1.Shaoyaotang Ameliorates Ulcerative Colitis by Regulating miR-155-5p
Ruoru HUANG ; Bo ZOU ; Yu ZHANG ; Yiqian YU ; Qi CHENG ; Youwei XIAO ; Jiachun XIONG ; Yan GONG ; Dongshen WU ; Hui CAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):61-68
ObjectiveTo investigate the role of microRNA-155-5p (miR-155-5p) in ulcerative colitis (UC) and study the molecular mechanism of Shaoyaotang in the treatment of UC by regulating miR-155-5p. MethodsForty-eight SPF-grade male C57BL/6 mice were selected and assigned via the random number table method into 6 groups (n=8): A blank control group, a model group, a mesalazine (0.39 g·kg-1) group, a Shaoyaotang (31.08 g·kg-1) group, a Janus kinase 1 (JAK1) inhibitor (baricitinib, 10 mg·kg-1) group, and a Shaoyaotang combined with inhibitor (baricitinib 10 mg·kg-1 + Shaoyaotang 31.08 g·kg-1) group. After successful modeling of UC by gavage of 3% dextran sulphate sodium solution, each group received corresponding drug intervention for 7 days. Shaoyaotang and mesalazine were administered by gavage, and baricitinib by intraperitoneal injection. Twenty-four hours after the last administration, mice were anesthetized by intraperitoneal injection of pentobarbital sodium, and blood was collected for determination of white blood cell count and erythrocyte sedimentation rate (ESR). Mice were then sacrificed for measurement of colon length. Hematoxylin-eosin staining was used to observe colonic pathological changes and perform pathological scoring. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was employed to determine the relative expression of miR-155-5p in the colonic tissue, and Western blot was used to determine the protein levels of JAK1, phosphorylated JAK1 (p-JAK1), suppressor of cytokine signaling 1 (SOCS1), signal transducer and activator of transcription 1 (STAT1), and phosphorylated STAT1 (p-STAT1). ResultsCompared with the blank control group, the model group showed increased disease activity index (DAI) score and pathological score, shortened colon, upregulated relative expression of miR-155-5p and protein levels of p-JAK1 and p-STAT1, downregulated protein level of SOCS1 in the colonic tissue, prolonged time of erythrocyte sedimentation, and increased white blood cell count (P<0.01). Compared with the model group, all drug-treated groups exhibited improvements in the above indicators (P<0.01). Moreover, the Shaoyaotang group showed better therapeutic effects than the mesalazine group in regulating miR-155-5p expression, related protein levels, DAI score, and colonic pathological score (P<0.01). ConclusionShaoyaotang may downregulate miR-155-5p to relieve its inhibition on SOCS1, thereby suppressing the excessive activation of the JAK1/STAT1 signaling pathway and ultimately alleviating intestinal inflammatory damage.
2.Shaoyaotang Regulates TLR4/MyD88/NF-κB Signaling Pathway to Protect Intestinal Mucosal Barrier in Ulcerative Colitis
Dongsheng WU ; Yu ZHANG ; Wenjing QUAN ; Wanqing XIONG ; Bo ZOU ; Youwei XIAO ; Ruoru HUANG ; Yan GONG ; Hui CAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):69-75
ObjectiveTo investigate the role of the Toll-like receptor 4 (TLR4)/myeloid differentiation factor 88 (MyD88)/nuclear factor-κB (NF-κB) signaling pathway in intestinal mucosal barrier damage in ulcerative colitis, as well as the intervention mechanism of Shaoyaotang. MethodsSixty SD rats were allocated into a blank group, a model group, a mesalazine (0.42 g·kg-1) group, and low-, medium-, and high-dose (11.1, 22.2, 44.4 g·kg-1, respectively) Shaoyaotang groups. A model of ulcerative colitis was induced by 2,4,6-trinitrobenzenesulfonic acid (TNBS). After successful modeling, rats were administrated with corresponding agents via gavage for 7 days. Changes in colon length and colon weight were observed. Hematoxylin-eosin staining was performed to examine the pathological changes of the colon, and immunohistochemistry was employed to detect the expression of the inflammatory cytokine interleukin-8 (IL-8), cyclooxygenase-2 (COX-2), junction adhesion molecule-1 (JAM-1), and claudin-1 in the colon. Western blot analysis was performed to determine the protein levels of TLR4, MyD88, and NF-κB in the colon. ResultsCompared with the blank group, the model group showed elevated DAI score (P<0.01), reduced colon length and colon weight (P<0.01), down-regulated protein levels of JAM-1 and claudin-1 (P<0.01), and up-regulated protein levels of IL-8, COX-2, TLR4, MyD88, and NF-κB p65 (P<0.01) in the colon tissue. Compared with the model group, each treatment group showed decreased DAI score (P<0.05, P<0.01), increased colon length and colon weight (P<0.05, P<0.01), up-regulated protein levels of JAM-1 and claudin-1 (P<0.01), and down-regulated protein levels of IL-8, COX-2, TLR4, MyD88, and NF-κB p65 (P<0.01) in the colon tissue. ConclusionShaoyaotang alleviates intestinal inflammation and intestinal mucosal damage to protect intestinal barrier integrity by regulating the TLR4/MyD88/NF-κB signaling pathway.
3.Prevalence and related factors of screening myopia among students in special education schools in Tianjin
XI Wei, HAN Hui, XIONG Wenjuan, HAN Yu, WANG Hui, ZHANG Xin
Chinese Journal of School Health 2025;46(3):443-446
Objective:
To understand the current situation and related factors of screening myopia among students in special education schools, so as to provide evidence for promoting the health level of this population.
Methods:
From November 2021 to December 2023, a total of 281 students from 6 special education schools in 5 districts of Tianjin were selected by cluster random sampling method for computer optometry visual acuity examination for non ciliary paralysis and questionnaire survey. Multiple Logistic regression was performed to analyze the influencing factors of screening myopia among special education students.
Results:
The screening myopia detection rate among these special education students in Tianjin was 27.0%, and the screening myopia detection rates of students with autism, developmental delays, and intellectual disabilities were 22.4%, 12.5%, and 33.0%, respectively. The degree of myopia increased with age ( χ 2 trend =22.65, P <0.01). Multivariate Logistic regression analysis showed that age(10-13 years old: OR =5.40, 14-17 years old: OR =8.40, 18-23 years old: OR =6.02), accommodation(non resident: OR =0.29), daily mobile phone usage ≥2 hours ( OR =2.37), and daily computer/tablet usage ≥2 hours ( OR =2.70) were the risk factors for screening myopia among special education students ( P <0.05).
Conclusions
The detection rate and degree of screening myopia increase with age in special education students. Prolonged screen time exposure is a primary risk factor for screening myopia in special education students. Effective myopia prevention and control strategies should be designed according to the characteristics of special education students.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.The clinical efficacy of retrograde tibial intramedullary nail combined with lateral less invasive stabilization system in the treatment of distal femoral fractures
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Weibin LIN ; Jin WU
Chinese Journal of Orthopaedics 2025;45(4):197-204
Objective:To explore the clinical efficacy of retrograde tibial intramedullary nail (RTN) combined with less invasive stabilization system (LISS) in the treatment of distal femoral fractures.Methods:A retrospective analysis was conducted on the data of 11 patients with distal femoral fractures who underwent RTN combined with LISS locking plate treatment at the 909th Hospital from June 2021 to December 2022. There were 5 males and 6 females, with an average age of 56.5±17.5 years. The fracture types were AO/OTA 33A2 in 2 cases, A3 in 2 cases, C1 in 2 cases, and C2 in 2 cases. There were 3 cases of periprosthetic femoral fractures after total knee arthroplasty (TKA), all classified as Rorabeck type Ⅱ. They were treated with retrograde intramedullary nailing of the tibia combined with a minimally invasive lateral internal fixation system. The operation time, intraoperative blood loss, fracture healing time, full weight-bearing time, femorotibial angle, range of motion (ROM) of the knee joint, Hospital for Special Surgery (HSS) score, visual analogue scale (VAS) for pain, and complications were recorded.Results:The operation was successfully completed in all 11 cases. The operation time was 98.3±9.0 min (range 83-115 min), and the intraoperative blood loss was 167.8±24.3 ml (range 120-210 ml). All 11 cases were followed up for 11.0±1.9 months (range 9-15 months). The healing time of 11 cases was 5.3±0.8 months (range 4-6 months) after operation. The time of complete weight-bearing activity after operation was 55.7±6.5 d (range 46-67 d). At the last follow-up, the femoral-tibial angle of 11 cases was 171.2°±1.8° (range 169°-174°), the ROM of knee joint was 129.5°±4.7° (range 120°-135°), and the HSS score was 86.8±6.9 points (range 69-95 points). There were no major complications except for one case of superficial infection of surgical incision after operation.Conclusion:RTN combined with lateral LISS locking plate showed good clinical effect with the advantages of less trauma, reliable fixation, rapid recovery, less postoperative complications.
8.Analysis on revision points of GB 19083-2023 Protective face mask for medical use
Xiao-xiao HE ; Xiong-yi HUANG ; Li YANG ; Ning-rui ZHANG ; Qing-hui REN ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(1):73-77
The background of revising GB 19083-2023 Protective face mask for medical use was introduced.GB 19083-2023 was compared with GB 19083-2010 Technical requirements for protective face mask for medical use.The revision points were described in detail involving in dead space,total leakage rate,respiratory resistance,resistance to synthetic blood penetration,microbial indicators,biocompatibility and etc,and the convergence between GB 19083-2023 and international mainstream standards was analyzed.References were provided for the understanding of the standard for the production enterprises and consumers.[Chinese Medical Equipment Journal,2025,46(1):73-77]
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.


Result Analysis
Print
Save
E-mail