1.Prevalence and influencing factors of overweight and obesity among primary school students in a community of Fengxian District, Shanghai, 2023
Xinxing ZHANG ; Qing LIU ; Ying WU ; Wanhong HE ; Chunlei PAN
Shanghai Journal of Preventive Medicine 2025;37(8):687-691
ObjectiveTo analyze the prevalence and influencing factors of overweight and obesity among primary school students in a community of Fengxian District, Shanghai, and to provide references for formulating prevention and control strategies against overweight and obesity. MethodsData on height and weight of all primary school students in a community in Fengxian District, Shanghai, in 2023 were obtained by physical examination, and 1 759 primary school students were included according to the entry criteria. Overweight and obesity were determined using body mass index (BMI). Additionally, a questionnaire survey was performed to 1 045 students to collect their demographic characteristics, dietary behaviors, dietary habits, sleep and physical activity information. Chi-square test and logistic regression analysis were used to analyze the influencing factors of overweight and obesity. ResultsIn 2023, among the 1 759 primary school students in the community in Fengxian District, 923 (52.47%) were male and 836 (47.53%) were female, with an overweight/obesity detection rate of 28.08%. The detection rate of overweight and obesity was 33.37% in males and 22.25% in females, which was significantly higher in males than that in females (χ2=26.845, P<0.001). Students aged 10‒12 years had a higher overweight/obesity detection rate (32.55%) than those aged 6‒<10 years (26.53%), and the difference was statistically significant (χ2=10.925, P<0.001). Logistic regression analysis revealed that being female, with young age, parental education level of bachelor’s degree and above, a high global dietary recommendation healthy (GDR-healthy) score, preference for vegetables and sweeter home-cooked meals, and a slow eating speed were negatively correlated with overweight/obesity. Whereas, parental overweight and obesity, binge eating, and a faster eating pace than same-age, same-gender peers may be positively correlated with overweight/obesity. ConclusionThe detection rate of overweight and obesity among primary school students in the community in Fengxian District of Shanghai is higher than the national level. Gender, age, parental BMI, parental education level, dietary behaviors and habits are the main influencing factors of overweight/obesity among primary school students.
2.Risk analysis of astronauts radiation dose induced by solar proton event
Wei LU ; Chang LIU ; Xiaodong ZHANG ; Hongbo MA ; Xinxing HE ; Pengfei ZOU ; Jinxue FEI
Space Medicine & Medical Engineering 2024;35(6):371-374,385
Solar proton event(SPE)is the major concern for astronauts in space radiation environment.With the coming of solar activity peak of the 25th solar cycle,the frequency of occurrence of solar proton event is increasing,as well as the intense of the events.Two SPEs of the most flux in March 23rd,2024 and June 8th,2003 and one with extra-large geomagnetic storm in May 10th,2004 were used to analysis the astronaut dose both in China Space Station orbit and lunar environment.First,radiation particle spectrum outside TianHe module was used to calculate astronauts dose inside the station,which was compared with the measured dose;second,the fitting result of proton spectrum from GOES16 satellite was used to calculate astronaut dose in lunar orbit,which was compared with the dose measured by CRaTER.Besides,the change of dose with extra shield of different material was calculated.The results indicate when no extra-large geomagnetic storm occurs,middle level SPE has no influence to astronaut in station,but an obvious dose increase happens in lunar environment,approaching ten or more mGy in skin.When shielded by Al or water of 10g/cm2,the astronaut's dose could be reduced to mGy or below.Extra energetic protons would observe on station orbit when an SPE with extra-large geomagnetic storm occurs,however when the amount of energetic protons is small,the extra dose is about several 1 nGy to 1 μGy in skin,which was negligible compared with daily dose.When a middle or above level SPE occurs,the influence to astronaut in LEO needs judge immediately,which is mostly based on the geomagnetic activity,but extra shield are needed for manned lunar exploration to ensure astronaut safety.
3.Deformation Characteristics of Hand Movement During Grasping
Qiyu ZHU ; Zixiang TONG ; Fang YUAN ; Kang WEI ; Xinxing SHAO ; Xiaoyuan HE
Journal of Medical Biomechanics 2021;36(3):E423-E439
Objective Based on the multi-camera digital image correlation (DIC) method, the dynamic deformation characteristics of human hand during grasping were studied. Methods A continuous four-camera DIC system was established to measure surface strain of the skin on the back of the hand during grasping process, and then through the connection between skin, joints, bones and muscles, the regular pattern of muscle deformation could be known indirectly. Results Four grasping postures (medium cylinder, lateral pinch, index finger extension, power sphere) were measured. It was found that the increases of strain magnitude were different at different positions on back surface of the hand under different grasping postures, and the maximum principal strains were between 0.1 and 0.3. The movement characteristics for each muscle group of the hand under different grasping postures were obtained through analysis. Conclusions This method has the characteristics of non-contact, full field, intuitive results, which provides a new way for in vivo measurement of dynamic deformation during grasping.
4.Long-term effects of metabolically healthy obesity on the risks of diabetes, cardiovascular disease events and its mortality over 23 years in the China Daqing diabetes prevention study
Xiaojue LI ; Jinping WANG ; Siyao HE ; Xiaoxia SHEN ; Hui WANG ; Xin QIAN ; Xinxing FENG ; Xuan WANG ; Qiuhong GONG ; Yali AN ; Bo ZHANG ; Fang ZHAO ; Hui LI ; Guangwei LI ; Yanyan CHEN
Chinese Journal of Endocrinology and Metabolism 2020;36(3):207-212
Objective:To investigate the long-term effects of metabolically healthy obesity on the risks of type 2 diabetes, cardiovascular disease events, and its mortality over a 23-year follow-up.Methods:Based on the results of an oral glucose tolerance test, there were 519 participants with normal glucose tolerance and 630 with newly diagnosed type 2 diabetes enrolled in 1986 and then given to assess the long-term clinical outcomes during the 23-year follow-up in Daqing. Metabolically healthy obesity was defined as the overweight and obese individuals with no metabolic abnormalities (diabetes, hypertension, hyperlipidemia). Finally, we identified 682 participants (350 with normal glucose tolerance and 332 with newly diagnosed diabetes). They were divided into five groups: 211 individuals with metabolically healthy normal weight (MHNW group), 58 with metabolically healthy overweight and obesity (MHO group), 81, 109, 223 were metabolically unhealthy overweight and obesity with hypertension (MUHO group), type 2 diabetes (MUDO group), hypertension and diabetes (MUHDO group). Incidences of type 2 diabetes, morbidity and mortality of cardiovascular disease were compared among these groups.Results:Over 23 years, instead of the morbidity and mortality of cardiovascular disease, the incidence of type 2 diabetes in MHO group was two times higher than in MHNW group ( 24.1%, 12.5/1 000 person years vs 10.9%, 5.2/1 000 person years, P=0.01), with an age, sex, and smoking history-adjusted hazard ratio ( HR) of 2.42 (95% CI 1.24-4.74, P=0.01). The morbidity and mortality of cardiovascular disease in the groups of overweight and obesity with metabolically unhealthy were higher than in MHNW group, and increased across the subjects with MUHO, MUDO, MUHDO ( P<0.05). Conclusion:Compared with metabolically healthy normal weight participants, the metabolically healthy obese group was at increased risk of type 2 diabetes but not cardiovascular disease events and its mortality. On the contrary, the overweight and obese groups with metabolic abnormalities had significant higher incidence of type 2 diabetes, morbidity and mortality of cardiovascular diseases.
5.Development of methodology for the positioning accuracy of MLC leaves in IMRT
Suming LUO ; Hao WU ; Xian XUE ; Zhijian HE ; Xinxing MA ; Xiaojun CHENG ; Ran LIU ; Chunyong YANG
Chinese Journal of Radiological Medicine and Protection 2019;39(2):121-127
Objective To develop measurement methodology using film for the positioning accuracy of MLC leaves in IMRT.Methods The solid water phantom of 30 cm x 30 cm was scanned and the scanned images were transferred to TPS for treatment plan formulation.The five MLC strip picket fence pattern was formed by MLC leaves,each 3.0 cm long × 6.0 mm wide.The separation between strip and strip is 3.0 cm.SAD is 100 cm at dmax for 6 MV X-ray,with 250 MU per MLC strip.EBT2 radiochomic film was put on the phantom for delivery of IMRT,for each MLC strip.The present study focused on 30 accelerators of Varian,Elekta and Siemens designs at 27 hospitals with highly skilled physicists all over Jiangsu,Sichuan,Hubei and Henan provinces.The study was conducted in the same way as used in international multi-radiotherapy center (IMRC).The irradiated films were sent respectively to IAEA dosimetry laboratory and external audit group (EGA) of China for measurement,analysis and calculation.Results According to IAEA requirements,the differenc of film-measured and TPS-planned of MLC leaf position for each strip should be within ±0.5 mm.China had participated in the research of IMRC,with the result of 0.3,0.2,0.0,-0.1,and-0.2 mm,respectively.For 30 accelerators in four provinces involved in the study,the IAEA's verification results of MLC leaf position were within 0.6-1.0 mm for 5 accelerators and within ± 0.5 mm for other 25 ones.Whereas the verification results of EAG were within 0.6-1.0 mm for 6 accelerators and within ±0.5 mm for other 24 ones.According to IAEA requirements,the film-measured MLC leaf position deviation for each pair of leaves and average all pairs of leaves should be within ±0.5 mm.China had participated in IMRC's research,with the measured result being 0.04 mm.The verification result of EGA for 30 accelerators showed the measured MLC leaf position deviations were all <0.3 mm per strip,consistent with IAEA requirements.The IAEA's result showed the measured deviations of MLC leaf position for 29 accelerators were within ±0.5 mm,with only other one being-0.7 mm not consistent with the IAEA requirements.As required by IAEA,the difference of film-measured difference of MLC opening width should be within ±0.75 mm between each pair and average all pairs of leaves.China's result in research of IMRC showed the difference of minimum width to mean width was-0.2 mm whereas the difference of maximum width to mean width was 0.4 mm.For 30 accelerators involved in IAEA'verification study,the measured result shown that the difference between maximum and average of filmmeasured of MLC leaf width,and between minmum and average,were within ± 0.75 mm for 24 accelerators,in line with the IAEA requirements.For other 6 ones,the values were beyond ±0.75 mm,not in line with the IAEA requirements.For the verification result of EAG,the difference between maximum and average widths and between minmum and average widths for 25 accelerators were within ±0.75 mm as required by IAEA,whereas for other 5 ones the value were beyond ±0.75 mm,not consistent with IAEA requirements.The standard deviation of film-measured MLC opening width between each pair and average all pairs should be within 0.3 mm as required by IAEA.China's IMRC result was 0.12 mm.The verification result of IAEA shown the standard deviation of MLC opening position were <0.3 mm for 26 accelerators and > 0.3 mm for other 4 accelerators.EAG verification result were the same as IAEA result.Conclusions The method using radiochromic film for measuring accuracy of MLC leaf position is convenient and practicable as a quality audit.It is suitable for quality verification in medical institutions owing to easy to post and repeated measurements.
6.Association between polymorphism of TGF-β1 gene and type 2 diabetes mellitus in Chinese Han population in Shanghai
Junyan LI ; Feng TAO ; Xinxing WU ; Yingzi TAN ; Lin HE ; Hao LU
The Journal of Practical Medicine 2015;(18):3078-3080
Objective To study the association between transforming growth factor-β1 (TGF-β1) polymorphism and type 2 diabetes mellitus in Han population of Shanghai. Methods In this case-control study , 1 234 cases of T2DM patients were recruited and 1 272 healthy individuals were selected as control. Five ml of blood sample was collected from each subject ,from which the whole genomic DNA was extracted.The polymorphism was detected by the Taqman technology. Result Significant association was observed in TGF-β1 T896C genotypes and alleles with T2DM (P = 0.0001 and P = 0.004, OR = 1.18 [1.05 ~ 1.33], respectively). Conclusion The polymorphism of T896C in TGF-β1 gene may be associated with T2DM in Han population from Shanghai.
7.Verification of dosimetric methodology for auditing radiotherapy quality under non-reference condition in Hubei province
Xinxing MA ; Suming LUO ; Zhijian HE ; Wenshan ZHOU
Chinese Journal of Radiological Medicine and Protection 2014;34(6):461-465
Objective To verify the reliability of TLD-based quality audit for radiotherapy dosimetry of medical electron accelerator in non-reference condition by monitoring the dose variations from electron beams with different field sizes and 45° wedge and the dose variations from photon beams with different field sizes and source-skin distance.Methods Both TLDs and finger ionization chambers were placed at a depth of 10 cm in water to measure the absorbed dose from photon beams,and also placed at the depth of maximum dose from electron beams under non-reference condition.TLDs were then mailed to National Institute for Radiological Protection,China CDC for further measurement.Results Among the 70 measuring points for photon beams,58 points showed the results with a relative error less than ± 7.0% (IAEA's acceptable deviation:± 7.0%) between TLDs and finger ionization chambers measurements,and the percentage of qualified point numbers was 82.8%.After corrected by P,value,62 points were qualified and the percentage was up to 88.6%.All of the measuring points for electron beams,with the total number of 24,presented a relative error within ± 5.0% (IAEA's acceptable deviation:± 5.0%) between TLDs and finger ioization cylindrical chambers measurements.Conclusions TLD-based quality audit is convenient for determining radiotherapy dosimetric parameters of electron beams in non-reference condition and can improve the accuracy of the measuring parameters in connection with finger chambers.For electron beams of 5 MeV < E0 < 10 MeV,the absorbed dose parameters measured by finger ionization chambers,combined with TLD audit,can help obtain the precise and reliable results.
8.Effects of Drynaria total flavonoids on apoptosis of osteoblasts mediated by tumor necrosis factor-α.
Zhiming HUANG ; Guiling OUYANG ; Lianbao XIAO ; Ningli LI ; Huali GAO ; Yong HE ; Zheng HUANG ; Xinxing HUANG
Journal of Integrative Medicine 2011;9(2):173-8
To investigate the influence of Drynaria total flavonoids on proliferation and apoptosis of osteoblasts in tumor necrosis factor-α (TNF-α)- mediated medium, so as to explore the mechanism of Drynaria total flavonoids in preventing and treating osteoporosis of rheumatoid arthritis.

Result Analysis
Print
Save
E-mail