1.Value of fully autonomous ultrasonic robot in spleen imaging
Xuejuan WANG ; Yingying CHEN ; Xianghui CHEN ; Xuan ZHANG ; Xiuzhu MA ; Yun ZHANG ; Yutong MA ; Sufang LAI ; Nong GAO ; Haiyan KOU ; Shaohua ZHANG ; Faqin LYU
Chinese Journal of Ultrasonography 2025;34(5):426-430
Objective:To investigate the clinical value of a fully autonomous ultrasound robot in splenic ultrasound imaging.Methods:A retrospective study was conducted by enrolling 56 adult volunteers from the Third Medical Center of the Chinese PLA General Hospital between February 1-8,2024 as research subjects.A senior physician sequentially performed splenic ultrasound examinations using both the fully autonomous ultrasound robot and a matched portable ultrasound device. The acquired images were randomly coded and scored via a double-blind method by 3 physicians. The differences of the image quality scores and high-quality image proportions between the two groups were compared. Examination durations were recorded and compared between the two groups.Results:Both modalities successfully acquired splenic images in all 56 volunteers. No statistically significant differences were observed in image quality scores among the 3 physicians:(3.52 ± 1.31)points vs.(3.83 ± 1.23)points,(2.77 ± 1.23)points vs.(3.17 ± 1.17)points,and(3.48 ± 0.97)points vs.(3.79 ± 0.94)points(all P>0.05). The numbers of images scoring ≥ 3 points showed no significant differences:45(80.36%) vs. 50(89.29%),30(53.57%) vs. 38(67.86%),and 48(85.71%) vs. 52(92.86%)(all P>0.05). The fully autonomous ultrasound robot required significantly longer examination time[(60.86 ± 50.55)s vs.(7.95 ± 4.35)s, t=6.88, P<0.01]. Conclusions:The fully autonomous ultrasound robot demonstrates comparable image quality and clinically acceptable image proportions to conventional portable ultrasound in splenic examinations. These findings suggest its potential equivalence to operator-dependent ultrasound for splenic imaging,supporting its feasibility as an alternative ultrasound modality despite longer procedural duration.
2.Nursing care for midline catheter insertion in 12 patients with severe obesity
Xufen ZENG ; Xiuzhu CAO ; Hongying CHEN ; Shasha WU ; Xianghong JIN ; Linfang ZHAO
Chinese Journal of Nursing 2025;60(13):1563-1566
This study summarized the nursing experience of midline catheter insertion in 12 patients with a body mass index≥50,providing clinical references.Key nursing interventions included:pre-insertion patient positioning was adjusted to semi-Fowler's or sitting position based on respiratory status.The puncture sites were chosen at the middle or distal third of the upper arm with elbow flexion.The widened tourniquets and extended-length needles/catheter sheaths were used according to vascular depth and puncture angle.The modified pre-insertion length measurement and real-time ultrasound-guided vascular puncture were applied.The catheter with crisscross elastic bandage was secured post-insertion.All 12 patients successfully underwent catheterization,with devices removed after completing intravenous therapy and blood sampling.
3.Nursing care for midline catheter insertion in 12 patients with severe obesity
Xufen ZENG ; Xiuzhu CAO ; Hongying CHEN ; Shasha WU ; Xianghong JIN ; Linfang ZHAO
Chinese Journal of Nursing 2025;60(13):1563-1566
This study summarized the nursing experience of midline catheter insertion in 12 patients with a body mass index≥50,providing clinical references.Key nursing interventions included:pre-insertion patient positioning was adjusted to semi-Fowler's or sitting position based on respiratory status.The puncture sites were chosen at the middle or distal third of the upper arm with elbow flexion.The widened tourniquets and extended-length needles/catheter sheaths were used according to vascular depth and puncture angle.The modified pre-insertion length measurement and real-time ultrasound-guided vascular puncture were applied.The catheter with crisscross elastic bandage was secured post-insertion.All 12 patients successfully underwent catheterization,with devices removed after completing intravenous therapy and blood sampling.
4.Value of fully autonomous ultrasonic robot in spleen imaging
Xuejuan WANG ; Yingying CHEN ; Xianghui CHEN ; Xuan ZHANG ; Xiuzhu MA ; Yun ZHANG ; Yutong MA ; Sufang LAI ; Nong GAO ; Haiyan KOU ; Shaohua ZHANG ; Faqin LYU
Chinese Journal of Ultrasonography 2025;34(5):426-430
Objective:To investigate the clinical value of a fully autonomous ultrasound robot in splenic ultrasound imaging.Methods:A retrospective study was conducted by enrolling 56 adult volunteers from the Third Medical Center of the Chinese PLA General Hospital between February 1-8,2024 as research subjects.A senior physician sequentially performed splenic ultrasound examinations using both the fully autonomous ultrasound robot and a matched portable ultrasound device. The acquired images were randomly coded and scored via a double-blind method by 3 physicians. The differences of the image quality scores and high-quality image proportions between the two groups were compared. Examination durations were recorded and compared between the two groups.Results:Both modalities successfully acquired splenic images in all 56 volunteers. No statistically significant differences were observed in image quality scores among the 3 physicians:(3.52 ± 1.31)points vs.(3.83 ± 1.23)points,(2.77 ± 1.23)points vs.(3.17 ± 1.17)points,and(3.48 ± 0.97)points vs.(3.79 ± 0.94)points(all P>0.05). The numbers of images scoring ≥ 3 points showed no significant differences:45(80.36%) vs. 50(89.29%),30(53.57%) vs. 38(67.86%),and 48(85.71%) vs. 52(92.86%)(all P>0.05). The fully autonomous ultrasound robot required significantly longer examination time[(60.86 ± 50.55)s vs.(7.95 ± 4.35)s, t=6.88, P<0.01]. Conclusions:The fully autonomous ultrasound robot demonstrates comparable image quality and clinically acceptable image proportions to conventional portable ultrasound in splenic examinations. These findings suggest its potential equivalence to operator-dependent ultrasound for splenic imaging,supporting its feasibility as an alternative ultrasound modality despite longer procedural duration.
5.Biological Activities of Sesquiterpenoids: A Review
Liyuan YANG ; Ju CHENG ; Jianjun CHEN ; Xiaozheng CHEN ; Xiaoyi SHI ; Rasheed AMNA ; Wenjing SHI ; Xiuzhu LIU ; Xiaodong XIE
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(5):289-298
Sesquiterpenoids are natural compounds composed of 15 carbon atoms, which can be divided into sesquiterpene alcohols, ketones, lactones, aldehydes, and carboxylic acids according to oxygen groups. These compounds are widely distributed in nature, and their physiological activities are diverse. For example, many sesquiterpenes with potential anticancer effects have been found for anti-tumor effects, including cytotoxicity, antioxidant, immune regulation, cell proliferation, and so on. In addition, some sesquiterpenoids have good application prospects in antibacterial, anti-inflammatory, and anti-cardiovascular diseases. Malignant tumors, inflammation, bacterial diseases, and cardiovascular diseases are the main diseases that cause human death, and natural products have unique advantages in the treatment of these diseases. Therefore, the development of new drugs that are easy to promote has become a new research hotspot. In this paper, the sesquiterpenes extracted from the natural components of Chinese herbs and plants with anti-tumor, anti-inflammatory, antibacterial, and anti-cardiovascular activities, such as Xanthium, Atractylodes, Convolvulus, Acanthium, Ligularia, Artemisia, Ligularia, Ligularia, Labiaceae Mint, Acanthophyllum, Turmeria, Ginger, and other Chinese herbs and plants, were discussed. The biological activities and related mechanisms of this compound were reviewed, which provided a reference for further research and clinical application of sesquiterpenes.
6.Study on the application of different-length peripheral intravenous catheters in patients undergoing metabolic and bariatric surgery:a randomized clinical trial
Xiaohui YANG ; Chang LIU ; Weihua YU ; Jionghuang CHEN ; Wanting SHENG ; Xiuzhu CAO ; Xufen ZENG ; Xianghong JIN ; Linfang ZHAO
Chinese Journal of Nursing 2024;59(4):401-407
Objective To investigate the appropriate venous access for obese patients undergoing metabolic and bariatric surgery by comparing the clinical outcomes of different lengths of peripheral intravenous catheters.Methods Inpatients who underwent bariatric surgery in a tertiary hospital in Zhejiang from August 2022 to December 2022 were selected as the study population using a fixed-point continuous convenience sampling method.A stratified block randomisation method was used to divide the group into an experimental group 1(mini-midline catheters),an experimental group 2(midline catheters)and a control group(short peripheral intravenous catheters,Short PIVCs).The incidence of catheter-related complications,the rate of extubation due to complications,the duration of catheter retention,the time to first catheter-related complication were compared in the 3 groups.Results A total of 186 patients were included,with 62 patients in each group.The overall incidence of catheter-related complications in experimental group 1,experimental group 2,and control group were 25.81%,8.06%,and 58.06%.The extubation rates due to complications were 19.35%,4.84%,and 41.94%,and the duration of catheter retention was 7.00(6.00,7.00)d,7.00(6.00,7.00)d,6.00(3.00,6.25)d.The differences were statistically different(P<0.05)when comparing the 3 groups.Among them,the differences in the overall incidence of catheter-related complications and the rate of extubation due to complications were statistically significant when comparing experimental group 1 with the control group,experimental group 2 with the control group,and experimental group 1 with experimental group 2(P<0.017);the duration of catheter retention in both experimental group 1 and experimental group 2 were higher than it in the control group,and the differences were statistically different(P<0.017).Conclusion The complication rate of mini-midline catheters and midline catheters is lower than that of short ones,and the indwelling time is consistent with the perioperative period of metabolic and bariatric surgery,which is suitable for use in patients undergoing metabolic and bariatric surgery.
7.Value of conventional ultrasonography combined with cervical compression in the diagnosis of orbital venous malformation
Xiaochu DANG ; Rui MA ; Yueyue LI ; Yingying CHEN ; Yutong MA ; Yun ZHANG ; Xuan ZHANG ; Xuejuan WANG ; Yuqian MIAO ; Xiuzhu MA ; Xinji YANG ; Faqin LYU
Chinese Journal of Ultrasonography 2023;32(5):444-448
Objective:To explore the value of conventional ultrasonography combined with cervical compression in the diagnosis of orbital venous malformation (OVM).Methods:A total of 43 patients with suspected OVM were admitted in sequentially from January 2019 to July 2022 in the Third Medical Center of PLA General Hospital. All patients were examined by ultrasonography combined with cervical compression and demonstrated by operation or digital subtraction angiography (DSA). The conventional ultrasound features of OVM were summarized, and the value of conventional ultrasonography combined with cervical compression in the diagnosis of OVM was discussed.Results:The features of the conventional ultrasound combined with cervical compression for diagnosis of OVM were as follows: the interior of lesion was mainly tubular structure, and the compression test was positive. After cervical compression, the lesion enlarged and the inner diameter of the internal tubular structure widened. Doppler flow imaging showed that the interior of lesion was mainly venous blood flow. Compared with the results of postoperative pathology or DSA, the sensitivity, specificity, accuracy and positive predictive value of ultrasonography combined with cervical compression were 0.952, 1.000, 95.3% and 100%, respectively. The results of Fisher exact diagnosis showed that there was no significant difference between ultrasonography and operation or DSA of OVM( P>0.05). Conclusions:Conventional ultrasound combined with cervical compression can be used as an effective method for the diagnosis of OVM.
8.Ultrasound combined with Ki-67 for predicting pathological complete response of triple-negative breast cancer after neoadjuvant chemotherapy
Na LI ; Yu QIAN ; Xiuzhu QI ; Yajing LIU ; Zhaoting SHI ; Yi GAO ; Cai CHANG ; Yaling CHEN
Chinese Journal of Ultrasonography 2023;32(12):1070-1075
Objective:To investigate the value of ultrasound and Ki-67 for early predicting pathological complete response (pCR) of triple negative breast cancer(TNBC) after neoadjuvant chemotherapy (NAC).Methods:Retrospective analysis was performed in 190 patients with TNBC who underwent surgery after NAC treatment at the Cancer Hospital of Fudan University from January 2019 to December 2022. All patients underwent ultrasound examination before and after 2 and 4 cycles of NAC treatment. According to the operation pathological results after NAC, the patients were divided into pCR group and non-pCR group. The differences in ultrasound and Ki-67 parameters were compared between the pCR and non-pCR groups, and binary Logistic regression analysis was performed to determine the independent predictors for pCR. The ROC curve was plotted to evaluate the diagnostic efficacy.Results:Tumor maximum diameter, relative change rates of tumor maximum diameter after 2-cycle and 4-cycle NAC (ΔD2, ΔD4), relative change rate of lymph node short diameter after 2-cycle NAC (ΔS2), T-stage, N-stage and Ki-67 showed statistically significant differences between the pCR group and the non-pCR group (all P<0.05). Logistic regression analysis showed that ΔD4, T-stage, N-stage and Ki-67 were independent predictors for pCR ( OR=1.029, P=0.011; OR=0.300, P=0.009; OR=0.653, P=0.048; OR=1.028, P=0.001). The area under the curve (AUC) of pCR was 0.804 (95% CI=0.742-0.866), the sensitivity and specificity were 67.5% and 83.2% respectively. Conclusions:The combination parameters of ΔD4, T-stage, N-stage and Ki-67 have certain clinical value for predicting pCR of TNBC.
9.Value of 5G remote ultrasonic robot in diagnosing high altitude pulmonary edema
Yun ZHANG ; Yingying CHEN ; Yutong MA ; Renqing Can JIAN ; Xuan ZHANG ; Xiaochu DANG ; Xuejuan WANG ; Yuqian MIAO ; Xiuzhu MA ; Luobu Zeng DAN ; Caishun SHI ; Li WU ; Cong TU ; Faqin LYU
Chinese Journal of Ultrasonography 2022;31(11):921-926
Objective:To explore the value of 5G robotic remote ultrasound in the diagnosis of plateau pulmonary edema(HAPE).Methods:A total of 27 patients who quickly entered Nagqu, Tibet at an altitude of 4 600 m-5 600 m from March to December 2021 and developed one of the clinical symptoms of HAPE were collected. All patients were examined by 5G remote robotic ultrasound and lung CT respectively. Kappa test was used to analyze the consistency of the two diagnostic results, and McNemar test was used to compare the difference in diagnostic results. The ROC curve was used to analyze the sensitivity and specificity of remote lung ultrasound scores in the diagnosis of HAPE.Results:Among the 27 patients, 16 showed thickening of pleural line, increasing of B line, lung consolidation, pleural effusion, etc. Meanwhile, 11 showed no abnormality. Additionally, 8 cases had diffuse pulmonary fluid in both lungs, and 8 cases had localized pulmonary fluid. ROC curve showed that the area under the curve of lung ultrasound score for the diagnosis of HAPE was 0.947 (95% CI=0.78-0.99, P<0.001). The sensitivity and specificity were 0.933 and 0.917, respectively. Lung CT diagnosis was positive in 15 cases. Lung CT showed thickening of lung texture, ground glass, small nodular shadow, fine reticulate shadow, etc. The diagnostic results of the two techniques were in good agreement (Kappa=0.924, P<0.001), and there was no significant difference between the two methods ( P>0.05). Conclusions:5G remote robotic ultrasound has high consistency with CT in the diagnosis of HAPE and is an alternative early diagnosis method for HAPE. It may have clinical application value in scattered medical resources and remote plateau areas.
10.Recent advance in depression after traumatic brain injury
Xiuzhu SU ; Fei YANG ; Huanghui WU ; Guozhong CHEN
Chinese Journal of Neuromedicine 2022;21(7):721-726
Traumatic brain injury (TBI) is characterized by high incidence, high disability rate, and many sequelae. Depression after TBI is the most common sequelae of mental illness, which can affect the prognosis and quality of life of patients. The specific pathogenesis of post-TBI depression is not yet known, and there is no recognized prevention and treatment plan. This review aims to retrospectively summarize the epidemiology, risk factors, clinical manifestations, evaluation, possible mechanisms, and discoveries of treatment of post-TBI depression in the past 5 years, which will help clinicians manage this difficult disease more effectively and provide a reference for future research.

Result Analysis
Print
Save
E-mail