1.Residual Inflammatory Risk and Intracranial Atherosclerosis Plaque Vulnerability: Insights From High-Resolution Magnetic Resonance Imaging
Ying YU ; Rongrong CUI ; Xin HE ; Xinxin SHI ; Zhikai HOU ; Yuesong PAN ; Mingyao LI ; Jiabao YANG ; Zhongrong MIAO ; Yongjun WANG ; Rong WANG ; Xin LOU ; Long YAN ; Ning MA
Journal of Stroke 2025;27(2):207-216
Background:
and Purpose This study aimed to investigate the association between residual inflammatory risk (RIR) and vulnerable plaques using high-resolution magnetic resonance imaging (HRMRI) in symptomatic intracranial atherosclerotic stenosis (ICAS).
Methods:
This retrospective study included 70%–99% symptomatic ICAS patients hospitalized from January 2016 to December 2022. Patients were classified into four groups based on high-sensitivity C-reactive protein (hs-CRP) and low-density lipoprotein cholesterol (LDL-C): residual cholesterol inflammatory risk (RCIR, hs-CRP ≥3 mg/L and LDL-C ≥2.6 mmol/L), RIR (hs-CRP ≥3 mg/L and LDL-C <2.6 mmol/L), residual cholesterol risk (RCR, hs-CRP <3 mg/L and LDL-C ≥2.6 mmol/L), and no residual risk (NRR, hs-CRP <3 mg/L and LDL-C <2.6 mmol/L). Vulnerable plaque features on HRMRI included positive remodeling, diffuse distribution, intraplaque hemorrhage, and strong enhancement.
Results:
Among 336 included patients, 21, 60, 58, and 197 were assigned to the RCIR, RIR, RCR, and NRR groups, respectively. Patients with RCIR (adjusted odds ratio [aOR], 3.606; 95% confidence interval [CI], 1.346–9.662; P=0.011) and RIR (aOR, 3.361; 95% CI, 1.774–6.368, P<0.001) had higher risks of strong enhancement than those with NRR. Additionally, patients with RCIR (aOR, 2.965; 95% CI, 1.060–8.297; P=0.038) were more likely to have intraplaque hemorrhage compared with those with NRR. In the sensitivity analysis, RCR (aOR, 2.595; 95% CI, 1.201–5.608; P=0.015) exhibited an additional correlation with an increased risk of intraplaque hemorrhage.
Conclusion
In patients with symptomatic ICAS, RIR is associated with a higher risk of intraplaque hemorrhage and strong enhancement, indicating an increased vulnerability to atherosclerotic plaques.
2.Residual Inflammatory Risk and Intracranial Atherosclerosis Plaque Vulnerability: Insights From High-Resolution Magnetic Resonance Imaging
Ying YU ; Rongrong CUI ; Xin HE ; Xinxin SHI ; Zhikai HOU ; Yuesong PAN ; Mingyao LI ; Jiabao YANG ; Zhongrong MIAO ; Yongjun WANG ; Rong WANG ; Xin LOU ; Long YAN ; Ning MA
Journal of Stroke 2025;27(2):207-216
Background:
and Purpose This study aimed to investigate the association between residual inflammatory risk (RIR) and vulnerable plaques using high-resolution magnetic resonance imaging (HRMRI) in symptomatic intracranial atherosclerotic stenosis (ICAS).
Methods:
This retrospective study included 70%–99% symptomatic ICAS patients hospitalized from January 2016 to December 2022. Patients were classified into four groups based on high-sensitivity C-reactive protein (hs-CRP) and low-density lipoprotein cholesterol (LDL-C): residual cholesterol inflammatory risk (RCIR, hs-CRP ≥3 mg/L and LDL-C ≥2.6 mmol/L), RIR (hs-CRP ≥3 mg/L and LDL-C <2.6 mmol/L), residual cholesterol risk (RCR, hs-CRP <3 mg/L and LDL-C ≥2.6 mmol/L), and no residual risk (NRR, hs-CRP <3 mg/L and LDL-C <2.6 mmol/L). Vulnerable plaque features on HRMRI included positive remodeling, diffuse distribution, intraplaque hemorrhage, and strong enhancement.
Results:
Among 336 included patients, 21, 60, 58, and 197 were assigned to the RCIR, RIR, RCR, and NRR groups, respectively. Patients with RCIR (adjusted odds ratio [aOR], 3.606; 95% confidence interval [CI], 1.346–9.662; P=0.011) and RIR (aOR, 3.361; 95% CI, 1.774–6.368, P<0.001) had higher risks of strong enhancement than those with NRR. Additionally, patients with RCIR (aOR, 2.965; 95% CI, 1.060–8.297; P=0.038) were more likely to have intraplaque hemorrhage compared with those with NRR. In the sensitivity analysis, RCR (aOR, 2.595; 95% CI, 1.201–5.608; P=0.015) exhibited an additional correlation with an increased risk of intraplaque hemorrhage.
Conclusion
In patients with symptomatic ICAS, RIR is associated with a higher risk of intraplaque hemorrhage and strong enhancement, indicating an increased vulnerability to atherosclerotic plaques.
3.Study on Zinc Oxide/Ferrous Sulfide Heterojunction Ethanol Gas Sensor
Ji-Jin SHI ; Sen-Rong YE ; Jin-Peng LUO ; Chi ZHANG ; Xin HE ; Wei-Jia YANG
Chinese Journal of Analytical Chemistry 2025;53(3):375-386
Ethanol detection plays an important role in food industry,environmental monitoring,medical health monitoring,prevention of drunk driving,etc.The development of low-cost,high-performance ethanol sensors has important application value.In this study,a ZnO/FeS nano heterojunction ethanol sensor was prepared on commercial ceramic silver electrode substrate.The sensing characteristics of the sensor for ethanol gas were systematically studied.The results showed that ZnO had a nanowire structure,and the FeS was coated on the ZnO nanowire in the form of nanosheets.The sensor performed well for ethanol detection in environments with relative humidity ranging from 30%to 60%,with a detection range from 0.2 mg/m3 to 50 mg/m3.At the optimum operating temperature of 300℃,the response of ZnO/FeS nano heterojunction sensor to 50 mg/m3 ethanol was 15.6,the response time was 5.0 s,and the detection limit was as low as 0.101 mg/m3,which was obviously better than that of commercial ethanol sensor.This sensor was highly selective for ethanol compared to other gases such as CO,NH3,acetone,etc,and could steadily work for 30 days.The fabricated sensor had good development potential in the field of low-cost and high-performance ethanol gas detection.
4.Visualization and Analysis of Sweat Pore Features in Latent Fingerprints Using Core-Shell Structured Composite Nanofibrous Membrane
Shi-Yue MA ; Ya-Li PEI ; Hong-Yu CHEN ; Xin DU ; Yan-Feng ZHANG ; Rong-Liang MA ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(8):1269-1278
Introducing fingerprint level 3 features(especially sweat pores)in fingerprint recognition can significantly improve the value of fingerprints.However,conventional fingerprint visualization methods suffer from issues such as poor stability and reproducibility,insufficient resolution,and feature masking in detecting level 3 features.Electrospun membrane has unique advantages in latent fingerprint(LFP)detection due to its excellent adsorption performance and high specific surface area,and thus its application potential in LFP visualization urgently need to be explored.A novel pore visualization method based on core-shell structured PAN-Flu/PVP composite nanofibrous membrane was proposed in this work.Specifically,the PAN-Flu/PVP composite nanofibrous membrane was prepared via coaxial electrospinning technology,with polyacrylonitrile(PAN)loaded with fluorescein(Flu)as the core and polyvinylpyrrolidone(PVP)as the shell.The experimental results showed that the prepared PAN Flu/PVP composite nanofibrous membrane had a porous structure and excellent adsorption performance.Based on the water solubility of the outer shell PVP and the water induced fluorescence enhancement effect of the core Flu,high-resolution visualization of sweat pores could be achieved within 2 s.The optimization experiment showed that the best quality of sweat latent fingerprints was obtained when the Flu content was 4 mg/mL,the spinning time was 1 h,and the sweating time was 2 min.Through repeated fingerprinting and live fingerprint comparison experiment,the strong stability and high reproducibility of the as-produced membrane in displaying fingerprint sweat pores were finally verified.In summary,the development method could quickly,stably and accurately extract the spatial distribution and activity level of fingerprint sweat pores,which was of great significance for improving the utilization and value of fingerprints.
5.Short- to medium-term safety and efficacy of the implantable Corheart 6 left ventricular assist system in patients with end-stage heart failure
Zhibing QIU ; Xiaochun SONG ; Liangpeng LI ; Hongwei SHI ; Liqiong XIAO ; Yunzhang WU ; Xiaosong RONG ; Jidan FAN ; Liang WEI ; Xin CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):639-645
Objective To investigate the efficacy and safety of the Corheart 6 left ventricular assist system in patients with end-stage heart failure. Methods A retrospective study was conducted on patients with end-stage heart failure who were treated with Corheart 6 left ventricular assist system from March 2022 to June 2024 in 4 hospitals in Jiangsu Province. The efficacy of the device was evaluated by comparing changes in clinical indicators at preoperative, discharge, 3-month postoperative, and 6-month postoperative timepoints, including the New York Heart Association (NYHA) functional classification, left ventricular ejection fraction (LVEF), and left ventricular end-diastolic diameter (LVEDD). The safety of the device was assessed by analyzing the intraoperative position and orientation of the blood pump inlet cannula, as well as the incidence of adverse events. Results In this study, 39 patients were collected, including 34 males and 5 females with a mean age of (56.4±12.5) years, ranging from 20 to 75 years. There was no operative death. There was no death in postoperative 3 months with a survival rate of 100.0%. There were 3 deaths in 6 months postoperatively, with a survival rate of 92.3%. All patients had a preoperative NYHA cardiac function classification of class Ⅳ. The NYHA cardiac function class of the patients improved (P<0.05) at discharge, 3 and 6 months after surgery when compared to the preoperative period. LVEF was significantly higher at 3 months after surgery than that during the preoperative period (P<0.05). LVEDD was significantly smaller at discharge, 3 and 6 months after surgery than that during the preoperative period (P<0.05). The safety evaluation's findings demonstrated that all 39 patients' intraoperative blood pump inlet tubes were oriented correctly, the artificial blood vessel suture sites were appropriate, there were no instances of device malfunction or pump thrombosis, or instances of bleeding or hemolysis, and the rate of the remaining adverse events was low. Conclusion With a low rate of adverse events and an excellent safety profile, the Corheart 6 left ventricular assist system can efficiently enhance cardiac function in patients with end-stage heart failure. It also has considerable clinical uses.
6.Residual Inflammatory Risk and Intracranial Atherosclerosis Plaque Vulnerability: Insights From High-Resolution Magnetic Resonance Imaging
Ying YU ; Rongrong CUI ; Xin HE ; Xinxin SHI ; Zhikai HOU ; Yuesong PAN ; Mingyao LI ; Jiabao YANG ; Zhongrong MIAO ; Yongjun WANG ; Rong WANG ; Xin LOU ; Long YAN ; Ning MA
Journal of Stroke 2025;27(2):207-216
Background:
and Purpose This study aimed to investigate the association between residual inflammatory risk (RIR) and vulnerable plaques using high-resolution magnetic resonance imaging (HRMRI) in symptomatic intracranial atherosclerotic stenosis (ICAS).
Methods:
This retrospective study included 70%–99% symptomatic ICAS patients hospitalized from January 2016 to December 2022. Patients were classified into four groups based on high-sensitivity C-reactive protein (hs-CRP) and low-density lipoprotein cholesterol (LDL-C): residual cholesterol inflammatory risk (RCIR, hs-CRP ≥3 mg/L and LDL-C ≥2.6 mmol/L), RIR (hs-CRP ≥3 mg/L and LDL-C <2.6 mmol/L), residual cholesterol risk (RCR, hs-CRP <3 mg/L and LDL-C ≥2.6 mmol/L), and no residual risk (NRR, hs-CRP <3 mg/L and LDL-C <2.6 mmol/L). Vulnerable plaque features on HRMRI included positive remodeling, diffuse distribution, intraplaque hemorrhage, and strong enhancement.
Results:
Among 336 included patients, 21, 60, 58, and 197 were assigned to the RCIR, RIR, RCR, and NRR groups, respectively. Patients with RCIR (adjusted odds ratio [aOR], 3.606; 95% confidence interval [CI], 1.346–9.662; P=0.011) and RIR (aOR, 3.361; 95% CI, 1.774–6.368, P<0.001) had higher risks of strong enhancement than those with NRR. Additionally, patients with RCIR (aOR, 2.965; 95% CI, 1.060–8.297; P=0.038) were more likely to have intraplaque hemorrhage compared with those with NRR. In the sensitivity analysis, RCR (aOR, 2.595; 95% CI, 1.201–5.608; P=0.015) exhibited an additional correlation with an increased risk of intraplaque hemorrhage.
Conclusion
In patients with symptomatic ICAS, RIR is associated with a higher risk of intraplaque hemorrhage and strong enhancement, indicating an increased vulnerability to atherosclerotic plaques.
7.Enhanced radiotheranostic targeting of integrin α5β1 with PEGylation-enabled peptide multidisplay platform (PEGibody): A strategy for prolonged tumor retention with fast blood clearance.
Siqi ZHANG ; Xiaohui MA ; Jiang WU ; Jieting SHEN ; Yuntao SHI ; Xingkai WANG ; Lin XIE ; Xiaona SUN ; Yuxuan WU ; Hao TIAN ; Xin GAO ; Xueyao CHEN ; Hongyi HUANG ; Lu CHEN ; Xuekai SONG ; Qichen HU ; Hailong ZHANG ; Feng WANG ; Zhao-Hui JIN ; Ming-Rong ZHANG ; Rui WANG ; Kuan HU
Acta Pharmaceutica Sinica B 2025;15(2):692-706
Peptide-based radiopharmaceuticals targeting integrin α5β1 show promise for precise tumor diagnosis and treatment. However, current peptide-based radioligands that target α5β1 demonstrate inadequate in vivo performance owing to limited tumor retention. The use of PEGylation to enhance the tumor retention of radiopharmaceuticals by prolonging blood circulation time poses a risk of increased blood toxicity. Therefore, a PEGylation strategy that boosts tumor retention while minimizing blood circulation time is urgently needed. Here, we developed a PEGylation-enabled peptide multidisplay platform (PEGibody) for PR_b, an α5β1 targeting peptide. PEGibody generation involved PEGylation and self-assembly. [64Cu]QM-2303 PEGibodies displayed spherical nanoparticles ranging from 100 to 200 nm in diameter. Compared with non-PEGylated radioligands, [64Cu]QM-2303 demonstrated enhanced tumor retention time due to increased binding affinity and stability. Importantly, the biodistribution analysis confirmed rapid clearance of [64Cu]QM-2303 from the bloodstream. Administration of a single dose of [177Lu]QM-2303 led to robust antitumor efficacy. Furthermore, [64Cu]/[177Lu]QM-2303 exhibited low hematological and organ toxicity in both healthy and tumor-bearing mice. Therefore, this study presents a PEGibody-based radiotheranostic approach that enhances tumor retention time and provides long-lasting antitumor effects without prolonging blood circulation lifetime. The PEGibody-based radiopharmaceutical [64Cu]/[177Lu]QM-2303 shows great potential for positron emission tomography imaging-guided targeted radionuclide therapy for α5β1-overexpressing tumors.
8.Enhancement of Ca2+ Signal Strength in Astrocytes in the Lateral Septum Improves Cognitive Disorders in Mice After Hemorrhagic Shock and Resuscitation.
Wen-Guang LI ; Lan-Xin LI ; Rong-Xin SONG ; Xu-Peng WANG ; Shi-Yan JIA ; Xiao-Yi MA ; Jing-Yu ZHANG ; Gang-Feng YIN ; Xiao-Ming LI ; Li-Min ZHANG
Neuroscience Bulletin 2025;41(8):1403-1417
Hemorrhagic shock is a common clinical emergency that can aggravate cell injury after resuscitation. Astrocytes are crucial for the survival of neurons because they regulate the surrounding ionic microenvironment of neurons. Although hemorrhagic shock and resuscitation (HSR) injury can impair cognition, it remains unclear how this insult directly affects astrocytes. In this study, we established an HSR model by bleeding and re-transfusion in mice. The social interaction test and new object recognition test were applied to evaluate post-operative cognitive changes, and the results suggest that mice experience cognitive impairment following exposure to HSR. In the HSR group, the power spectral density of β and γ oscillations decreased, and the coupling of the θ oscillation phase and γ oscillation amplitude was abnormal, which indicated abnormal neuronal oscillation and cognitive impairment after HSR exposure. In brief, cognitive impairment in mice is strongly correlated with Ca2+ signal strength in lateral septum astrocytes following HSR.
Animals
;
Astrocytes/metabolism*
;
Shock, Hemorrhagic/metabolism*
;
Resuscitation/adverse effects*
;
Male
;
Mice
;
Calcium Signaling/physiology*
;
Mice, Inbred C57BL
;
Septal Nuclei/metabolism*
;
Cognitive Dysfunction/etiology*
;
Disease Models, Animal
;
Cognition Disorders/etiology*
9.Comparison of outcomes between enhanced workflows and express workflows in robotic-arm assisted total hip arthroplasty.
Xiang ZHAO ; Xiang-Hua WANG ; Rong-Xin HE ; Xun-Zi CAI ; Li-Dong WU ; Hao-Bo WU ; Shi-Gui YAN
China Journal of Orthopaedics and Traumatology 2025;38(10):987-993
OBJECTIVE:
To explore the differences in clinical efficacy between enhanced workflows and express workflows in robotic-assisted total hip arthroplasty(THA).
METHODS:
A retrospective analysis was conducted on 46 patients who underwent robotic-assisted THA between November 2020 and May 2021. They were divided into the enhanced workflows group and the express workflows group based on the surgical methods. There were 20 patients in the enhanced workflows group, including 11 males and 9 females;aged from 51 to 78 years old with an average of (67.30±7.52) years old. The BMI ranged from 18.24 to 24.03 kg·m-2 with an average of(23.80±3.01) kg·m-2. There were 26 patients in the express workflows group, including 12 males and 14 females;aged from 57 to 84 years old with a mean age of (67.58±7.29) years old, and their BMI ranged from 19.72 to 30.08 kg·m-2 with an average of (24.41 ±2.92) kg·m-2. The operation time, hospital stay, and perioperative complications of the patients were recorded. The postoperative acetabular prosthesis anteversion angle, abduction angle, limb length, and offset distance data were measured. The Harris hip score at the latest follow-up was recorded.
RESULTS:
All patients completed the surgery as planned and were followed up, with the follow-up period ranging from 47 to 54 months with a mean of (49.78±1.85) months and the length of hospital stay ranging from 2 to 11 days with an average of (6.57±1.82 ) days. The operation time of enhanced workflows group was (93.41±16.41) minutes, which was longer than that of the express workflow groups (75.19±18.36) minutes, and the difference was statistically significant (P<0.05). In enhanced workflows group, the postoperative acetabular anteversion angle was (19.20±4.46)°, the limb length discrepancy was (-1.55±9.13) mm, and changes of the offset was (-5.15±6.77) mm. The corresponding values in express workflows group were (20.46±3.29)°, (2.19±4.39) mm, and (-2.39±4.34) mm, respectively. There was no statistically significant difference in these indicators between the two groups(P>0.05). One patient in the enhanced workflows group developed deep venous thrombosis after surgery. No cases of dislocation or periprosthetic infection. At the latest follow-up, all patients had well-positioned prostheses without loosening. Harris hip score was (90.50±1.67) points in enhanced workflows group and (90.73±2.36) points in the express workflows group, with no statistically significant difference between the two groups (P>0.05).
CONCLUSION
The clinical efficacy of robot assisted total hip arthroplasty technology is satisfactory. The enhanced workflows will increase the surgical time. For patients with normal anatomical hip joint disease, this study did not find significant advantages in joint stability and functional scoring for the enhanced workflows.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Aged, 80 and over
;
Workflow
;
Treatment Outcome
10.Bone loss in patients with spinal cord injury: Incidence and influencing factors.
Min JIANG ; Jun-Wei ZHANG ; He-Hu TANG ; Yu-Fei MENG ; Zhen-Rong ZHANG ; Fang-Yong WANG ; Jin-Zhu BAI ; Shu-Jia LIU ; Zhen LYU ; Shi-Zheng CHEN ; Jie-Sheng LIU ; Jia-Xin FU
Chinese Journal of Traumatology 2025;28(6):477-484
PURPOSE:
To investigate the incidence and influencing factors of bone loss in patients with spinal cord injury (SCI).
METHODS:
A retrospective case-control study was conducted. Patients with SCI in our hospital from January 2019 to March 2023 were collected. According to the correlation between bone mineral density (BMD) at different sites, the patients were divided into the lumbar spine group and the hip joint group. According to the BMD value, the patients were divided into the normal bone mass group (t > -1.0 standard deviation) and the osteopenia group (t ≤ -1.0 standard deviation). The influencing factors accumulated as follows: gender, age, height, weight, cause of injury, injury segment, injury degree, time after injury, start time of rehabilitation, motor score, sensory score, spasticity, serum value of alkaline phosphatase, calcium, and phosphorus. The trend chart was drawn and the influencing factors were analyzed. SPSS 26.0 was used for statistical analysis. Correlation analysis was used to test the correlation between the BMD values of the lumbar spine and bilateral hips. Binary logistic regression analysis was used to explore the influencing factors of osteoporosis after SCI. p < 0.05 was considered statistically significant.
RESULTS:
The incidence of bone loss in patients with SCI was 66.3%. There was a low concordance between bone loss in the lumbar spine and the hip, and the hip was particularly susceptible to bone loss after SCI, with an upward trend in incidence (36% - 82%). In this study, patients with SCI were divided into the lumbar spine group (n = 100) and the hip group (n = 185) according to the BMD values of different sites. Then, the lumbar spine group was divided into the normal bone mass group (n = 53) and the osteopenia group (n = 47); the hip joint group was divided into the normal bone mass group (n = 83) and the osteopenia group (n = 102). Of these, lumbar bone loss after SCI is correlated with gender and weight (p = 0.032 and < 0.001, respectively), and hip bone loss is correlated with gender, height, weight, and time since injury (p < 0.001, p = 0.015, 0.009, and 0.012, respectively).
CONCLUSIONS
The incidence of bone loss after SCI was high, especially in the hip. The incidence and influencing factors of bone loss in the lumbar spine and hip were different. Patients with SCI who are male, low height, lightweight, and long time after injury were more likely to have bone loss.
Humans
;
Spinal Cord Injuries/complications*
;
Male
;
Female
;
Retrospective Studies
;
Incidence
;
Adult
;
Bone Density
;
Middle Aged
;
Case-Control Studies
;
Osteoporosis/etiology*
;
Lumbar Vertebrae
;
Bone Diseases, Metabolic/etiology*
;
Aged
;
Risk Factors

Result Analysis
Print
Save
E-mail