1.Results of physiological experiments using a home-made high performance human centrifuge
Minghao YANG ; Lihui ZHANG ; Cong WANG ; Ke JIANG ; Haixia WANG ; Xiaoyang WEI ; Yi WANG ; Xiaoxue ZHANG ; Jie YU ; Zhao JIN
Chinese Journal of Aerospace Medicine 2025;36(3):182-187
Objective:To find out whether the performance of a China-made high performance human centrifuge can satisfy the need of high G training by conducting physiological experiments.Methods:The dynamic physical performance of the anti-G equipment with the human centrifuge was tested before 5 subjects underwent the gradual-onset rate (GOR) run and rapid onset rate (ROR) run experiments. The G onset rate of GOR was 0.1 G/s. The relaxed G-tolerance under GOR (GOR tolerance 1) and the anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) were tested respectively. The G onset rate of ROR was 3 G/s, and the closed-loop mode and pre-programed mode were employed respectively. The closed-loop mode involved 5 G 10 s and 8 G 10 s, where the subjects were required to manipulate the joystick to ensure that the real-time curve of the load matched the target curve. In the pre-programmed mode, the subjects were exposed to 8 G 10 s passively, without any operation requirements. A subjective evaluation form was filled out by subjects after the experiments, in which the 14 indexes for evaluation were about the gondola facilities and environment, running processes, medical monitoring and overall assessment.Results:Both the oxygen mask and anti-G suit achieved full pressurization within 2.0 s. The GOR tolerance 1 was [4.0(3.8, 4.6)] G while the GOR tolerance 2 was (6.2±0.5) G, suggesting a statistically significant difference ( Z=-2.63, P=0.008). The HP anti-G straining maneuver effect was (2.0±0.6) G. All the 5 subjects finished the 5 G 10 s experiment in a closed-loop mode. Three of them attempted 8 G 10 s in the closed-loop mode (1 subject achieved only 7.6 G peak acceleration, and the other 2 achieved full 8 G 10 s exposure), while the remaining 2 completed the 8 G 10 s in the pre-programmed mode. In the closed-loop mode, it was found that the stick force was too strong, the guiding G and real time G curve were not easy to distinguish for some of the subjects because the curve colors were similar, and that the subjects could not see the G curves clearly in case of a grayout. Both seat comfort and the voice quality of communication got the highest subjective assessment score [5.0(4.0, 5.0)] while the sensation of tumble got the lowest score (2.8±0.8). The median or mean scores of other subjective evaluation indexes ranged from 3.0 to 4.6 points. The overall score of subjective assessment was [4.0(3.5, 4.0)] points. Conclusions:The China-made high performance human centrifuge can meet the requirements of 8.0 G high G training, which can be made more effective and comfortable if the strong stick force and feeling of tumble during stop running are overcome.
2.Surface electromyogram assessment of effectiveness of anti-G straining maneuver of high performance fighter pilots
Jinghui YANG ; Baohui LI ; Yan XU ; Haixia WANG ; Zhao JIN ; Xichen GENG ; Hong WANG ; Xiaoyang WEI ; Ke JIANG ; Yifeng LI ; Lihui ZHANG ; Xiaoxue ZHANG ; Minghao YANG
Chinese Journal of Aerospace Medicine 2025;36(2):113-118
Objective:To evaluate the effectiveness of anti-G straining maneuver (AGSM) in pilots by surface electromyography (sEMG), and to explore the relationships between characteristics of sEMG and anti-G endurance in pilots.Methods:Thirty-eight male high-performance fighter pilots who completed the human centrifuge test at the Air Force Medical Center were selected. Among them, 25 completed the 8.0 G for 10 s anti-G endurance test and 13 completed the 9.0 G for 10 s anti-G endurance test. The sEMG tester was used to keep track of the changes of sEMG in rectus abdominis, rectus femoris, anterior tibial and gastrocnemius muscles while pilots were engaged in AGSM. The anti-G endurance was evaluated according to the changes of visual fields and consciousness. The pilots were divided into 3 groups: the good vision and consciousness group, peripheral visual field narrowing group and endurance endpoint group. The differences in the integral electromyogram (iEMG), mean power frequency (MPF) and muscle input rates between the 3 groups were investigated.Results:A total of 25 pilots completed the 8.0 G for 10 s anti-G endurance test. Among them, 8 (32.0%) were in the good vision and consciousness group, 13 (52.0%) in the peripheral visual field narrowing group and 4 (16.0%) reached the endurance endpoint. Among the 13 pilots who completed the 9.0 G for 10 s anti-G endurance test, 3 (23.1%) were in the good vision and consciousness group, 6 (46.1%) in the peripheral visual field narrowing group, and 4 (30.8%) in the endurance endpoint group. The results of sEMG showed that the iEMG values of the anterior tibialis muscle in pilots under the 9.0 G for 10 s load were significantly different across endurance groups ( H=7.54, P=0.023), and that the iEMG values of the tibialis anterior muscle in the good vision and consciousness group were higher than those in the endurance endpoint group ( P=0.036). The negative slopes of MPF for the rectus abdominis, rectus femoris, anterior tibialis, and gastrocnemius muscles were higher in the good vision and consciousness group than in the other 2 groups, but the differences were not statistically significant ( P>0.05). During the 8.0 G for 10 s anti-G endurance test, there were significant differences in lower limb muscle contribution rates between the 3 groups ( F=4.19, P=0.029). The endurance endpoint group exhibited a lower contribution rate than the good vision and consciousness group ( P=0.025). During the 9.0 G for 10 s anti-G endurance test, there were significant differences in tibialis anterior muscle contribution rates between the 3 groups ( F=4.16, P=0.049). The endurance endpoint group demonstrated a lower contribution rate than the good vision and consciousness group ( P=0.049). Conclusions:The full and balanced activation of abdominal muscles and lower limb muscles, especially the effective mobilization of calf muscles, plays a pivotal role in improving pilots′ AGSM efficiency in high G environments.
3.Surface electromyogram assessment of effectiveness of anti-G straining maneuver of high performance fighter pilots
Jinghui YANG ; Baohui LI ; Yan XU ; Haixia WANG ; Zhao JIN ; Xichen GENG ; Hong WANG ; Xiaoyang WEI ; Ke JIANG ; Yifeng LI ; Lihui ZHANG ; Xiaoxue ZHANG ; Minghao YANG
Chinese Journal of Aerospace Medicine 2025;36(2):113-118
Objective:To evaluate the effectiveness of anti-G straining maneuver (AGSM) in pilots by surface electromyography (sEMG), and to explore the relationships between characteristics of sEMG and anti-G endurance in pilots.Methods:Thirty-eight male high-performance fighter pilots who completed the human centrifuge test at the Air Force Medical Center were selected. Among them, 25 completed the 8.0 G for 10 s anti-G endurance test and 13 completed the 9.0 G for 10 s anti-G endurance test. The sEMG tester was used to keep track of the changes of sEMG in rectus abdominis, rectus femoris, anterior tibial and gastrocnemius muscles while pilots were engaged in AGSM. The anti-G endurance was evaluated according to the changes of visual fields and consciousness. The pilots were divided into 3 groups: the good vision and consciousness group, peripheral visual field narrowing group and endurance endpoint group. The differences in the integral electromyogram (iEMG), mean power frequency (MPF) and muscle input rates between the 3 groups were investigated.Results:A total of 25 pilots completed the 8.0 G for 10 s anti-G endurance test. Among them, 8 (32.0%) were in the good vision and consciousness group, 13 (52.0%) in the peripheral visual field narrowing group and 4 (16.0%) reached the endurance endpoint. Among the 13 pilots who completed the 9.0 G for 10 s anti-G endurance test, 3 (23.1%) were in the good vision and consciousness group, 6 (46.1%) in the peripheral visual field narrowing group, and 4 (30.8%) in the endurance endpoint group. The results of sEMG showed that the iEMG values of the anterior tibialis muscle in pilots under the 9.0 G for 10 s load were significantly different across endurance groups ( H=7.54, P=0.023), and that the iEMG values of the tibialis anterior muscle in the good vision and consciousness group were higher than those in the endurance endpoint group ( P=0.036). The negative slopes of MPF for the rectus abdominis, rectus femoris, anterior tibialis, and gastrocnemius muscles were higher in the good vision and consciousness group than in the other 2 groups, but the differences were not statistically significant ( P>0.05). During the 8.0 G for 10 s anti-G endurance test, there were significant differences in lower limb muscle contribution rates between the 3 groups ( F=4.19, P=0.029). The endurance endpoint group exhibited a lower contribution rate than the good vision and consciousness group ( P=0.025). During the 9.0 G for 10 s anti-G endurance test, there were significant differences in tibialis anterior muscle contribution rates between the 3 groups ( F=4.16, P=0.049). The endurance endpoint group demonstrated a lower contribution rate than the good vision and consciousness group ( P=0.049). Conclusions:The full and balanced activation of abdominal muscles and lower limb muscles, especially the effective mobilization of calf muscles, plays a pivotal role in improving pilots′ AGSM efficiency in high G environments.
4.Results of physiological experiments using a home-made high performance human centrifuge
Minghao YANG ; Lihui ZHANG ; Cong WANG ; Ke JIANG ; Haixia WANG ; Xiaoyang WEI ; Yi WANG ; Xiaoxue ZHANG ; Jie YU ; Zhao JIN
Chinese Journal of Aerospace Medicine 2025;36(3):182-187
Objective:To find out whether the performance of a China-made high performance human centrifuge can satisfy the need of high G training by conducting physiological experiments.Methods:The dynamic physical performance of the anti-G equipment with the human centrifuge was tested before 5 subjects underwent the gradual-onset rate (GOR) run and rapid onset rate (ROR) run experiments. The G onset rate of GOR was 0.1 G/s. The relaxed G-tolerance under GOR (GOR tolerance 1) and the anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) were tested respectively. The G onset rate of ROR was 3 G/s, and the closed-loop mode and pre-programed mode were employed respectively. The closed-loop mode involved 5 G 10 s and 8 G 10 s, where the subjects were required to manipulate the joystick to ensure that the real-time curve of the load matched the target curve. In the pre-programmed mode, the subjects were exposed to 8 G 10 s passively, without any operation requirements. A subjective evaluation form was filled out by subjects after the experiments, in which the 14 indexes for evaluation were about the gondola facilities and environment, running processes, medical monitoring and overall assessment.Results:Both the oxygen mask and anti-G suit achieved full pressurization within 2.0 s. The GOR tolerance 1 was [4.0(3.8, 4.6)] G while the GOR tolerance 2 was (6.2±0.5) G, suggesting a statistically significant difference ( Z=-2.63, P=0.008). The HP anti-G straining maneuver effect was (2.0±0.6) G. All the 5 subjects finished the 5 G 10 s experiment in a closed-loop mode. Three of them attempted 8 G 10 s in the closed-loop mode (1 subject achieved only 7.6 G peak acceleration, and the other 2 achieved full 8 G 10 s exposure), while the remaining 2 completed the 8 G 10 s in the pre-programmed mode. In the closed-loop mode, it was found that the stick force was too strong, the guiding G and real time G curve were not easy to distinguish for some of the subjects because the curve colors were similar, and that the subjects could not see the G curves clearly in case of a grayout. Both seat comfort and the voice quality of communication got the highest subjective assessment score [5.0(4.0, 5.0)] while the sensation of tumble got the lowest score (2.8±0.8). The median or mean scores of other subjective evaluation indexes ranged from 3.0 to 4.6 points. The overall score of subjective assessment was [4.0(3.5, 4.0)] points. Conclusions:The China-made high performance human centrifuge can meet the requirements of 8.0 G high G training, which can be made more effective and comfortable if the strong stick force and feeling of tumble during stop running are overcome.
5.Investigation on human centrifuge training performance of the flying cadets recovered from COVID-19
Xiaoxue ZHANG ; Minghao YANG ; Hong WANG ; Zhao JIN ; Yan XU ; Baohui LI ; Lihui ZHANG ; Ke JIANG ; Haixia WANG ; Jinghui YANG ; Yifeng LI ; Yuanjing ZHENG ; Xiaoyang WEI
Chinese Journal of Aerospace Medicine 2024;35(2):128-131
Objective:To explore whether Corona Virus Disease 2019 (COVID-19) has any impact on human centrifuge training of flying cadets and to provide references to the human centrifuge training for the recovered flying personnel by comparing the changes of flying cadets′ G-tolerance and physiological indicators in human centrifuge training.Methods:Twelve flying cadets who underwent the current batch of human centrifuge training in 2022 were selected and divided into rehabilitation group and control group according to whether they had been infected with COVID-19, with 6 in each group. The rapid G onset rate (ROR) and gradual G onset rate (GOR) were respectively chosen for human centrifuge test. At the same time, the changes of their heart rate and respiratory rate during the tests were recorded, and the G-tolerance situations of the subjects were collected.Results:The average relaxed G-tolerance under GOR (GOR tolerance 1) was (4.2±0.8) G in rehabilitation group, and their average anti-G straining maneuver aided G-tolerance under GOR (GOR tolerance 2) was (5.7±0.6) G. Compared with that of the control group, there was no significant difference in GOR tolerance 1 and GOR tolerance 2 (both P>0.05). There was no significant changes in heart rate and respiratory rate in ROR and GOR human centrifuge tests between 2 groups (all P>0.05). Conclusions:COVID-19 didn't impact the recovered flying cadets' performance in human centrifuge training, as well as the anti-G straining maneuver effect and cardiovascular regulation.
6.Network Meta-analysis of the effects of different types of exercises on children with attention deficit hyperactivity disorder
Lingrong XIAO ; Hongmei WU ; Gang ZHAO ; Yisi JIN ; Xiaoxue WU ; Siyan LIU ; Junru LI
Chinese Journal of Behavioral Medicine and Brain Science 2024;33(8):727-735
Objective:To evaluate the effects of different exercises on executive function, moter skills and core symptoms in children with attention deficit hyperactivity disorder (ADHD) using network Meta-analysis, and to provide evidence-based basis for the treatment of children with ADHD.Methods:The randomized controlled trails(RCTs)of exercises on children with ADHD were searched in Web of Science, PubMed, Cochrane Library, Embase, PsycINFO, CNKI, Wanfang Data, VIP and CBM databases.The retrieval time limit was from the establishment of each database to May 2023.The Cochrane quality review manual was used to evaluate the quality of the included literatures.Stata 17.0 software was used to perform network Meta-analysis.Results:Finally, twenty-four studies were enrolled including five types of exercise intervention, such as aerobic exercise, multicomponent exercise, exergaming, high intensity interval training (HIIT) and traditional low-to-moderate intensity exercise therapy (TRAD).The results of network Meta-analysis showed that: in terms of improving executive function(working memory, inhibitory control, and cognitive flexibility), motor skills and core symptoms of children with ADHD, the optimal exercise intervention was aerobic exercises (surface under the cumulative ranking were 78.9%, 73.0%, 88.7%, 77.9% and 69.9% respectively).Conclusion:Exercises can improve executive function, improve motor skills, and alleviate ADHD core symptoms.Aerobic exercise has a better effect on improving executive function, motor skills and core symptoms of ADHD children.
7.Changing resistance profiles of Proteus,Morganella and Providencia in hospitals across China:results from the CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Yunmin XU ; Xiaoxue DONG ; Bin SHAN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Ping JI ; Fengbo ZHANG ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Hongyan ZHENG ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WEN ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2024;24(4):410-417
Objective To understand the changing distribution and antimicrobial resistance profiles of Proteus,Morganella and Providencia in hospitals across China from January 1,2015 to December 31,2021 in the CHINET Antimicrobial Resistance Surveillance Program.Methods Antimicrobial susceptibility testing was carried out following the unified CHINET protocol.The results were interpreted in accordance with the breakpoints in the 2021 Clinical & Laboratory Standards Institute(CLSI)M100(31 st Edition).Results A total of 32 433 Enterobacterales strains were isolated during the 7-year period,including 24 160 strains of Proteus,6 704 strains of Morganella,and 1 569 strains of Providencia.The overall number of these Enterobacterales isolates increased significantly over the 7-year period.The top 3 specimen source of these strains were urine,lower respiratory tract specimens,and wound secretions.Proteus,Morganella,and Providencia isolates showed lower resistance rates to amikacin,meropenem,cefoxitin,cefepime,cefoperazone-sulbactam,and piperacillin-tazobactam.For most of the antibiotics tested,less than 10%of the Proteus and Morganella strains were resistant,while less than 20%of the Providencia strains were resistant.The prevalence of carbapenem-resistant Enterobacterales(CRE)was 1.4%in Proteus isolates,1.9%in Morganella isolates,and 15.6%in Providencia isolates.Conclusions The overall number of clinical isolates of Proteus,Morganella and Providencia increased significantly in the 7-year period from 2015 to 2021.The prevalence of CRE strains also increased.More attention should be paid to antimicrobial resistance surveillance and rational antibiotic use so as to prevent the emergence and increase of antimicrobial resistance.
8.Construction of triple prerehabilitation protocol for patients undergoing pancreaticoduodenectomy
Sihan WANG ; Jin XIA ; Xiaomei WANG ; Yanfei WU ; Mei WANG ; Yaling WANG ; Xiaoxue CHEN ; Huixia LIU
Chongqing Medicine 2024;53(15):2339-2342,2348
Objective To construct the triple pre-rehabilitation program for the patients undergoing pancreaticoduodenectomy to provide a theoretical basis for the preoperative management of this operation mode.Methods The raft plan was formed by the literature research and group discussion,then the experts were invited to conduct the two rounds of expert consultation,and the final draft of the plan was finally formed.Results The draft plan included the 3 first-level items,9 second-level items and 28 third-level items.The questionnaire recovery rate of the two rounds of expert correspondence was 100%,and the authority coef-ficients were 0.88 and 0.93,respectively.The mean importance and feasibility scores of each item in the two rounds of expert consultation were ≥3.5,and the coefficient of variation was<0.25.The first draft of the final formation plan included the 3 first-level items,9 second-level items and 31 third-level items.Conclusion This program has ne-cessity,scientificity and feasibility.Clarifying the specific contents and scope of preoperative management of this operation mode could provide a theoretical basis for medical staff to carry out pre-rehabilitation.
9.Efficacy evaluation of different anti-G physical training programs for pilots
Jinghui YANG ; Xichen GENG ; Minghao YANG ; Zhao JIN ; Baohui LI ; Jie YU ; Yuhang LIU ; Haixia WANG ; Xiaoyang WEI ; Ke JIANG ; Lihui ZHANG ; Yifeng LI ; Qianyun ZHU ; Xiaoxue ZHANG ; Yan XU
Space Medicine & Medical Engineering 2024;35(1):38-41
Objective To establish a scientific training program that takes into account both anaerobic and aerobic training for pilots,and to explore the appropriate ratio of aerobic and anaerobic training.Methods According to the physical examination standards for pilots,a total of 16 healthy subjects aged 18-24 were selected from two batches.The two batches of subjects were trained with different aerobic and anaerobic ratios.Training period was 3 months.The changes in cardiopulmonary function of the subjects before and after training were evaluated using the cardiopulmonary function exercise testing system(CPET),and the changes in anaerobic capacity were evaluated using changes in strength as an indicator.Results After training,the weight load of the subjects in the two training programs,including barbell squats,leg flexion and hard pull,and barbell under 10RM and 3RM,was significantly increased(P<0.001),and there was no statistically significant difference in anaerobic strength growth between the two groups.The results of CPET showed that the maximum load,maximum heart rate,and respiratory quotient in the two groups were significantly increased after than before the training(P<0.01).The maximum load(Experiment group 1:29.12±19.69,Experiment group 2:72.00±46.24)and respiratory quotient(Experiment grouop 1:0.11±0.09,Experiment group 2:0.28±0.16)of the subjects in experiment group 2 before and after training were greater than those in experiment group 1.The difference was statistically significant(P<0.05).Conclusion The anaerobic and aerobic capacities of the subjects in the experiment group 2 are effectively improved,indicating that ratio of aerobic and anaerobic of the training scheme is better.
10.Effect of Ferroptosis on Diabetes Mellitus and Its Complications and Intervention of Chinese Medicine: A Review
Qinyuan ZHANG ; Zhisheng JIN ; Xiaoxue JIANG ; Yanxu CHEN ; Boling ZHANG ; Yaoqin FU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(6):280-288
Diabetes mellitus is a metabolic disease characterized by chronic hyperglycemia caused by absolute or relative insufficiency of insulin secretion. As the disease progresses, patients begin to suffer from diabetic nephropathy, diabetic cardiomyopathy, non-alcoholic fatty liver disease or other complications, which increase the burden on the patients. Moreover, the number of patients is increasing, which brings a heavy burden to the society. Ferroptosis is a new type of programmed cell death which has attracted wide attention in recent years. It refers to the cell death caused by the excessive accumulation of lipid peroxide under the overload of iron ions. Studies have discovered that ferroptosis exists in diabetes mellitus and its complications. Inhibiting ferroptosis can greatly slow down the occurrence and progression of diabetes mellitus and its complications. Chinese medicine, the unique medical treasure in China, acts in a multi-pathway, multi-target manner and is praised for the cheap price, low toxicity, and mild side effects. It has been widely used in the treatment of diabetes mellitus and its complications and has demonstrated definite therapeutic effects, bringing the good news for the majority of patients. The regulation of ferroptosis by Chinese medicine may be a new direction for the treatment of diabetes mellitus and its complications in the future. This paper briefly describes the mechanism of ferroptosis, explores the relationship of ferroptosis with diabetes mellitus and its complications, summarizes the research status of Chinese medicine interventions, and puts forward suggestions, aiming to provide a reference for further research on the treatment of diabetes mellitus and its complications with Chinese medicine.

Result Analysis
Print
Save
E-mail