1.Preliminary clinical study of a novel FAP-targeted PET tracer 64Cu-FAPI-XT117 in malignant solid tumors: a comparative study with 18F-FDG
Xi HE ; Meijuan ZHOU ; Peng HOU ; Kaixiang ZHONG ; Youcai LI ; Jie LYU ; Miao KE ; Ruiyue ZHAO ; Shaoyu LIU ; Yimin FU ; Huizhen ZHONG ; Xinlu WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(12):708-713
Objective:To systematically evaluate the safety and efficacy of the novel fibroblast activation protein (FAP)-targeted tracer 64Cu-FAP inhibitor (FAPI)-XT117 in patients with malignant solid tumors, and to compare with 18F-FDG. Methods:This self-controlled study was conducted on fifteen patients (8 males, 7 females; age (60 ±9) years) with malignant solid tumors from the First Affiliated Hospital of Guangzhou Medical University between July 2023 and December 2023. Each subject underwent 64Cu-FAPI-XT117 PET/CT at 30, 60, and 120min post-injection and was assigned to three dose cohorts (111MBq, 148MBq, and 185MBq; 5 patients in each cohort), and safety assessments were conducted within 24h after injection. In addition, all patients underwent 18F-FDG PET/CT at 60min post-injection. Time-activity curves were generated for 64Cu-FAPI-XT117, and the dosimetry was calculated. Image quality was evaluated using a 5-point Likert scale, and the optimal injected activity and imaging time point were determined. The paired t test was used to compare differences of the lesion detection count and SUV max between 64Cu-FAPI-XT117 and 18F-FDG PET/CT. Results:64Cu-FAPI-XT117 was well tolerated, with no adverse events reported. Time-activity curves of 68Ga-FAPI-XT117 revealed prominent uptake in the uterus, while the background activity in other organs remained low, with the whole-body effective dose of (0.0084±0.0021)mSv/MBq. The optimal imaging time point for 64Cu-FAPI-XT117 PET/CT was 60min post-injection, with an optimal administered activity of 111MBq. Compared with 18F-FDG, 64Cu-FAPI-XT117 demonstrated significantly higher uptake and more lesions in lymph-node metastases (SUV max: 8.6±3.8 vs 15.3±6.8, t=2.33, P=0.048; number of lesions: 8.3±5.4 vs 15.0±6.4; t=4.21, P=0.003) and distant metastases (SUV max: 11.8±3.7 vs 20.9±7.2, t=3.66, P=0.022; number of lesions: 7.0±3.2 vs 12.4±3.7, t=2.86, P=0.046). Conclusions:64Cu-FAPI-XT117 PET/CT is well tolerated in patients with solid tumors, with a controllable radiation risk. Moreover, it outperforms 18F-FDG PET/CT in the assessment of metastases.
2.Preliminary clinical study of a novel FAP-targeted PET tracer 64Cu-FAPI-XT117 in malignant solid tumors: a comparative study with 18F-FDG
Xi HE ; Meijuan ZHOU ; Peng HOU ; Kaixiang ZHONG ; Youcai LI ; Jie LYU ; Miao KE ; Ruiyue ZHAO ; Shaoyu LIU ; Yimin FU ; Huizhen ZHONG ; Xinlu WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(12):708-713
Objective:To systematically evaluate the safety and efficacy of the novel fibroblast activation protein (FAP)-targeted tracer 64Cu-FAP inhibitor (FAPI)-XT117 in patients with malignant solid tumors, and to compare with 18F-FDG. Methods:This self-controlled study was conducted on fifteen patients (8 males, 7 females; age (60 ±9) years) with malignant solid tumors from the First Affiliated Hospital of Guangzhou Medical University between July 2023 and December 2023. Each subject underwent 64Cu-FAPI-XT117 PET/CT at 30, 60, and 120min post-injection and was assigned to three dose cohorts (111MBq, 148MBq, and 185MBq; 5 patients in each cohort), and safety assessments were conducted within 24h after injection. In addition, all patients underwent 18F-FDG PET/CT at 60min post-injection. Time-activity curves were generated for 64Cu-FAPI-XT117, and the dosimetry was calculated. Image quality was evaluated using a 5-point Likert scale, and the optimal injected activity and imaging time point were determined. The paired t test was used to compare differences of the lesion detection count and SUV max between 64Cu-FAPI-XT117 and 18F-FDG PET/CT. Results:64Cu-FAPI-XT117 was well tolerated, with no adverse events reported. Time-activity curves of 68Ga-FAPI-XT117 revealed prominent uptake in the uterus, while the background activity in other organs remained low, with the whole-body effective dose of (0.0084±0.0021)mSv/MBq. The optimal imaging time point for 64Cu-FAPI-XT117 PET/CT was 60min post-injection, with an optimal administered activity of 111MBq. Compared with 18F-FDG, 64Cu-FAPI-XT117 demonstrated significantly higher uptake and more lesions in lymph-node metastases (SUV max: 8.6±3.8 vs 15.3±6.8, t=2.33, P=0.048; number of lesions: 8.3±5.4 vs 15.0±6.4; t=4.21, P=0.003) and distant metastases (SUV max: 11.8±3.7 vs 20.9±7.2, t=3.66, P=0.022; number of lesions: 7.0±3.2 vs 12.4±3.7, t=2.86, P=0.046). Conclusions:64Cu-FAPI-XT117 PET/CT is well tolerated in patients with solid tumors, with a controllable radiation risk. Moreover, it outperforms 18F-FDG PET/CT in the assessment of metastases.
3.Design of automatic reverse osmosis water system
China Medical Equipment 2015;(2):53-55,56
Objective:To design automatic reverse osmosis water system with new design idea of reverse osmosis water system, to make sure of the procedure. Methods:During the design, using microcomputer technology to control water preparation and disinfection. Results:Using MCU to control preparation of water and disinfection, in order to monitor water quality. If water quality exceeds the standard, the system will alarm and generate records. Conclusion: Using microcomputer technology to design Reverse osmosis water system, not only reducing artificial, but also to improve the safety and controllability, even the quality control of reverse osmosis water system.
4.Responsibility transformation of hemodialysis engineer
China Medical Equipment 2015;(5):112-113
Objective:To investigate the responsibility transformation of hemodialysis engineer with the popularization of hemodialysis therapy. Methods:Through long clinical practice and exploration the responsibility of hemodialysis engineer in the new environment by working closely with senior engineer and nurse which leaded the cooperation between manufacturers and department of equipment in hospital. Results: According to the discussion and practice demonstration, the responsibility of hemodialysis engineer is no longer corrective maintenance, but to put more attention to preventive maintenance and quality control, even to improvement maintenance to service clinical. Conclusion:With the quality improvement and new idea which the management model focuses on patients, hemodialysis engineer will strengthen the quarlity control and improve the maintenance, provide better service for clinical work.
5.Optimization of Toxicity Attenuation Processing Technology of Amorphophallus sinensis Belval. by Orthogo-nal Test
Xinlu MEI ; Bin XU ; Feila XU ; Shuhua TONG ; Sanmin HE
China Pharmacy 2015;(22):3137-3139
OBJECTIVE:To optimize the toxicity attenuation processing technology of Amorphophallus sinensis Belval.. METH-ODS:With the overall score of taste stimulation and rabbit eye irritation of A. sinensis Belval. as the index,and based on the sin-gle factor method,orthogonal test was designed to investigate the the influences of the amount of saturated calcium hydroxide solu-tion,heating time and heating temperature on the processing effect,and verification tests as well as irratation comparison before and after processing were conducted. RESULTS:The amount of saturated calcium hydroxide solution and heating temperature had significant influence on the processing effect. The optimal processing technology was to add saturated calcium hydroxide solution 30 times as much as the amount of medicinal materials at 100 ℃ and heat it for 30 min. The verification tests showed overall scores of 8.05,8.44 and 8.37(RSD=2.5%,n=3). The average overall scores before and after processing were 0.12 and 8.54(n=10)re-spectively. CONCLUSIONS:The medicinal materials processed by the optimal technology have lower stimulation and irritation. The optimal technology is stable and reliable.

Result Analysis
Print
Save
E-mail