2.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
3.Comparative epidemiology and treatment outcomes at trauma centers: A cross-national analysis of the United States and China.
Yong FU ; Liu-Yi FAN ; Xin-Jie LUO ; Lei LI ; Delbrynth P MITCHAO ; Kenji INABA ; Guan-Qiao LIU ; Bin YU
Chinese Journal of Traumatology 2025;28(6):399-403
PURPOSE:
Although there are significant differences between China and the United States (US) in trauma medical services, there has been no direct comparative research on the epidemiological data of trauma centers between the 2 countries. This study aims to fill this research gap by directly comparing trauma centers in China and the US, providing valuable data and insights for the development of trauma centers in both countries, promoting academic exchange and cooperation internationally, and enhancing the level of global trauma medical care.
METHODS:
This is a multicenter retrospective descriptive study. Data were collected for trauma patients with an injury severity score ≥16 treated from September 2013 to September 2019 at 2 hospital trauma centers in these 2 countries. Detailed clinical data (including injury mechanism, age, injury site, injury severity score, pre-hospital transport time, whether blood transfusion was performed, whether resuscitative thoracotomy was conducted, hospital and intensive care unit stay duration, the number of organ donor patients, mortality rates, and costs) were meticulously compiled and retrospectively analyzed to identify differences between the 2 trauma centers. The comparison was conducted using SPSS 23 software. Continuous variables are reported as median (Q1, Q3), and Mann Whitney U test is used to compare the median of continuous variables. Use clinically relevant critical points to classify continuous variables, with categorical variables represented as n (%), and comparisons were made between the 2 groups using the χ2 test or Fisher's exact test. Statistical significance was defined as a 2-sided p < 0.05.
RESULTS:
These results point to significant differences in trauma center capacity, pre-hospital transport times, treatment procedures, hospital stay duration, mortality rates, and costs between the 2 centers. The volume of patients in trauma centers is less in China (2465 vs. 5288). Pre-hospital transport time was notably longer in China (180 min vs. 14 min), and the rate of emergency blood transfusions was lower in China (18.4% vs. 50.6%), Emergency thoracotomy was not performed in China but was conducted in 9.8% of cases in the US. Hospitalization costs were significantly lower in China than in the US ($5847 vs. $75,671).
CONCLUSION
There are clear differences in trauma center capacity (number of patients treated), pre-hospital transport time, age distribution of injured patients, injury mechanisms, injury sites, whether emergency thoracotomy is performed, hospital costs, and length of stay between the 2 trauma centers in China and America. Understanding these differences can help us further recognize the characteristics of Eastern and Western trauma patients.
Humans
;
China/epidemiology*
;
Trauma Centers/statistics & numerical data*
;
Retrospective Studies
;
United States/epidemiology*
;
Male
;
Female
;
Wounds and Injuries/therapy*
;
Middle Aged
;
Adult
;
Injury Severity Score
;
Length of Stay/statistics & numerical data*
;
Treatment Outcome
4.Explanation and interpretation of blood transfusion provisions for children with hematological diseases in the national health standard "Guideline for pediatric transfusion".
Ming-Yi ZHAO ; Rong HUANG ; Rong GUI ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(1):18-25
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion is one of the most commonly used supportive treatments for children with hematological diseases. This guideline provides guidance and recommendations for blood transfusions in children with aplastic anemia, thalassemia, autoimmune hemolytic anemia, glucose-6-phosphate dehydrogenase deficiency, acute leukemia, myelodysplastic syndromes, immune thrombocytopenic purpura, and thrombotic thrombocytopenic purpura. This article presents the evidence and interpretation of the blood transfusion provisions for children with hematological diseases in the "Guideline for pediatric transfusion", aiming to assist in the understanding and implementing the blood transfusion section of this guideline.
Humans
;
Child
;
Hematologic Diseases/therapy*
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
5.Explanation and interpretation of the compilation of blood transfusion provisions for children undergoing hematopoietic stem cell transplantation in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(2):139-143
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion for children undergoing hematopoietic stem cell transplantation is highly complex and challenging. This guideline provides recommendations on transfusion thresholds and the selection of blood components for these children. This article presents the evidence and interpretation of the transfusion provisions for children undergoing hematopoietic stem cell transplantation, with the aim of enhancing the understanding and implementation of the "Guideline for pediatric transfusion".
Humans
;
Hematopoietic Stem Cell Transplantation
;
Child
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
6.Explanation and interpretation of blood transfusion provisions for critically ill and severely bleeding pediatric patients in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI
Chinese Journal of Contemporary Pediatrics 2025;27(4):395-403
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Critically ill children often present with anemia and have a higher demand for transfusions compared to other pediatric patients. This guideline provides guidance and recommendations for blood transfusions in cases of general critical illness, septic shock, acute brain injury, extracorporeal membrane oxygenation, non-life-threatening bleeding, and hemorrhagic shock. This article interprets the background and evidence of the blood transfusion provisions for critically ill and severely bleeding children in the "Guideline for pediatric transfusion", aiming to enhance understanding and implementation of this aspect of the guidelines. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(4): 395-403.
Humans
;
Critical Illness
;
Blood Transfusion/standards*
;
Child
;
Hemorrhage/therapy*
;
Practice Guidelines as Topic
7.Explanation and interpretation of blood transfusion provisions for children undergoing cardiac surgery in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Ming-Hua YANG ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Jin-Ping LIU
Chinese Journal of Contemporary Pediatrics 2025;27(7):778-785
To guide clinical blood transfusion practices in pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Children undergoing cardiac surgery are at high risk of bleeding, and the causes of perioperative anemia and coagulation disorders in neonates and children are complex and varied, often necessitating the transfusion of allogeneic blood components. This guideline provides direction and recommendations for specific measures in blood management for children undergoing cardiac surgery before, during, and after surgery. This article interprets the background and evidence for the formulation of the blood transfusion provisions for children undergoing cardiac surgery, hoping to facilitate the understanding and implementation of this guideline.
Humans
;
Cardiac Surgical Procedures
;
Blood Transfusion/standards*
;
Child
;
Practice Guidelines as Topic
8.Construction of a postoperative mortality risk model for patients with acute aortic dissection based on XGBoost-SHAP method
Xin ZHANG ; Min FANG ; Yi CAO ; Ting-Ting LI ; Xian-Kong LIU ; Jia-Yi DANG ; Xue-Sen ZHAO ; Hong-Qin REN ; Jia-Ze GENG ; Kai-Wen WANG ; Tie-Sheng HAN ; Yong-Bo ZHAO ; Dong MA
Medical Journal of Chinese People's Liberation Army 2025;50(10):1226-1234
Objective To develop a predictive model for postoperative mortality risk in patients with acute aortic dissection(AAD)using the Extreme Gradient Boosting(XGBoost)algorithm combined with Shapley Additive Explanation(SHAP),and to establish a prediction website to serve as a diagnostic and therapeutic support platform for clinicians and patients.Methods A retrospective cohort study design was adopted.Data from 782 AAD patients who underwent surgical treatment at the Fourth Hospital of Hebei Medical University from January 2013 to December 2023 were collected,including basic information and initial serum biomarker test results.Patients were randomly divided into training and test sets at a 7:3 ratio.An external validation set consisting of 313 AAD patients admitted to the Second Hospital of Hebei Medical University from January 2020 to December 2023 was also established for further model validation.Variables were screened using LASSO regression,and an XGBoost machine learning model was constructed and interpreted using SHAP.The predictive performance of the model was evaluated using receiver operating characteristic(ROC)curve analysis.Using the Shiny package,the XGBoost model was deployed to shinyapps.io to create a prediction website for postoperative mortality risk in AAD patients.One patient was selected by simple random sampling from the test set and the external validation set respectively for the prediction example on the Shiny webpage.Results The XGBoost model demonstrated high predictive performance for postoperative mortality in AAD patients,with area under the ROC curve(AUC)values of 0.928(95%CI 0.901-0.956)in the training set,0.919(95%CI 0.891-0.949)in the test set,and 0.941(95%CI 0.915-0.967)in the external validation set.SHAP values indicated the following order of variable importance in the model(from highest to lowest):"lactate dehydrogenase""blood chlorine""multiple organ injury""carbon dioxide combining power""prothrombin time""α-hydroxybutyric acid""creatine kinase isoenzyme""Stanford classification""combined use of bedside blood purification""gender""acute kidney injury""gastrointestinal bleeding""brain injury"and"shock".A risk prediction website for adverse postoperative outcomes in AAD patients was developed using XGBoost-SHAP method(https://dun-dunxiaolu.shinyapps.io/document/)and validated with examples.One randomly selected patient from each of the test and external validation sets was applied:the predicted mortality risk value for patient 1(who died postoperatively)was 0.9539,and that for patient 2(who survived postoperatively)was 0.0206.Conclusions The XGBoost-SHAP model demonstrates high accuracy in predicting postoperative mortality risk for AAD patients.The online prediction tool established based on this model enhances the identification efficiency of high-risk postoperative mortality patients.
9.Mechanism of P-bodies recruiting NANOS3 during early oogenesis
Jian-Wei GENG ; Fei HE ; Yi-Dan MA ; Yong-Rui ZHOU ; Xin-Yi MU
Acta Anatomica Sinica 2025;56(3):323-328
Objective To explore the relationship between NANOS3 and P-bodies in oocytes and the mechanism of their interaction during early oogenesis.Methods The co-localization of NANOS3 and dead box helicase 6(DDX6)in day post postnatal 1(1dpp)mouse oocytes was observed by immunofluorescence,and the interaction between NANOS3 and DDX6 was detected by immunoprecipitation.NANOS3 and DDX6 full-length plasmids were constructed to transfect HEK293T cells,and the mechanism of their interaction was investigated by immunofluorescence and immunoprecipitation.NANOS3 transfected HeLa cells to investigate whether NANOS3 had the ability of liquid-liquid phase separation(LLPS)by live-cell imaging.The proteins recruited by P-bodies in early oogenesis were identified by DDX6-immunoprecipitation-mass spectrometry(DDX6-IP-MS).Results NANOS3 and DDX6 colocalized and interacted with each other in 1dpp mouse oocytes.However,the co-localization of NANOS3 and DDX6 was not observed in HEK293T cells that had been transfected,but co-immunoprecipitation still demonstrated an interaction between these two proteins.Besides,live-cell imaging revealed that NANOS3 exhibited dynamic fluid-like properties within cells,which may promote the formation of P-bodies through LLPS.Finally,DDX6-IP-MS revealed that DDX6 might recruit NANOS3 into P-bodies by binding to the NANOS3 interacting protein Pumilio.Conclusion NANOS3 serves as a specific component of P-bodies in neonatal oocytes and may be involved in the regulation of early oogenesis.
10.The early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee
Jinyang LI ; Zhuangzhuang LI ; Taojun GONG ; Xin HU ; Linyun TAN ; Yong ZHOU ; Yi LUO ; Minxun LU ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(11):735-741
Objective:To explore the early and mid-term efficacy of three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee.Methods:A retrospective analysis was conducted on the data of 24 patients who underwent reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee using 3D-printed customized porous prostheses at West China Hospital of Sichuan University from June 2015 to June 2021. There were 14 female cases and 10 male cases, with an average age of 28.9±16.5 years (range, 12-61 years), 12 cases at the distal end of the femur and 12 cases at the proximal end of the tibia. Tumor types: 16 cases of osteosarcoma, 4 cases of Ewing's sarcoma, 2 cases of chondrosarcoma, and 2 case of parosteal osteosarcoma. All patients were classified as Enneking stage IIB. Record the oncology results of the patients, the length of tumor segment resection, and the remaining bone length at the distal femur or proximal tibia, as well as complications, systemic metastasis and imaging changes. The bone integration at the prosthesis-bone interface was evaluated by tomosynthesis-shimadzu metal artifact reduction technology (T-SMART). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS)-93 score and knee range of motion assessment.Results:All 24 patients successfully completed the surgery and were followed up, with an average follow-up time of 51.8±12.7 months (range, 32-99 months). The length of femoral osteotomy was 241.1±66.2 mm (range, 150.6-333.4 mm), and the length of tibial osteotomy was 198.6±35.6 mm (range, 156.6-287.6 mm). The remaining bone length at the epiphyseal end around the knee joint (from the knee joint plane to the osteotomy plane of the distal femur or proximal tibia) was 52.6±11.0 mm (range, 31.1-77.5 mm). At the last follow-up, 23 patients survived tumor-free, while one patient died due to lung metastasis 54 months after the operation. One patient had prosthesis fracture 75 months after the operation, two patients had aseptic loosening 6 and 8 months after the operation, and the T-SMART of the remaining 20 patients showed that the implanted prostheses all achieved good osseointegration. At the last follow-up, the range of motion of the knee joint was 126.2°±7.5° (range, 110.0°-140.0°), and the MSTS-93 score was 26.7±1.8 points (range, 23-30 points). Among them, the MSTS-93 score of the femoral prosthesis was 26.7±1.6 points (range, 24-29 points), and the MSTS-93 score of the tibial prosthesis was 26.9±1.9 points (range, 23-30 points). The average knee range of motion was 126.2°±7.5° (range, 110°-140°), and the MSTS-93 functional score was 26.7±1.8 points (range, 23-30 points) at the last follow-up. The femoral component had an average score of 26.7±1.6 points (range, 24-29 points), while the tibial component had an average score of 26.9±1.9 points (range, 23-30 points).Conclusion:The application three-dimensional printed customized porous prosthesis with preserved articular in the reconstruction of ultra-long segmental bone defect around the metaphysis of peri-knee can preserve the joint, restore limb function well, and have a low incidence of prosthesis complications, with good clinical efficacy in the early and middle stages.

Result Analysis
Print
Save
E-mail