1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Prevalence and related factors of screening myopia among students in special education schools in Tianjin
XI Wei, HAN Hui, XIONG Wenjuan, HAN Yu, WANG Hui, ZHANG Xin
Chinese Journal of School Health 2025;46(3):443-446
Objective:
To understand the current situation and related factors of screening myopia among students in special education schools, so as to provide evidence for promoting the health level of this population.
Methods:
From November 2021 to December 2023, a total of 281 students from 6 special education schools in 5 districts of Tianjin were selected by cluster random sampling method for computer optometry visual acuity examination for non ciliary paralysis and questionnaire survey. Multiple Logistic regression was performed to analyze the influencing factors of screening myopia among special education students.
Results:
The screening myopia detection rate among these special education students in Tianjin was 27.0%, and the screening myopia detection rates of students with autism, developmental delays, and intellectual disabilities were 22.4%, 12.5%, and 33.0%, respectively. The degree of myopia increased with age ( χ 2 trend =22.65, P <0.01). Multivariate Logistic regression analysis showed that age(10-13 years old: OR =5.40, 14-17 years old: OR =8.40, 18-23 years old: OR =6.02), accommodation(non resident: OR =0.29), daily mobile phone usage ≥2 hours ( OR =2.37), and daily computer/tablet usage ≥2 hours ( OR =2.70) were the risk factors for screening myopia among special education students ( P <0.05).
Conclusions
The detection rate and degree of screening myopia increase with age in special education students. Prolonged screen time exposure is a primary risk factor for screening myopia in special education students. Effective myopia prevention and control strategies should be designed according to the characteristics of special education students.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
8.Effect and mechanism of LncRNA EFRL on homocysteine-induced atherosclerosis in macrophage efferocytosis.
Jiaqi YANG ; Zhenghao ZHANG ; Fang MA ; Tongtong XIA ; Honglin LIU ; Jiantuan XIONG ; Shengchao MA ; Yideng JIANG ; Yinju HAO
Chinese Journal of Cellular and Molecular Immunology 2025;41(7):577-584
Objective To investigate the effect and mechanism of Efferocytosis Relatived LncRNA (EFRL) on homocysteine-induced atherosclerosis in macrophage efferocytosis. Methods RAW264.7 cells were cultured in vitro, and the Control group (0 μmol/L Hcy) and Hcy intervention group (100 μmol/L Hcy) were set up. After GapmeR transfection of macrophages with Hcy intervention, EFRL knockdown negative control group (Hcy combined with LNA-NC) and EFRL knockdown group (Hcy combined with LNA-EFRL) were set up. High-throughput sequencing was applied for different expression of LncRNA MSTRG. 88917.16 (EFRL), UCSC was used to analyze its conservation, CPC and CPAT were used to analyze its ability to encode proteins, and GO and KEGG were used to analyze related biological functions. The localization of LncRNA EFRL in macrophages was analyzed by nucleoplasmic separation and RNA-FISH. Quantitative real-time PCR was used to detect the expression levels of LncRNA EFRL and its target gene SPAST in Hcy-treated macrophages. The apoptosis rate of Jurkat cells induced by UV was detected by flow cytometry. In vitro efferocytosis assay combined with immunofluorescence technique was used to analyze macrophage efferocytosis. ELISA was used to detect the levels of interleukin 1β(IL-1β) and IL-18. Results The new LncRNA MSTRG.88917.16 was identified and named EFRL(Efferocytosis Relatived LncRNA). UCSC, CPC and CPAT analyses showed that LncEFRL is highly conserved and does not have the ability to encode proteins. GO and KEGG analyses suggested that LncEFRL may be involved in macrophage efferocytosis. LncRNA EFRL was localized in the nucleus of macrophages as determined by nucleoplasmic separation and RNA-FISH. In comparison to the Control group, the expression levels of LncRNA EFRL and its target gene SPAST in the Hcy group were increased. In comparison to the Control group (0 min), the apoptosis rate of the experimental group (15, 30 min) Annexin V is more than 85%. Compared with Hcy combined with LNA-NC group, Hcy combined with LNA-EFRL group had enhanced macrophage efferocytosis and reduced levels of inflammatory factors. Compared with Hcy combined with LNA-NC group, the expression level of SPAST in Hcy combined with LNA-EFRL group was decreased. Conclusion Inhibition of EFRL expression can alleviate the process of Hcy inhibiting macrophage efferocytosis, and the mechanism is related to the regulation of the downstream target gene SPAST by EFRL.
RNA, Long Noncoding/physiology*
;
Animals
;
Homocysteine
;
Mice
;
Macrophages/drug effects*
;
Humans
;
RAW 264.7 Cells
;
Atherosclerosis/chemically induced*
;
Apoptosis/genetics*
;
Phagocytosis/genetics*
;
Jurkat Cells
;
Interleukin-1beta/genetics*
;
Efferocytosis
9.A preclinical and first-in-human study of superstable homogeneous radiolipiodol for revolutionizing interventional diagnosis and treatment of hepatocellular carcinoma.
Hu CHEN ; Yongfu XIONG ; Minglei TENG ; Yesen LI ; Deliang ZHANG ; Yongjun REN ; Zheng LI ; Hui LIU ; Xiaofei WEN ; Zhenjie LI ; Yang ZHANG ; Syed Faheem ASKARI RIZVI ; Rongqiang ZHUANG ; Jinxiong HUANG ; Suping LI ; Jingsong MAO ; Hongwei CHENG ; Gang LIU
Acta Pharmaceutica Sinica B 2025;15(10):5022-5035
Transarterial radioembolization (TARE) is a widely utilized therapeutic approach for hepatocellular carcinoma (HCC), however, the clinical implementation is constrained by the stringent preparation conditions of radioembolization agents. Herein, we incorporated the superstable homogeneous iodinated formulation technology (SHIFT), simultaneously utilizing an enhanced solvent form in a carbon dioxide supercritical fluid environment, to encapsulate radionuclides (such as 131I,177Lu, or 18F) with lipiodol for the preparation of radiolipiodol. The resulting radiolipiodol exhibited exceptional stability and ultra-high labeling efficiency (≥99%) and displayed notable intratumoral radionuclide retention and in vivo stability more than 2 weeks following locoregional injection in subcutaneous tumors in mice and orthotopic liver tumors in rats and rabbits. Given these encouraging findings, 18F was authorized as a radiotracer in radiolipiodol for clinical trials in HCC patients, and showed a favorable tumor accumulation, with a tumor-to-liver uptake ratio of ≥50 and minimal radionuclide leakage, confirming the feasibility of SHIFT for TARE applications. In the context of transforming from preclinical to clinical screening, the preparation of radiolipiodol by SHIFT represents an innovative physical strategy for radionuclide encapsulation. Hence, this work offers a reliable and efficient approach for TARE in HCC, showing considerable promise for clinical application (ChiCTR2400087731).
10.A Novel Mouse Model Unveils Protein Deficiency in Truncated CDKL5 Mutations.
Xue FENG ; Zi-Ai ZHU ; Hong-Tao WANG ; Hui-Wen ZHOU ; Ji-Wei LIU ; Ya SHEN ; Yu-Xian ZHANG ; Zhi-Qi XIONG
Neuroscience Bulletin 2025;41(5):805-820
Mutations in the cyclin-dependent kinase-like 5 gene (CDKL5) cause a severe neurodevelopmental disorder, yet the impact of truncating mutations remains unclear. Here, we introduce the Cdkl5492stop mouse model, mimicking C-terminal truncating mutations in patients. 492stop/Y mice exhibit altered dendritic spine morphology and spontaneous seizure-like behaviors, alongside other behavioral deficits. After creating cell lines with various Cdkl5 truncating mutations, we found that these mutations are regulated by the nonsense-mediated RNA decay pathway. Most truncating mutations result in CDKL5 protein loss, leading to multiple disease phenotypes, and offering new insights into the pathogenesis of CDKL5 disorder.
Animals
;
Disease Models, Animal
;
Mice
;
Protein Serine-Threonine Kinases/deficiency*
;
Mutation/genetics*
;
Epileptic Syndromes/genetics*
;
Humans
;
Dendritic Spines/pathology*
;
Spasms, Infantile/genetics*
;
Male
;
Seizures/genetics*
;
Mice, Inbred C57BL


Result Analysis
Print
Save
E-mail