1.Effect of 17β-estradiol on cognitive memory during the reconsolidation period of fear memory in model rats with posttraumatic stress disorder
Han WANG ; Qiaoying ZUO ; Xinqi YU ; Lin SUN ; Ling WANG ; Hongwei SUN
Chinese Journal of Behavioral Medicine and Brain Science 2023;32(12):1064-1070
Objective:To explore the role of 17β-estradiol(17β-E2) derived from the hippocampus and gonad in the cognitive memory during the reconsolidation period of fear memory in rats with post-traumatic stress disorder(PTSD).Methods:The 8-week-old clean grade female SD rats were used for this study. Single prolonged stress combined with context fear conditioning was used to prepare the rat PTSD model.(1) Gonad estradiol experiment: 50 female rats were randomly divided into blank control group, model group, sham ovariectomy group, ovariectomy group, and ovariectomy+ estradiol group by random number table method, with 10 rats in each group. The rats in model group, sham ovariectomy group, ovariectomy group, and ovariectomy+ estradiol group were established PTSD model. Rats in ovariectomy group and ovariectomy+ estradiol group underwent ovariectomy, while rats in sham ovariectomy group only were removed adipose tissue of the same mass around the ovaries. And the rats in ovariectomy+ estradiol group were injected with 17β-E2(1 mg/kg, once a day for 14 days) 7 days after ovariectomy.(2) Hippocampal estradiol experiment: 40 female rats were randomly divided into blank control group, model group, hippocampal solvent control group and hippocampal estradiol inhibitor group by random number table method, with 10 rats in each group.The rats in model group, hippocampal solvent control group and hippocampal estradiol inhibitor group were established PTSD model.Rats in hippocampal estradiol inhibitor group were given letrozole once(bilateral, 0.5 μL per side) during the fear memory consolidation period) and rats in the hippocampus solvent control group were injected once with dimethyl sulfoxide in the hippocampus(bilateral, 0.5 μL per side) . The open field test and elevated cross maze test were used to evaluate the anxiety level and autonomous exploration ability, the freeze test was used to evaluate the fear memory, the new object recognition test was used to evaluate the non-spatial memory, and ELISA was used to detect serum 17β-E2 level. SPSS 25.0 software was used for data analysis, and one-way ANOVA was used for inter group comparisons, LSD test was used for further pairwise comparisons.Results:(1)In the gonad estradiol experiment, there were statistical differences in various indicators among the five groups of rats in the open field test, elevated cross maze test, freeze test, and new object recognition test( F=20.200, 12.702, 7.514, 10.094, 7.899, 13.211, all P<0.05). The number of upright times, central area activity time, distance and frequency of entering the open arm, and cognitive index of the model group rats were all lower than those of the blank control group(all P<0.05), and the freezing time was higher than that of the blank control group( P<0.05). The number of upright positions((11.20±1.55) times), central area activity time((11.33±1.80) s), distance((1.49±0.26) m) and times((10.00±1.50) times) entering the open arm, the freezing time((92.20±6.07) s) and cognitive index((60.40±3.71)%) in ovariectomy+ estradiol group were all higher than those of ovariectomy group((4.90±0.65) times, (4.31±1.07) s, (0.49±0.06) m, (3.10±0.62) times, (60.30±5.28) s, (32.60±8.08)%)(all P<0.05). (2) In the hippocampal estradiol experiment, there were statistical differences in various indicators among the four groups in the open field test, elevated cross maze test, freeze test, and new object recognition test( F=40.831, 5.553, 9.087, 5.848, 7.657, 9.191, all P<0.05). The numbers of upright positions, distance and frequency of entering open arms of the model group rats were lower than those of the blank control group(all P<0.05). The number of upright positions((3.00 ± 0.39) times), distance of entering open arm((1.17±0.37) m), freezing time((46.70±3.57)s), and cognition index((29.60±2.70)%) in the hippocampal estradiol inhibitor group were all lower than those in the hippocampal solvent control group((10.10±1.40) times, (4.02±0.79) m, (93.70±9.73) s, (54.20±5.08)%)(all P<0.05). Conclusion:17β-E2 derived from the hippocampus and gonad both had ameliorative effect on cognitive memory and anxiety-like behavior in the reconsolidation period of fear memory in PTSD model rats.
2.Design and Clinical Application of Split Memory Alloy Sternum Plate.
Yanzhong LIU ; Xinqi HAN ; Lixia SONG ; Cheng WANG ; Yong SHI ; Xiangwen MIAO ; Yan TANG ; Chenglong YUAN ; Jingyuan LI ; Yuehui MA
Chinese Journal of Medical Instrumentation 2021;45(3):288-291
OBJECTIVE:
The design and development of split memory alloy sternum bone plate are discussed, and the effect of split memory alloy sternum bone plate internal fixation in the treatment of sternal fractures are analysed.
METHODS:
The structure of the product is designed according to the anatomy and physiological characteristics of human bones, and the cross section shape of the product is designed according to the cross section shape of human bones. Internal fixation is effective in the treatment of sternal fracture.
RESULTS:
The split memory alloy sternal plate was successfully designed and developed, and all the patients with sternal fractures treated by internal fixation were clinically healed, the hospitalization and fracture healing time were significantly shortened, and no obvious complications occurred.
CONCLUSIONS
The application of split memory alloy sternal plate internal fixation in the treatment of sternal fracture has the advantages of small trauma, simple operation, safety, reliable fixation, good histocompatibility and less complications, and is conducive to promoting fracture healing and respiratory function improvement.
Alloys
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Healing
;
Humans
;
Sternum/surgery*
3.A clinical study of preoperative endoscopic assessment of the invasion depth of colorectal laterally spreading tumor
Xinqi CHEN ; Jianqun CAI ; Jie FENG ; Wei GONG ; Qiang ZHANG ; Wei ZHU ; Wen GUO ; Zelong HAN ; Yali ZHANG ; Baoping WU
Chinese Journal of Digestive Endoscopy 2019;36(7):474-478
Objective To compare the diagnostic accuracy of magnifying chromoendoscopy (MCE) and endoscopic ultrasonography (EUS) for preoperative endoscopic assessment of the invasion depth of colorectal laterally spreading tumour(LST).Methods Data of 104 cases of colorectal LST were included.With the final pathological diagnosis as the golden standard,the accuracies of MCE and EUS for preoperative assessment of the invasion depth of colorectal LST were compared.Results The diagnostic accuracies of MCE and EUS for evaluating the invasion depth of LST were 89.4% (93/104) and 73.1% (76/104),respectively(P<0.05).The lesion size and the endoscopist could affect the accuracy of the EUS evaluation (P=0.017,OR=3.561;P=0.035,OR =1.399).The accuracy of EUS seemed to show a downward trend for colorectal LST of larger diameters.Conclusion Both MCE and EUS are effective for evaluating the invasion depth of colorectal LST,but the accuracy of MCE may be higher than that of EUS.Large diameter of the lesion and the doctor's experience inadequacy may be the risk factors for the accuracy of EUS.
4. The investigation of the positive rate of intrinsic factor antibody and deficiency rate of vitamin B12 in normal physical examination population
Xuehui GAO ; Quexuan CUI ; Qiangxing ZHANG ; Xinqi CHENG ; Jun LU ; Ling QIU ; Bing HAN
Chinese Journal of Hematology 2018;39(11):917-920
Objective:
To explore the positive rate of intrinsic factor antibody (IFAb) and level of vitamin B12 (VitB12) in normal physical examination population and the possible relation between IFAb, VitB12 and sex, age, number of RBC, HGB and MCV.
Methods:
A total of 1 427 people who came to Peking Union Medical Colleague Hospital (PUMCH) for physical examination were enrolled. There were 758 males with average age of (52.5±14.5) years-old and 669 females with average age of (50.3±14.3) year-old. Beckman DxI800 automatic biochemical-immune analyzer and corollary reagents were used to analyze the level of serum IFAb and VitB12. The results in different sex, age were documented and their correlation with the value of whole blood cell count was tested later on.
Results:
Among the 1 427 normal subjects, 66 (4.63%) were positive for IFAb. The positive rate for IFAb in the population≥40 years-old was higher than those<40 years-old (5.66%
5.Survey of vitamin D status in apparently healthy younger and elder adults
Ruiping ZHANG ; Songlin YU ; Xinqi CHENG ; Liangyu XIA ; Qian CHENG ; Jianhua HAN ; Xuzhen QIN ; Pengchang LI ; Li'an HOU ; Ling QIU
Chinese Journal of Laboratory Medicine 2017;40(9):689-692
Objective To analyze the vitamin D status among apparently healthy younger and elder adults in Beijing based on liquid chromatography tandem mass spectrometry.Methods This is an observational study.Participants included 287 apparently healthy young adults(143 males and 144 females) with an average of (32.2 ± 6.9) years old (19-44 years).At the same time 198 middle-and elder-aged adults were recruited [90 males,108 females,(55.6 ± 7.6) years],and fasting blood samples were collected and serum were isolated.They measured 25-hydroxyvitamin D (25OHD:25OHD2 and 25OHD3)using liquid chromatography tandem mass spectrometry method.Vitamin D with deficiency,insufficiency,sufficiency and intoxication was categorized as 25OHD < 20 ng/ml,20-30 ng/ml,30-150 ng/ml,and ≥ 150 ng/ml,respectively.ALT,Ca,P,Cr,Glu,TG,TC and iPTH wereanalyzed using automatic analyzers.Statistical analysis was performed using SPSS17.0.Results The median 25OHD level in the total studied younger adults was 16.0 [2.5%-97.5%:(6.1-29.0) ng/ml] which didn't show significant difference with that of middle-and elder-aged adults.Younger males had significant higher level of 25OHD than females [17.9 (8.3-32.3) ng/ml vs.14.4 (5.4-26.4) ng/ml,Z =-4.238,P < 0.01].Of the total younger subjects,the rate of vitamin D with deficiency (< 20 ng/ml),insufficiency (20-30 ng/ml)and sufficiency (≥30 ng/ml) was 72.8%,25.1%,2.1%,respectively,while that of middle-and elderaged adults was 76.3%,21.2%,2.5% respectively,and that of younger males was 65.0%,30.8%,4.2%,respectively while that of younger females was 80.6%,19.4%,0%,respectively.Younger females had significantly higher rate of 25OHD deficiency (x2 =31.766,P < 0.01).With adjusting sex,age and BMI,serum iPTH (r =-0.264,P < 0.01) was significantly negatively correlated with 25OHD while Cr (r =0.221,P < 0.01) showed significantly positively correlation with 25OHD.Conclusion Vitamin D deficiency is prevalent in both younger and elder adults in Beijing,especially in younger females.
6.CLE42 binding induces PXL2 interaction with SERK2.
Shulin MOU ; Xiaoxiao ZHANG ; Zhifu HAN ; Jiawei WANG ; Xinqi GONG ; Jijie CHAI
Protein & Cell 2017;8(8):612-617
Arabidopsis
;
chemistry
;
genetics
;
metabolism
;
Arabidopsis Proteins
;
chemistry
;
genetics
;
metabolism
;
Crystallography, X-Ray
;
Intercellular Signaling Peptides and Proteins
;
chemistry
;
genetics
;
metabolism
;
Protein Conformation
;
Protein-Serine-Threonine Kinases
;
chemistry
;
genetics
;
metabolism
7.Quantification of human urine and serum iodine by inductively coupled plasma mass spectrometry
Songlin YU ; Qian CHENG ; Jianhua HAN ; Weiyan ZHOU ; Xinqi CHENG ; Li′an HOU ; Ran GAO ; Wei SU ; Zhi LI ; Ling QIU
Chinese Journal of Laboratory Medicine 2016;39(12):917-921
Objective This paper aims at establishing a inductively coupled plasma mass spectrometry ( ICP-MS) method for quantification and evaluation of iodine in human urine and serum in routine clinical laboratory .Methods This study was methodology validation research on iodine evaluation using ICP-MS.Ammonia, isopropanol and ultrapure water were mixed at certain ratio to dilute samples in the ratio of 1:10, and then the diluted samples were analyzed by ICP -MS.Re was used as the internal standard.And linearity, lower limit of detection, recovery, precision, accuracy, carryover and stability was evaluated thoroughly .Results of iodine of pregnant women who required iodine tests were retrospectively analyzed to evaluate the status of iodine .Results The method only needs 30s for analysis of one sample .It was sensitive with a lower limit detection of 0.87μg/L, the correlation coefficient was higher than 0.999 9 in ten measurements.The recovery in both serum and urine was approximately 100% (95.3% -109.9%). Based on the NIST standard reference material 3668 comparison, the bias was less than 4%( -0.9% -3.9%).The inter-coefficient variation (CV) for serum iodine and urine iodine was 1.2%-3.0%, 2. 0%-2.9%, respectively;and total CV for serum iodine and urine iodine were 3.0%-3.8%, 4.1%-4.9%, respectively.The mean carryover of this method was 0.03% and iodine was stable for at least one month at -20℃ and 4℃.The urine and serum iodine for pregnant women was (154.8 ±89.7) μg/L (mean ±SD),(75.8 ±21.4) μg/L, respectively.The correlation between urine and serum iodine was 0.21. Conclusion Establishe a rapid and simple ICP -MS method for urine and serum iodine measurement with high accurate and precise in routine clinical laboratory .
8.Comparison of five automated 25OHD immunoassays and liquid chromatography tandem mass spectrometry method
Songlin YU ; Huiling FANG ; Xinqi CHENG ; Ruiping ZHANG ; Jianhua HAN ; Xuzhen QIN ; Liangyu XIA ; Wei SU ; Qian CHEN ; Ling QIU
Chinese Journal of Laboratory Medicine 2015;(7):475-479
Objective To compare the concordance of five automated 25OHD immunoassays with liquid chromatography tandem mass spectrometry method ( LC-MS/MS) .Methods During May to July in 2014, 245 clinical serum samples that requested 25OHD tests were selected, with a total 25OHD range of 2.8 ng/ml-64.0 ng/ml, in which 154 samples did not contain 25OHD2 and 91 samples contains both 25OHD2 and 25OHD3 .To used a LC-MS/MS method that built in our laboratory to measure 25OHD, five commercial automated chemiluminescent immunoassays from Abbott Diagnostics ( A ) , DiaSorin LIASON (B), IDS-iSYS(C), Roche Diagnostics(D), and Siemens ADVIA Centaur(E).Taking the reference method LC-MS/MS as a standard , to compared the concordance and performance of the five automated 25OHD immunoassays.And used the commonly accepted cutoffs for 25OHDdeficiency (<20 ng/ml), and insufficiency ( 20 -30 ng/ml ) , and sufficiency (≥30 ng/ml ) to compare the uniformity of different methods .Statistical analysiswere performed by MedCalc software , Passing & Bablok regression , Bland &Altaman plots and Box and whisker plots were performed to compare the differences of the methods .Results The medium ( range:2.5% -97.5%) 25OHD of the 245 serum samples of the six methods was 23.5 (5.8-44.2) ng/ml(LC-MS/MS),20.6 (7.1-43.5)ng/ml(A),19.0 (5.4-38.0) ng/mL (B),23.0 (10.0-38.1) ng/ml(C),20.1 (5.1 -46.0) ng/ml (D),31.3 (12.3 -71.1) ng/ml (E), respectively .Passing and Bablok regression showed that method B had the best correlation coefficient with LC-MS/MS (r=0.894), while methods A, C and D had relatively small bias compared withLC-MS/MS and method E had the large bias .If the serum samples did not contain 25OHD2 , all the five automated immunoassays correlated well with LC-MS/MS with a correlation coefficient higher than 0.84, and B has the best correlation with LC-MS/MS ( r=0.930 ) .While all the correlation coefficient between immunoassays and LC-MS/MS decreasedwhen analyzing the samplescontaining 25OHD2.Using the clinical cutoffs, A, B, C, D and E had a concordance of 68.6%, 64.9%, 67.8%, 70.6% and 51.8% compared with LC-MS/MS, respectively .Conclusions There are significant differences between different detection systems of 25OHD.All the immunoassays results were affected by the existence of 25OHD2 .The concordance of serum 25OHD resultswas poor between different methods , and it may be necessary to built exclusive cutoffs for different methods.
9.Reference intervals of serum calcium, phosphate and alkaline phosphatase of healthy school children and adolescents in Heilongjiang province
Xinqi CHENG ; Qian CHENG ; Ling QIU ; Li LIU ; Qian LIU ; Shaomei HAN ; Guangjin ZHU
Basic & Clinical Medicine 2015;(9):1205-1208
Objective To analyze the serum calcium , phosphate and alkaline phosphatase level among apparently healthy school children and adolescents in Heilongjiang Province and establish the reference intervals in different gender and different age groups .Methods Random sample of 2 101 primary and secondary school students from 9 to 18-year-old was collected from different district of Heilongjiang Province including Harbin and Mudanjiang from July 2008 to June 2009 .The fasting venous blood was collected and serum calcium , phosphate and alkaline phos-phatase concentration was measured as soon as possible .After screening outlier individual , a total of 2 091 subjects were enrolled.The reference intervals of serum calcium , phosphate and alkaline phosphatase for healthy school children and adolescents were established by gender and age ( P2.5 to P97.5 ) .Results The change tendency of serum calcium, phosphate and alkaline phosphatase with age and sex were presented .All these parameters had shown inverse relationship with age and were significantly higher in boys than girls (P<0.001).Serum calcium, phosphate of both sexes and serum alkaline phosphatase of girls declined progressively with age .However , the highest alkaline phosphatase level was seen at 13 years in boys.Alkaline phosphatase showed a positive correlation with age before 13 years of age , but after that alkaline phosphatase started to decline .Conclusions Reference in-tervals of serum calcium , phosphate and alkaline phosphatase for healthy school children and adolescents in Hei -longjiang Province in the age group of 9-18 years were presented , which supply good reference value for clinicians especially pediatricians to interpret the results of school children and adolescents and make decision .
10.Evaluation of interference of thyroglobulin antibodies on the measurement of thyroglobulin by two chemiluminescence immunoassay
Xinqi CHENG ; Cheng JIN ; Song HAN ; Kui ZHANG ; Huaicheng LIU ; Shaowei XIE ; Yingying HU ; Qinyong WU ; Shuangyu LU ; Guohua YANG ; Dianxi ZHANG ; Ling QIU
Chinese Journal of Laboratory Medicine 2015;(10):701-704
Objective To investigate the interference of thyroglobulin antibodies ( TgAb ) on the measurement of thyroglobulin ( Tg) by 2 chemiluminescence immunoassays ( CLIAs) .Methods Data of 199 315 individuals with determined TgAb and Tg , including physical checkup subjects , differentiated thyroid carcinoma ( DTC) patients and patients with other diseases , were retrospectively collected in Peking Union Medical College Hospital from November 2012 to April 2015.The correlation between serum Tg level and serum TgAb concentration was analyzed and the positive rate of TgAb in physical checkup subjects was calculated.Furthermore, 290 serum samples with different TgAb concentration were applied in the recovery test by adding in confirmed serum Tg .The correlation between the recovery of confirmed serum Tg and TgAb concentrations was evaluated using Pearson correlation analysis .Results The serum Tg was all decreased with the elevated TgAb concentration in each group of subjects .The positive rate of TgAb was 10.84%(8 416/77 634) in physical checkup subjects .It was higher in females than in males and was increased with age.Recovery test showed that the average recoveries of confirmed serum Tg in TgAb-negative serum were 107.28%(86.30%-117.60%) and 107.94% (85.60%-124.10%) respectively in Roche and Beckman systems.But in TgAb-positive serum samples , the average recoveries in Roche and Beckman systems were 88.59% (35.85% -141.53%) and 95.77% (36.48% -131.78%) respectively, and 12.63%(24/190) and 13.68%(26/190) samples displayed a recovery less than 80%.The recovery rate of confirmed serum Tg showed a significantly negative correlation with elevated TgAb concentration , with r=-0.239 (P=0.001) in Roche and r=-0.251 (P<0.001) in Beckman.Conclusions TgAb-positive serum, especially with high concentration of TgAb , significantly interfered the measurement of Tg .Thus, serum TgAb should be determined together with serum Tg to explore whether there was an interference .To avoid misdiagnosis and inappropriate therapy , clinician should be informed once serum TgAb displayed positive.

Result Analysis
Print
Save
E-mail