1.Reconceptualizing Critical Illness in Cancer Through the Lens of Host Unregulated Response
Yun CHU ; Shiyi GONG ; Xin DING ; Hua ZHAO ; Huan CHEN ; Qing ZHANG ; Xiaoting WANG
Medical Journal of Peking Union Medical College Hospital 2026;17(1):1-9
Onco-critical care has emerged as an important subspecialty at the intersection of critical care medicine and oncology, attracting increasing attention in recent years. With continuous innovations in cancer therapies, patient survival has improved significantly; however, the incidence of associated critical complications has also increased. The reasons for cancer patients requiring intensive care unit admission are diverse and can be broadly categorized into three groups: progression of the underlying malignancy, treatment-related complications, and coexisting classical critical illnesses. Traditional critical care concepts and practices face limitations in addressing the multidimensional and heterogeneous challenges of onco-critical care. Based on the core mechanism of critical illness development—host/organ unregulated response (HOUR)—this article systematically elaborates on how this framework advances understanding and clinical practice into onco-critical care, with emphasis on its manifestations in neuroendocrine, immune-inflammatory, and coagulation-metabolic pathways. The review summarizes recent advances in clinical assessment and phenotyping systems for onco-critical illness and discusses a multidisciplinary, integrated management strategy centered on the "Disease Control, Host Response Modulation, Organ Support" triad. Finally, major challenges and future directions in this field are outlined. By integrating existing evidence and theoretical insights, this review aims to provide new perspectives and a theoretical foundation for the clinical management of onco-critical illness, thereby promoting its evolution toward precision and standardization.
2.Standards for the Application of Hemodynamic Monitoring Technology in Critical Care
Hua ZHAO ; Hongmin ZHANG ; Xin DING ; Huan CHEN ; Jun DUAN ; Wei DU ; Bo TANG ; Yuankai ZHOU ; Dongkai LI ; Xinchen WANG ; Cui WANG ; Gaosheng ZHOU ; Xiaoting WANG
Medical Journal of Peking Union Medical College Hospital 2026;17(1):73-85
With the rapid advancement of hemodynamic indices and monitoring technologies, their classification methods and application processes have become increasingly complex. Currently, no unified standard hasbeen established, making it difficult to fully meet the clinical requirements for hemodynamic management. To assist in hemodynamic monitoring assessment and therapeutic decision-making in critically ill patients, the Critical Hemodynamic Therapy Collaborative Group, in conjunction with the Critical Ultrasound Study Group, has jointly developed the Standard for the Application of Hemodynamic Monitoring Techniques in Critical Care. The first part of this standard systematically categorizes hemodynamic indicators into flow indicators, pressure and its derivative indicators, and tissue perfusion indicators, while elaborating on the clinical application of each. The second part establishes a standardized clinical implementation pathway for hemodynamic monitoring. It proposes a tiered monitoring strategy-comprising basic, advanced, indication-specific, and special scenario monitoring-tailored to different clinical settings. It emphasizes the central role of critical care ultrasound across all levels of monitoring and establishes hemodynamic assessment standards for organs such as the brain, kidneys, and gastrointestinal tract. This standard aims to provide a unified framework for clinical practice, teaching, training, and research in critical care medicine, thereby promoting standardized development within the discipline.
3.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
4.The Specificity of Electroacupuncture at Different Acupoints in Promoting Cerebrospinal Fluid Flow in Mice
Yu SHI ; Qian HUA ; Tian-Tian PENG ; Yu-Xin NIE ; Zhao-Heng LIU ; Chen-Geng DENG ; Xu WANG
Progress in Biochemistry and Biophysics 2026;53(5):1154-1164
ObjectiveCerebrospinal fluid (CSF) plays a crucial role in maintaining the homeostasis of the central nervous system (CNS). CSF rapidly exchanges with interstitial fluid (ISF) via the glymphatic system within the brain parenchyma. CSF-ISF circulation and its associated mechanisms are often referred to as the brain lymphatic system. This system is connected directly to meningeal lymphatic vessels (mLVs), jointly performing the function of clearing metabolic waste from the CNS. Emerging evidence indicates that this system is closely associated with the onset and progression of neurodegenerative diseases (NDs) such as Alzheimer’s disease (AD). Importantly, abnormal CSF circulation is not only a downstream consequence of AD pathology, but also a risk factor. In AD, the dynamics of CSF flow within the CNS are diminished, immune dysregulation occurs, and this may increase the risk of AD by exacerbating the burden of amyloid β-protein (Aβ). In the mouse model of AD, impaired CSF flow compromises this clearance function, leading to cognitive deficits. Clinically, acupuncture at cognition-related acupoints is commonly used for the prevention and treatment of AD. However, whether its therapeutic effects are mediated through the modulation of CSF dynamics remains unclear. This study aimed to evaluate the impact of acupuncture on CSF flow and investigate its acupoint specificity. MethodsMice were randomly assigned to experimental groups for the different electroacupuncture groups with the following acupoints: Baihui point (GV 20), Ear point, Neiguan point (PC 6), and Tianshu point (ST 25). Wild-type mice on a C57BL/6J background were used as controls. Fluorescent tracer was injected into the cisterna magna to label CSF flow. Fluorescence imaging was employed to assess the distribution of CSF within the brain before and after acupuncture stimulation. ResultsFollowing tracer injection into the cisterna magna, fluorescence signals rapidly reached the cerebellum and medulla—the regions closest to the injection site. Fluorescence intensity was higher in ventral brain regions compared to dorsal regions, likely due to greater vascular density in ventral areas facilitating CSF-ISF exchange. Electroacupuncture at the GV 20 produced the most pronounced enhancement of CSF across the whole brain, while stimulation at the ST 25 primarily augmented flow within subcortical regions. In contrast, electroacupuncture at the Ear point or the PC 6 had no observable effect on CSF in mice. ConclusionElectroacupuncture promotes CSF flow into the brain parenchyma in an acupoint-specific manner, with GV 20 exhibiting the most pronounced enhancement of CSF dynamics. These findings suggest that acupuncture-mediated facilitation of CSF flow may represent a potential therapeutic strategy for preventing or delaying age-related cognitive decline.
5.The Specificity of Electroacupuncture at Different Acupoints in Promoting Cerebrospinal Fluid Flow in Mice
Yu SHI ; Qian HUA ; Tian-Tian PENG ; Yu-Xin NIE ; Zhao-Heng LIU ; Chen-Geng DENG ; Xu WANG
Progress in Biochemistry and Biophysics 2026;53(5):1154-1164
ObjectiveCerebrospinal fluid (CSF) plays a crucial role in maintaining the homeostasis of the central nervous system (CNS). CSF rapidly exchanges with interstitial fluid (ISF) via the glymphatic system within the brain parenchyma. CSF-ISF circulation and its associated mechanisms are often referred to as the brain lymphatic system. This system is connected directly to meningeal lymphatic vessels (mLVs), jointly performing the function of clearing metabolic waste from the CNS. Emerging evidence indicates that this system is closely associated with the onset and progression of neurodegenerative diseases (NDs) such as Alzheimer’s disease (AD). Importantly, abnormal CSF circulation is not only a downstream consequence of AD pathology, but also a risk factor. In AD, the dynamics of CSF flow within the CNS are diminished, immune dysregulation occurs, and this may increase the risk of AD by exacerbating the burden of amyloid β-protein (Aβ). In the mouse model of AD, impaired CSF flow compromises this clearance function, leading to cognitive deficits. Clinically, acupuncture at cognition-related acupoints is commonly used for the prevention and treatment of AD. However, whether its therapeutic effects are mediated through the modulation of CSF dynamics remains unclear. This study aimed to evaluate the impact of acupuncture on CSF flow and investigate its acupoint specificity. MethodsMice were randomly assigned to experimental groups for the different electroacupuncture groups with the following acupoints: Baihui point (GV 20), Ear point, Neiguan point (PC 6), and Tianshu point (ST 25). Wild-type mice on a C57BL/6J background were used as controls. Fluorescent tracer was injected into the cisterna magna to label CSF flow. Fluorescence imaging was employed to assess the distribution of CSF within the brain before and after acupuncture stimulation. ResultsFollowing tracer injection into the cisterna magna, fluorescence signals rapidly reached the cerebellum and medulla—the regions closest to the injection site. Fluorescence intensity was higher in ventral brain regions compared to dorsal regions, likely due to greater vascular density in ventral areas facilitating CSF-ISF exchange. Electroacupuncture at the GV 20 produced the most pronounced enhancement of CSF across the whole brain, while stimulation at the ST 25 primarily augmented flow within subcortical regions. In contrast, electroacupuncture at the Ear point or the PC 6 had no observable effect on CSF in mice. ConclusionElectroacupuncture promotes CSF flow into the brain parenchyma in an acupoint-specific manner, with GV 20 exhibiting the most pronounced enhancement of CSF dynamics. These findings suggest that acupuncture-mediated facilitation of CSF flow may represent a potential therapeutic strategy for preventing or delaying age-related cognitive decline.
6.Consensus on Hemodynamic Management in Adult Veno-Arterial Extracorporeal Membrane Oxygenation (2026 Edition)
Wei CHENG ; Shuhan CAI ; Ying ZHU ; Zhongran CEN ; Hua ZHAO ; Huan CHEN ; Yangong CHAO ; Xiaoting WANG ; Xin DING
Medical Journal of Peking Union Medical College Hospital 2026;17(3):784-797
Despite significant advances in the field of critical care medicine over the past three decades, veno-arterial extracorporeal membrane oxygenation (V-A ECMO) remains the primary temporary mechanical circulatory support modality for patients with acute severe circulatory failure. With the accumulation of clinical experience and the increasing maturity of operational techniques in V-A ECMO, its technical management—particularly hemodynamic management—has become a key factor influencing patient outcomes. To further improve patient survival, the Chinese Critical Care Ultrasound Study Group, in collaboration with the Hemodynamic Therapy of Critical Care Collaborative Group and the Critical Care Medicine Branch of the China International Exchange and Promotive Association for Medical and Health Care, organized experts in critical care medicine to develop the
7.Development of A Low Field Ion Extraction System for Time-of-Flight Secondary Ion Mass Spectrometry
De-Ze WANG ; Chen-Xin WU ; Yi CHEN ; Fu-Xin DU ; Lei HUA ; Hai-Yang LI ; Jian-Hua WANG ; Ping CHEN
Chinese Journal of Analytical Chemistry 2025;53(7):1072-1081
Time-of-flight secondary ion mass spectrometer(TOF-SIMS)is a highly sensitive surface analysis instrument with high spatial resolution.Traditional TOF-SIMS instruments for sample targets use high field extraction methods.Although the ion collection efficiency is high,it is prone to issues such as low-energy ion beam defocusing,sample morphology sensitivity,and organic molecule ion dissociation.This study aimed to develope an efficient low-field ion extraction system suitable for TOF-SIMS with a continuous beam source.The SIMION simulation software was used to construct a model of the secondary ion optical extraction system.The key factors affecting the extraction efficiency were studied,and the structural parameters of the extraction cone were optimized.Using an indium target as the sample,an experimental test of the performance of the ion extraction system was carried out on the TOF-SIMS instrument.The influences of the voltages of the ion extraction cone and the single lens on the ion extraction efficiency were consistent with the simulation results.By adopting the technology of deflection and coaxial dynamic compensation,the imaging field of view of the ion extraction system was increased to 500 μm×500 μm.The energy window of the ion extraction system reached 10 eV,and the large imaging depth of field of 400 μm was achieved.In the test of a 5 mg/L cholesterol thin film sample,the signal-to-noise ratio of the characteristic peak[M-OH]+reached 4453.The results showed that this low-field secondary ion extraction system effectively improved the performance of the continuous beam TOF-SIMS instrument.
8.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
9."Component-effect" correlations in traditional Chinese medicine from holistic view: taking discovery of gintonin from ginseng as an example.
Xin-Ming YU ; Chen-Yu YU ; Hua-Ying WANG ; Wei-Sheng YUE ; Zhu-Bin ZHANG ; Wei WU ; Xiao-Bin JIA ; Bing YANG ; Liang FENG
China Journal of Chinese Materia Medica 2025;50(7):2001-2012
The holistic view is the key in the study of traditional Chinese medicine(TCM). The component structure theory is based on the holistic view to investigate the correlation between material basis and efficiency, which enriches the holistic "component-effect" research of TCM. Gintonin is a newly isolated non-saponin component of ginseng. Compared to ginsenosides, gintonin has many different pharmacological activities, and it provides new knowledge for the holistic research of ginseng. Thus, taking the discovery of gintonin from ginseng as an example, this paper explored the linkage between ginsenosides and gintonin from the perspective of "component-effect" correlations and systematically sorted out the similarities and differences between them in terms of structural characteristics, modes of action, and pharmacological activities. Starting from the collaborative interaction of TCM compounds, the study discussed the application and value of the holistic view in TCM "component-effect" research in the light of the component structure theory to provide new thoughts for the development of modern TCM research.
Panax/chemistry*
;
Drugs, Chinese Herbal/pharmacology*
;
Medicine, Chinese Traditional
;
Humans
;
Ginsenosides/pharmacology*
;
Animals
10.Metabolomics and pharmacokinetics of Corni Fructus in ameliorating myocardial ischemic injury.
Xiang-Feng LIU ; Yu WU ; Chao-Yan YANG ; Hua-Wei LIAO ; Yan-Fen CHEN ; Xin HE ; Ying-Fang WANG ; Jin-Ru LIANG
China Journal of Chinese Materia Medica 2025;50(5):1363-1376
This study aims to investigate the ameliorating effect of Corni Fructus(CF) on the myocardial ischemic injury and the pharmacokinetic properties of characteristic components of CF. The mouse model of isoproterenol-induced myocardial ischemia was established and administrated with the aqueous extract of CF. The general efficacy of CF in ameliorating the myocardial ischemic injury was evaluated based on the cardiac histopathology and the levels of myocardial injury markers: creatine kinase isoenzyme(CK-MB) and cardiac troponin I(cTn-I). The metabolomics analysis was carried out for the heart and serum samples of mice to screen the biomarkers of CF in ameliorating the myocardial ischemic injury and then the predicted biomarkers were submitted to metabolic pathway enrichment. The pharmacokinetic analysis was performed for morroniside, loganin, and cornuside Ⅰ in mouse heart and serum samples to obtain the pharmacokinetic parameters of these components. The pharmacokinetic parameters were then integrated on the basis of self-defined weighting coefficients to simulate an integrated pharmacokinetic profile of CF iridoid glycosides in the heart and serum of the mouse model of myocardial ischemia. The results indicated that CF reduced the pathological damage to cardiac cells and tissue(hematoxylin-eosin staining) and lowered the levels of CK-MB and cTn-I in the serum of the mouse model of myocardial ischemia(P<0.01). Metabolomics analysis screed out 31 endogenous metabolites in the heart and 35 in the serum as biomarkers of CF in ameliorating the myocardial ischemic injury. These biomarkers were altered by modeling and restored by CF. Six metabolic pathways in the heart and 5 in the serum were enriched based on these metabolic markers. The main integrated pharmacokinetic parameters of CF iridoid glycosides were T_(max)=1 h, t_(1/2)=(1.52±0.05) h in the heart and T_(max)=1 h, t_(1/2)=(1.56±0.50) h in the serum. Both concentration-time curves showed a double-peak phenomenon. In conclusion, CF demonstrated the cardioprotective effect by regulating metabolic pathways such as taurine and hypotaurine metabolism, and pantothenic acid and coenzyme A biosynthesis. The integrated pharmacokinetics reflect the general pharmacokinetic properties of characteristic components in CF.
Animals
;
Cornus/chemistry*
;
Mice
;
Metabolomics
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Myocardial Ischemia/metabolism*
;
Humans
;
Troponin I/metabolism*
;
Myocardium/pathology*
;
Disease Models, Animal
;
Biomarkers/metabolism*
;
Creatine Kinase, MB Form/metabolism*

Result Analysis
Print
Save
E-mail