1.Clinical study on treatment of complete radial tear of meniscus using arthroscopic All-inside single needle vertical suture technique.
Xinduo TIAN ; Yi MIAO ; Xin LIU ; Wei WANG ; Na LIU ; Xuesong ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):550-555
OBJECTIVE:
To explore the effectiveness of arthroscopic All-inside single needle vertical suture technique in treatment of complete radial tear of the meniscus.
METHODS:
Between January 2019 and January 2022, 18 patients (18 knees) with complete radial tear of the meniscus were treated by using arthroscopic All-inside single needle vertical suture technique. Among them, there were 12 males and 6 females with an average age of 37.1 years (range, 16-50 years). The causes of radial meniscus tears included the sports injuries in 11 cases, sprains/falls in 4 cases, and traffic accident injuries in 3 cases. The interval between injury and operation was 3-25 days (mean, 11.7 days). All patients had knee joint pain. Knee joint tenderness and McMurray sign were both positive. MRI showed the 15 cases of lateral meniscus tear and 3 cases of medial meniscus tear; 15 cases of anterior cruciate ligament injury, 1 case of posterior cruciate ligament injury, and 15 cases of tibial plateau bone contusion. Six patients underwent isolated meniscus repair and 12 patients with cruciate ligament rupture underwent meniscus repair and simultaneous cruciate ligament reconstruction. The operation time and incidence of postoperative complications were recorded. At last follow-up, the meniscus healing was evaluated according to Barrett's criteria and knee joint MRI, respectively. Lysholm score and International Knee Documentation Committee (IKDC) score were used to evaluate the functional recovery of the knee joint.
RESULTS:
The operation time was 19-28 minutes (mean, 23.3 minutes) in 6 patients with isolated meniscus repair and 38-52 minutes (mean, 45.8 minutes) in 12 patients with meniscus repair and simultaneous cruciate ligament reconstruction. All incisions healed by first intention. After operation, 1 patient developed the deep vein thrombosis of lower limb, the other patients had no complication. All patients were followed up 12-18 months (mean, 15.2 months). At last follow-up, 16 cases of meniscus reached clinical healing according to Barrett's criteria, with a healing rate of 88.9%. MRI re-examination of the knee joint showed that 5 cases had complete healing of the meniscus, 11 cases had partial healing, and 2 cases did not heal. The total healing rate (complete healing and partial healing) was 88.9%. After operation, the Lysholm score and IKDC score of 18 patients increased compared to preoperative scores, and further improved with time. The differences between different time points were significant ( P<0.05). Six patients with isolated meniscus repair had the same changes in the above scores, and the differences between the different time points were significant ( P<0.05).
CONCLUSION
The arthroscopic All-inside single needle vertical suture technique can achieve good short-term effectiveness in the treatment of complete radial tears of the meniscus.
Humans
;
Male
;
Adult
;
Female
;
Arthroscopy/methods*
;
Tibial Meniscus Injuries/surgery*
;
Middle Aged
;
Adolescent
;
Young Adult
;
Suture Techniques
;
Treatment Outcome
;
Magnetic Resonance Imaging
;
Anterior Cruciate Ligament Injuries/surgery*
;
Menisci, Tibial/surgery*
;
Knee Joint/surgery*
2.Measurement of Innovation Efficiency in Pharmaceutical Manufacturing Industry and Its Impact on Industrial Development
Xinduo ZHANG ; Hongling LI ; Yu WANG ; Shuyong FU
Herald of Medicine 2025;44(1):150-157
Objective To study the technological innovation efficiency of the pharmaceutical manufacturing industry and its relationship with industrial development.Methods The data from the China Statistical Yearbook,China High Tech Statistical Yearbook,the statistical yearbook data of regional statistical bureaus was collected to evaluate the technological innovation efficiency of the pharmaceutical manufacturing industry in 29 provinces and cities in China based on the super-efficiency three-stage SBM model.And then,the spatial econometric model and panel quantile regression model were used to conduct empirical research.Results The average technological innovation efficiency of the pharmaceutical manufacturing industry in 29 provinces was 0.49,with the east greater than the central region,and the central region greater than the west.The technological innovation efficiency of pharmaceutical manufacturing industry has a significant positive correlation with its industrial development,and the marginal effect of this effect shows a law of diminishing in regions with low to high development level,and there is a significant positive spatial spillover effect of pharmaceutical manufacturing industry development between regions.Conclusions The central and western provinces,which have relatively weak pharmaceutical manufacturing industries,should improve the innovation environment and talent supply to enhance the efficiency of technological innovation.Concerted efforts should be made to vigorously promote exchanges,connections,and cooperation between regions with strong technological innovation efficiency and their surrounding areas.And it is imperative to encourage top domestic pharmaceutical companies to significantly increase their investment in the research and development of innovative drugs and to actively engage in international competition.
3.Measurement of Innovation Efficiency in Pharmaceutical Manufacturing Industry and Its Impact on Industrial Development
Xinduo ZHANG ; Hongling LI ; Yu WANG ; Shuyong FU
Herald of Medicine 2025;44(1):150-157
Objective To study the technological innovation efficiency of the pharmaceutical manufacturing industry and its relationship with industrial development.Methods The data from the China Statistical Yearbook,China High Tech Statistical Yearbook,the statistical yearbook data of regional statistical bureaus was collected to evaluate the technological innovation efficiency of the pharmaceutical manufacturing industry in 29 provinces and cities in China based on the super-efficiency three-stage SBM model.And then,the spatial econometric model and panel quantile regression model were used to conduct empirical research.Results The average technological innovation efficiency of the pharmaceutical manufacturing industry in 29 provinces was 0.49,with the east greater than the central region,and the central region greater than the west.The technological innovation efficiency of pharmaceutical manufacturing industry has a significant positive correlation with its industrial development,and the marginal effect of this effect shows a law of diminishing in regions with low to high development level,and there is a significant positive spatial spillover effect of pharmaceutical manufacturing industry development between regions.Conclusions The central and western provinces,which have relatively weak pharmaceutical manufacturing industries,should improve the innovation environment and talent supply to enhance the efficiency of technological innovation.Concerted efforts should be made to vigorously promote exchanges,connections,and cooperation between regions with strong technological innovation efficiency and their surrounding areas.And it is imperative to encourage top domestic pharmaceutical companies to significantly increase their investment in the research and development of innovative drugs and to actively engage in international competition.
4.The harm and protective measures of facial occupational exposure of dental medical and nursing personnel
WANG Mengxi ; ZHANG Bo ; LI Yong ; ZHANG Xinduo ; GE Lifei ; CHANG Zhiqiang
Journal of Prevention and Treatment for Stomatological Diseases 2020;28(5):327-330
There are many kinds of medical facial protective equipment with different functions. However, due to the lack of recognition of the hazards of facial occupational exposure, an incomplete understanding of the functions and effects of protective equipment and a lack of awareness, the proportion of staff that wear protective equipment in the Department of Stomatology is low. In this paper, the harmful and protective effects of face occupational exposure of dental staff were reviewed. A literature review showed that with the increasing prevalence of infection with AIDS, hepatitis B, hepatitis C and multidrug resistant bacteria in recent years, the occupational infection rate of medical staff in the Department of Stomatology has increased. The noise generated during oral treatment and the light from photosensitive curing lamps and treatment or surgical lasers can also cause occupational damage to hearing and vision. Face protection measures lack comprehensive functioning, and there is a lack of products that can be easily worn, indicating that the functions of face protection products need to be improved and strengthened. To minimize occupational infection and injury, we should not only improve the existing protective equipment but also improve personal protection awareness through advertising and education and comprehensively explore effective measures to improve occupational safety to ultimately achieve safe and high-quality medical services.


Result Analysis
Print
Save
E-mail