1.Scoparone inhibits proliferation and invasion of colon cancer cell line HCT116
Wei HAN ; Wei PAN ; Man ZHANG ; Xiangyu GAO ; Xinkai KANG ; Zhibo ZHU ; Ruiting LIU
Basic & Clinical Medicine 2025;45(11):1429-1437
Objective To investigate the effects of scoparone(Sco)on proliferation and invasion of colon cancer cell line HCT116,and its effect on the expression of epidermal growth factor receptor(EGFR).Methods 1)HCT116 cells were divided into control group,50Sco group,100Sco group and 200Sco group.The cells in con-trol group were incubated with culture medium for 48 hrs.The 50Sco group,100Sco group and 200Sco group were incubated with 50,100 and 200 μmol/L scoparone for 48 hrs respectively.2)HCT116 cells were divided into con-trol group,NC-200Sco group,NC-LV+200Sco group and EGFR-LV+200Sco group.The control group was incuba-ted with normal culture medium for 48 hrs.NC-200Sco group was incubated with 200 μmol/L scoparone for 48 hrs.NC-LV and EGFR-LV were infected into HCT116 cells in NC-LV+200Sco group and EGFR-LV+200Sco group,then incubated with 200 μmol/L scoparone for 48 hrs.Cell proliferation was detected by MTT assay and EdU stai-ning,cell apoptosis was detected by flow cytometry and cell invasion was detected by Transwell assay.EGFR mRNA was detected by RT-qPCR,the level of EGFR,Bcl-2,Bax,matrix metalloproteinase(MMP)-2 and MMP-9 protein was detected by Western blot.Results Compared to the control group,the cell viability,proportion of EdU positive cells and counting number of invasive cells in 50Sco group,100Sco group and 200Sco group all decreased(P<0.05).Cell apoptosis rate and Bax protein expression increased(P<0.05),the protein expression of Bcl-2,MMP-2 and MMP-9 decreased(P<0.05).mRNA and protein expression of EGFR were de-creased(P<0.05).Compared with NC-200 Sco group and NC-LV+200Sco group,the expression level of mRNA and protein of EGFR in EGFR-LV+200Sco group was increased(P<0.05).Cell viability,proportion of EdU posi-tive cells and counting number of invasive cells all increased(P<0.05).The cell apoptosis rate and Bax protein expression level were decreased(P<0.05).The protein expression of Bcl-2,MMP-2 and MMP-9 was increased(P<0.05).Conclusions Scoparone has anti-colon cancer cell activity and inhibits proliferation as well as invasion of colon cancer cells through inhibition of EGFR.
2.Oral Herombopag Olamine and subcutaneous recombinant human thrombopoietin after haploidentical hematopoietic stem cell transplantation
Dai KONG ; Xinkai WANG ; Wenhui ZHANG ; Xiaohang PEI ; Cheng LIAN ; Xiaona NIU ; Honggang GUO ; Junwei NIU ; Zunmin ZHU ; Zhongwen LIU
Chinese Journal of Tissue Engineering Research 2025;29(1):1-7
BACKGROUND:Allogeneic hematopoietic stem cell transplantation is an important treatment for malignant hematological diseases,and delayed postoperative platelet implantation is a common complication that seriously affects the quality of patient survival;however,there are no standard protocols to improve platelet implantation rates and prevent platelet implantation delays. OBJECTIVE:To compare the safety and efficacy of oral Herombopag Olamine versus subcutaneous recombinant human thrombopoietin for promoting platelet implantation in patients with malignant hematological diseases undergoing haploid hematopoietic stem cell transplantation. METHODS:Clinical data of 163 patients with malignant hematological diseases who underwent haploidentical hematopoietic stem cell transplantation from January 2016 to October 2022 were retrospectively analyzed.A total of 72 patients who started to subcutaneously inject recombinant human thrombopoietin at+2 days were categorized into the recombinant human thrombopoietin group;a total of 27 patients who started to orally take Herombopag Olamine at+2 days were categorized into the Herombopag Olamine group;and 64 patients who did not apply Herombopag Olamine or recombinant human thrombopoietin were categorized into the blank control group.The implantation status,incidence of acute graft-versus-host disease of degree II-IV within 100 days,1-year survival rate,1-year recurrence rate,and safety were analyzed in the three groups. RESULTS AND CONCLUSION:(1)The average follow-up time was 52(12-87)months.The implantation time of neutrophils in the blank control group,recombinant human thrombopoietin group,and Herombopag Olamine group was(12.95±3.88)days,(14.04±3.71)days,and(13.89±2.74)days,respectively,with no statistically significant difference(P=0.352);the implantation time of platelets was(15.16±6.27)days,(17.67±6.52)days,and(17.00±4.75)days,with no statistically significant difference(P=0.287).(2)The complete platelet implantation rate on day 60 was 64.06%,90.28%,and 92.59%,respectively,and the difference was statistically significant(P<0.001).The subgroup analysis showed that the difference between the blank control group and the recombinant human thrombopoietin group was statistically significant(P<0.001),and the difference between the blank control group and the Herombopag Olamine group was statistically significant(P=0.004).The difference was not statistically significant between the recombinant human thrombopoietin group and Herombopag Olamine group(P=0.535).(3)100-day II-IV degree acute graft-versus-host disease incidence in the blank control group,recombinant human thrombopoietin group,and Herombopag Olamine group were 25.00%,30.56%,and 25.93%,respectively,and the difference was not statistically significant(P=0.752).(4)The incidence of cytomegalovirus anemia,cytomegalovirus pneumonia,and hepatic function injury had no statistical difference among the three groups(P>0.05).(5)During the follow-up period,there was no thrombotic event in any of the three groups of patients.(6)The results showed that recombinant human thrombopoietin and Herombopag Olamine could improve the platelet implantation rate of malignant hematological disease patients after haploidentical hematopoietic stem cell transplantation,with comparable efficacy and good safety.
3.Exploration and practice of course integration in medical imaging technology for a five-year medical imaging program based on education digitization
Zhijie YIN ; Xianglin LI ; Wen WANG ; Shuai WANG ; Quanyuan LIU ; Kang RONG ; Xinkai LIU ; Wei ZHANG
Chinese Journal of Medical Education Research 2025;24(2):209-214
In response to the new requirements for course instruction outlined in the revised training program for medical imaging program, this study integrated medical imaging technology courses based on the principle of outcome-oriented education and by leveraging self-developed digital resources, with imaging methods as the entry point. The core elements of the course teaching were re-optimized and reorganized to transcend the temporal and spatial limitations of course delivery, enabling the rational application of diverse teaching methods. This approach facilitated the integration of knowledge across three specialized courses, namely medical imaging physics, medical imaging equipment, and medical imaging examination techniques, and achieved full-dimensional and whole-process teaching evaluation. While reducing the number of hours allocated to theoretical instruction, the teaching objectives were achieved with high quality, providing a reference for the integration of digital technologies into the teaching of medical imaging and related disciplines.
4.Establishment and assessment of deep vein thrombosis model in rats in a plateau hypoxic environment
Xiaobo HAN ; Yahao CHAI ; Jiawei GAO ; Xinkai DENG ; Xiao LI ; Jialin WU ; Xiaoli HAN ; Guoxiang LI ; Yinjie ZHAO ; Xi YANG ; Qi AO ; Lei ZHANG ; Hongwei HAN ; Zhixue LIU
Acta Laboratorium Animalis Scientia Sinica 2025;33(8):1133-1143
Objective To establish a rat model of venous thrombosis in a plateau hypobaric hypoxic environment and to investigate the effect of this environment on venous thrombosis.Methods A total of 144 healthy male SD rats were assigned randomly to four groups(n=36 rats per group):a plains sham operation(A)group,plains operation(B)group,plateau altitude 6000 m+sham operation(C)group,and plateau altitude 6000 m+surgery(D)group.Rats in A and B groups were maintained in a plains normoxic environment,while rats in C and D groups C and D were subjected to a plateau environment.Rats in the surgical groups underwent quantitative constriction to incompletely obstruct the inferior vena cava blood flow.Each group was further divided into subgroups based on time:1,3,5,7,14,and 21 d(n=6 rats per group).Regular vascular ultrasound monitoring was conducted,and blood samples were taken for whole blood viscosity testing and the assessment of inflammatory indicators,including endothelin-1(ET-1),interleukin-6(IL-6)and tissue factor(TF).Coagulation function was evaluated through the activated partial thromboplastin time(APTT),prothrombin time(PT),thrombin time(TT),fibrinogen(FIB)and D-dimer.After the observation period,the experimental animals were sacrificed and the limbs were removed.Thrombus samples were stained with hematoxylin/eosin(HE),and the thrombus wet mass was measured.Results The thrombosis incidence was significantly higher in the plateau D group than in B group,accompanied by a marked increase in blood viscosity and hematocrit(P<0.01).Additionally,levels of ET-1,IL-6,and TF were significantly elevated(P<0.05),indicating a coagulation disorder.Conclusions A plateau hypoxic environment model can be successfully simulated by quantitative coarctation of the inferior vena cava,combined with a specialized environmental chamber.The findings of this study suggest that a plateau hypoxic environment promotes venous thrombosis.
5.Exploration and practice of course integration in medical imaging technology for a five-year medical imaging program based on education digitization
Zhijie YIN ; Xianglin LI ; Wen WANG ; Shuai WANG ; Quanyuan LIU ; Kang RONG ; Xinkai LIU ; Wei ZHANG
Chinese Journal of Medical Education Research 2025;24(2):209-214
In response to the new requirements for course instruction outlined in the revised training program for medical imaging program, this study integrated medical imaging technology courses based on the principle of outcome-oriented education and by leveraging self-developed digital resources, with imaging methods as the entry point. The core elements of the course teaching were re-optimized and reorganized to transcend the temporal and spatial limitations of course delivery, enabling the rational application of diverse teaching methods. This approach facilitated the integration of knowledge across three specialized courses, namely medical imaging physics, medical imaging equipment, and medical imaging examination techniques, and achieved full-dimensional and whole-process teaching evaluation. While reducing the number of hours allocated to theoretical instruction, the teaching objectives were achieved with high quality, providing a reference for the integration of digital technologies into the teaching of medical imaging and related disciplines.
6.Establishment and assessment of deep vein thrombosis model in rats in a plateau hypoxic environment
Xiaobo HAN ; Yahao CHAI ; Jiawei GAO ; Xinkai DENG ; Xiao LI ; Jialin WU ; Xiaoli HAN ; Guoxiang LI ; Yinjie ZHAO ; Xi YANG ; Qi AO ; Lei ZHANG ; Hongwei HAN ; Zhixue LIU
Acta Laboratorium Animalis Scientia Sinica 2025;33(8):1133-1143
Objective To establish a rat model of venous thrombosis in a plateau hypobaric hypoxic environment and to investigate the effect of this environment on venous thrombosis.Methods A total of 144 healthy male SD rats were assigned randomly to four groups(n=36 rats per group):a plains sham operation(A)group,plains operation(B)group,plateau altitude 6000 m+sham operation(C)group,and plateau altitude 6000 m+surgery(D)group.Rats in A and B groups were maintained in a plains normoxic environment,while rats in C and D groups C and D were subjected to a plateau environment.Rats in the surgical groups underwent quantitative constriction to incompletely obstruct the inferior vena cava blood flow.Each group was further divided into subgroups based on time:1,3,5,7,14,and 21 d(n=6 rats per group).Regular vascular ultrasound monitoring was conducted,and blood samples were taken for whole blood viscosity testing and the assessment of inflammatory indicators,including endothelin-1(ET-1),interleukin-6(IL-6)and tissue factor(TF).Coagulation function was evaluated through the activated partial thromboplastin time(APTT),prothrombin time(PT),thrombin time(TT),fibrinogen(FIB)and D-dimer.After the observation period,the experimental animals were sacrificed and the limbs were removed.Thrombus samples were stained with hematoxylin/eosin(HE),and the thrombus wet mass was measured.Results The thrombosis incidence was significantly higher in the plateau D group than in B group,accompanied by a marked increase in blood viscosity and hematocrit(P<0.01).Additionally,levels of ET-1,IL-6,and TF were significantly elevated(P<0.05),indicating a coagulation disorder.Conclusions A plateau hypoxic environment model can be successfully simulated by quantitative coarctation of the inferior vena cava,combined with a specialized environmental chamber.The findings of this study suggest that a plateau hypoxic environment promotes venous thrombosis.
7.Evaluation of the accuracy of three-dimensional data acquisition from liquid-inter-ference surfaces assisted by a scanner head with a compressed airflow system
Xinkai XU ; Jianjiang ZHAO ; Sukun TIAN ; Zhongning LIU ; Xiaoyi ZHAO ; Xiaobo ZHAO ; Tengfei JIANG ; Xiaojun CHEN ; Chao MA ; Yuchun SUN
Journal of Peking University(Health Sciences) 2025;57(1):121-127
Objective:To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner(IOS)integrated with a compressed airflow system,so as to pro-vide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces.Methods:The study selected a standard model as the scanning object,adhering to the"YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner"guidelines,a standard that defined parameters for intraoral scanning.To establish a baseline for accuracy,the ATOS Q 12M scanner,known for its high precision,was used to generate true reference values.These true values served as the benchmark for evaluating the IOS performance.Building on the design of an existing scanner,a new scanning head was developed to integrate with a compressed airflow system.This new design aimed to help the IOS capture high-precision data on sur-faces where liquid-interference,such as saliva,might otherwise degrade scanning accuracy.The tradi-tional scanning method,without airflow assistance,was employed as a control group for comparison.The study included five groups in total,one control group and four experimental groups,to investigate the effects of scanning lens obstruction,airflow presence,liquid media,and the use of the new scan-ning head on scanning process and accuracy.Each group underwent 15 scans,generating ample data for a robust statistical comparison.By evaluating trueness and precision in each group,the study as-sessed the impact of the compressed airflow system on the accuracy of IOS data collected from liquid-interference surfaces.Additionally,we selected Elite and Primescan scanners as references for numeri-cal accuracy values.Results:The scanning accuracy on liquid-interference surfaces was significantly reduced in terms of both trueness and precision[Trueness:18.5(6.5)vs.38.0(6.7),P<0.05;Preci-sion:19.1(8.5)vs.31.7(15.0),P<0.05].The use of the new scanning head assisted by the com-pressed airflow system significantly improved the scanning accuracy[Trueness:22.3(7.6)vs.38.0(6.7),P<0.05;Precision:25.8(9.6)vs.31.7(15.0),P<0.05].Conclusion:The scanning head based on the compressed airflow system can assist in improving the accuracy of data obtained from liquid-inter-ference surfaces by the IOS.
8.Clinical efficacy and safety analysis of cetuximab combined with mFOLFOX6 chemotherapy in the treatment of advanced colorectal cancer patients
Jiaqi LIU ; Wenjun WANG ; Ping ZHONG ; Min YANG ; Xinkai ZHAO
Journal of International Oncology 2024;51(12):763-768
Objective:To analyze the clinical efficacy of cetuximab combined with mFOLFOX6 chemotherapy regimen in the treatment of advanced colorectal cancer, to explore its effects on the distribution of T lymphocyte subsets, patients' physical status and tumor marker levels, and to analyze its safety.Methods:A total of 90 patients with advanced colorectal cancer admitted to the Hainan Cancer Hospital from April 2020 to April 2022 were selected and randomly divided into observation group ( n=45) and control group ( n=45) according to random number table method. The control group was treated with the mFOLFOX6 chemotherapy regimen, while the observation group was treated with cetuximab combined with the mFOLFOX6 chemotherapy regimen. Objective response rate (ORR), disease control rate (DCR), T lymphocyte subsets levels (percentages of CD3 +, CD4 +, CD8 +), Karnofsky performance status (KPS) score, tumor marker vascular endothelial growth factor (VEGF), endothelial cell-specific molecule 1 (ESM1), carcino-embryonic antigen (CEA) levels and the incidence of adverse reactions were compared between the two groups after treatment. Results:After 4 cycles of treatment, the ORR was 66.67% (30/45) in the observation group and 42.22% (19/45) in the control group, and there was a statistically significant difference ( χ2=5.42, P=0.020). The DCR of the observation group was 86.67% (39/45) and that of the control group was 66.67% (30/45), and there was a statistically significant difference ( χ2=5.03, P=0.025). The percentages of T lymphocyte subsets CD3 +, CD4 + and CD8 + in the observation group were (63.35±6.71) %, (35.67±3.96) % and (17.03±2.11) %, respectively, while those in the control group were (52.23±5.92) %, (30.55±3.51) % and (20.64±2.83) %, respectively. The percentages of CD3 + and CD4 + in the observation group were significantly higher than those in the control group ( t=8.34, P<0.001; t=6.49, P<0.001), while the percentage of CD8 + ratio was significantly lower ( t=6.86, P<0.001). The KPS score of the observation group was (95.55±9.74) points, and that of the control group was (85.03±8.92) points, and there was a statistically significant difference ( t=5.34, P<0.001). VEGF, ESM1 and CEA levels in the observation group were (303.45±33.21) ng/L, (75.66±8.36) pg/ml and (7.73±0.98) ng/ml, respectively, while those in the control group were (364.53±39.07) ng/L, (92.53±9.91) pg/ml and (9.95±1.13) ng/ml, respectively. VEGF, ESM1 and CEA levels in observation group were significantly lower compared with control group ( t=7.99, P<0.001; t=8.73, P<0.001; t=9.96, P<0.001). The total incidence of adverse reactions was 75.56% (34/45) in the observation group and 66.67% (30/45) in the control group, and there was no statistically significant difference ( χ2=0.87, P=0.352) . Conclusion:Cetuximab combined with mFOLFOX6 chemotherapy regimen in the treatment of advanced colorectal cancer patients has significant clinical efficacy, can improve the immune function of patients, alleviate clinical symptoms, regulate the level of serum tumor markers in patients without increasing adverse reactions, and has good safety.
9.Serum vitamin K2 level in children and its correlation with bone mineral density
Peikang WANG ; Xia JI ; Man ZHANG ; Xinkai ZHANG ; Xing LIU
Chinese Journal of Child Health Care 2024;32(3):286-290
【Objective】 To analyze the clinical characteristics of serum vitamin K
10.New intraoral digital impression with pneumatic gingival retraction used in the restoration of crown for posterior teeth: a case report
Xinkai XU ; Meizi ZHANG ; Zhongning LIU ; Yuchun SUN ; Hu CHEN ; Weiwei LI ; Xiaoyi ZHAO ; Yongjie JIA ; Shujuan XIAO ; Chao MA ; Xiaojun CHEN ; Tengfei JIANG ; Xiaobo ZHAO ; Sukun TIAN
Chinese Journal of Stomatology 2024;59(10):1044-1048
In fixed prosthodontics, clear exposure of the preparation margin is the prerequisite for obtaining accurate digital impressions and improving the marginal fit of restorations. To resolve the issues associated with the cord retraction technique, such as pain, acute injury, and prolonged procedural time, this study proposes a new technology for intraoral digital impression taking with pneumatic gingival retraction. The new scanning head blows a high-speed airflow that instantaneously separates the free gingiva, locally exposing the subgingival preparation margin. Combined with the farthest point preservation stitching algorithm based on the distance from the normal vector and high-speed laser scanning photography, it achieves global preparation edge data and gingival reconstruction, realizing painless, non-invasive, and efficient precise acquisition of the preparation margin. Using this new technique, a patient with a full porcelain crown restoration on a posterior tooth was treated. The digital impression revealed a clear margin of the preparation, and the crown made from this data has a good marginal fit.

Result Analysis
Print
Save
E-mail