1.Flow diverters in aneurysms beyond the circle of Willis: a multicenter retrospective study
Xin FENG ; Chi HUANG ; Runze GE ; Chao PENG ; Zongduo GUO ; Shixing SU ; Xin ZHANG ; Xifeng LI ; Aihua LIU ; Chuanzhi DUAN
Chinese Journal of Neuromedicine 2025;24(1):8-15
Objective:To investigate the efficacy and safety of off-label use of flow diverters (FDs) in aneurysms beyond the circle of Willis.Methods:Seventy-one patients with aneurysms beyond the circle of Willis treated with FDs from January 2016 to September 2023 at Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital of Southern Medical University), Department of Neurosurgery (Guangdong Provincial People's Hospital), Department of Neurosurgery (First Affiliated Hospital of Chongqing Medical University), and Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University) were selected. The clinical and imaging data of these patients were analyzed retrospectively, and the clinical characteristics, aneurysm characteristics, endovascular treatments, perioperative complications, and clinical and imaging follow-up results were summarized and analyzed.Results:Among the 71 patients, 22 (31.0%) had ischemic stroke history and 43 (60.6%) had hypertension history. A total of 76 aneurysms were found, including 5 aneurysms (6.6%) at the anterior communicating artery, 10 (13.2%) at the anterior cerebral artery, 53 (69.7%) at the middle cerebral artery, and 8 (10.5%) at the posterior cerebral artery. The median aneurysm size (Inter Quartile Range) was 5.65 (3.63, 10.12) mm, and mean diameter of the parent artery was (2.70±0.57) mm. A total of 80 FDs were used, including 38 (47.5%) Pipeline embolization devices and 42 (52.5%) Tubridge embolization devices; the implantation success rate was 98.8% (79/80). Seven patients (9.9%) had perioperative complications, of which 2 (2.8%) were permanent (1 patient with visual field defect and 1 patient with intracranial hemorrhage). Seventy-one patients had clinical follow-up for (19.73±11.90) months, of which 68 patients (95.8%) had good outcome (modified Rankin scale score of 0-2), 10 patients (14.1%) had ischemic complications, and one patient (1.4%) had hemorrhage complications. Sixty-seven aneurysms (88.2%) underwent angiographic follow-up for 7 (6-12) months, of which 44 aneurysms (65.7%) were completely occluded and 10 (14.9%) had in-stent stenosis.Conclusion:The results of this study preliminarily confirm that off-label use of FDs is relatively safe and effective in aneurysms beyond the circle of Willis.
2.Efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms: a multicenter retrospective study
Xiaowen ZHANG ; Jing LI ; Xifeng LI ; Chuanzhi DUAN ; Aihua LIU ; Huaizhang SHI ; Haowen XU ; Nan MA ; Zhiqiang YAO ; Feng FAN ; Chao LIU ; Jinyi LI ; Hailong ZHONG ; Mengyan FAN ; Jiaxin WAN ; Rijin LIN ; Huixiang LIU ; Jiamei ZHANG ; Xin ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(1):16-22
Objective:To evaluate the efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms.Methods:One hundred and seventeen patients with wide-necked intracranial aneurysms treated with intrasaccular flow disruptor were collected from Department of Neurointervention (First Affiliated Hospital of Zhengzhou University), Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University), Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital, Southern Medical University), and Department of Neurosurgery (First Affiliated Hospital of Harbin Medical University) from August 2022 to March 2024. Raymond-Roy Occlusion Classification (RROC) was employed to evaluate aneurysm embolization immediately after procedure; cranial CT or MRI within 48 hours of embolization were performed to identify any new intracranial hemorrhage, subarachnoid hemorrhage, or new symptomatic cerebral infarction related to the intracranial aneurysms. Modified Rankin Scale (mRS) was used to assess the neurological function at discharge. Imaging follow-up and outpatient follow-up were performed at 6 months after embolization to evaluate the aneurysm occlusion degree and complications.Results:A total of 117 intrasaccular flow disruptors were implanted in 117 patients, with a technical success rate of 100%; 115 patients (98.3%) enjoyed successful one-time release of their disruptors, and 2 patients (1.7%) required retrieval and redirection of the disruptors before second successful attempt. Flow disruptor plus stent was performed in 13 patients (11.1%). Immediately after procedure, RROC grading I was noted in 3 patients, grading II in 51 patients and grading III in 63 patients. Cranial CT or MRI within 48 hours of embolization indicated no new intracranial hemorrhage, subarachnoid hemorrhage, or symptomatic cerebral infarction related to the intracranial aneurysms. All patients had mRS score of 0 at discharge. Eighty-three patients completed a 6-month follow-up (RROC grading I in 41 patients, grading II in 33 patients and grading III in 9 patients), without ischemic or hemorrhagic adverse events.Conclusion:The results of this study preliminarily suggest that intrasaccular flow disruptor is effective and safe in wide-necked intracranial aneurysms.
3.Analysis of 12 Pathogens in surveillance cases of febrile respiratory syndrome in Daxing district of Beijing City from 2018 to 2023
Jinfeng TANG ; Hong LEI ; Meichen LIU ; Qiuling LI ; Tian LI ; Xifeng WANG ; Yadi GAN ; Daitao ZHANG
Chinese Journal of Preventive Medicine 2025;59(4):478-483
A total of 1 557 cases were included in the Febrile Respiratory Syndrome (FRS) surveillance conducted in Daxing District between 2018 and 2023. Twelve respiratory pathogens were investigated: human influenza virus (HIFV), human respiratory syncytial virus (HRSV), human parainfluenza virus (HPIV), human rhinovirus (HRV), human enterovirus (HEV), human adenovirus (HadV), human metapneumovirus (HMPV), human bocavirus (HBoV), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (CP), human coronavirus (HCoV), and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Results demonstrated an overall pathogen detection rate of 25.31% (394/1 557), with descending prevalence as follows: HIFV, SARS-CoV-2, HRV, HPIV, MP, HCoV, HRSV, HEV, HMPV, HadV, HBoV, and CP. Temporal analysis revealed detection rates of 26.98% (150/556) for 2018-2019, 15.81% (95/601) for 2020-2022, and 37.25% (149/400) for 2023, showing statistically significant interannual variation (χ2=59.703, P<0.001). Compared with 2018-2019, 2023 exhibited significantly elevated detection rates for HIFV and HMPV ( P<0.05), while HRV, MP, HEV, and HBoV demonstrated significantly reduced rates ( P<0.05). Age-stratified analysis identified HIFV, HRSV, and HadV as the predominant pathogens in individuals aged <15 years, whereas SARS-CoV-2, HIFV, and HRV predominated in those aged ≥60 years.
4.Interpreting the Key Differences between CHS-DRG 2.0 and 1.1 from a Clinical Management Perspective
Xinbing LÜ ; Chunhua PAN ; Xifeng SHEN ; Baoyan ZHANG ; Xiang LONG ; Xiaokun GENG ; Yingfeng WU
Chinese Health Economics 2025;44(4):50-55
Objective:Interpret the key differences between the China Health-care Security Diagnosis Related Groups(CHS-DRG)2.0 and CHS-DRG 1.1,and provide reference for optimizing management strategies in medical institutions.Methods:Text analysis was used to import the CHS-DRG 2.0 and 1.1 grouping scheme dictionary data into the SQL database in a structured table format using SQL Server 2014.The key differences between the two schemes in grouping structure,grouping rules,grouping results,and other aspects were identified.Results:CHS-DRG 2.0 version added 26 groups,deleted 3 groups,and refined 10 groups into 20 groups for 14 clinical specialties at the ADRG level compared to CHS-DRG 1.1.Some group codes,names,and grouping rules were adjusted;Adjusted some grouping conditions and grouping results at the DRG level.Conclusion:CHS-DRG 2.0 version has improved grouping efficiency compared to CHS-DRG 1.1,solved some clinical bottleneck problems,and standardized the role of clinical diagnosis in grouping from the perspective of resource consumption.However,it has not completely solved the grouping problems of multi disease co treatment,multi disease treatment,and combined surgery.The adjustment of DRG weights and rates,the follow-up of related supporting policy reforms,and the negative effects of DRG will still pose challenges for medical institutions.
5.Flow diverters in aneurysms beyond the circle of Willis: a multicenter retrospective study
Xin FENG ; Chi HUANG ; Runze GE ; Chao PENG ; Zongduo GUO ; Shixing SU ; Xin ZHANG ; Xifeng LI ; Aihua LIU ; Chuanzhi DUAN
Chinese Journal of Neuromedicine 2025;24(1):8-15
Objective:To investigate the efficacy and safety of off-label use of flow diverters (FDs) in aneurysms beyond the circle of Willis.Methods:Seventy-one patients with aneurysms beyond the circle of Willis treated with FDs from January 2016 to September 2023 at Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital of Southern Medical University), Department of Neurosurgery (Guangdong Provincial People's Hospital), Department of Neurosurgery (First Affiliated Hospital of Chongqing Medical University), and Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University) were selected. The clinical and imaging data of these patients were analyzed retrospectively, and the clinical characteristics, aneurysm characteristics, endovascular treatments, perioperative complications, and clinical and imaging follow-up results were summarized and analyzed.Results:Among the 71 patients, 22 (31.0%) had ischemic stroke history and 43 (60.6%) had hypertension history. A total of 76 aneurysms were found, including 5 aneurysms (6.6%) at the anterior communicating artery, 10 (13.2%) at the anterior cerebral artery, 53 (69.7%) at the middle cerebral artery, and 8 (10.5%) at the posterior cerebral artery. The median aneurysm size (Inter Quartile Range) was 5.65 (3.63, 10.12) mm, and mean diameter of the parent artery was (2.70±0.57) mm. A total of 80 FDs were used, including 38 (47.5%) Pipeline embolization devices and 42 (52.5%) Tubridge embolization devices; the implantation success rate was 98.8% (79/80). Seven patients (9.9%) had perioperative complications, of which 2 (2.8%) were permanent (1 patient with visual field defect and 1 patient with intracranial hemorrhage). Seventy-one patients had clinical follow-up for (19.73±11.90) months, of which 68 patients (95.8%) had good outcome (modified Rankin scale score of 0-2), 10 patients (14.1%) had ischemic complications, and one patient (1.4%) had hemorrhage complications. Sixty-seven aneurysms (88.2%) underwent angiographic follow-up for 7 (6-12) months, of which 44 aneurysms (65.7%) were completely occluded and 10 (14.9%) had in-stent stenosis.Conclusion:The results of this study preliminarily confirm that off-label use of FDs is relatively safe and effective in aneurysms beyond the circle of Willis.
6.Efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms: a multicenter retrospective study
Xiaowen ZHANG ; Jing LI ; Xifeng LI ; Chuanzhi DUAN ; Aihua LIU ; Huaizhang SHI ; Haowen XU ; Nan MA ; Zhiqiang YAO ; Feng FAN ; Chao LIU ; Jinyi LI ; Hailong ZHONG ; Mengyan FAN ; Jiaxin WAN ; Rijin LIN ; Huixiang LIU ; Jiamei ZHANG ; Xin ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(1):16-22
Objective:To evaluate the efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms.Methods:One hundred and seventeen patients with wide-necked intracranial aneurysms treated with intrasaccular flow disruptor were collected from Department of Neurointervention (First Affiliated Hospital of Zhengzhou University), Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University), Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital, Southern Medical University), and Department of Neurosurgery (First Affiliated Hospital of Harbin Medical University) from August 2022 to March 2024. Raymond-Roy Occlusion Classification (RROC) was employed to evaluate aneurysm embolization immediately after procedure; cranial CT or MRI within 48 hours of embolization were performed to identify any new intracranial hemorrhage, subarachnoid hemorrhage, or new symptomatic cerebral infarction related to the intracranial aneurysms. Modified Rankin Scale (mRS) was used to assess the neurological function at discharge. Imaging follow-up and outpatient follow-up were performed at 6 months after embolization to evaluate the aneurysm occlusion degree and complications.Results:A total of 117 intrasaccular flow disruptors were implanted in 117 patients, with a technical success rate of 100%; 115 patients (98.3%) enjoyed successful one-time release of their disruptors, and 2 patients (1.7%) required retrieval and redirection of the disruptors before second successful attempt. Flow disruptor plus stent was performed in 13 patients (11.1%). Immediately after procedure, RROC grading I was noted in 3 patients, grading II in 51 patients and grading III in 63 patients. Cranial CT or MRI within 48 hours of embolization indicated no new intracranial hemorrhage, subarachnoid hemorrhage, or symptomatic cerebral infarction related to the intracranial aneurysms. All patients had mRS score of 0 at discharge. Eighty-three patients completed a 6-month follow-up (RROC grading I in 41 patients, grading II in 33 patients and grading III in 9 patients), without ischemic or hemorrhagic adverse events.Conclusion:The results of this study preliminarily suggest that intrasaccular flow disruptor is effective and safe in wide-necked intracranial aneurysms.
7.Recent advances in mechanisms, evaluations and treatments of in-stent stenosis following flow diverter implantation from hemodynamics perspective
Zhikun JIA ; Mengshi HUANG ; Xifeng LI ; Yanchao LIU ; Shixing SU ; Chuanzhi DUAN ; Xin ZHANG
Chinese Journal of Neuromedicine 2025;24(5):514-518
Flow diverter (FD) devices have gradually become the mainstream approach for interventional treatment of intracranial aneurysms. In-stent stenosis (ISS) is a common complication after FD implantation, which can lead to ischemic events and affect the prognosis of patients. Current studies have shown that ISS occurrence is closely related to hemodynamic changes. From the perspective of hemodynamics, this article reviews the research progress of mechanisms, evaluation methods and treatments of ISS after FD implantation, in order to provide reference for clinical practice.
8.Safety and efficacy of PED Shield in intracranial unruptured saccular aneurysms
Runze GE ; Xin FENG ; Xueyan DENG ; Zehui XIE ; Can LI ; Shuyin LIANG ; Shixing SU ; Xin ZHANG ; Xifeng LI ; Chuanzhi DUAN
Chinese Journal of Neuromedicine 2025;24(7):649-655
Objective:To investigate the safety and efficacy of Pipeline embolization device (PED) Shield in intracranial unruptured saccular aneurysms.Methods:This is a retrospective cohort study; 124 patients with intracranial unruptured saccular aneurysms treated with PED Shield at Department of Cerebrovascular Surgery, Neurosurgery Center, Zhujiang Hospital, Southern Medical University from July 2023 to October 2024 were enrolled. Intraoperative device-related complications and occurrence of hemorrhagic and ischemic complications within 30 days of the procedure were recorded. The clinical results and imaging results (degrees of stent patency and aneurysm occlusion rate) 6 months after follow-up were statistically analyzed. Modified Rankin scale (mRS) score>2 was defined as poor prognosis in clinical follow-up, and grade D according to O'Kelly Marotta (OKM) classification was considered as complete aneurysm occlusion in imaging follow-up.Results:Eighty-seven females and 37 males, aged (56.44±12.17) years (ranging from 27 to 80 years) were enrolled, with a maximum aneurysm diameter of 5.12 (3.73, 7.24) mm. Among the 124 patients, incidence of intraoperative instrument-related complications was 6.5% (8/124); and within 30 days of the procedure, incidence of ischemic complications was 4.8% (6/124) and that of hemorrhagic complications was 1.6% (2/124). Eighty-four patients had a 6-month clinical follow-up, with 1 patient (1.2%) having poor prognosis. Eighty-four patients (67.7%) completed a 6-month imaging follow-up: complete occlusion rate of aneurysms was 82.1% (69/84), incidence of in-stent stenosis (stenosis degree ≥25%) was 4.8% (4/84), and no symptomatic in-stent stenosis was found.Conclusion:Result of this study shows that PED Shield may be an effective and safe clinical option for intracranial unruptured saccular aneurysms.
9.Analysis of relevant factors for rupture of basilar tip aneurysms
Runze GE ; Xin FENG ; Chi HUANG ; Mengshi HUANG ; Jiwan HUANG ; Can LI ; Shixing SU ; Xin ZHANG ; Xifeng LI ; Chuanzhi DUAN
Chinese Journal of Surgery 2025;63(3):227-232
Objective:To investigate the relevant factors for rupture of basilar tip aneurysms.Methods:This is a retrospective cohort study. Patients who underwent cerebrovascular digital subtraction angiography at Department of Cerebrovascular Disease Surgery,Zhujiang Hospital of Southern Medical University from July 2008 to February 2023 and were confirmed to have basilar tip aneurysms were retrospectively analyzed. There were 45 males and 56 females, aged (57.5±10.2) years (range: 36 to 76 years); the maximum diameter of the basilar tip aneurysm ( M(IQR)) was 6.85 (5.79) mm (range: 1.28 to 27.48 mm). Finally, 101 basilar tip aneurysms were included, and divided into two groups based on whether the basilar tip aneurysm ruptured or not. There were 37 cases (36.6%) in the ruptured group and 64 cases (63.4%) in the unruptured group. Data were analyzed using independent t-test, Mann-Whitney U test, chi-square test, or Fisher′s exact test, as appropriate, and predictive factors for rupture of basilar tip aneurysms were explored by Logistic regression analysis. Variance inflation factors was used for analysis of collinearity. Results:The univariate results showed statistically significant differences between the ruptured and unruptured groups in terms of aneurysm neck width, basilar artery diameter, mean diameter of the parental artery, the ratio of neck width to parent artery diameter, aneurysm width and maximum diameter of the aneurysm (all P<0.05). In multivariate analysis, basilar artery diameter ( OR=0.347, 95% CI:0.176 to 0.687, P=0.002), and NRP ( OR=0.366, 95% CI:0.192 to 0.696, P=0.002) were predictive factors for rupture of aneurysms occurring at the basilar tip. There was no multiple covariance between NRP and basilar artery diameter in the analysis of covariance (VIF=1). Conclusion:Smaller basilar artery diameter and smaller NRP are relevant factors for rupture of basilar tip aneurysms.
10.Effects of Hermetia illucens larvae meal on immune function,intestinal morphol-ogy and microflora of Sichuan white geese
Dezhi ZHANG ; Xifeng LI ; Fuxing GUI ; Chonghua ZHONG ; Huan HUANG ; Pingrui YANG ; Yongfeng HAO ; Liting CAO
Chinese Journal of Veterinary Science 2025;45(2):369-378
This experiment was conducted to study the effects of replacing feed protein by Herme-tia illucens larvae meal on immune function,intestinal morphology and microflora of Sichuan white geese.A total of 64 healthy 1-day-old Sichuan white geese were randomly allocated into 4 groups with 4 replicates in each group and 4 geese in each replicate,namely the control group,the 2%HILM,4%HILM and 8%HILM groups fed diets contained 0%,2%,4%and 8%of HILM,re-spectively.The experimental period was 40 days.The results showed that compared with the con-trol group,8%HILM increased the levels of serum IgG1,IgG2a and complement C3,and the difference was statistically significant(P<0.01).4%HILM significantly increased the expression level of CD4(P<0.05),and 8%HILM significantly increased the expression level of IL-10(P<0.05).The ratio of villus length to crypt depth(VH/CD)in the jejunum and ileum in 4%HILM group was significantly increased(P<0.05).The SIgA level of jejunum was significantly increased in all HILM replacement groups(P>0.05).The abundance of Bacteroides in 4%HILM group were extremely significantly increased(P<0.01),and the abundance of Bilophila and Bilophila wadsworthia were significantly decreased in all HILM replacement groups(P<0.05).In conclu-sion,HILM can enhance the immune function of Sichuan white geese,improve the intestinal mor-phology of jejunum and ileum,enhance the local mucosal immunity of jejunum,increase the abun-dance of beneficial bacteria in cecum and decrease the abundance of harmful bacteria in cecum,and protect intestinal health.

Result Analysis
Print
Save
E-mail