1.Clinical effects of Jingu Xiaotong Powder combined with platelet-rich plasma on patients with knee osteoarthritis
Rui-Xin ZHANG ; Qin-Jian WANG ; Xing-Fu JIANG ; Bo-Bo LI ; Dong-Kang XU
Chinese Traditional Patent Medicine 2024;46(2):465-469
AIM To investigate the clinical effects of Jingu Xiaotong Powder combined with platelet-rich plasma on patients with knee osteoarthritis.METHODS Ninety-six patients were randomly assigned into control group(48 cases)for 8-week administration of platelet-rich plasma,and observation group(48 cases)for 8-week administration of both Jingu Xiaotong Powder and platelet-rich plasma.The changes in clinical effects,IL-17,SDF-1,TLR4,GSH-Px,NO,ox-LDL,WOMAC scores,TCM syndrome score,AIM2-SF score were detected.RESULTS The observation group demonstrated higher total effective rate than the control group(P<0.05).After the treatment,the two groups displayed decreased IL-17,SDF-1,TLR4,NO,ox-LDL,WOMAC scores,TCM syndrome score(P<0.05),and increased GSH-Px,AIM2-SF score(P<0.05),especially for the observation group(P<0.05).CONCLUSION For the patients with knee osteoarthritis,Jingu Xiaotong Powder combined with platelet-rich plasma can reduce IL-17,SDF-1,TLR4 levels,inhibit body inflammation,improve oxidative stress indices,alleviate pain,and enhance clinical efficacy and life quality.
2.Synthesis of Polyvinyl Alcohol/Polypyrrole Conductive Organogel and Its Application in Human Activity Monitoring
Xing-Yue MA ; Yuan-Yuan ZHANG ; Fu-Xin SUN ; Ling-Yu ZHANG ; Chong-Bo MA
Chinese Journal of Analytical Chemistry 2024;52(7):945-954
To address the shortcomings of traditional hydrogels in terms of mechanical performance and environmental stability,a new conductive organogel based on polyvinyl alcohol(PVA)and polypyrrole(PPy)was prepared in this study.By introducing dimethyl sulfoxide(DMSO)as a solvent,the mechanical strength and durability of the gel were significantly improved.Various characterization techniques,including infrared spectroscopy,thermogravimetric analysis,and scanning electron microscopy were used to characterize this conductive organogel.The experimental results showed that the prepared organogel exhibited optimal performance at PVA concentration level of 8%(m/m),with an average pore size of 5.2 μm and a conductivity of 0.65 S/cm.As a wearable strain sensor,the PVA/PPy organogel demonstrated excellent sensitivity and responsiveness,capable of precisely detecting joint and muscle movements as well as subtle physiological signals such as pulse and vocal cord vibrations.Notably,the gel maintained stable sensing performance even after 48 h at room temperature,showing outstanding environmental adaptability and long-term use potential.This innovative material design provided robust technical support for smart healthcare,health monitoring,and human-machine interaction,showing broad application prospects.
3.Feasibility of X-ray field area optimization for Cyberknife image guidance
Rui ZHAO ; Jing ZHANG ; Xing-Xin GAO ; Zhong-Ze TIAN ; Xiao-Bo CAO ; Sha LI
Chinese Medical Equipment Journal 2024;45(11):49-53
Objective To investigate the effect of reducing the image-guided X-ray field area on the accuracy of Cyberknife radiotherapy,in order to provide a feasible method for achieving patient protection optimization.Methods Firstly,the spine-tracking,fiducial tracking and lung-tracking radiotherapy plans were formulated for the simulation phantom,and then image-guided full-field localization and position pre-setting were carried out for the simulation phantom,and the spine-tracking,fiducial tracking and lung-tracking radiotherapy plans were executed for the simulation phantom using a reduced lead block field area,respectively.Secondly,the radiotherapy accuracy of different radiotherapy plans was verified by end-to-end(E2E)software using new EBT films of the same batch as the base film.Finally,the changes of the simulation phantom were compared in terms of position pre-presetting error,radiotherapy accuracy and lead block field area.Results The spine-tracking and fiducial tracking radiotherapy plans had the translation errors not higher than 0.1 mm and the rotation errors not higher than 0.1°,which were comparable to the fluctuated conventional Cyberknife image-guided locating;the spine-tracking,fiducial tracking and lung-tracking radiotherapy plans had the lead block field radiotherapy accu-racies being 0.71,0.18 and 1.06 mm,respectively,which met the clinical requirements for Cyberknife radiotherapy;the lead block field areas of the spine-tracking,fiducial tracking and lung-tracking radiotherapy plans were reduced to 19.75%,29.28%and 12.71%of the full field area,respectively,and the efficacy for field area optimization was significant.Conclusion It's feasible to involve a reduced image-guided X-ray field area in Cyberknife radiotherapy,which contributes to optimizing radiation protection for the patients.[Chinese Medical Equipment Journal,2024,45(11):49-53]
4.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.
5.Parallel anchor-supporting sheath and snared wire technique in transcatheter tricuspid valve replacement:a case report
Yan-Xing FANG ; Wen-Zhi PAN ; Da-Xin ZHOU ; Jun-Bo GE
Chinese Journal of Interventional Cardiology 2024;32(8):478-480
Transcatheter tricuspid valve replacement(TTVR)is characterized by minimal invasiveness,rapid recovery,and a significantly lower perioperative mortality rate compared to surgical procedures.It is the preferred treatment for patients with bioprosthetic valve failure following surgical tricuspid valve replacement.However,when the delivery system is relatively bulky,challenges can arise due to the reduced orifice area post-surgery and the constraints imposed by the valve frame.These factors may result in difficulties advancing the delivery system.Additionally,the tortuous right heart pathway and limited support provided by the guide wire further increase the complexity of the procedure.In the present case,the patient experienced bioprosthetic valve failure following surgical tricuspid valve replacement.During TTVR,the advancement of the delivery system across the tricuspid valve encountered difficulties.Our team promptly employed the parallel anchoring-supporting sheath and snared wire(PASS)technique,pioneered at our center.Utilizing a large supporting sheath in conjunction with a snare to secure the tip of a extra-stiff guide wire,we straightened the tortuous pathway,providing additional support to the extra-stiff guide wire.This maneuver successfully facilitated the advancement of the delivery system across the tricuspid valve,offering a practical and effective solution for overcoming intraoperative challenges associated with TTVR.
6.Effects of hypobaric hypoxia intervention on behavioral and hematological indicators in PTSD rats
Bao-Ying SHEN ; Zhi-Xing WANG ; Bo-Wei LI ; Chun-Qi YANG ; Xin SHEN ; Cheng-Cai LAI ; Yue GAO
Chinese Pharmacological Bulletin 2024;40(7):1231-1239
Aim To preliminarily evaluate the effects of hypobaric hypoxia on organism damage in rats with post-traumatic stress disorder(PTSD),with a view to laying a foundation for drug research in plateau PTSD.Methods The rats were randomly divided into four groups,namely,the control(Control)group,the sin-gle-prolonged stress(SPS)group,the hypobaric hy-poxia(HH)group and the single-prolonged stress combined with hypobaric hypoxia(SPS+HH)group.The PTSD model was firstly constructed using the SPS method for rats in the SPS and SPS+HH groups.On the second day,rats in the HH group and SPS+HH group were placed in a low-pressure hypoxia chamber at a simulated altitude of 6000 m for 14 days.General condition,behavior,blood tests,and histomorphology were examined in order to evaluate the damage caused by low pressure hypoxia in PTSD rats.Results The body mass of rats in the SPS+HH group was signifi-cantly reduced;the feces were partly hard and lumpy,and some of them were seen to have high viscosity.Anxiety-like and depression-like behaviors were ob-served in all groups except in the control group,in which hypobaric hypoxia aggravated the behavioral ab-normalities in SPS rats.Rats in both the SPS and SPS+HH groups had coagulation dysfunction and abnor-mally increased blood viscosity,which was significantly abnormal in the SPS+HH group;erythrocytes,hemo-globin,and erythrocyte specific volume in whole blood of rats in the SPS+HH group were significantly in-creased compared with those of rats in the SPS group;and serum TP,LDH and GLU levels were abnormal in rats in the SPS+HH group.Dilated and congested blood vessels were seen in hippocampal tissue,conges-ted central veins were seen in hepatic tissue,and dilat-ed and congested liver sinusoids with mild granuloma-tous degeneration of hepatocytes were seen in rats of the SPS+HH group.Conclusion Hypobaric hypoxia exacerbates depression-like and anxiety-like behaviors in PTSD rats,as well as hematological indices and his-tomorphometric abnormalities in PTSD rats.
7.Predicting executive functioning in patients with post-stroke cognitive impairment
Hongyu ZHOU ; Zhaoxiang MENG ; Xing JIN ; Bo CHEN ; Chi XU ; Xin WANG
Chinese Journal of Physical Medicine and Rehabilitation 2024;46(6):518-523
Objective:To test the expression of miR-146a-5p RNA, interleukin 6 (IL-6) and tumor necrosis factor α (TNF-α) as markers for predicting post-stroke cognitive impairment (PSCI).Methods:Forty cerebral infarction patients who had been followed up after 3 months formed a PSCI group, and another 40 who showed no post-stroke impairment formed the normal (PSCN) group. Forty healthy age-matched people were the AMC group. The executive functioning of each participant was quantified using the digital span test (DST), a Stroop color word test (SCWT), part B of the trail making test (TMT-B), and a semantic fluency test (SFT). Plasma expression levels of miR-146a-5p, IL-6 and TNF-α were also recorded. Receiver operating characteristics (ROC) curves were prepared to analyze the value of the miR-146a-5p, IL-6, TNF-α and Montreal cognitive assessment (MoCA) scores for predicting PSCI.Results:At baseline, the average expression of plasma miR-146a-5p in the PSCI group was significantly lower than in the other groups, with that of the PSCN group significantly higher than the AMC group′s average. Plasma IL-6 content in the PSCI group was significantly higher than in the other two groups on average, with that in the PSCN group significantly higher than in the AMC group. The average TNF-α levels in both the PSCI and PSCN groups were significantly higher than in the AMC group. Three months later, however, the average DST and SFT scores of the PSCI group were significantly lower than those of the other two groups, while TMT-B and stroop interference effects (SIE) times were significantly longer. TMT-B and SIE times in the PSCN group averaged significantly longer than in the AMC group. At baseline, the area under the curve predicting PSCI of plasma miR-146a-5P combined with MoCA scores was 0.90, with a sensitivity of 72.5% and specificity at the optimal critical point of 97.5%.Conclusions:A high level of plasma miR-146a-5p in the acute stage may protect an ACI patient′s cognitive functioning by inhibiting neuroinflammatory responses. Its expression level and the patient′s MoCA score can help to predict PSCI.
8.Study on improving the photostability of nifedipine by crystal engineering
Xin MENG ; Yao ZOU ; Mei-ju LIU ; Cheng XING ; Ning-bo GONG ; Yang LÜ
Acta Pharmaceutica Sinica 2024;59(12):3374-3378
In order to improve the poor photostability of nifedipine, this study designed a cocrystal based on the principles of crystal engineering and prepared nifedipine-imidazole cocrystal by suspension method. The new cocrystal was characterized by powder X-ray diffraction (PXRD), differential scanning calorimetry (DSC), thermogravimetric analysis (TG) and infrared spectroscopy (IR) to confirm the formation of the cocrystal. The photostability of nifedipine and its cocrystal was measured by powder X-ray diffraction and high-performance liquid chromatography (HPLC). The results showed that the nifedipine-imidazole cocrystal improved the photostability of nifedipine to a certain extent. This study provides guidance for the development of nifedipine cocrystals and the improvement of its druggability.
9.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
BACKGROUND:
LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
METHODS:
We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
RESULTS:
On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
CONCLUSION:
LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04563936.
Humans
;
Male
;
Antineoplastic Agents, Hormonal/therapeutic use*
;
East Asian People
;
Gonadotropin-Releasing Hormone/agonists*
;
Goserelin/therapeutic use*
;
Prostate-Specific Antigen
;
Prostatic Neoplasms/drug therapy*
;
Testosterone
10.Evaluation of Extrathyroidal Extension of Papillary Thyroid Microcarcinoma With Three-Dimensional Tomographic Ultrasound Imaging.
Ru-Yu LIU ; Yu-Xin JIANG ; Rui-Na ZHAO ; Xing-Jian LAI ; Chuan-Ying-Zi LU ; Lu-Ying GAO ; Ying WANG ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):361-365
Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.
Humans
;
Thyroid Nodule
;
Thyroid Neoplasms/diagnosis*
;
Carcinoma, Papillary/pathology*
;
Ultrasonography/methods*
;
Retrospective Studies

Result Analysis
Print
Save
E-mail