1.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Surveillance and analysis of microbial contamination in commercially available ready-to-eat foods in Songjiang District, Shanghai from 2017 to 2022
Xiang QIU ; Yuxing ZHU ; Xinyi GU ; Fengsong SHENG ; Yuanqiang JIANG
Shanghai Journal of Preventive Medicine 2025;37(3):255-259
ObjectiveTo investigate the microbial contamination status of commercially available ready-to-eat (RTE) foods in Songjiang District of Shanghai, to verify the potential food safety hazards, so as to provide a scientific basis for the local regulation of RTE foods and the prevention of foodborne diseases. MethodsA total of 882 food samples from 9 categories of RTE foods were collected in Shanghai from 2017 to 2022. Salmonella, Listeria monocytogenes, Vibrio parahaemolyticus, Staphyloccus aureus and Bacillus cereus were detected according to the standard operating procedures in the Manual for China National Food Contamination and Harmful Factors Risk Monitoring, and which were determined with reference to relevant standards. ResultsA total of 77 samples were found to carry foodborne pathogens, with a total detection rate of 8.73%. Among the 5 foodborne pathogens, Bacillus cereus had the highest detection rate (8.35%), followed by Vibrio parahaemolyticus (5.05%), and the difference of detection rates among the 5 foodborne pathogens was statistically significant (χ2=112.307, P<0.001). Among the 9 categories of RTE food products, the detection rate of foodborne pathogens in RTE fermented/non-fermented soybean products was the highest (27.50%), followed by cold noodles (17.33%) and raw edible aquatic products (9.50%), and the difference in the detection rates of foodborne pathogens among different RTE food categories was statistically significant (χ2=45.909, P<0.001). The detection rate of foodborne pathogens in the third quarter of the year was 10.99%, significantly higher than that in other quarters (χ2=10.329, P=0.016). The detection rate of foodborne pathogens in samples from supermarkets was highest (15.08%), followed by snack bars (11.58%), with a statistically significant difference (χ2=14.108, P=0.015). ConclusionFoodborne pathogens contamination is found in commercially available RTE foods in Songjiang District of Shanghai, especially in RTE fermented/non-fermented soybean products, RTE cold noodles and raw edible aquatic products from supermarkets, snack bars and farm products markets during summer and autumn. Therefore, it is crucial to strengthen supervision and management to avoid the foodborne diseases.
7.Transparency of clinical practice guidelines: A mixed methods research.
Xinyi WANG ; Youlin LONG ; Tengyue HU ; Zixin YANG ; Liqin LIU ; Liu YANG ; Yifan CHENG ; Ran GU ; Yanjiao SHEN ; Nan YANG ; Jin HUANG ; Yaolong CHEN ; Liang DU
Chinese Medical Journal 2025;138(15):1882-1884
8.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
9.Compatibility Theory of Yiqi Zengmian Prescription as Vaccine Adjuvant
Xinyi GU ; Lin TONG ; Shihuan TANG ; Hui LI ; Ruili HUO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(1):208-215
ObjectiveThis study explored the application of Yiqi Zengmian prescription as a vaccine adjuvant, aiming to provide a new scheme for the prevention and control of corona virus disease 2019(COVID-19) with traditional Chinese medicine (TCM). By analyzing the compatibility and efficacy, this paper examines the compatibility effect of Yiqi Zengmian prescription, which is modified from the classic tonifying agent Si Junzitang, as a vaccine adjuvant. MethodUsing the Database of Ancient Classical Prescriptions, this paper analyzed the composition of Yiqi Zengmian prescription and probed into the theoretical basis for the compatibility of this prescription from the properties, medicine combination, and efficacy. Furthermore, the compatibility effect of this prescription with vaccines was analyzed. ResultAs a TCM prescription, Yiqi Zengmian prescription focuses on the lung and spleen and enhances the Qi in the two organs. The lung governs Qi movement. The body breathes fresh air through the lungs and exchanges the turbid gas in the lungs, and the gas circulates alternately in the lungs to ensure the normal breathing of the human body. The spleen governing transportation and transformation is the hub for Qi movement, and Qi is the embodiment of metabolic function. By regulating qi movement and enhancing the functions of Qi and blood, Yiqi Zengmian prescription can enhance the immunogenicity of the vaccine, which provides a theoretical basis for enhancing the immune effects of vaccines. ConclusionYiqi Zengmian prescription has the effects of replenishing Qi and invigorating spleen, regulating Qi and drying dampness, and enhancing immunity. The in-depth analysis of the TCM theory of Yiqi Zengmian prescription as a vaccine adjuvant and the results of clinical and laboratory studies suggest that Yiqi Zengmian prescription may enhance the induction of immune response after vaccination and maintain the immune memory. However, the mechanism of Yiqi Zengmian prescription in regulating the complex immune network remains to be elucidated.
10.Application of Ancient Books in Clinical Practice Guidelines and Expert Consensus of Traditional Chinese Medicine: Current Status and Methodological Recommendations
Changhao LIANG ; Dingran YIN ; Jing CUI ; Xinshuai YAO ; Xinyi GU ; Yifei YAN ; Wanting LIU ; Yingqiao WANG ; Yingqi CHANG ; Haoyu DONG ; Mengqi LI ; Yuanyuan LI ; Yutong FEI
Journal of Traditional Chinese Medicine 2024;65(8):801-809
ObjectiveTo explore the current status and issues regarding the application of ancient books in clinical practice guidelines and expert consensus of traditional Chinese medicine (TCM) published in China, and to provide methodological recommendations for the incorporation of ancient books in the development of TCM guidelines. MethodsWe searched China National Knowledge Infrastructure (CNKI), WanFang Data, VIP, SinoMed, PubMed, Embase, as well as six industry websites including China Association of Chinese Medicine, National Group Standards Information Platform, and Chinese Association of the Integration of Traditional and Western Medicine,etc. TCM clinical practice guidelines or expert consensus issued during January 1st, 2017, to November 26th, 2022 were searched. Clinical practice guidelines or expert consensus that explicitly referred to ancient books were included, and the content regarding the searching for ancient books, sources of access to ancient books, methods of evaluating the level of evidence, methods of evaluating the level of recommendation, and methods of evaluating the evidence for the ancient books were analysed. ResultsA total of 1,215 TCM clinical practice guidelines or expert consensus were retrieved, with 442 articles explicitly mentioning the application of ancient books, including 300 (67.87%) clinical practice guidelines and 142 (32.13%) expert consensus. Sixty of the 442 publications explicitly reported that ancient books searching had been conducted (13.57%); among these 60 publications 27 (45.00%) explicitly reported ancient books searching strategies, and the most frequent method was manual searching with a total of 24 articles (40.00%). The most popular search source was Chinese Medical Dictionary, a TCM classics database, with a total of 18 articles. 197 articles (44.57%) explicitly reported the evaluation criteria for the level of evidence, of which 141 articles (71.57%) involved the evaluation criteria for the ancient books; 413 articles (93.44%) mentioned ancient books in the recommendations, and only the source of formula name was mentioned in 409 (99.03%) of the publications. ConclusionThe current application of ancient books in TCM clinical practice guidelines and expert consensus is limited, with issues of non-standard searching and evaluation methods. Standar-dization and uniformity are needed in evidence grading and recommendation standards. Future research should clarify the scope and methods of applying ancient book, emphasize their integration with modern research evidence, and enhance their value and quality in the development of TCM clinical practice guidelines.

Result Analysis
Print
Save
E-mail