1.Cytotoxicity Studies of Light-oxygen-voltage (LOV) Domain Photosensitizers
Shuang XU ; Ben WAN ; Na SHA ; Kai-Hong ZHAO
Progress in Biochemistry and Biophysics 2025;52(2):487-500
ObjectiveAt present, the most commonly used photosensitizers in photodynamic therapy are still chemical photosensitizers, such as porphyrin and methylene blue, in order to specifically target cellular tissues, and thus poison cells, chemical photosensitizers need to use antibody conjugation or a transgenically encoded tag with affinity for the modified photosensitizing ligand, e.g. FlAsH, ReAsh or Halo Tag. Gene-encoded photosensitizers can directly poison cells by targeting specific cell compartments or organelles. However, currently developed gene-encoded photosensitizers have low reactive oxygen species production and low cytotoxicity, so it is necessary to continue to develop and obtain photosensitizers with higher reactive oxygen species production for the treatment of microbial infections and tumors. MethodsIn this study, we developed a photosensitizer LovPSO2 based on the light-oxygen-voltage (LOV) structural domain of phototropin-1B-like from Oryza sativa japonica. LovPSO2 was expressed in E. coli BL21(DE3) and purified to obtain protein samples, the purified protein samples were added 3 µmol/L singlet oxygen probe of SOSG and 5 µmol/L superoxide anion probe of DHE after fixed to A445=0.063±0.003, respectively, then measured every 2 min of singlet oxygen production for 10 min and every 1 min of superoxide anion production for 5 min under blue light irradiation at 445 nm, 70 µmol·m-2·s-1. ResultsThe results showed that LovPSO2 could produce a large amount of singlet oxygen under blue light irradiation at 445 nm, 70 µmol·m-2·s-1, and its singlet oxygen quantum yield was 0.61, but its superoxide anion yield was low, so in order to improve the superoxide anion yield of LovPSO2, a mutant with a relatively high superoxide anion yield was obtained by further development and design on its basis LovPRO2. The stability of proteins is crucial for research in drug development and drug delivery, among others. Temperature and light are the key factors affecting the production of reactive oxygen species (ROS) by photosensitive proteins and their stability, while the temperature in cell culture and mammals in vivo is about 37°C, and the temperature inside tumor cells is about 42-45°C. Therefore, we further analyzed the photostability of miniSOG, SOPP3, LovPSO2, and LovPRO2 and their thermostability at 37℃ and 45℃. The analysis of proteins thermostability showed that LovPSO2 and LovPRO2 had better thermostability at 37℃ and 45℃, respectively. Analysis of the photostability of the proteins showed that LovPRO2 had better photostability. In addition, to further determine the phototoxic effects of photosensitizers, LovPSO2 and LovPRO2 were expressed in E. coli BL21(DE3) and HeLa cells, respectively. The results showed that LovPSO2 and LovPRO2 had better phototoxicity to E. coli BL21(DE3) under blue light irradiation, and the cellular phototoxicity lethality was as high as 90% after 30 min of continuous light irradiation, but the phototoxicity was weaker in HeLa cells. The reason for this result may be that the intracellular environment exacerbated the photobleaching of FMN encapsulated by LovPSO2 and LovPRO2, respectively, which attenuated the damage of reactive oxygen species to animal cellular tissues, limiting its use as a mechanistic tool to study oxidative stress. ConclusionLovPSO2 and LovPRO2 can be used as antibacterial photosensitizers, which have broader application prospects in the food and medical fields.
2.Quality assessment of guidelines/consensuses on traditional Chinese medicine/integrated traditional Chinese and Western medicine diagnosis and treatment of nonalcoholic fatty liver disease
Ruimin JIAO ; Jingjie ZHAO ; Juanjuan LI ; Wei CHEN ; Chaoru HAN ; Li LI ; Chunjun XU ; Hong YOU
Journal of Clinical Hepatology 2025;41(3):446-452
ObjectiveTo evaluate the methodological quality and reporting quality of published guidelines/consensuses on traditional Chinese medicine (TCM)/integrated traditional Chinese and Western medicine diagnosis and treatment of nonalcoholic fatty liver disease (NAFLD), and to provide a basis for formulating guidelines/consensuses on TCM/integrated traditional Chinese and Western medicine diagnosis and treatment of NAFLD in the future. MethodsDatabases including PubMed, Embase, Web of Science, CNKI, Wanfang Data, and CBM and the websites of China Association of Chinese Medicine and China Association of Integrative Medicine were searched for related articles published up to September 1, 2024. Two clinical researchers independently assessed the methodological quality and reporting quality of the guidelines/consensuses on TCM/integrated traditional Chinese and Western medicine diagnosis and treatment of NAFLD by using Appraisal of Guidelines for Research and Evaluation Ⅱ (AGREE Ⅱ) and Reporting Items for Practice Guidelines in Healthcare (RIGHT). ResultsA total of nine guidelines/consensuses were included after literature screening, with four guidelines and five expert consensuses. The scores of different domains assessed by AGREE Ⅱ for the nine guidelines/consensuses were as follows: scope and purpose (47.1%), stakeholder involvement (41.0%), rigor of development (21.6%), clarity of presentation (40.2%), applicability (19.0%), and editorial independence (19.6%). The recommendation level of the articles was B level (recommended after revision) for four articles and C level (not recommended) for five articles. The RIGHT assessment showed high reporting rates for “Basic Information” and “Background”, while other areas needed to be improved. Currently, there was no international standard for the guidelines/consensuses on TCM/integrated traditional Chinese and Western medicine diagnosis and treatment of NAFLD, and the quality of these guidelines/consensuses needed to be enhanced to ensure comprehensiveness and credibility. ConclusionThere is still potential for improving the quality of guidelines/consensuses on TCM/integrated traditional Chinese and Western medicine diagnosis and treatment of NAFLD, and AGREE Ⅱ and RIGHT checklists should be strictly followed to ensure the fairness, scientific rigor, and transparency of these guidelines/consensuses.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Rapid characterization and identification of non-volatile components in Rhododendron tomentosum by UHPLC-Q-TOF-MS method.
Su-Ping XIAO ; Long-Mei LI ; Bin XIE ; Hong LIANG ; Qiong YIN ; Jian-Hui LI ; Jie DU ; Ji-Yong WANG ; Run-Huai ZHAO ; Yan-Qin XU ; Yun-Bo SUN ; Zong-Yuan LU ; Peng-Fei TU
China Journal of Chinese Materia Medica 2025;50(11):3054-3069
This study aimed to characterize and identify the non-volatile components in aqueous and ethanolic extracts of the stems and leaves of Rhododendron tomentosum by using sensitive and efficient ultra-performance liquid chromatography-quadrupole-time of flight mass spectrometry(UHPLC-Q-TOF-MS) combined with a self-built information database. By comparing with reference compounds, analyzing fragment ion information, searching relevant literature, and using a self-built information database, 118 compounds were identified from the aqueous and ethanolic extracts of R. tomentosum, including 35 flavonoid glycosides, 15 phenolic glycosides, 12 flavonoids, 7 phenolic acids, 7 phenylethanol glycosides, 6 tannins, 6 phospholipids, 5 coumarins, 5 monoterpene glycosides, 6 triterpenes, 3 fatty acids, and 11 other types of compounds. Among them, 102 compounds were reported in R. tomentosum for the first time, and 36 compounds were identified by comparing them with reference compounds. The chemical components in the ethanolic and aqueous extracts of R. tomentosum leaves and stems showed slight differences, with 84 common chemical components accounting for 71.2% of the total 118 compounds. This study systematically characterized and identified the non-volatile chemical components in the ethanolic and aqueous extracts of R. tomentosum for the first time. The findings provide a reference for active ingredient research, quality control, and product development of R. tomentosum.
Rhododendron/chemistry*
;
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Mass Spectrometry/methods*
;
Plant Leaves/chemistry*
6.Modified Sini Powder in treating mild to moderate generalized anxiety disorder in patients with syndrome of liver depression transforming into fire: a single-center, randomized, double-blind, dose-controlled trial.
Jia-Xin XU ; Hong-Jun YANG ; Hong-Wei WU ; Li-Jun MAO ; Jian-Xin WANG ; Zong-Liang YU ; Yang ZHAO ; Xiao-Nan HAO ; Rui GAO
China Journal of Chinese Materia Medica 2025;50(14):4063-4070
A single-center, randomized, double-blind, dose-controlled trial of modified Sini Powder in treating mild to moderate generalized anxiety disorder(GAD) in the patients with syndrome of liver depression transforming into fire was conducted at Xiyuan Hospital, China Academy of Chinese Medical Sciences. A total of 80 patients with mild to moderate GAD and the syndrome of liver depression transforming into fire were included. Patients were assigned by the central randomization system at a ratio of 3∶1 into an observation group(n=60, receiving a conventional-dose of granules of modified Sini Powder) and a control group(n=20, receiving low-dose granules with the active ingredients being 50% of that in observation group). Assessments were conducted before treatment(baseline), after 2 weeks of introduction, after 2/4/8 weeks of treatment, and after 4 weeks of follow-up. The results were summarized as follows. In terms of primary outcome indicators, the observation group(62.2%) showed higher total response rate than the control group(26.6%)(P<0.05), and greater Hamilton anxiety scale(HAMA) score reduction after 8 weeks of treatment(P<0.05). In terms of secondary outcome indicators, the HAMA score(somatic anxiety score), traditional Chinese medicine(TCM) syndrome scores, Pittsburgh sleep quality index(PSQI) scale, and clinical global impression(CGI) scale score in the observation group showed a significant compared to the control group at each visit points(P<0.05). Adverse events occurred in 10 cases, including 9(16.9%) cases in the observation group and 1(6.6%) case in the control group. No adverse reaction was observed. In conclusion, conventional-dose modified Sini Powder demonstrated superior efficacy and favorable safety for mild and moderate GAD in the patients with the syndrome of liver depression transforming into fire over low-dose treatment.
Humans
;
Male
;
Female
;
Adult
;
Middle Aged
;
Double-Blind Method
;
Drugs, Chinese Herbal/administration & dosage*
;
Anxiety Disorders/drug therapy*
;
Treatment Outcome
;
Young Adult
;
Powders
;
Aged
;
Liver/drug effects*
;
Generalized Anxiety Disorder
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Relationship Between Gastroesophageal Reflux Disease-Related Symptoms and Clinicopathologic Characteristics and Long-Term Survival of Patients with Esophageal Adenocarcinoma in China
Kan ZHONG ; Xin SONG ; Ran WANG ; Mengxia WEI ; Xueke ZHAO ; Lei MA ; Quanxiao XU ; Jianwei KU ; Lingling LEI ; Wenli HAN ; Ruihua XU ; Jin HUANG ; Zongmin FAN ; Xuena HAN ; Wei GUO ; Xianzeng WANG ; Fuqiang QIN ; Aili LI ; Hong LUO ; Bei LI ; Lidong WANG
Cancer Research on Prevention and Treatment 2025;52(8):661-665
Objective To investigatethe relationship between gastroesophageal reflux disease (GERD) symptoms and clinicopathological characteristics, p53 expression, and survival of Chinese patients with esophageal adenocarcinoma. Methods A total of

Result Analysis
Print
Save
E-mail