1.Free inferior gluteal perforator flap for immediate breast reconstruction: a case report and literature review
Lan MU ; Junbo PAN ; Guisheng HE ; Xiuxiu CHEN ; Tao SONG ; Haohao JIAN ; Zuolei YANG ; Sisi WANG ; Huangfu WU ; Yazhen ZHANG ; Kun XIE ; Chuanwei SUN ; Wentian XU ; Guanghua FU ; Junzhang CHEN ; Bo LI ; Hengyu CHEN ; Yilian XU ; Mingmei HE ; Jinhui HUANG ; Peng LI
Chinese Journal of Microsurgery 2025;48(2):161-166
Objective:To explore the possibility of using a inferior gluteal artery perforator flap (IGAPF) for breast reconstruction in the patient who did not have suitable donor site in back and abdomen.Methods:In November 2024, a 25-year-old unmarried and childless woman with right breast cancer received immediate right breast reconstruction by a right free IGAPF after modified right mastectomy in the Department of Breast and Thyroid Surgery, Second Affiliated Hospital of Hainan Medical University. The locations of perforators were confirmed by both Multi-detector computed tomography angiography (MDCTA) and portable Doppler blood flow detector before surgery. The IGAPF was designed to take the inferior gluteal wrinkle as the lower edge, the axis of the flap was parallel to the inferior gluteal wrinkle, and the width of the flap was estimated where the incision could be directly closed. The size of right IGAPF was 6.0 cm×19.0 cm. Sharp dissection was performed between the sarcolemma and muscle fibres of gluteus, then the perforators were dissected along the direction of muscle fibres of gluteus. The vascular pedicle was kept at about 8.0 cm in length. The diameter of artery was about 2.0 mm and that for the veins was about 1.5 mm. End-to-end anastomoses with the right thoracodorsal artery and vein were successfully carried out. The donor site was directly closed, and it was hidden in the inferior gluteal wrinkle. Postoperative outpatient clinical review was made.Results:Pathological examination reported: an invasive carcinoma of right breast, axillary lymph node metastasis (2/10). The patient recovered well and the flap survived without any complication, i.e. ischemic necrosis, infection and haematoma. The patient was off-bed at 3 days and discharged at 13 days after surgery. At the 40 days of postoperative follow-up, the patient achieved a good recovery and the lower limb activity was not affected by the surgery. The patient was satisfied with the reconstructed breast and donor site recovery. The patient followed with scheduled chemotherapy and subsequent radiotherapy. The volume of reconstructed breast was smaller than the other breast, of which the patient was fully informed before the surgery.Conclusion:A free IGAPF provides an alternative donor sites for achieving a breast reconstruction due to the reliable pedicle vessels and invisible donor scars.
2.The effect of intervertebral differential dynamic system combined with the spinal assessment training sys-tem on the pain and function in patients with lumbar disc herniation
Chen FAN ; Xiuxiu SHI ; Ying XU
Chinese Journal of Rehabilitation Medicine 2025;40(9):1344-1350
Objective:To investigate the clinical efficacy of Intervertebral Differential Dynamics(IDD)combined with spinal assessment training system on the patients with lumbar disc herniation.Method:Sixty patients with L4—L5 or L5—S1 paramedian Lumbar Disc Herniation(LDH)were selected and randomly divided into a test group and a control group with 30 patients in each group through the random number table method.Both groups received health education.The control group was given IDD therapy once a day,5 times a week for a total of 4 weeks.The test group was given additional spinal assessment training sys-tem training on the basis of the control group;Spinal assessment training system training was conducted 3 times a week for a total of 4 weeks,12 units.The visual analog scale(VAS)was used to evaluate the severity of low back pain and leg pain.The ODI(Oswestry Disability Index)and the Japanese Orthopaedic Association(JOA)Low Back Pain Rating Scale were used to evaluate the lumbar dysfunction.Spinal assessment training system was used to measure the maximum angle and maximum muscle strength of lumbar flexion and dorsi-flexion.At the same time,the cross-sectional area of the lumbar multifidus muscle was measured by a color Doppler ultrasound diagnostic system before and after treatment.Result:Before treatment,there were no significant differences between the two groups in terms of VAS scores for low back pain and leg pain,ODI scores,JOA scores,maximum lumbar flexion and dorsiflexion,maximum muscle strength values,and cross-sectional area of multifidus muscle(P>0.05).After treatment,VAS scores for low back pain and leg pain,ODI,JOA,lumbar flexion and dorsiflexion range of motion,as well as the maximum muscle strength values for flexion and extension in the experimental group were better than those before treatment,and all indicators in the experimental group were better than those in the control group,with significant differences(P<0.05).Conclusion:IDD combined with spinal assessment training system can effectively relieve back and leg pain in patients with L4—L5 or L5—S1 paracenteral lumbar disc herniation,improve the degree of physical activity limitation,increase lumbar motion and muscle strength,and improve lumbar function.
3.The role of information management system in the management of investigator initiated trials ethics re-view
Modern Hospital 2025;25(8):1239-1241,1245
Objective To explore how to enhance the quality and efficiency of ethics committee operations based on an information management system.Methods This study analyzes the challenges in the ethical review of Investigator Initiated Trials(IIT)and compares existing ethics review systems in China.Using a tertiary hospital as an example,the paper details the practi-cal impact of an information management system for improving the management level of the ethics committee office and the effi-ciency of project reviews.Results The ethics review information management system evolved from basic usage and initial ethics review functions to include ethics tracking review and meeting review capabilities,offering comprehensive functionality.Conclu-sion The information management system enhances the efficiency of ethical review processes,but ongoing optimization is neces-sary to better align with the needs of clinical research in medical institutions.
4.Ratio of right ventricular free wall longitudinal strain to pulmonary artery systolic pressure for evaluating right ventricular systolic function in patients with hypertrophic cardiomyopathy
Ranran LIU ; Xiaofei CHEN ; Guozhang TANG ; Xiao MA ; Jianan JIANG ; Xiuxiu FU
Chinese Journal of Interventional Imaging and Therapy 2025;22(2):97-101
Objective To observe the value of right ventricular free wall longitudinal strain(RVFWLS)to pulmonary artery systolic pressure(PASP)ratio(RVFWLS/PASP)for evaluating systolic function of right ventricle(RV)in patients with hypertrophic cardiomyopathy(HCM).Methods Fifty-two HCM patients were retrospectively collected and divided into group A(RVFWLS/PASP≤0.75,n=26)and B(RVFWLS/PASP>0.75,n=26)according to median RVFWLS/PASP.Meanwhile,26 healthy individuals were included as control group.Parameters of echocardiography and speckle tracking imaging(STI)were obtained and compared among 3 groups.The correlations of RVFWLS/PASP and other parameters were analyzed with linear regression.Results In group A and B,left ventricular ejection fraction(LVEF),RV septal longitudinal strain(RVSepLS),RVFWLS,RV end-diastolic volume index(RVEDVi),RV stroke volume(RVSV),RV fractional area change(RVFAC)and left ventricular global longitudinal strain(LVGLS)were all lower,while the ratio of peak E blood flow velocity at mitral orifice diastole to early mitral intervalal annulus diastole velocity(E/e′)were higher than those in control group(all adjusted P<0.05).Compared with group B and control group,group A had higher PASP but lower RV ejection fraction(RVEF)(all adjusted P<0.05).Furthermore,RVFWLS and LVGLS were both lower in group A than in group B(both adjusted P<0.05).Linear regression analysis showed that RVSepLS and RVEF were independently linearly related to RVFWLS/PASP(both P<0.05).Conclusion RVFWLS/PASP could be used to monitor changes of RV systoic function in HCM patients at early stage.
5.A detection method of arsenic free fully automatic online digestion iodine analyzer for urinary iodine
Xiuxiu SUN ; Ji'an XIE ; Shudong XU ; Jian JIANG ; Ying WEI ; Ruihan ZONG ; Ningning CHEN ; Hui LIU
Chinese Journal of Endemiology 2025;44(11):920-924
Objective:To establish an arsenic free fully automatic online digestion iodine analyzer detection method for urinary iodine (hereinafter referred to as the method).Methods:Based on the principle of iodine catalyzed antimony cerium redox reaction, a fully automatic online digestion iodine analyzer was used to determine the iodine content in urine. The effectiveness of the method in terms of detection limit, precision, accuracy (determination of urinary iodine primary standard reference materials GBW09108z and GBW09110f and spiked recovery experiment), and interference experiments was validated. The method was compared with the arsenic cerium catalytic spectrophotometry method recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:The linear range of the method was 0 - 300 μg/L, with a correlation coefficient │ r│> 0.999 5. The qualitative and quantitative detection limits were 7.41 and 18.01 μg/L, respectively. The relative standard deviation ( RSD) of urine samples with different iodine concentrations ranged from 1.0% to 1.7%. The results of the determination of iodine concentrations in urine using standard substances GBW09108z and GBW09110f were within the given standard range, with RSD < 2.5%. The range of spiked recovery rates for urine samples with different iodine concentrations was 101.3% to 104.8%, with an overall average spiked recovery rate of 103.0%. The average concentration of the baseline iodine standard solution was determined to be 116.21 μg/L, and the relative error of the concentration determination with the addition of interfering substances was less than 5.0%. The comparison results showed that there was no statistically significant difference in the measurement results between the two methods ( t = - 0.06, P = 0.952). Conclusions:The method adopts automated detection, which is simple to operate, labor-saving, and does not require the use of arsenic trioxide. It has high precision and accuracy, and is suitable for detection of large quantities of samples.
6.The application value of paediatric age-adjusted shock index in children with sepsis and septic shock
Wei LI ; Haiyan GE ; Shuang LIU ; Siyuan HUANG ; Jing CHEN ; Ning LI ; Xiuxiu LU ; Dong QU
Chinese Pediatric Emergency Medicine 2025;32(7):500-503
Objective:To explore the value of paediatric age-adjusted shock index(SIPA)in early identification of septic shock in children,and to evaluate the relationship between SIPA and disease severity and prognosis.Methods:The infected children admitted to the department of critical care medicine of the Children's Hospital Affiliated to Capital Institute of Pediatrics from May 2023 to July 2024 were collected. Dynamic assessment was performed 0 to 6 hours after admission. Patients diagnosed with sepsis without septic shock were classified as the sepsis group and those diagnosed with sepsis with septic shock were classified as the septic shock group. According to whether the blood pressure of the children decreased,they were divided into two groups:compensated septic shock group and decompensated septic shock group. The difference of SIPA among the three groups was analyzed,and the predictive value of SIPA on case fatality rate,lactate level,pediatric critical illness score,ventilator utilization rate and length of hospital stay were analyzed.Results:Among 203 children with sepsis,112 were males and 91 were females. There were 146 cases in the sepsis group,37 cases in the compensated septic shock group and 20 cases in the decompensated septic shock group. There was no significant difference between the three groups in gender( P>0.05),but there was a statistically significant difference in age( χ 2=32.905, P<0.001). There was no significant difference in age between the sepsis group and the compensated septic shock group( P>0.05). The age of sepsis group and decompensated septic shock group,compensated septic shock group and decompensated septic shock group were statistically significant( χ 2=29.431, P<0.001; χ 2=19.764, P=0.001). The proportion of increased SIPA was statistically different among the three groups,with both the compensated septic shock group and the decompensated septic shock group being higher than the sepsis group( χ2=20.383, P<0.001; χ2=33.600, P<0.001). The decompensated septic shock group was higher than the compensated septic shock group( χ2=6.555, P=0.01). SIPA was correlated with case fatality rate,lactate level,pediatric critical illness score,ventilator use rate and length of stay of the children,with statistically significant differences( P<0.05). Conclusion:The increase of SIPA can be used for the early identification of septic shock in children,and it has a certain early warning value for the prognosis assessment of sepsis and septic shock.
7.The effect of intervertebral differential dynamic system combined with the spinal assessment training sys-tem on the pain and function in patients with lumbar disc herniation
Chen FAN ; Xiuxiu SHI ; Ying XU
Chinese Journal of Rehabilitation Medicine 2025;40(9):1344-1350
Objective:To investigate the clinical efficacy of Intervertebral Differential Dynamics(IDD)combined with spinal assessment training system on the patients with lumbar disc herniation.Method:Sixty patients with L4—L5 or L5—S1 paramedian Lumbar Disc Herniation(LDH)were selected and randomly divided into a test group and a control group with 30 patients in each group through the random number table method.Both groups received health education.The control group was given IDD therapy once a day,5 times a week for a total of 4 weeks.The test group was given additional spinal assessment training sys-tem training on the basis of the control group;Spinal assessment training system training was conducted 3 times a week for a total of 4 weeks,12 units.The visual analog scale(VAS)was used to evaluate the severity of low back pain and leg pain.The ODI(Oswestry Disability Index)and the Japanese Orthopaedic Association(JOA)Low Back Pain Rating Scale were used to evaluate the lumbar dysfunction.Spinal assessment training system was used to measure the maximum angle and maximum muscle strength of lumbar flexion and dorsi-flexion.At the same time,the cross-sectional area of the lumbar multifidus muscle was measured by a color Doppler ultrasound diagnostic system before and after treatment.Result:Before treatment,there were no significant differences between the two groups in terms of VAS scores for low back pain and leg pain,ODI scores,JOA scores,maximum lumbar flexion and dorsiflexion,maximum muscle strength values,and cross-sectional area of multifidus muscle(P>0.05).After treatment,VAS scores for low back pain and leg pain,ODI,JOA,lumbar flexion and dorsiflexion range of motion,as well as the maximum muscle strength values for flexion and extension in the experimental group were better than those before treatment,and all indicators in the experimental group were better than those in the control group,with significant differences(P<0.05).Conclusion:IDD combined with spinal assessment training system can effectively relieve back and leg pain in patients with L4—L5 or L5—S1 paracenteral lumbar disc herniation,improve the degree of physical activity limitation,increase lumbar motion and muscle strength,and improve lumbar function.
8.The role of information management system in the management of investigator initiated trials ethics re-view
Modern Hospital 2025;25(8):1239-1241,1245
Objective To explore how to enhance the quality and efficiency of ethics committee operations based on an information management system.Methods This study analyzes the challenges in the ethical review of Investigator Initiated Trials(IIT)and compares existing ethics review systems in China.Using a tertiary hospital as an example,the paper details the practi-cal impact of an information management system for improving the management level of the ethics committee office and the effi-ciency of project reviews.Results The ethics review information management system evolved from basic usage and initial ethics review functions to include ethics tracking review and meeting review capabilities,offering comprehensive functionality.Conclu-sion The information management system enhances the efficiency of ethical review processes,but ongoing optimization is neces-sary to better align with the needs of clinical research in medical institutions.
9.A detection method of arsenic free fully automatic online digestion iodine analyzer for urinary iodine
Xiuxiu SUN ; Ji'an XIE ; Shudong XU ; Jian JIANG ; Ying WEI ; Ruihan ZONG ; Ningning CHEN ; Hui LIU
Chinese Journal of Endemiology 2025;44(11):920-924
Objective:To establish an arsenic free fully automatic online digestion iodine analyzer detection method for urinary iodine (hereinafter referred to as the method).Methods:Based on the principle of iodine catalyzed antimony cerium redox reaction, a fully automatic online digestion iodine analyzer was used to determine the iodine content in urine. The effectiveness of the method in terms of detection limit, precision, accuracy (determination of urinary iodine primary standard reference materials GBW09108z and GBW09110f and spiked recovery experiment), and interference experiments was validated. The method was compared with the arsenic cerium catalytic spectrophotometry method recommended by the National Reference Laboratory for Iodine Deficiency Disorders.Results:The linear range of the method was 0 - 300 μg/L, with a correlation coefficient │ r│> 0.999 5. The qualitative and quantitative detection limits were 7.41 and 18.01 μg/L, respectively. The relative standard deviation ( RSD) of urine samples with different iodine concentrations ranged from 1.0% to 1.7%. The results of the determination of iodine concentrations in urine using standard substances GBW09108z and GBW09110f were within the given standard range, with RSD < 2.5%. The range of spiked recovery rates for urine samples with different iodine concentrations was 101.3% to 104.8%, with an overall average spiked recovery rate of 103.0%. The average concentration of the baseline iodine standard solution was determined to be 116.21 μg/L, and the relative error of the concentration determination with the addition of interfering substances was less than 5.0%. The comparison results showed that there was no statistically significant difference in the measurement results between the two methods ( t = - 0.06, P = 0.952). Conclusions:The method adopts automated detection, which is simple to operate, labor-saving, and does not require the use of arsenic trioxide. It has high precision and accuracy, and is suitable for detection of large quantities of samples.
10.The application value of paediatric age-adjusted shock index in children with sepsis and septic shock
Wei LI ; Haiyan GE ; Shuang LIU ; Siyuan HUANG ; Jing CHEN ; Ning LI ; Xiuxiu LU ; Dong QU
Chinese Pediatric Emergency Medicine 2025;32(7):500-503
Objective:To explore the value of paediatric age-adjusted shock index(SIPA)in early identification of septic shock in children,and to evaluate the relationship between SIPA and disease severity and prognosis.Methods:The infected children admitted to the department of critical care medicine of the Children's Hospital Affiliated to Capital Institute of Pediatrics from May 2023 to July 2024 were collected. Dynamic assessment was performed 0 to 6 hours after admission. Patients diagnosed with sepsis without septic shock were classified as the sepsis group and those diagnosed with sepsis with septic shock were classified as the septic shock group. According to whether the blood pressure of the children decreased,they were divided into two groups:compensated septic shock group and decompensated septic shock group. The difference of SIPA among the three groups was analyzed,and the predictive value of SIPA on case fatality rate,lactate level,pediatric critical illness score,ventilator utilization rate and length of hospital stay were analyzed.Results:Among 203 children with sepsis,112 were males and 91 were females. There were 146 cases in the sepsis group,37 cases in the compensated septic shock group and 20 cases in the decompensated septic shock group. There was no significant difference between the three groups in gender( P>0.05),but there was a statistically significant difference in age( χ 2=32.905, P<0.001). There was no significant difference in age between the sepsis group and the compensated septic shock group( P>0.05). The age of sepsis group and decompensated septic shock group,compensated septic shock group and decompensated septic shock group were statistically significant( χ 2=29.431, P<0.001; χ 2=19.764, P=0.001). The proportion of increased SIPA was statistically different among the three groups,with both the compensated septic shock group and the decompensated septic shock group being higher than the sepsis group( χ2=20.383, P<0.001; χ2=33.600, P<0.001). The decompensated septic shock group was higher than the compensated septic shock group( χ2=6.555, P=0.01). SIPA was correlated with case fatality rate,lactate level,pediatric critical illness score,ventilator use rate and length of stay of the children,with statistically significant differences( P<0.05). Conclusion:The increase of SIPA can be used for the early identification of septic shock in children,and it has a certain early warning value for the prognosis assessment of sepsis and septic shock.

Result Analysis
Print
Save
E-mail