1.Research progress on polydopamine in the treatment of oral diseases
LU Xiangxiang ; JIANG Zhen ; XING Aili ; ZHAO Bin ; SUN Bin
Journal of Prevention and Treatment for Stomatological Diseases 2026;34(3):302-3014
Due to the moist environment in the mouth, there are many challenges that arise, such as difficult biofilm removal, short drug retention time, and low tissue repair efficiency, while treating dental caries, periodontal disease, and other oral diseases. As a biomimetic biomaterial, polydopamine (PDA) possesses multifunctional properties, including mussel-inspired adhesion and stimuli-responsive drug release. PDA adhesion properties originate from its surface catechol and amino functional groups, which maintain strong wettability in aqueous environments. With smart responsiveness encompassing photothermal, pH, and enzymatic stimuli, PDA enables controlled drug release under specific conditions. Additionally, PDA exhibits antibacterial, anti-inflammatory, and osteoblast-promoting functions, thus demonstrating significant application potential in the treatment of oral diseases. In hard tissue therapies, specifically for dental caries, PDA promotes enamel remineralization by inducing hydroxyapatite crystal growth and enhances dentin collagen mineralization through Ca2+ chelation while inhibiting cariogenic bacteria. In mandibular defect repair, functionalized PDA coatings on bone implants facilitate mesenchymal stem cell adhesion and differentiation, activate osteogenic signaling pathways, and synergistically promote vascularization to improve bone-implant integration. For soft tissue treatments, specifically for periodontitis, PDA alleviates alveolar bone resorption via antibacterial and anti-inflammatory effects coupled with osteoclast inhibition. In denture stomatitis management, PDA’s strong wet adhesion prolongs drug retention, while its photothermal effect and reactive oxygen generation provide both broad-spectrum antibacterial activity and wound healing promotion. This review summarizes PDA’s synthesis mechanisms and biological functions, with an emphasis on its therapeutic applications in oral diseases, providing innovative strategies for oral healthcare.
2.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
3.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
4.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
5.Development and application on a full process disease diagnosis and treatment assistance system based on generative artificial intelligence.
Wanjie YANG ; Hao FU ; Xiangfei MENG ; Changsong LI ; Ce YU ; Xinting ZHAO ; Weifeng LI ; Wei ZHAO ; Qi WU ; Zheng CHEN ; Chao CUI ; Song GAO ; Zhen WAN ; Jing HAN ; Weikang ZHAO ; Dong HAN ; Zhongzhuo JIANG ; Weirong XING ; Mou YANG ; Xuan MIAO ; Haibai SUN ; Zhiheng XING ; Junquan ZHANG ; Lixia SHI ; Li ZHANG
Chinese Critical Care Medicine 2025;37(5):477-483
The rapid development of artificial intelligence (AI), especially generative AI (GenAI), has already brought, and will continue to bring, revolutionary changes to our daily production and life, as well as create new opportunities and challenges for diagnostic and therapeutic practices in the medical field. Haihe Hospital of Tianjin University collaborates with the National Supercomputer Center in Tianjin, Tianjin University, and other institutions to carry out research in areas such as smart healthcare, smart services, and smart management. We have conducted research and development of a full-process disease diagnosis and treatment assistance system based on GenAI in the field of smart healthcare. The development of this project is of great significance. The first goal is to upgrade and transform the hospital's information center, organically integrate it with existing information systems, and provide the necessary computing power storage support for intelligent services within the hospital. We have implemented the localized deployment of three models: Tianhe "Tianyuan", WiNGPT, and DeepSeek. The second is to create a digital avatar of the chief physician/chief physician's voice and image by integrating multimodal intelligent interaction technology. With generative intelligence as the core, this solution provides patients with a visual medical interaction solution. The third is to achieve deep adaptation between generative intelligence and the entire process of patient medical treatment. In this project, we have developed assistant tools such as intelligent inquiry, intelligent diagnosis and recognition, intelligent treatment plan generation, and intelligent assisted medical record generation to improve the safety, quality, and efficiency of the diagnosis and treatment process. This study introduces the content of a full-process disease diagnosis and treatment assistance system, aiming to provide references and insights for the digital transformation of the healthcare industry.
Artificial Intelligence
;
Humans
;
Delivery of Health Care
;
Generative Artificial Intelligence
6.Prediction of testicular histology in azoospermia patients through deep learning-enabled two-dimensional grayscale ultrasound.
Jia-Ying HU ; Zhen-Zhe LIN ; Li DING ; Zhi-Xing ZHANG ; Wan-Ling HUANG ; Sha-Sha HUANG ; Bin LI ; Xiao-Yan XIE ; Ming-De LU ; Chun-Hua DENG ; Hao-Tian LIN ; Yong GAO ; Zhu WANG
Asian Journal of Andrology 2025;27(2):254-260
Testicular histology based on testicular biopsy is an important factor for determining appropriate testicular sperm extraction surgery and predicting sperm retrieval outcomes in patients with azoospermia. Therefore, we developed a deep learning (DL) model to establish the associations between testicular grayscale ultrasound images and testicular histology. We retrospectively included two-dimensional testicular grayscale ultrasound from patients with azoospermia (353 men with 4357 images between July 2017 and December 2021 in The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China) to develop a DL model. We obtained testicular histology during conventional testicular sperm extraction. Our DL model was trained based on ultrasound images or fusion data (ultrasound images fused with the corresponding testicular volume) to distinguish spermatozoa presence in pathology (SPP) and spermatozoa absence in pathology (SAP) and to classify maturation arrest (MA) and Sertoli cell-only syndrome (SCOS) in patients with SAP. Areas under the receiver operating characteristic curve (AUCs), accuracy, sensitivity, and specificity were used to analyze model performance. DL based on images achieved an AUC of 0.922 (95% confidence interval [CI]: 0.908-0.935), a sensitivity of 80.9%, a specificity of 84.6%, and an accuracy of 83.5% in predicting SPP (including normal spermatogenesis and hypospermatogenesis) and SAP (including MA and SCOS). In the identification of SCOS and MA, DL on fusion data yielded better diagnostic performance with an AUC of 0.979 (95% CI: 0.969-0.989), a sensitivity of 89.7%, a specificity of 97.1%, and an accuracy of 92.1%. Our study provides a noninvasive method to predict testicular histology for patients with azoospermia, which would avoid unnecessary testicular biopsy.
Humans
;
Male
;
Azoospermia/diagnostic imaging*
;
Deep Learning
;
Testis/pathology*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Sperm Retrieval
;
Sertoli Cell-Only Syndrome/diagnostic imaging*
7.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
8.Effect of Tuina at "Weizhong (BL 40)" on Spinal Microglial Activation-related Proteins and the IL-10/β-EP Pathway in a Rat Model of Chronic Sciatic Nerve Compression Injury
Tianwei ZHANG ; Xiangqian LYU ; Yani XING ; Liuchen ZHU ; Qingguang ZHU ; Lingjun KONG ; Yanbin CHENG ; Zhen YAN ; Wuquan SUN ; Min FANG ; Zhiwei WU
Journal of Traditional Chinese Medicine 2025;66(7):734-740
ObjectiveTo investigate the analgesic effect of Tuina at the "Weizhong (BL 40)" on neuropathic pain in a rat model of chronic constriction injury (CCI) of the sciatic nerve and its potential central spinal mechanisms. MethodsThirty-two Sprague-Dawley rats were randomly divided into four groups (8 rats in each group), sham-operated group, model group, Tuina group, and blockade group. The CCI model was established in the model group, Tuina group, and the blockade group by ligating the sciatic nerve with catgut, while the sham-operated group underwent only sciatic nerve exposure without ligation. From postoperative day 4 to day 14, rats in the Tuina group and the blockade group received Tuina manipulation at the "Weizhong (BL 40)" using a dynamic pressure distribution measurement system (5 N pressure, 2 Hz frequency, 10 min per session, once daily). The blockade group also received intraperitoneal injections of the microglial inhibitor minocycline (10 mg/kg) once daily. The sham-operated and the model group underwent the same handling and fixation as the Tuina group without actual Tuina. Mechanical withdrawal threshold (MWT) and paw withdrawal latency (PWL) were measured before surgery and on day 3, 7, 10, and 14 post-surgery. Transmission electron microscopy was used to evaluate sciatic nerve injury and repair, measuring axon diameter and total myelinated fiber diameter to calculate the g-ratio. Western Blotting was performed to detect the protein levels of ionized calcium-binding adapter molecule 1 (Iba-1), CD206, CD68, interleukin-10 (IL-10), and β-endorphin (β-EP) precursor pro-opiomelanocortin (POMC) in the ipsilateral spinal dorsal horn. ResultsCompared with the sham-operated group, the model group showed significantly reduced MWT and PWL on day 3, 7, 10, and 14 (P<0.01). Compared with the model group, the Tuina group and the blockade group showed increased MWT and PWL on day 10 and 14 (P<0.05). Compared with the Tuina group, the blockade group exhibited higher MWT on day 7, 10, and 14, and higher PWL on day 10 (P<0.05). Sciatic nerve pathological morphology revealed intact and well-structured myelin in the sham-operated group, while the model group exhibited myelin collapse, distortion, and myelin ovoid formation. The Tuina group displayed partially irregular myelin with occasional myelin collapse, whereas the blockade group exhibited partial myelin irregularities and phospholipid shedding. Compared with the sham-operated group, the model group showed a decreased g-ratio and increased levels of Iba-1 and CD68 in the spinal dorsal horn (P<0.05 or P<0.01). Compared with the model group, the Tuina group and the blockade group exhibited an increased g-ratio and reduced Iba-1 and CD68 levels. Additionally, the Tuina group showed elevated levels of CD206, IL-10, and POMC, whereas the blockade group had decreased CD206 levels (P<0.05). ConclusionTuina at "Weizhong (BL 40)" alleviates neuropathic pain in CCI rats, potentially by regulating microglial activation in the spinal cord, inhibiting M1 polarization while promoting M2 polarization, and activating the IL-10/β-EP pathway to exert analgesic effects.
9.Short-Term Efficacy of Low-Dose Venetoclax Combined with CHG Priming Regimen in Patients with AML and High-Risk MDS Ineligible for Intensive Chemotherapy.
Yu-Ze YANG ; Mei ZHOU ; Ya-Ru XU ; Wen-Yan XU ; Jie SUN ; Yuan-Yuan ZHU ; Yuan LI ; Zhen-Xing GUO
Journal of Experimental Hematology 2025;33(3):660-665
OBJECTIVE:
To investigate the short-term efficacy and safety of low-dose venetoclax combined with CHG (cytarabine+homoharringtonine+G-CSF) priming regimen in patients with acute myeloid leukemia (AML) and high-risk myelodysplastic syndrome (MDS) ineligible for intensive chemotherapy.
METHODS:
The data of 14 patients with AML or high-risk MDS admitted to the department of hematology/oncology of the First Hospital of Tsinghua University and 2 cooperative institutions from July 2022 to August 2023 were retrospectively analyzed. All the patients were treated with low-dose venetoclax combined with CHG priming regimen and the early induction (one course) efficacy and adverse reactions were observed.
RESULTS:
Among the 14 patients, 10 were males and 4 were females, with a median age of 69.5 (46-83) years. After 1 cycle of induction chemotherapy, the complete remission (CR) rate was 64.3% (9/14) and overall response rate (ORR) was 78.6% (11/14). Among the 10 patients with adverse prognosis according to cytogenetics and molecular genetics, the CR rate was 50.0% (5/10), and ORR was 70.0% (7/10). In 7 patients with TP53 mutation, the CR rate was 42.9% (3/7) and ORR was 71.4% (5/7). In the 6 patients with complex karyotype, CR rate was 33.3% (2/6) and ORR was 66.7% (4/6). While the CR rate and ORR of 8 non-complex karyotype patients were both 87.5% (7/8), and the difference in CR rate between patients with complex karyotype and non-complex karyotype was statistically significant ( P < 0.05). The adverse reactions of chemotherapy were tolerable, without early treatment-related deaths.
CONCLUSION
Low-dose venetoclax combined with CHG priming regimen can be used as an effective treatment for AML and high-risk MDS patients who are ineligible for intensive chemotherapy, and it is safe and worthy of clinical application.
Humans
;
Leukemia, Myeloid, Acute/drug therapy*
;
Aged
;
Male
;
Female
;
Sulfonamides/therapeutic use*
;
Middle Aged
;
Myelodysplastic Syndromes/drug therapy*
;
Bridged Bicyclo Compounds, Heterocyclic/therapeutic use*
;
Aged, 80 and over
;
Retrospective Studies
;
Cytarabine/administration & dosage*
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Homoharringtonine/therapeutic use*
10.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]


Result Analysis
Print
Save
E-mail