1.Current Status and Prospective of Research on Disease-Syndrome Integrated Animal Models of Spleen and Stomach Diseases in Traditional Chinese Medicine
Jiaqi ZHANG ; Lihui FANG ; Yongtian WEN ; Shan LIU ; Zhuo SHI ; Xintong WANG ; Xinyi DAI ; Meiling SHE ; Lanshuo HU ; Yangxi FU ; Zheng WANG ; Fengyun WANG ; Xudong TANG
Journal of Traditional Chinese Medicine 2026;67(5):510-516
Animal model research on spleen and stomach diseases in traditional Chinese medicine (TCM) is of great significance for elucidating the nature of diseases and syndromes and for revealing the mechanisms of action of Chinese herbal medicinals. At present, studies on classical TCM syndrome models of spleen and stomach diseases mainly focus on spleen deficiency syndrome, liver constraint syndrome, and damp-heat syndrome. Model construction is mostly based on the etiological and pathophysiological characteristics of syndrome, and model evaluation primarily involves macroscopic manifestations and physicochemical indicators. This paper summarizes the current research status of animal models integrating disease and syndrome for seven common spleen and stomach diseases, including chronic gastritis and gastric precancerous lesions, gastroesophageal reflux disease, functional dyspepsia, inflammatory bowel disease, irritable bowel syndrome, functional constipation, and functional diarrhea. The modeling methods and characteristics of disease-syndrome combined animal models for each disease are analyzed. It is proposed that future research on disease-syndrome integration in spleen and stomach diseases should move toward syste-matic, precise, and integrative development, and that interdisciplinary and cross-disciplinary research approaches should be adopted to enhance the predictive value and application efficiency of disease-syndrome combined animal models.
2.Influencing Factors of Depression in Patients with Postoperative Ovarian Cancer
Jialiang YAO ; Long ZHANG ; Jianhui TIAN ; Ze LIU ; Yun YANG ; Yiyang ZHOU ; Minghua LI ; Wang YAO ; Wenfei SHI ; Xinyi LU ; Pan YU ; Enchao CONG
Cancer Research on Prevention and Treatment 2026;53(5):349-359
Objective To explore the prevalence of depressive symptoms in postoperative patients with ovarian cancer and to analyze its influencing factors from multiple dimensions, including clinical characteristics, psychological factors, and laboratory indicators. Methods A cross-sectional study was conducted, which enrolled 235 postoperative patients with ovarian cancer. Depressive status was assessed using the patient health questionnaire, and the demographic, pathological, and medical record data of the patients were collected using the generalized anxiety disorder scale, Pittsburgh sleep quality index, European organization for research and treatment of cancer quality of life questionnaire core 30, and ECOG performance status score. Peripheral blood tumor marker (CA125), routine blood test, lymphocyte subsets, and serum cytokine levels were measured. Univariate and multivariate binary logistic regression analysis were used for statistical analysis. Results The prevalence of depression in postoperative patients with ovarian cancer was 39.15% (92/235). Univariate analysis showed that ECOG score ≥ 2 points, pain, anxiety, poor sleep quality, low quality of life, low life satisfaction, tumor recurrence, six or more cycles of chemotherapy, as well as higher levels of CA125, NLR, and NAR, and lower hemoglobin levels were significantly associated with depression (all P<0.05). Multivariate binary Logistic regression analysis showed that anxiety (OR=1.975, 95%CI: 1.231-3.170), sleep efficiency (OR=4.181, 95%CI: 1.211-14.43), sleep latency (OR=34.806, 95%CI: 4.258-284.542), ECOG performance status score, cognitive function (OR=0.918, 95%CI: 0.868-0.97), and life satisfaction were independent risk factors for depression (all P<0.05). Laboratory indicators were not independent influencing factors in the multivariate Logistic regression model. Conclusion Depression in postoperative patients with ovarian cancer is influenced by physiological, psychological, and social factors. Clinical management should focus on patients with anxiety, sleep disorders, poor physical condition, and low life satisfaction, and a comprehensive prevention and treatment strategy centered on psychological intervention and taking into account symptom management and social support should be implemented.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.A study on the coercive experience of involuntarily hospitalized adolescents with mental disorders
Lingyu LI ; Xinyi LIU ; Jiawei SHI ; Gen CHENG ; Haiou ZOU
Chinese Medical Ethics 2025;38(2):232-240
ObjectiveTo explore the coercive experience of involuntarily hospitalized adolescents with mental disorders during the admission process and hospitalization, providing references for formulating targeted nursing interventions. MethodsSemi-structured interviews were conducted with 15 involuntarily hospitalized adolescents with mental disorders selected from October to December 2023, and the themes were summarized and extracted by content analysis. ResultsA total of 3 themes and 10 sub-themes were extracted, which were used to elaborate the essential contents, causes, and improvement methods of coercive experience. These encompassed the multi-dimensional content of coercive experience (complex emotional experience, different physical sensations, and contradictory cognitive evaluation), the multi-faceted causes of coercive experience (insufficient personal preparation, inadequate parental communication, and strict medical management system), as well as the phased improvement of coercive experience (adequate communication before hospitalization, patient notification before coercive intervention, respecting for demands during coercive intervention, and comforting explanation after coercive intervention). ConclusionThe essential content of the coercive experience of involuntarily hospitalized adolescents with mental disorders is complex and has various causes, which require cooperation from multiple parties to improve. Therefore, parents should respect the expression of their children’s self-will, and medical staff should respect patients’ autonomy, establishing a protection-constrained doctor-patient relationship model and collaborating to reduce the use of coercive interventions, to improve the overall medical satisfaction of adolescents with mental disorders.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
8.Expression and clinical significance of serum tumor-associated antigens in patients with rheumatoid arthritis
Ying XIA ; Yu TANG ; Xinyi ZHA ; Yanru WANG ; Wei SHI ; Xun GONG ; Yingying QIU ; Xiaoming FEI
Journal of Clinical Medicine in Practice 2025;29(9):1-6
Objective To investigate the expression of serum tumor-associated antigens(TAAs)in patients with rheumatoid arthritis(RA)and analyze their clinical significance for RA.Methods A total of 214 RA patients were enrolled in the RA group,while 198 age-and gender-matched healthy individuals were included in the HC group.Rheumatoid factor(RF),anti-cyclic citrullinated peptide antibody(Anti-CCP),C-reactive protein(CRP),erythrocyte sedimentation rate(ESR),interleu-kin-6(IL-6),ferritin levels,as well as gender,age,disease duration,disease activity score(DAS28)and clinical manifestations were collected from the RA group.The expression of TAAs in RA patients and the clinical characteristics of TAA-positive patients were analyzed.Spearman correla-tion analysis was used to evaluate the relationships between TAAs and clinical indicators in RA pa-tients.Results The positive rate of carbohydrate antigen 125(CA125)in the RA group was 8.88%,which was significantly higher than 1.01% in the HC group(P<0.001).Serum CA125 and cytok-eratin fragment 19(CYFRA21-1)levels in the RA group were significantly higher than those in the HC group,whereas alpha-fetoprotein(AFP),carcinoembryonic antigen(CEA),carbohydrate anti-gen 199(CA199)and neuron-specific enolase(NSE)levels were significantly lower(P<0.001).TAA-positive patients had significantly older age and higher rates of pulmonary interstitial lesions compared to TAA-negative patients(P<0.05).Patients with DAS28 scores>5.1 had significantly higher CA125 levels than those with DAS28 scores ≤5.1(P<0.05).CA125 levelswere positively corre-lated with DAS28 scores,ESR,RF,and anti-CCP antibodies(r=0.142,0.140,0.268,0.183;P<0.05).Conclusion In RA patients,the positivity rate and levels of some serum TAAs are ele-vated,and TAA-positive patients tend to be older and have higher incidence of pulmonary interstitial lesions.CA125 levels are positively correlated with RA disease activity.
9.Clinical characteristics and contributors to diagnostic delay in autoimmune gastritis
Haofeng LI ; He MA ; Tao FU ; Xinyi HUANG ; Qing SHI ; Yan ZHENG ; Hanning LIU ; Hengqi LIU ; Yan GUO ; Chunhui LAN
Journal of Army Medical University 2025;47(19):2396-2404
Objective To analyze the diagnostic process and clinical characteristics of autoimmune gastritis(AIG)in order to improve the awareness and diagnostic proficiency of this disease.Methods A retrospective cohort study was conducted on 114 patients diagnosed with AIG in Army Medical Center of PLA between January 2021 and June 2024.Comprehensive statistical analysis was performed on clinical data,including demographic characteristics(age,sex),clinical symptoms,comorbidities,diagnostic process,Helicobacter pylori(H.pylori)infection and treatment history,laboratory indicators[results of routine blood test,anemia-related indices,thyroid function,anti-parietal cell antibody(APCA),intrinsic factor antibody(IFA)],and gastrointestinal endoscopic findings(frequency and endoscopic features).Results Among the 114 patients,males accounted for 28.1%(32/114)and females for 71.9%(82/114),and they were at a mean age of 56.3±8.4 years.Predominant symptoms included epigastric/upper abdominal pain(47.4%,54/114)and postprandial fullness(43.0%,49/114),while 24.6%(28/114)reported acid reflux or heartburn.Diagnostic delay occurred in 76.4%(87/114)of patients,with a median delay duration of 11.5 months.Primary diagnostic clues were endoscopic reverse gradient atrophy(significantly more severe mucosal atrophy in the gastric corpus/fundus versus antrum;53.5%,61/114)and repeated H.pylori eradication failure(≥2 attempts;22.8%,26/114).Positivity rate of thyroid peroxidase antibody(TPOAb)and thyroglobulin antibody(TgAb)was 56.9%(33/58)and 36.2%(21/58),respectively.APCA positive rate was 98.8%(81/82),IFA positive rate was 34.1%(28/82),and dual-antibody rate was 32.9%(27/82).Anemia was present in 25.7%(26/101)of the patients.Gastric neuroendocrine tumors(NET)were found in 12.2%(14/114),intraepithelial neoplasia in 5.3%(6/114),and gastric adenocarcinoma in 0.9%(1/114).Among colonoscopy-examined patients,tubular adenomas occurred in 25.0%(13/52)and colorectal malignancies in 3.4%(2/58).There were 18.4%(21/114)patients having gallbladder-related diseases,7.9%(9/114)having diabetes mellitus,and 1.8%(2/114)of subacute combined degeneration of the spinal cord.Conclusion AIG is frequently associated with diagnostic delay.The reverse pattern of atrophy on endoscopy serves as a critical diagnostic clue,necessitating enhanced recognition in endoscopists.Patients with recurrent H.pylori eradication failure(≥2 attempts)should be evaluated for AIG.
10.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.

Result Analysis
Print
Save
E-mail