1.Accuracy Assessment of Cone-Beam CT Images for Pelvic Tumor Dose Calculation.
Bao LI ; Yongzhong CHEN ; Jun JIN ; Longjun YAN ; Xiaoyong WANG
Chinese Journal of Medical Instrumentation 2025;49(3):302-307
OBJECTIVE:
To evaluate the feasibility and accuracy of cone-beam CT (CBCT) images for radiotherapy dose calculation in pelvic tumors.
METHODS:
An improved volumetric density coverage method was used to establish CT value-relative electron density (RED) curves for CBCT images. The planning CT plans were transferred to the CBCT images, and the constructed density curves were applied to calculate doses for CBCT plans while maintaining the optimization parameters unchanged. Dose calculation deviations between the two plans were analyzed.
RESULTS:
The mean differences in dosimetric parameters for the target volume and organs at risk (OAR) between the two plans were less than 1% and 1.5%, respectively. The target conformity index (CI), homogeneity index (HI), and gamma passing rates were highly consistent, with no statistically significant differences.
CONCLUSION
CBCT images corrected by this method can be used for dose calculation in pelvic tumor radiotherapy planning.
Cone-Beam Computed Tomography/methods*
;
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Radiotherapy Dosage
;
Pelvic Neoplasms/diagnostic imaging*
2.Guidelines on the Technical Plan for Emergency Health Response to Acute Gelsemium Poisoning
Jiaxin JIANG ; Ruibo MENG ; Zhongxiang GAO ; Rongzong LI ; Weifeng RONG ; Weihui LIANG ; Shibiao SU ; Jian HUANG ; Cheng JIN ; LlU XIAOYONG
China Occupational Medicine 2025;52(2):203-206
Acute Gelsemium poisoning is a systemic disease primarily affecting the central nervous system and respiratory symptoms caused by the ingestion of a substantial amount of Gelsemium within a short period. It manifests as sudden onset and rapid progression, primarily caused by accidental ingestion due to misidentification, and posing significant health risks. The compilation of the Technical Plan for Emergency Health Response to Acute Gelsemium Poisoning describes in detail the specialized practice and technical requirements in the process of handling acute Gelsemium poisoning, including accident investigation and management, laboratory testing and identification, in-hospital treatment, and health monitoring. The guidelines clarify key procedures and requirements such as personal protection, investigation elements, etiology determination, medical rescue, and health education. The key to acute Gelsemium poisoning investigation lies in promptly identifying the toxin through exposure history, clinical manifestations, and sample testing. Because there is no specific antidote for Gelsemium poisoning, immediate removal from exposure, rapid elimination of the toxin, and respiratory monitoring are critical on-site rescue measures. Visual identification of food or herbal materials, followed by laboratory testing to determine Gelsemium alkaloids in samples is a rapid effective screening method. These guidelines offer a scientific, objective, and practical framework to support effective emergency responses to acute Gelsemium poisoning incidences.
3.Analysis of efficacy and prognostic factors of fractionated stereotactic radiotherapy (FSRT) for brain metastases in 52 breast cancer patients
Hu CHEN ; Yutong TAN ; Yasha MU ; Xiaoyong XIANG ; Yuexin YANG ; Lingling FENG ; Xiaoye SU ; Wenjue ZHANG ; Gang XU ; Jing JIN
Chinese Journal of Radiation Oncology 2025;34(3):256-264
Objective:To analyze the efficacy and prognostic factors of fractionated stereotactic radiotherapy (FSRT) for patients with breast cancer brain metastases (BCBM).Methods:Medical records and follow-up data of BCBM patients who underwent FSRT in Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center and Shenzhen People's Hospital from August 2019 to May 2023 were collected. The R Studio platform of the R version 4.2.1 statistical software was applied to analyze patients' baseline characteristics, 1- and 2-year local brain control (LBC), overall survival (OS) and distant brain control (DBC) and corresponding median failure-free survival, draw survival curve using Kaplan-Meier method. Prognostic factors were screened by univariate analysis and multivariate analysis (Cox regression).Results:Cumulatively, 52 patients (163 metastases in total) had a median survival follow-up of 22.1 months, 83% were<60 years old. Molecular typing: 13 cases (25%) were positive for human epidermal growth factor receptor 2 (HER2+) / hormone receptor negative (HR-), 2 cases (4%) were luminal A, 26 cases (50%) were luminal B, and 11 cases (21%) were triple negative. The median number of brain metastases was 2 (range: 1 - 17). Follow-up outcomes: the median OS was 34.0 months, with 1- and 2-year OS rates of 85.6% and 65.4%, respectively; the median LBC was 20.6 months, with 1- and 2-year LBC rates of 79.2% and 45.2%, respectively; and the median DBC was 10.3 months, with 1- and 2-year DBC rates of 46.7% and 28.9%, respectively. During follow-up, 13 patients underwent salvage local therapy (10 FSRT); 5 developed radiation necrosis (1 symptomatic). Prognostic factor analysis: absence of extracranial organ metastases (compared with ≥3) was a protective factor for OS, P<0.05. For LBC, fewer (1 - 2) extracranial organ metastases (compared with ≥3), and single brain metastasis (compared with ≥2) were favorable prognostic factors , while N 3 staging upon initial diagnosis was a poor prognostic factor (all P<0.05). For DBC, brain metastasis after surgery was a good prognostic factor, while complicated with lung metastasis and asymptomatic brain metastasis at the first diagnosis were poor prognostic factors (all P<0.05). Conclusions:FSRT yields relatively good LBC and poor DBC for BCBM patients. A certain percentage of patients require salvage FSRT during follow-up, but OS is maintained acceptable and the radiation necrosis is tolerable. Among the prognostic factors, the absence of extracranial metastatic organs is a good prognostic factor for OS; patients with single brain metastasis, fewer extracranial metastatic organs, and non-N 3 staging upon initial diagnosis can obtain better LBC after FSRT.
4.Monitoring and analysis of internal exposure of 131I treatment staff in nuclear medicine department in Jiangsu province from 2021 to 2024
Xiaodong SHI ; Zihao ZHANG ; Xiaoyong YANG ; Jin WANG ; Wei CHEN ; Jiayi MA
Chinese Journal of Radiological Medicine and Protection 2025;45(6):512-518
Objective:To understand the basic situation of occupational internal exposure to 131I among nuclear medicine staff in Jiangsu province, and to analyze the relevant factors that contribute to the formation of internal exposure. Methods:A four-year external direct measurement of thyroid organ counting was conducted on nuclear medicine staff who underwent 131I treatment in Jiangsu province. The result were statistically analyzed, and the effective dose of accumulated internal exposure was estimated. The relationship between the detection rate of internal exposure and 10 possible factors was analyzed. Results:A total of 847 person-times were monitored during the monitoring period, of which 345 person-times were detected for 131I, with a detection rate of 40.7%. The highest individual monitoring result for internal exposure was 24.83 kBq, with an average value of 77.3 Bq and a median of 28.3 Bq among the detected individuals. The average committed effective dose of internal exposure for staff was 0.201 mSv, with a median of 0.074 mSv among the detected individuals. Conclusions:There is statistically significant difference in the detection rate of individual doses of internal exposure among nuclear medicine staff in each year. It has been observed that the main factors related to the detection rate are age, hospital grade, job position, location, whether there is an automatic dispensing operation, operating method, exposure level and length of exposure. Sufficient attention should be given to the situation of internal exposure, and further effective monitoring should be conducted on all such staff members.
5.Preliminary study on occupational internal exposure to 131I among nuclear medicine workers in a hospital in Nanjing
Jiayi MA ; Zihao ZHANG ; Yuanyuan ZHOU ; Qun CHEN ; Xiaoyong YANG ; Jin WANG ; Xiaodong SHI
Chinese Journal of Radiological Medicine and Protection 2025;45(10):1009-1014
Objective:To investigate the basic situation of occupational internal exposure to 131I among staff in the nuclear medicine department. Methods:Direct in- vitro measurements of thyroid doses from internal exposure were conducted for six months on 36 staff members of a hospital′s nuclear medicine department in Nanjing using the ORTEC Detective-100 portable high-purity germanium (HPGe) spectrometer. The cumulative effective doses were estimated, and the distribution of internal doses and their relationship with job type and external doses were analyzed. Results:During the monitoring period, a total of 203 monitorings were made. Of the monitoring result, 85.7% were below the recording level. Of the result exceeding the recording level, 12.8% were below the investigation level, while 1.5% exceeded the investigation level. The highest personal internal dose during the monitoring period was 2.54 mSv, the lowest was 0.015 mSv, and the median was 0.094 mSv.Conclusions:During the monitoring period, 14.3% of the monitored staff had result above the recorded levels. In the working environment of radionuclide treatment, there is no significant difference in the internal dose received between doctors, nurses, technicians, or other relevant personnel.
6.Monitoring and analysis of internal exposure of 131I treatment staff in nuclear medicine department in Jiangsu province from 2021 to 2024
Xiaodong SHI ; Zihao ZHANG ; Xiaoyong YANG ; Jin WANG ; Wei CHEN ; Jiayi MA
Chinese Journal of Radiological Medicine and Protection 2025;45(6):512-518
Objective:To understand the basic situation of occupational internal exposure to 131I among nuclear medicine staff in Jiangsu province, and to analyze the relevant factors that contribute to the formation of internal exposure. Methods:A four-year external direct measurement of thyroid organ counting was conducted on nuclear medicine staff who underwent 131I treatment in Jiangsu province. The result were statistically analyzed, and the effective dose of accumulated internal exposure was estimated. The relationship between the detection rate of internal exposure and 10 possible factors was analyzed. Results:A total of 847 person-times were monitored during the monitoring period, of which 345 person-times were detected for 131I, with a detection rate of 40.7%. The highest individual monitoring result for internal exposure was 24.83 kBq, with an average value of 77.3 Bq and a median of 28.3 Bq among the detected individuals. The average committed effective dose of internal exposure for staff was 0.201 mSv, with a median of 0.074 mSv among the detected individuals. Conclusions:There is statistically significant difference in the detection rate of individual doses of internal exposure among nuclear medicine staff in each year. It has been observed that the main factors related to the detection rate are age, hospital grade, job position, location, whether there is an automatic dispensing operation, operating method, exposure level and length of exposure. Sufficient attention should be given to the situation of internal exposure, and further effective monitoring should be conducted on all such staff members.
7.Preliminary study on occupational internal exposure to 131I among nuclear medicine workers in a hospital in Nanjing
Jiayi MA ; Zihao ZHANG ; Yuanyuan ZHOU ; Qun CHEN ; Xiaoyong YANG ; Jin WANG ; Xiaodong SHI
Chinese Journal of Radiological Medicine and Protection 2025;45(10):1009-1014
Objective:To investigate the basic situation of occupational internal exposure to 131I among staff in the nuclear medicine department. Methods:Direct in- vitro measurements of thyroid doses from internal exposure were conducted for six months on 36 staff members of a hospital′s nuclear medicine department in Nanjing using the ORTEC Detective-100 portable high-purity germanium (HPGe) spectrometer. The cumulative effective doses were estimated, and the distribution of internal doses and their relationship with job type and external doses were analyzed. Results:During the monitoring period, a total of 203 monitorings were made. Of the monitoring result, 85.7% were below the recording level. Of the result exceeding the recording level, 12.8% were below the investigation level, while 1.5% exceeded the investigation level. The highest personal internal dose during the monitoring period was 2.54 mSv, the lowest was 0.015 mSv, and the median was 0.094 mSv.Conclusions:During the monitoring period, 14.3% of the monitored staff had result above the recorded levels. In the working environment of radionuclide treatment, there is no significant difference in the internal dose received between doctors, nurses, technicians, or other relevant personnel.
8.Analysis of efficacy and prognostic factors of fractionated stereotactic radiotherapy (FSRT) for brain metastases in 52 breast cancer patients
Hu CHEN ; Yutong TAN ; Yasha MU ; Xiaoyong XIANG ; Yuexin YANG ; Lingling FENG ; Xiaoye SU ; Wenjue ZHANG ; Gang XU ; Jing JIN
Chinese Journal of Radiation Oncology 2025;34(3):256-264
Objective:To analyze the efficacy and prognostic factors of fractionated stereotactic radiotherapy (FSRT) for patients with breast cancer brain metastases (BCBM).Methods:Medical records and follow-up data of BCBM patients who underwent FSRT in Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center and Shenzhen People's Hospital from August 2019 to May 2023 were collected. The R Studio platform of the R version 4.2.1 statistical software was applied to analyze patients' baseline characteristics, 1- and 2-year local brain control (LBC), overall survival (OS) and distant brain control (DBC) and corresponding median failure-free survival, draw survival curve using Kaplan-Meier method. Prognostic factors were screened by univariate analysis and multivariate analysis (Cox regression).Results:Cumulatively, 52 patients (163 metastases in total) had a median survival follow-up of 22.1 months, 83% were<60 years old. Molecular typing: 13 cases (25%) were positive for human epidermal growth factor receptor 2 (HER2+) / hormone receptor negative (HR-), 2 cases (4%) were luminal A, 26 cases (50%) were luminal B, and 11 cases (21%) were triple negative. The median number of brain metastases was 2 (range: 1 - 17). Follow-up outcomes: the median OS was 34.0 months, with 1- and 2-year OS rates of 85.6% and 65.4%, respectively; the median LBC was 20.6 months, with 1- and 2-year LBC rates of 79.2% and 45.2%, respectively; and the median DBC was 10.3 months, with 1- and 2-year DBC rates of 46.7% and 28.9%, respectively. During follow-up, 13 patients underwent salvage local therapy (10 FSRT); 5 developed radiation necrosis (1 symptomatic). Prognostic factor analysis: absence of extracranial organ metastases (compared with ≥3) was a protective factor for OS, P<0.05. For LBC, fewer (1 - 2) extracranial organ metastases (compared with ≥3), and single brain metastasis (compared with ≥2) were favorable prognostic factors , while N 3 staging upon initial diagnosis was a poor prognostic factor (all P<0.05). For DBC, brain metastasis after surgery was a good prognostic factor, while complicated with lung metastasis and asymptomatic brain metastasis at the first diagnosis were poor prognostic factors (all P<0.05). Conclusions:FSRT yields relatively good LBC and poor DBC for BCBM patients. A certain percentage of patients require salvage FSRT during follow-up, but OS is maintained acceptable and the radiation necrosis is tolerable. Among the prognostic factors, the absence of extracranial metastatic organs is a good prognostic factor for OS; patients with single brain metastasis, fewer extracranial metastatic organs, and non-N 3 staging upon initial diagnosis can obtain better LBC after FSRT.
9.Establishment of a Method for Galvanic Vestibular Stimulation-vestibular Evoked Myogenic Potentials in Healthy Children
Zichen CHEN ; Juan HU ; Feiyun CHEN ; Hui YANG ; Yanfei CHEN ; Tingting XUE ; Fangyuan YANG ; Yuzhong ZHANG ; Qiong WU ; Yulian JIN ; Xiaoyong REN ; Qing ZHANG
Journal of Audiology and Speech Pathology 2024;32(2):100-106
Objective To establish the methods of galvanic vestibular stimulation-vestibular evoked myogenic potentials(GVS-VEMPs)in healthy children and to obtain the normal value of GVS-cVEMP and GVS-oVEMP in these children in China.Methods Twenty(3~14 years)healthy children and 24 healthy adults(18~30 years)were enrolled for conventional examinations of GVS-cVEMP and GVS-oVEMP.Using the galvanic stimulation in-tensity under 3 mA/1 ms for children and 5 mA/1 ms for adults.The characteristics of elicitation and parameter re-sults of GVS-cVEMP and GVS-oVEMP in children and adults,as well as the pain scores and the elicitation of differ-ent stimulus intensities in the two age groups were recorded.Results The elicitation of GVS-cVEMP and GVS-oVEMP were both 100.0%in children and adult groups.The p1 latency,n1 latency and p1-n1 interval latency of GVS-cVEMP were 10.46±1.84 ms,16.98±2.12 ms and 6.52±1.42 ms respectively in children group,the n1 la-tency and p1-n1 interval latency were significantly shorter than the adult group(P<0.05).The n1 latency,p1 la-tency and p1-n1 interval latency of GVS-oVEMP were 8.87±1.40 ms,12.25±1.80 ms and 3.39±1.07 ms re-spectively in children group with no significant difference between the two groups.The thresholds of GVS-cVEMP and GVS-oVEMP in children group were significantly lower than adult group(P<0.01),but no differences were found in adult group regarding on the amplitude and interaural amplitude asymmetry ratio.In addition,with the in-crease of the intensity of galvanic stimulation,the correlation between pain scores and the elicitation rates of GVS-cVEMP and GVS-oVEMP also increased.Conclusion Using appropriate stimulus intensity and recording methods,GVS-cVEMP and GVS-oVEMP could be successfully assessed and detected in healthy children over 3 years old and adolescents.The latency of GVS-cVEMP in children is slightly shorter than that in adults,therefore we recommend selecting the matched age group for assessment in the children group.
10.Near-infrared Spectroscopic Quality Control on Coating Process of Vitamin C Yinqiao Tablets
Qing TAO ; Li JIANG ; Youbing ZHONG ; Zhengji JIN ; Xiaoyong RAO ; Wei LIU ; Yan HE ; Yongkun GUO ; Xiaojian LUO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(14):184-190
ObjectiveTo construct a quantitative prediction model of three indicators(moisture absorption rate, film thickness and coating weight gain) during the coating process of Vitamin C Yinqiao tablets(VCYT) by near-infrared spectroscopy(NIRS), and to realize the endpoint judgment. MethodReal-time NIRS data of 4 batches of VCYT during the coating process were collected by diffuse reflection method. The coating method employed was the rolling coating method, and the samples were obtained at the spray stage from the coater's sampling port every 10 minutes, and 57 batches of samples(about 1 800 tablets) were collected at various coating times, the tablets were embedded in molten paraffin, cut longitudinally, and observed by stereomicroscope. The film thickness, with a target value of 38 μm, was then measured using Motic Images Advanced 3.2 software. Furthermore, the mositure absorption rate of samples, aiming for a target value of 3%, was determined in accordance with guiding principles for drug hygroscopicity testing in the 2020 edition of Chinese Pharmacopoeia, and 3 samples were randomly selected from each batch(10 tablets per batch), and the coating weight gain was calculated(target value of 4%). Partial least squares regression(PLSR) was used to construct a quantitative model of the 3 coating indicators, and the predicted values of the coating indicators were smoothed using the moving average method and used to determine the coating endpoints. ResultThe prediction determination coefficients(Rp2) for moisture absorption rate, film thickness and coating weight gain were 0.933 4, 0.932 6 and 0.965 9, the root mean square errors of prediction(RMSEP) were 0.163 5%, 1.870 9 μm and 0.240 3%, the relative percent deviations(RPD) were 3.711 0, 2.760 7 and 5.415 8, respectively. The results of the external validation set demonstrated that the real-time predicted values obtained by the models exhibited the same trend as the measured values, and the coating endpoint could be accurately predicted(with a prediction error of less than 7.32 min and a relative error of less than 5.63%). ConclusionThe established NIRS model exhibits excellent predictive performance and can be used for quality control of VCYT during the coating process.

Result Analysis