1.Overview of the amendments and revisions to the General Technical Requirements adopted by the Volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition
ZHANG Jun ; NING Baoming ; WEI Shifeng ; SHEN Haoyu ; SHANG Yue ; ZHU Ran ; XU Xinyi ; CHEN Lei ; LIU Tingting ; MA Shuangcheng
Drug Standards of China 2025;26(1):034-044
To introduce the general thinking, guidelines, work objectives and elaboration process of the general technical requirements adopted by volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition, and to summarize and figure out the main characteristics on dosage forms, physico-chemical testing, microbial and biological testing, reference standards and guidelines The newly revised general chapters of pharmacopoeia give full play to the normative and guiding role of the Chinese Pharmacopoeia standard, track the frontier dynamics of international drug regulatory science and the elaboration of monographs, expand the application of state-of-the-art technologies, and steadily promote the harmonization and unification with the ICH guidelines; further enhance the overall capacity of TCM quality control, actively implement the 3 R principles on animal experiments, and practice the concept of environmental-friendly; replace and/or reduce the use of toxic and hazardous reagents, strengthen the requirements of drug safety control This paper aims to provide a full-view perspective for the comprehensive, correct understanding and accurate implementation of general technical requirements included in the Chinese Pharmacopoeia 2025 Edition.
2.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
XU Xinyi ; WEI Shifeng ; ZHANG Qiming ; HE Langchong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):045-050
Objective: To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Methods: Introduce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Results: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guidelines of the ICH Q series, and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety, efficacy, and quality controllability is further increased.
Conclusion: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China’s drugs to go international, standardized testing technology support for achieving full process quality control, and better meet the needs of drug research and development, production, quality control, and supervision in China.
3.Clinical observation and anti-drug antibody monitoring of enzyme replacement therapy in children with Fabry disease
Zhihong LU ; Xinyi SHOU ; Qian LIN ; Lingxia ZHANG ; Haidong FU ; Jianhua MAO
Chinese Journal of Pediatrics 2025;63(1):75-79
Objective:To analyze the efficacy of enzyme replacement therapy and anti-drug antibody production in children with Fabry disease.Methods:The clinical data of 7 children with Fabry disease treated with enzyme replacement therapy for more than 1 year at Children′s Hospital of Zhejiang University School of Medicine from July 2021 to June 2024 were retrospectively analyzed. The basic information and the changes of related clinical indicators before and after treatment were collected. Paired sample t test was used to compare renal function, left heart mass index, pain score and other related indexes before and after treatment. The anti-drug antibodies were detected by enzyme-linked immunosorbent assay. Results:A total of 6 boys and 1 girl were included. The age of diagnosis was (12.2±1.8) years. After 1 year of enzyme replacement therapy, the abnormal substrate globotriaosylsphingosine and brief pain inventory scores of all children were significantly lower than those before treatment ((16±11) vs. (63±42) μg/L, 22±19 vs. 45±29, t=3.88, 3.43, both P<0.05). There were no significant differences in glomerular filtration rate, urinary microalbumin to creatinine and left heart mass index before and after treatment ((124±35) vs. (136±26) ml/(min·1.73 m 2), (9.3±8.3) vs. (3.8±2.5) mg/g, (38±9) vs. (33±6) g/m 2.7, t=1.33, 1.74, 1.19, all P>0.05). Patients 4, 5 and 6 developed anti-drug antibodies at 1 month, 4 months and 1 month after medication, respectively. Patient 4 had persistently high anti-drug antibody titers (absorbance 3.65-3.73) accompanied by urticaria, elevated globotriaosylsphingosine and worsening clinical symptoms. Conclusions:The enzyme replacement therapy can effectively improve the clinical symptoms and reduce the level of globotriaosylsphingosine in children with Fabry disease. The anti-drug antibody is common in patients after long-term enzyme replacement therapy and may diminish the efficacy, which needs dynamic monitoring.
4.Pharmacodynamic Substances and Mechanisms of Da Chengqitang in Treating Stroke: A Review
Yizhi YAN ; Xinyi LIU ; Yang DUAN ; Miaoqing LONG ; Chaoya LI ; Qiang LI ; Yi'an CHEN ; Shasha YANG ; Yue ZHANG ; Peng ZENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):297-306
Stroke is the main cause of death and disability among adults in China and is characterized by high incidence, disability, mortality, and recurrence rates. The combination of traditional Chinese and Western medicine has great potential in treating stroke and its sequelae. The classic traditional Chinese medicine prescription Da Chengqitang (DCQT) has a long history and proven efficacy in treating stroke. Clinically, DCQT is often used to treat stroke and its sequelae. However, the number and quality of clinical trials of DCQT in treating stroke need to be improved. Because of the insufficient basic research, the active ingredients and multi-target mechanism of action of DCQT remain unclear. Our research group has previously confirmed that DCQT can effectively reverse neurological damage, reduce iron deposition, and downregulate the levels of pro-inflammatory cytokines in the rat model of hemorrhagic stroke. The treatment mechanism is related to the nuclear factor erythroid 2-related factor 2 (Nrf2)-mediated signaling pathway and p38 mitogen-activated protein kinase (MAPK) signaling-mediated microglia activation. To clarify the pharmacodynamic basis and anti-stroke mechanism of DCQT, this article reviews the research progress in the treatment of stroke with DCQT in terms of clinical trials, pharmacodynamic material basis, safety evaluation, and mechanisms of absorbed components. This article summarizes 45 major phytochemical components of DCQT, 11 of which are currently confirmed absorbed components. Among them, emodin, rhein, chrysophanol, aloe-emodin, synephrine, hesperidin, naringin, magnolol, and honokiol can be used as quality markers (Q-markers) of DCQT. The mechanism of DCQT in treating stroke is complex, involving regulation of inflammatory responses, neuronal damage, oxidative stress, blood-brain barrier, brain-derived neurotrophic factor, and anti-platelet aggregation. This article helps to deeply understand the pharmacodynamic basis and mechanism of DCQT in treating stroke and provides a theoretical basis for the clinical application of DCQT in treating stroke and the development of stroke drugs.
5.Application of time series and machine learning models in predicting the trend of sickness absenteeism among primary and secondary school students in Shanghai
WANG Zhengzhong, ZHANG Zhe, ZHOU Xinyi, YUAN Linlin, ZHAI Yani, SUN Lijing, LUO Chunyan
Chinese Journal of School Health 2025;46(3):426-430
Objective:
To analyze the temporal variation patterns of sickness absenteeism among primary and secondary school students in Shanghai, so as to explore models suitable for predicting peaks and intensity of absenteeism rates.
Methods:
The seasonal and trend decomposition using loess (STL) method was used to analyze the seasonal and long term trend changes in sickness absenteeism among primary and secondary school students from September 1 in 2010 to June 30 in 2018, in Shanghai. A hierarchical clustering method based on Dynamic Time Warping (DTW) was employed to classify absenteeism symptoms with similar temporal patterns. Based on historical data, the study constructed and evaluated different time series algorithms and machine learning models to optimize the accuracy of predicting the trend of sickness absenteeism.
Results:
During the research period, the average new absenteeism rate due to illness was 16.86 per 10 000 person day for every academic year, and the trend of sickness absenteeism exhibited both seasonality and a long term upward trend, reaching its highest point in the 2017 academic year (22.47 per 10 000 person day). The symptoms of absenteeism were divided into three categories: high incidence in winter and spring (respiratory symptoms, fever and general discomfort, etc.), high incidence in summer (eye symptoms, nosebleeds, etc.) and those without obvious seasonality (skin symptoms, accidental injuries, etc.).The constructed time series models effectively predicted the trend of absenteeism due to illness, although the accuracy of predicting peak intensity was relatively low. Among them, the multi layer perceptron (MLP) model performed the best, with an root mean squared error (RMSE) of 8.96 and an mean absolute error (MAE) of 4.37, reducing 36.51% and 39.02% compared to the baseline model.
Conclusion
Time series models and machine learning algorithms could effectively predict the trend of sickness absenteeism, and corresponding prevention and control measures can be taken for absenteeism caused by different symptoms during peak periods.
6.Traditional Chinese medicine phenomics research on glycolipid metabolism disorder: a review
Xinyi FANG ; Linxuan MIAO ; Yanjiao ZHANG ; Yuxin ZHANG ; Runyu MIAO ; Huifang GUAN ; Jiaxing TIAN
Digital Chinese Medicine 2025;8(1):49-58
Abstract
Traditional Chinese medicine (TCM) has demonstrated unique advantages in the prevention and treatment of chronic diseases such as glycolipid metabolism disorder. However, its widespread application has been hindered by the unclear biological essence of TCM syndromes and therapeutic mechanisms. As an emerging interdisciplinary field, phenomics integrates multi-dimensional data including genome, transcriptome, proteome, metabolome, and microbiome. When combined with TCM's holistic philosophy, it forms TCM phenomics, providing novel approaches to reveal the biological connotation of TCM syndromes and the mechanisms of herbal medicine. Taking glycolipid metabolism disorder as an example, this paper explores the application of TCM phenomics in glycolipid metabolism disorder. By analyzing molecular characteristics of related syndromes, TCM phenomics identifies differentially expressed genes, metabolites, and gut microbiota biomarkers to elucidate the dynamic evolution patterns of syndromes. Simultaneously, it deciphers the multi-target regulatory networks of herbal formulas, demonstrating their therapeutic effects through mechanisms including modulation of insulin signaling pathways, improvement of gut microbiota imbalance, and suppression of inflammatory responses. Current challenges include the subjective nature of syndrome diagnosis, insufficient standardization of animal models, and lack of integrated multi-omics analysis. Future research should employ machine learning, multimodal data integration, and cross-omics longitudinal studies to establish quantitative diagnostic systems for syndromes, promote the integration of precision medicine in TCM and western medicine, and accelerate the modernization of TCM.
7.A new method for flow cytometry-based detection of ABO antigen expression levels
Yuyu ZHANG ; Xi LIU ; Junhua XIE ; Bin CAO ; Jiewei ZHENG ; Xinyi ZHU ; Zhongying WANG ; Dong XIANG
Chinese Journal of Blood Transfusion 2025;38(5):665-672
Objective: To design and establish a new method for flow cytometry-based detection of commonly observed highly expressed antigens on red blood cells, and to further evaluate the differences and distribution characteristics of antigen expression levels between ABO blood type homozygotes and heterozygotes in healthy individuals. Methods: Residual blood samples after donor blood type identification by Shanghai Blood Center in April 2024 were collected. Among them, samples of 19 homozygous and 19 heterozygous individuals of type A and type B were selected. Then the expression level of ABO antigen on red blood cells were detected using the new method established in this study and the traditional aldehyde fixed red blood cell method. Both methods were tested independently three times and the results were compared. Results: The mean values of the three detection results of the new method was (×10
/RBC): AA homozygous 3.3±0.5, AO heterozygous 2.8±0.3, BB homozygous 3.6±0.3, BO heterozygous 3.1±2.8. The mean values of the three detection results of the aldehyde fixation method were AA homozygous 5.9±0.9, AO heterozygous 5.0±1.4, BB homozygous 3.8±0.6, and BO heterozygous 3.3±0.4. The average antigen distribution of each genotype followed a normal distribution. Comparing the average antigen expression levels of homozygotes and heterozygotes, both methods showed that A/B homozygotes had higher antigen levels than heterozygotes, with AA being 1.17 to 1.18 times that of AO and BB being 1.15 to 1.16 times that of BO. Comparing the inter batch differences in the three test results of two methods, the new method showed no significant difference in the three test results for four genotypes (P>0.05). The aldehyde fixation method showed significant differences in the test results for all three genotypes (P<0.01) except for BB homozygotes (P>0.05). The reliability and reproducibility of the new method were better than those of the traditional aldehyde fixation method. Conclusion: The antigen expression level of ABO homozygotes is higher than that of heterozygotes, and the difference in antigen level between type A homozygotes and heterozygotes is slightly higher than that of type B. The new method is superior to traditional aldolization fixation methods.
8.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
9.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
10.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.


Result Analysis
Print
Save
E-mail