesenchymal stem cells for 24 hours.Immunofluorescence staining was used to detect the expression of α-smooth muscle actin and collagen type I in cells of each group.Western blot assay was used to detect the expressions of pulmonary fibrosis-related proteins and TGF-β1/Smad 3 signaling pathway-related proteins in cells of each group. RESULTS AND CONCLUSION:(1)CCK-8 assay results suggested that 100 μg/mL silica was the best mass concentration and time to stimulate MRC-5 cells for 48 hours.(2)Immunofluorescence staining results showed that the expression of α-smooth muscle actin and collagen type I in the silica + human placental mesenchymal stem cell group was significantly lower than that in the silica group.(3)Western blot assay results showed that compared with the silica group,the protein expression levels of α-smooth muscle actin,collagen type I,N-cadherin,fibronectin,transforming growth factor-β1,p-Smad3,and Smad3 in the silica + human placental mesenchymal stem cell group were decreased,and the expression of E-cadherin was increased.The difference was statistically significant(P<0.05).(4)The results showed that human placental mesenchymal stem cells had a significant therapeutic effect on silica-induced pulmonary fibrosis.Human placental mesenchymal stem cells can inhibit the development of pulmonary fibrosis by regulating transforming growth factor-β1/Smad3 signaling pathway.
10.Efficacy and safety of recombinant human anti-SARS-CoV-2 monoclonal antibody injection(F61 injection)in the treatment of patients with COVID-19 combined with renal damage:a randomized controlled exploratory clinical study
Ding-Hua CHEN ; Chao-Fan LI ; Yue NIU ; Li ZHANG ; Yong WANG ; Zhe FENG ; Han-Yu ZHU ; Jian-Hui ZHOU ; Zhe-Yi DONG ; Shu-Wei DUAN ; Hong WANG ; Meng-Jie HUANG ; Yuan-Da WANG ; Shuo-Yuan CONG ; Sai PAN ; Jing ZHOU ; Xue-Feng SUN ; Guang-Yan CAI ; Ping LI ; Xiang-Mei CHEN
Chinese Journal of Infection Control 2024;23(3):257-264
Objective To explore the efficacy and safety of recombinant human anti-severe acute respiratory syn-drome coronavirus 2(anti-SARS-CoV-2)monoclonal antibody injection(F61 injection)in the treatment of patients with coronavirus disease 2019(COVID-19)combined with renal damage.Methods Patients with COVID-19 and renal damage who visited the PLA General Hospital from January to February 2023 were selected.Subjects were randomly divided into two groups.Control group was treated with conventional anti-COVID-19 therapy,while trial group was treated with conventional anti-COVID-19 therapy combined with F61 injection.A 15-day follow-up was conducted after drug administration.Clinical symptoms,laboratory tests,electrocardiogram,and chest CT of pa-tients were performed to analyze the efficacy and safety of F61 injection.Results Twelve subjects(7 in trial group and 5 in control group)were included in study.Neither group had any clinical progression or death cases.The ave-rage time for negative conversion of nucleic acid of SARS-CoV-2 in control group and trial group were 3.2 days and 1.57 days(P=0.046),respectively.The scores of COVID-19 related target symptom in the trial group on the 3rd and 5th day after medication were both lower than those of the control group(both P<0.05).According to the clinical staging and World Health Organization 10-point graded disease progression scale,both groups of subjects improved but didn't show statistical differences(P>0.05).For safety,trial group didn't present any infusion-re-lated adverse event.Subjects in both groups demonstrated varying degrees of elevated blood glucose,elevated urine glucose,elevated urobilinogen,positive urine casts,and cardiac arrhythmia,but the differences were not statistica-lly significant(all P>0.05).Conclusion F61 injection has initially demonstrated safety and clinical benefit in trea-ting patients with COVID-19 combined with renal damage.As the domestically produced drug,it has good clinical accessibility and may provide more options for clinical practice.

Result Analysis
Print
Save
E-mail