1.Evaluation on reliability and validity of Chinese revised version of the Benevolent Childhood Experiences Scale among college students
TIAN Susu, HU Xinyi, LIU Yuxuan, TIAN Jiayi, WANG Yingxue, WANG Yihan, WANG Wei
Chinese Journal of School Health 2026;47(3):365-368
Objective:
To revise and validate the reliability and validity of Chinese version of the Benevolent Childhood Experiences (BCEs) Scale among college students, so as to provide a scientific and reliable assessment tool for related research.
Methods:
From April to June 2025, a stratified cluster random sampling method was used to select 1 677 freshmen from a university in Xuzhou City as participants. The survey was conducted by using the revised Benevolent Childhood Experiences (BCEs) Scale, Childhood Trauma Questionnaire (CTQ) and Brief Suicidal Behavior Scale. Reliability analysis, exploratory factor analysis (EFA), confirmatory factor analysis (CFA), Spearman correlation analysis, and hierarchical linear regression analysis were employed to evaluate the scale s reliability, validity, and relationships among variables.
Results:
The mean scores of the 10 items on the BCEs Scale ranged from 3.97 to 4.46, with standard deviations ranging from 0.88 to 1.07. The Cronbach α coefficient was 0.96. Exploratory factor analysis extracted a single factor, explaining 71.21% of the total variance. Confirmatory factor analysis indicated good model fit ( χ 2/df =4.81, goodness of fit index=0.99, comparative fit index=0.99, normed fit index=0.99, root mean square error of approximation=0.05, standardized root mean square residual=0.01). BCEs total scores were negatively correlated with CTQ total scores and all its dimensions among college students ( r =-0.53 to -0.13, all P < 0.01). Hierarchical regression analysis showed that BCEs moderated the effect of CTQ on suicidal behavior, with a statistically significant interaction ( β=-0.11, t=-4.01, P <0.01).
Conclusion
The Chinese revised version of the BCEs Scale demonstrates good reliability and validity, and it is suitable for assessing BCEs among Chinese college students.
2.Current Status and Prospective of Research on Disease-Syndrome Integrated Animal Models of Spleen and Stomach Diseases in Traditional Chinese Medicine
Jiaqi ZHANG ; Lihui FANG ; Yongtian WEN ; Shan LIU ; Zhuo SHI ; Xintong WANG ; Xinyi DAI ; Meiling SHE ; Lanshuo HU ; Yangxi FU ; Zheng WANG ; Fengyun WANG ; Xudong TANG
Journal of Traditional Chinese Medicine 2026;67(5):510-516
Animal model research on spleen and stomach diseases in traditional Chinese medicine (TCM) is of great significance for elucidating the nature of diseases and syndromes and for revealing the mechanisms of action of Chinese herbal medicinals. At present, studies on classical TCM syndrome models of spleen and stomach diseases mainly focus on spleen deficiency syndrome, liver constraint syndrome, and damp-heat syndrome. Model construction is mostly based on the etiological and pathophysiological characteristics of syndrome, and model evaluation primarily involves macroscopic manifestations and physicochemical indicators. This paper summarizes the current research status of animal models integrating disease and syndrome for seven common spleen and stomach diseases, including chronic gastritis and gastric precancerous lesions, gastroesophageal reflux disease, functional dyspepsia, inflammatory bowel disease, irritable bowel syndrome, functional constipation, and functional diarrhea. The modeling methods and characteristics of disease-syndrome combined animal models for each disease are analyzed. It is proposed that future research on disease-syndrome integration in spleen and stomach diseases should move toward syste-matic, precise, and integrative development, and that interdisciplinary and cross-disciplinary research approaches should be adopted to enhance the predictive value and application efficiency of disease-syndrome combined animal models.
3.Erchentang Ameliorates SiO2-induced Lung Injury by Regulating Oxidative Stress and Metabolic Disorders via Nrf2/HO-1 Signaling Pathway
Jun LU ; Xinyi ZHU ; Ziyi LIU ; Jixia HU ; Jialu CHEN ; Rong XIAO ; Zhibin WANG ; Chang LIU ; Fangguo LU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):32-42
ObjectiveTo observe the protective effect of Erchentang (ECT) on SiO2-induced lung injury in rats and to explore its underlying mechanism. MethodsA rat model of lung injury was established by a single intratracheal instillation of 50 mg·mL-1 SiO2 suspension. Thirty male Sprague-Dawley (SD) rats were randomly assigned to five groups: control, model, low and high-dose (4.5 g·kg-1·d-1 and 9 g·kg-1·d-1, respectively) ECT, and dexamethasone (0.2 mg·kg-1·d-1). All the groups were treated for 4 consecutive weeks. Histopathological alterations in the lung tissue were examined by hematoxylin and eosin (HE) staining. The levels of malondialdehyde (MDA), superoxide dismutase (SOD), and glutathione peroxidase (GSH-Px) in the lung tissue were measured through biochemical assays. The expression of key molecules in the nuclear factor erythroid 2-related factor 2 (Nrf2)/heme oxygenase-1 (HO-1) pathway was determined by Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR), Western blot, and immunofluorescence assay. The primary active components of ECT were identified by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and their binding affinity to Nrf2/HO-1 was assessed by molecular docking. Untargeted metabolomics of the lung tissue was performed based on UPLC-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS), and correlation analysis was performed to identify differential metabolites and parameters closely associated with the Nrf2/HO-1 pathway. ResultsCompared with the control group, the model group exhibited a reduction in body weight gain, an increase in lung index, increased MDA content, weakened SOD and GSH-Px activities in the lung tissue, down-regulated mRNA and protein levels of Nrf2 and protein levels of HO-1 and GPX4, and an up-regulated protein level of Keap1 (P<0.05, P<0.01). Treatment with ECT attenuated the SiO2-induced decline in body weight (P<0.05), alleviated inflammatory cell infiltration and silicotic nodule formation in alveoli, and reduced the MDA content and enhanced the SOD and GSH-Px activities in the lung tissue (P<0.05, P<0.01). UPLC-MS/MS and molecular docking revealed that core components of ECT, such as hesperidin and glycyrrhizic acid, displayed strong binding affinity to Nrf2/HO-1. Molecular biological experiments demonstrated that ECT promoted nuclear translocation of Nrf2, up-regulated the mRNA and protein levels of HO-1 and GPX4, and down-regulated Keap1 expression (P<0.05, P<0.01). Metabolomic analysis indicated that ECT reversed the SiO2-induced aberrant expression of metabolites, including linoleic acid and glutamine (P<0.05, P<0.01). Correlation analysis showed that Nrf2 and HO-1 were positively correlated with SOD and GSH-Px (P<0.05, P<0.01), but negatively correlated with glutamine and serine (P<0.05, P<0.01). ConclusionECT may activate the Nrf2/HO-1 pathway through its core active components, thereby regulating oxidative stress and metabolic disorders to ameliorate SiO2-induced lung injury in rats. This study provides experimental evidence for ECT in the prevention and treatment of occupational lung injury.
4.Alterations in white matter free water in anti-N-methyl-D-aspartate receptor encephalitis
Jie Hu ; Xin Wang ; Yuanyuan Guo ; Xinyi Lv ; Siyu Fan ; Yanghua Tian
Acta Universitatis Medicinalis Anhui 2025;60(7):1225-1230
Objective :
To analyze the distribution characteristics of free water ( FW) and FW-corrected fractional anisotropy (FAt) in the white matter of the brain in patients with anti-N-methyl-D-aspartate receptor ( NMDAR) encephalitis and to explore their correlation with cognitive function.
Methods :
A total of 38 patients with anti- NMDAR encephalitis and 30 controls were recruited from three hospitals in Hefei.Diffusion tensor imaging data and neuropsychological assessment results were collected.Tract-Based Spatial Statistics was applied to compare group differences in FW and FAt across the whole brain white matter.Correlation analyses were further performed to ex- amine the relationships between FW/ FAt metrics and cognitive function.
Results :
Compared to the control group, patients with anti-NMDAR encephalitis showed significantly lower scores on the montreal cognitive assessment,im- mediate recall,delayed recall,and the verbal fluency test (all P<0. 05) ,as well as significantly longer comple- tion times for color naming and word reading tasks in the stroop color word test (all P<0. 05) .Diffusion tensor im- aging analysis revealed significantly elevated FW and reduced FAt in widespread white matter regions in the patient group (all P<0. 000 1) .Further correlation analysis showed that increased FW was positively associated with the completion time of the color-switching condition in the color digital trail making test (P = 0. 044 ) and with the difference between color-switching and number sequencing conditions ( P = 0. 016 ) ,while negatively correlated with semantic fluency scores (P = 0. 002) .Additionally,FAt was positively associated with delayed recall perform- ance (P = 0. 012) ,and negatively correlated with the completion times for color naming (P = 0. 018 ) and word reading (P = 0. 046) tasks in the SCWT.
Conclusion
Patients with anti-NMDAR encephalitis exhibit significantly elevated FW and significantly reduced FAt in white matter tracts,both of which are closely linked to cognitive im- pairment.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
7.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
8.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
9.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
10.Silent or low expression of bla TEM and bla SHV suggests potential for targeted proteomics in clinical detection of β-lactamase-related antimicrobial resistance.
Huige WU ; Wenting DONG ; Xinxin HU ; Chunyang XIE ; Xinyi YANG ; Congran LI ; Guoqing LI ; Yun LU ; Xuefu YOU
Journal of Pharmaceutical Analysis 2025;15(7):101220-101220
Image 1.


Result Analysis
Print
Save
E-mail