1.Cost-effectiveness of angiographic quantitative flow ratio-guided coronary intervention: A multicenter, randomized, sham-controlled trial.
Yanyan ZHAO ; Changdong GUAN ; Yang WANG ; Zening JIN ; Bo YU ; Guosheng FU ; Yundai CHEN ; Lijun GUO ; Xinkai QU ; Yaojun ZHANG ; Kefei DOU ; Yongjian WU ; Weixian YANG ; Shengxian TU ; Javier ESCANED ; William F FEARON ; Shubin QIAO ; David J COHEN ; Harlan M KRUMHOLZ ; Bo XU ; Lei SONG
Chinese Medical Journal 2025;138(10):1186-1193
BACKGROUND:
The FAVOR (Comparison of Quantitative Flow Ratio Guided and Angiography Guided Percutaneous Intervention in Patients with Coronary Artery Disease) III China trial demonstrated that percutaneous coronary intervention (PCI) lesion selection using quantitative flow ratio (QFR) measurement, a novel angiography-based approach for estimating fractional flow reserve, improved two-year clinical outcomes compared with standard angiography guidance. This study aimed to assess the cost-effectiveness of QFR-guided PCI from the perspective of the current Chinese healthcare system.
METHODS:
This study is a pre-specified analysis of the FAVOR III China trial, which included 3825 patients randomized between December 25, 2018, and January 19, 2020, from 26 centers in China. Patients with stable or unstable angina pectoris or those ≥72 hours post-myocardial infarction who had at least one lesion with a diameter stenosis between 50% and 90% in a coronary artery with a ≥2.5 mm reference vessel diameter by visual assessment were randomized to a QFR-guided strategy or an angiography-guided strategy with 1:1 ratio. During the two-year follow-up, data were collected on clinical outcomes, quality-adjusted life-years (QALYs), estimated costs of index procedure hospitalization, outpatient cardiovascular medication use, and rehospitalization due to major adverse cardiac and cerebrovascular events (MACCE). The primary analysis calculated the incremental cost-effectiveness ratio (ICER) as the cost per MACCE avoided. An ICER of ¥10,000/MACCE event avoided was considered economically attractive in China.
RESULTS:
At two years, the QFR-guided group demonstrated a reduced rate of MACCE compared to the angiography-guided group (10.8% vs . 14.7%, P <0.01). Total two-year costs were similar between the groups (¥50,803 ± 21,121 vs . ¥50,685 ± 23,495, P = 0.87). The ICER for the QFR-guided strategy was ¥3055 per MACCE avoided, and the probability of QFR being economically attractive was 64% at a willingness-to-pay threshold of ¥10,000/MACCE avoided. Sensitivity analysis showed that QFR-guided PCI would become cost-saving if the cost of QFR were below ¥3682 (current cost: ¥3800). Cost-utility analysis yielded an ICER of ¥56,163 per QALY gained, with a 53% probability of being cost-effective at a willingness-to-pay threshold of ¥85,000 per QALY gained.
CONCLUSION:
In patients undergoing PCI, a QFR-guided strategy appears economically attractive compared to angiographic guidance from the perspective of the Chinese healthcare system.
TRIAL REGISTRATION
ClinicalTrials.gov , NCT03656848.
Humans
;
Cost-Benefit Analysis
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Angiography/methods*
;
Middle Aged
;
Aged
;
Coronary Artery Disease/surgery*
;
Quality-Adjusted Life Years
;
Fractional Flow Reserve, Myocardial/physiology*
2.Evaluation of the accuracy of three-dimensional data acquisition from liquid- interference surfaces assisted by a scanner head with a compressed airflow system.
Xinkai XU ; Jianjiang ZHAO ; Sukun TIAN ; Zhongning LIU ; Xiaoyi ZHAO ; Xiaobo ZHAO ; Tengfei JIANG ; Xiaojun CHEN ; Chao MA ; Yuchun SUN
Journal of Peking University(Health Sciences) 2025;57(1):121-127
OBJECTIVE:
To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner (IOS) integrated with a compressed airflow system, so as to provide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces.
METHODS:
The study selected a standard model as the scanning object, adhering to the "YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner" guidelines, a standard that defined parameters for intraoral scanning. To establish a baseline for accuracy, the ATOS Q 12M scanner, known for its high precision, was used to generate true reference values. These true values served as the benchmark for evaluating the IOS performance. Building on the design of an existing scanner, a new scanning head was developed to integrate with a compressed airflow system. This new design aimed to help the IOS capture high-precision data on surfaces where liquid-interference, such as saliva, might otherwise degrade scanning accuracy. The traditional scanning method, without airflow assistance, was employed as a control group for comparison. The study included five groups in total, one control group and four experimental groups, to investigate the effects of scanning lens obstruction, airflow presence, liquid media, and the use of the new scanning head on scanning process and accuracy. Each group underwent 15 scans, generating ample data for a robust statistical comparison. By evaluating trueness and precision in each group, the study assessed the impact of the compressed airflow system on the accuracy of IOS data collected from liquid-interference surfaces. Additionally, we selected Elite and Primescan scanners as references for numerical accuracy values.
RESULTS:
The scanning accuracy on liquid-interference surfaces was significantly reduced in terms of both trueness and precision [Trueness: 18.5 (6.5) vs. 38.0 (6.7), P < 0.05; Precision: 19.1 (8.5) vs. 31.7 (15.0), P < 0.05]. The use of the new scanning head assisted by the compressed airflow system significantly improved the scanning accuracy [Trueness: 22.3(7.6) vs. 38.0 (6.7), P < 0.05; Precision: 25.8 (9.6) vs. 31.7 (15.0), P < 0.05].
CONCLUSION
The scanning head based on the compressed airflow system can assist in improving the accuracy of data obtained from liquid-interference surfaces by the IOS.
Imaging, Three-Dimensional/methods*
;
Humans
;
Dental Impression Technique/instrumentation*
3.New intraoral digital impression with pneumatic gingival retraction used in the restoration of crown for posterior teeth: a case report
Xinkai XU ; Meizi ZHANG ; Zhongning LIU ; Yuchun SUN ; Hu CHEN ; Weiwei LI ; Xiaoyi ZHAO ; Yongjie JIA ; Shujuan XIAO ; Chao MA ; Xiaojun CHEN ; Tengfei JIANG ; Xiaobo ZHAO ; Sukun TIAN
Chinese Journal of Stomatology 2024;59(10):1044-1048
In fixed prosthodontics, clear exposure of the preparation margin is the prerequisite for obtaining accurate digital impressions and improving the marginal fit of restorations. To resolve the issues associated with the cord retraction technique, such as pain, acute injury, and prolonged procedural time, this study proposes a new technology for intraoral digital impression taking with pneumatic gingival retraction. The new scanning head blows a high-speed airflow that instantaneously separates the free gingiva, locally exposing the subgingival preparation margin. Combined with the farthest point preservation stitching algorithm based on the distance from the normal vector and high-speed laser scanning photography, it achieves global preparation edge data and gingival reconstruction, realizing painless, non-invasive, and efficient precise acquisition of the preparation margin. Using this new technique, a patient with a full porcelain crown restoration on a posterior tooth was treated. The digital impression revealed a clear margin of the preparation, and the crown made from this data has a good marginal fit.
4.A case of cutaneous collagenous vasculopathy
Bingluan LIU ; Xinkai ZHENG ; Shi WU ; Jin XU ; Liehua DENG ; Yunfeng HU ; Saijun LIU
Chinese Journal of Dermatology 2021;54(7):629-631
A 22-year-old female patient presented with skin flushing in the bilateral legs for 4 years, which gradually spread throughout the whole lower limbs and forearms 6 months ago. Skin examination showed diffuse flushing and dilated capillaries in the lower limbs and both forearms, and the flushing faded after a press. Histopathological examination of the skin lesion on the leg showed hyperkeratosis in a basket-like shape, increased pigmentation in the basal layer, infiltration of the superficial dermis with scattered lymphocytes, with no obvious red blood cell overflow; periodic acid-Schiff staining showed thickened and homogeneous deposits around the blood vessels; immunohistochemical staining showed thickened blood vessel walls and positive staining for type Ⅳ collagen. Diagnosis: cutaneous collagenous vasculopathy.
5.Utility of 64-MSCT in assessing acute non-reperfused myocardial infarct size
Xinkai QU ; Weiyi FANG ; Jianding YE ; Shaofeng GUAN ; Ruogu LI ; Yingjia XU ; Yan SHEN ; Min ZHANG ; Hua LIU
Journal of Geriatric Cardiology 2013;(3):247-252
Objective To evaluate the utility of multi-slice computed tomography (MSCT) in assessing acute non-reperfused myocardial infarct size. Methods Seven domestic pigs (mean weight 17.3 ± 1.9 kg) underwent ligation of the distal left anterior descending artery to establish a model of acute myocardial infarction (MI). MSCT and triphenyltetrazolium chloride (TTC) staining were performed two hours later. The following data were acquired and analyzed:MI volume (%), CT values of the infarcted region, left ventricular cavity and normal cardiac tissue at various scanning time-points (1, 5, 10, 15, 20 min after contrast injection). Results Using MSCT, the overall MI volume showed a time-dependent decrease, with a reduction of 28.87%after 20 min. The greatest reduction occurred at the 5 min time-point. In TTC staining, MI volume was 9.87%± 2.44%. When MI size, as determined by MSCT, was compared with that by TTC staining in Bland-Altman plots, there was a better agreement at 5, 10, and 15 min time-points at 1 and 20 min. Conclusions The study indicates that double-phase scanning examination using MSCT is a useful tool to assess MI size, and the optimal late-phase scanning time-point set within 5-15 min of contrast injection.
6.Study of analgesia and anti-inflammatory effect of Shui ethnic medicine Maguangwa*
Yalan XIA ; Xinkai YAO ; Yihong XU ; Yuesheng YU
Chongqing Medicine 2013;(23):2762-2764
Objective To investigate the analgesic and anti-inflammatory effects of Shui ethnic medicine Maguangwa .Methods Acetic acid-provoked writhing and hot plate provocation of pain were adopted to observe the analgesic effect of Shui ethnic medicine Maguangwa ,and xylene-induced ear swelling was used to observe the anti-inflammatory effect of Shui ethnic medicine Maguangwa There were five experimental groups ,i .e .,the blank control group ,the aspirin group(positive control) ,the 0 .84 g/kg Shui ethnic medicine Maguangwa group(group Ⅰ) ,the 0 .42 g/kg Shui ethnic medicine Maguangwa group(group Ⅱ ) ,and the 0 .21 g/kg Shui ethnic medicine Maguangwa group(group Ⅲ) .Results The writhing latency increased significantly and the writhing frequency de-creased significantly in the positive control group ,group Ⅰ and group Ⅱ ,when compared with the blank control group(P<0 .05) . The writhing latency and frequency differed insignificantly between group Ⅲ and the blank control group(P>0 .05) .Before medica-tion the pain threshold of mice in each group differed insignificantly (P>0 .05) .At 30 min ,60 min ,90 min and 120 min after medi-cation ,the pain threshold increased significantly in the positive control group ,group Ⅰ ,and group Ⅱ ,when compared to the blank control group(P<0 .05) .Meanwhile ,the pain threshold differed insignificantly between group Ⅰ and the positive control group(P>0 .05) ,or between group Ⅲ and the blank control group(P>0 .05) .When compared with the blank control group ,the right ear mass and degree of swelling decreased significantly in the positive control group ,group I and group Ⅱ (P<0 .05) .However ,the right ear mass and degree of swelling differed insignificantly between group Ⅰ and the positive control group(P>0 .05) ,or between group Ⅲ and the blank control group(P>0 .05) .Conclusion Shui ethnic medicine Maguangwa exhibits potent analgesic and anti-inflammatory effects in a dose-dependent manner .

Result Analysis
Print
Save
E-mail