1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.The Impairment Attention Capture by Topological Change in Children With Autism Spectrum Disorder
Hui-Lin XU ; Huan-Jun XI ; Tao DUAN ; Jing LI ; Dan-Dan LI ; Kai WANG ; Chun-Yan ZHU
Progress in Biochemistry and Biophysics 2025;52(1):223-232
ObjectiveAutism spectrum disorder (ASD) is a neurodevelopmental condition characterized by difficulties with communication and social interaction, restricted and repetitive behaviors. Previous studies have indicated that individuals with ASD exhibit early and lifelong attention deficits, which are closely related to the core symptoms of ASD. Basic visual attention processes may provide a critical foundation for their social communication and interaction abilities. Therefore, this study explores the behavior of children with ASD in capturing attention to changes in topological properties. MethodsOur study recruited twenty-seven ASD children diagnosed by professional clinicians according to DSM-5 and twenty-eight typically developing (TD) age-matched controls. In an attention capture task, we recorded the saccadic behaviors of children with ASD and TD in response to topological change (TC) and non-topological change (nTC) stimuli. Saccadic reaction time (SRT), visual search time (VS), and first fixation dwell time (FFDT) were used as indicators of attentional bias. Pearson correlation tests between the clinical assessment scales and attentional bias were conducted. ResultsThis study found that TD children had significantly faster SRT (P<0.05) and VS (P<0.05) for the TC stimuli compared to the nTC stimuli, while the children with ASD did not exhibit significant differences in either measure (P>0.05). Additionally, ASD children demonstrated significantly less attention towards the TC targets (measured by FFDT), in comparison to TD children (P<0.05). Furthermore, ASD children exhibited a significant negative linear correlation between their attentional bias (measured by VS) and their scores on the compulsive subscale (P<0.05). ConclusionThe results suggest that children with ASD have difficulty shifting their attention to objects with topological changes during change detection. This atypical attention may affect the child’s cognitive and behavioral development, thereby impacting their social communication and interaction. In sum, our findings indicate that difficulties in attentional capture by TC may be a key feature of ASD.
4.Related issues and responses in the process of industrialization of traditional knowledge of Chinese medicine
China Pharmacy 2025;36(2):140-145
OBJECTIVE To promote the industrialization process and modernization of traditional knowledge of Chinese medicine under the framework of the Regional Comprehensive Economic Partnership Agreement. METHODS It was done firstly, to sort out the framework for the protection of traditional knowledge in the international area; and secondly, to respond in the following two paths, one was the explicitization of traditional knowledge, and the other was the standardization of its carriers. RESULTS & CONCLUSIONS The goal of protecting traditional knowledge is to facilitate its modernization and accelerate its industrial utilization at the international level. As one of the countries of origin of traditional knowledge, our response is, to improve the registration provisions in the Regulations on the Protection of Traditional Knowledge of Chinese Medicine (Draft for Public Comments), promote the synchronization of both the patent and the standard application of Chinese medicine, and strengthen the integration of Chinese standardization system with the international one, which will promote the compliance application of traditional knowledge of Chinese medicine.
5.Related issues and responses in the process of industrialization of traditional knowledge of Chinese medicine
China Pharmacy 2025;36(2):140-145
OBJECTIVE To promote the industrialization process and modernization of traditional knowledge of Chinese medicine under the framework of the Regional Comprehensive Economic Partnership Agreement. METHODS It was done firstly, to sort out the framework for the protection of traditional knowledge in the international area; and secondly, to respond in the following two paths, one was the explicitization of traditional knowledge, and the other was the standardization of its carriers. RESULTS & CONCLUSIONS The goal of protecting traditional knowledge is to facilitate its modernization and accelerate its industrial utilization at the international level. As one of the countries of origin of traditional knowledge, our response is, to improve the registration provisions in the Regulations on the Protection of Traditional Knowledge of Chinese Medicine (Draft for Public Comments), promote the synchronization of both the patent and the standard application of Chinese medicine, and strengthen the integration of Chinese standardization system with the international one, which will promote the compliance application of traditional knowledge of Chinese medicine.
6.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
7.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
8.Preliminary study of the value of ultrasound parameters combined with cystatin C in monitoring early acute kidney injury after liver transplantation
Di ZHANG ; Jing SUN ; Kai ZHAO ; Chuanshen XU ; Shiwen DING ; Jinzhen CAI ; Jianhong WANG
Organ Transplantation 2025;16(4):574-581
Objective To explore the value of combined ultrasound parameters, including the hepatorenal index (HRI) and renal resistance index (RRI), with cystatin C (CysC) in monitoring early acute kidney injury (AKI) after liver transplantation. Methods Perioperative data from 121 liver transplant recipients who received organs from donation after brain death were collected. The HRI and RRI of the recipients were measured on postoperative days 1-7 and at 1 month, and the CysC levels were measured on postoperative day 1. The recipients were divided into the AKI group (n=53) and the non-AKI group (n=68) based on whether AKI occurred within 7 days after operation. The data of the two groups were compared, and the ultrasound parameters before and after recovery in the AKI group were analyzed. The value of combined HRI, RRI and CysC in monitoring AKI was also analyzed. Results AKI occurred in 53 recipients, with an incidence rate of 43.8%, including 30 cases of stage 1, 18 cases of stage 2, and 5 cases of stage 3. Among them, 49 cases occurred on postoperative day 1, and 4 cases occurred on postoperative day 2. Of these, 43 cases recovered within 7 days after surgery, 8 cases recovered within 2 months after surgery, 1 case was lost to follow-up, and 1 case received renal replacement therapy. The body mass index and preoperative CysC levels were higher in the AKI group than in the non-AKI group, and the operative time was longer in the AKI group than in the non-AKI group (all P < 0.05). The HRI on postoperative day 1 was lower in the AKI group than in the non-AKI group, while the RRI and CysC levels were higher (all P < 0.05). When AKI occurred, the HRI was lower than the baseline level, and the RRI was higher than the baseline level. As AKI recovered, the HRI gradually increased, and the RRI gradually decreased. The receiver operating characteristic curve analysis showed that the sensitivity and specificity of HRI ≤ 1.12 for predicting AKI were 0.623 and 0.878, respectively, with an area under the curve (AUC) of 0.801. The sensitivity and specificity of RRI ≥ 0.65 for predicting AKI were 0.878 and 0.676, respectively, with an AUC of 0.825. The sensitivity and specificity of CysC ≥ 1.38 mg/L for predicting AKI were 0.736 and 0.882, respectively, with an AUC of 0.851 (all P<0.01). The combination of HRI and CysC (AUC=0.897, P<0.01), RRI and CysC (AUC=0.910, P<0.01), and all three parameters combined (AUC=0.934, P<0.01) were more effective than using each parameter alone. Conclusions HRI and RRI may be used to monitor the occurrence and recovery of early AKI after liver transplantation. The combination of these two parameters with CysC has a high application value in monitoring early AKI after liver transplantation.
9.Adolescent Smoking Addiction Diagnosis Based on TI-GNN
Xu-Wen WANG ; Da-Hua YU ; Ting XUE ; Xiao-Jiao LI ; Zhen-Zhen MAI ; Fang DONG ; Yu-Xin MA ; Juan WANG ; Kai YUAN
Progress in Biochemistry and Biophysics 2025;52(9):2393-2405
ObjectiveTobacco-related diseases remain one of the leading preventable public health challenges worldwide and are among the primary causes of premature death. In recent years, accumulating evidence has supported the classification of nicotine addiction as a chronic brain disease, profoundly affecting both brain structure and function. Despite the urgency, effective diagnostic methods for smoking addiction remain lacking, posing significant challenges for early intervention and treatment. To address this issue and gain deeper insights into the neural mechanisms underlying nicotine dependence, this study proposes a novel graph neural network framework, termed TI-GNN. This model leverages functional magnetic resonance imaging (fMRI) data to identify complex and subtle abnormalities in brain connectivity patterns associated with smoking addiction. MethodsThe study utilizes fMRI data to construct functional connectivity matrices that represent interaction patterns among brain regions. These matrices are interpreted as graphs, where brain regions are nodes and the strength of functional connectivity between them serves as edges. The proposed TI-GNN model integrates a Transformer module to effectively capture global interactions across the entire brain network, enabling a comprehensive understanding of high-level connectivity patterns. Additionally, a spatial attention mechanism is employed to selectively focus on informative inter-regional connections while filtering out irrelevant or noisy features. This design enhances the model’s ability to learn meaningful neural representations crucial for classification tasks. A key innovation of TI-GNN lies in its built-in causal interpretation module, which aims to infer directional and potentially causal relationships among brain regions. This not only improves predictive performance but also enhances model interpretability—an essential attribute for clinical applications. The identification of causal links provides valuable insights into the neuropathological basis of addiction and contributes to the development of biologically plausible and trustworthy diagnostic tools. ResultsExperimental results demonstrate that the TI-GNN model achieves superior classification performance on the smoking addiction dataset, outperforming several state-of-the-art baseline models. Specifically, TI-GNN attains an accuracy of 0.91, an F1-score of 0.91, and a Matthews correlation coefficient (MCC) of 0.83, indicating strong robustness and reliability. Beyond performance metrics, TI-GNN identifies critical abnormal connectivity patterns in several brain regions implicated in addiction. Notably, it highlights dysregulations in the amygdala and the anterior cingulate cortex, consistent with prior clinical and neuroimaging findings. These regions are well known for their roles in emotional regulation, reward processing, and impulse control—functions that are frequently disrupted in nicotine dependence. ConclusionThe TI-GNN framework offers a powerful and interpretable tool for the objective diagnosis of smoking addiction. By integrating advanced graph learning techniques with causal inference capabilities, the model not only achieves high diagnostic accuracy but also elucidates the neurobiological underpinnings of addiction. The identification of specific abnormal brain networks and their causal interactions deepens our understanding of addiction pathophysiology and lays the groundwork for developing targeted intervention strategies and personalized treatment approaches in the future.
10.Analysis of red blood cell blood group gene polymorphism and applicability evaluation of PCR-TaqMan technology in the Hui ethnic blood donor population in Suzhou
Jia JIANG ; Zhihong FANG ; Zihao XU ; Kai WANG ; Nina JIANG
Chinese Journal of Blood Transfusion 2025;38(9):1218-1224
Objective: To investigate the characteristics of allele frequencies for 9 red blood cell (RBC) blood group systems in the Hui ethnic voluntary blood donor population of Suzhou using real-time fluorescence PCR technology, so as to provide technical support for establishing a RBC blood group genetic database. Methods: PCR-TaqMan technology was employed to perform genotyping detection for 9 RBC blood group systems using 144 samples from Hui voluntary blood donors in Suzhou, collected between October 2023 and August 2024. Results: Blood group allele frequencies among Suzhou Hui voluntary blood donors were distributed as follows: MNS system (M=0.566 0, N=0.434 0; S=0.079 9, s=0.920 1); Lutheran system (Lu
=0.003 5, Lu
=0.996 5; Au
=0.895 8, Au
=0.104 2); Kell system (K=0.000 0, k=1.000 0; Kp
=0.003 5, Kp
=0.996 5; JS
=0.000 0, JS
=1.000 0); Duffy system (Fy
=0.899 3, Fy
=0.100 7); Kidd system (JK
=0.451 4, JK
=0.548 6); Diego system (Di
=0.041 7, Di
=0.958 3); Yt system (Yt
=0.996 5, Yt
=0.003 5); Dombrock system (Do
=0.128 5, Do
=0.871 5); Colton system (Co
=1.000 0, Co
=0.000 0). The PCR-TaqMan-based RBC blood group genotyping technology successfully completed testing for all samples. Conclusion: The MNS, Lutheran, Duffy, Kidd, Diego, and Dombrock blood group systems in the Suzhou Hui population exhibited polymorphic distribution patterns, whereas the Colton system was monomorphic. Standardized application of PCR-TaqMan technology facilitates the establishment of an RBC blood group genetic database.

Result Analysis
Print
Save
E-mail