1.Analysis of the predictive value of acetabular prosthesis selection and osteotomy accuracy in adult devel-opmental dysplasia of the hip total hip arthroplasty based on MSCT 3D scanning + reconstruction
Xiaorong CUI ; Lihua LAN ; Xiangyang LI ; Zhifeng ZHONG
The Journal of Practical Medicine 2024;40(9):1309-1313
Objective To explore the effect of MSCT 3D scanning and reconstruction on developmental dysplasia of the hip(DDH)in adult patients with total hip arthroplasty,The predictive value of acetabular prosthesis selection and osteotomy accuracy in THA.Methods Selection in our hospital between February 2021 and February 2023 were 60 adult DDH patients underwent total hip replacement,which USES routine preoperative planning as a control group of 30 patients,and using MSCT + reconstruction of 3 d scanning technology as observation group of 30 patients,planning after the completion of the planning of the surgical operation and implant placement,Relevant information was collected before and after the operation of the two groups.Operation time,intraoperative blood loss,intraoperative fluoroscopy time,acetabular prosthesis selection and matching rate,femur split fracture rate,pelvis and acetabular reduction quality,Majeed score and Harris hip function score were compared between the two groups.The osteotomy distance and sharp shoulder distance of the two groups were compared before planning and in actual conditions,and the correlation between MSCT 3D scanning and reconstruction technology and the accuracy of acetabular prosthesis selection was evaluated.Results Results analysis showed that MSCT 3D scanning+reconstruc-tion technology used in preoperative evaluation of patients in the observation group was correlated with the accuracy of acetabular prosthesis selection(P<0.05),and the absolute errors of osteotomy distance and sharp shoulder distance of patients in the observation group were smaller than the actual situation before planning(P<0.05).In addition,compared with the control group,the operative time,intraoperative blood loss,intraoperative fluoroscopy time and incidence of femoral split fracture in the observation group were significantly lower,and the matching rate of acetabular prosthesis selection,the Majeed scores and Harris scores were significantly higher in the following 3 months were significantly higher(P<0.05).The reduction quality of pelvis and acetabulum was not statistically significant between the two groups(P>0.05).Conclusion Msct-based 3D scanning + reconstruction has a high predictive value for the selection of acetabular prosthesis and the accuracy of osteotomy in adult DDH total hip replacement,and the use of this technology for preoperative planning has a significant optimization effect on the actual treatment effect and patient recovery.
2.Reliability and validity of the Chinese version of disability attitude scale
Hong DONG ; Lian ZHU ; Dakuan GAO ; Xiaorong FENG ; Wanli MA ; Huixia CUI
Modern Clinical Nursing 2024;23(2):52-57
Objective Reliability and validity of the Chinese version of disability attitude scales(DAS-CN)toward disabled persons were created and tested to provide an assessment instrument for measuring the attitude of medical staff toward disabled persons in China.Methods Authorised by the author of DAS in August 2020,based on BRISLIN translation model,the English version of DAS was translated into Chinese followed by back translation,cultural debugging and then put it into pre-experiment in September 2020.The reliability and validity of the finalised DAS-CN were further tested in a survey with 400 randomly selected medical staff in rehabilitation from 8 general hospitals in Jinzhou,Panjin,Yingkou and Fushun in Liaoning Province,China by using the convenience sampling method in March 2021.Results A total of 357 surveyees completed the survey.The localised DSA-CN was composed of 4 dimensions with a total of 20 items,including 4 items in clinical knowledge and skills,4 in clinical responsibility,8 in clinical behaviour and 4 in emotional response.The Cronbach α coefficient of the scales was 0.943,with the split-half reliability and test-retest reliability at 0.824 and 0.899,respectively.The Cronbach α coefficient of each dimension was 0.843~0.944,and the split half reliability was 0.854~0.904.The test-retest reliability ranged from 0.701 to 0.913.The KMO value of exploratory factor analysis was 0.921.The Bartrett spherical test value was 5534.981(P<0.01).The total explanatory rate of variation was 73.050%.Conclusion The Chinese version of Disability Attitude Scales(DSA-CN)has good reliability and validity.Therefore,DSA-CN can be used as an instrument in investigation of the current status about the attitudes towards the disabled persons among the medical staff in China.
3.Application of magnetic resonance imaging in patients with type 2 diabetic painful neuropathy
Shuqian WANG ; Cancan HUI ; Yuwei CHENG ; Xiujuan HU ; Xiaorong YIN ; Mengjie CUI ; Qinyi HUANG ; Yangliu YIN ; Yan SUN
Journal of Clinical Medicine in Practice 2024;28(8):16-21
Objective To observe the application effect of magnetic resonance imaging technology in evaluating the brain structure and function of patients with type 2 diabetic painful neuropathy (PDN). Methods Forty patients with type 2 diabetes mellitus hospitalized in our hospital were selected as the study objects, and were divided into diabetes mellitus (DM) group (
4.A consensus on the management of allergy in kindergartens and primary schools
Chinese Journal of School Health 2023;44(2):167-172
Abstract
Allergic diseases can occur in all systems of the body, covering the whole life cycle, from children to adults and to old age, can be lifelong onset and even fatal in severe cases. Children account for the largest proportion of the victims of allergic disease, Children s allergies start from scratch, ranging from mild to severe, from less to more, from single to multiple systems and systemic performance, so the prevention and treatment of allergic diseases in children is of great importance, which can not only prevent high risk allergic conditions from developing into allergic diseases, but also further block the process of allergy. At present, there is no consensus on the management system of allergic children in kindergartens and primary schools. The "Consensus on Allergy Management and Prevention in Kindergartens and Primary Schools", which includes the organizational structure, system construction and management of allergic children, provides evidence informed recommendations for the long term comprehensive management of allergic children in kindergartens and primary schools, and provides a basis for the establishment of the prevention system for allergic children.
5.Predictive value of neutrophil/lymphocyte ratio for stroke-associated pneumonia in patients with acute ischemic stroke
Sai KUANG ; Zhanhang CUI ; Xue LIU ; Jia LIU ; Xiaorong YANG ; Yuefei WEI ; Yan WU ; Chan REN ; Haimei SUN
International Journal of Cerebrovascular Diseases 2023;31(9):658-663
Objective:To investigate the predictive value of neutrophil/lymphocyte ratio (NLR) at admission for stroke associated pneumonia (SAP) in patients with acute ischemic stroke (AIS).Methods:Patients with AIS admitted to the First Affiliated Hospital of Kunming Medical University from January 2019 to June 2020 were retrospectively included. The demographic information, vascular risk factors, severity of stroke at admission, and NLR data of the patients were collected. Multivariate logistic regression was used to analyze the independent correlation between NLR and SAP. The NLR was divided into quartile groups to further analyze the trend relationship between NLR and SAP. Receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of NLR for SAP. Results:A total of 316 patients with AIS were enrolled, including 200 males (63.29%) with an age of 63.86±13.78 years. The median baseline Nationanl Institutes of Health Stroke Scale score was 4 (interquartile range, 2-9), and the median NLR was 4.42 (interquartile range, 3.17-6.70). Ninety-three patients (29.43%) experienced SAP. Multivariate logistic regression analysis showed that NLR was an independent risk factor for SAP in patients with AIS (odds ratio 1.189, 95% confidence interval 1.077-1.313; P<0.001). Moreover, SAP risk increases with the increase of NLR ( Ptrend<0.001). Compared to the first quartile, the risk of SAP increased 9.991 times in the fourth quartile (95% confidence interval 2.912-34.279; P<0.001). ROC curve analysis showed that the area under the curve of NLR for SAP prediction was 0.793 (95% confidence interval 0.737-0.850), with an optimal cutoff value of 5.475. The sensitivity and specificity for predicting SAP were 66.67% and 79.82%, respectively. Conclusion:NLR at admission is an independent risk factor for SAP in patients with AIS and has certain predictive value for SAP.
6.Association of time in range and glucose management indicator with the risk of type 2 diabetic nephropathy
Shuqian Wang ; Xiujuan Hu ; Xiaorong Yin ; Mengjie Cui ; qinyi Huang ; Yangliu Yin ; Cancan Hui ; Yuwei Cheng ; Ya Zhang ; Yan Sun
Acta Universitatis Medicinalis Anhui 2023;58(10):1782-1786
Objective :
To explore the association of time in range(TIR) and glucose management indicator ( GMI) with the risk of type 2 diabetic nephropathy (DN) .
Methods :
The clinical data of 215 patients with type 2 diabetes mellitus (T2DM) were collected and analyzed.According to the results of estimated glomerular filtration rate (eGFR) and urinary albumin to creatinine ratio( UACR) ,they were divided into 117 patients with T2DM and 98 patients with DN.The clinical data,biochemical indicators and continuous glucose monitoring ( CGM) indicators of the two groups were compared.Logistic regression was used to analyze the influencing factors of DN risk.The predictive value of TIR and GMI on the risk of DN was evaluated by receiver operating characteristic (ROC) curve.
Results:
There were significant differences in age,duration of diabetes,systolic blood pressure,glycosylated hemoglobin ( HbA1c) ,fasting plasma glucose (FPG) ,2 hour postprandial plasma glucose (2hPG) ,creatinine( Cr) ,UACR, eGFR between the two groups(P<0. 05) .There were statistically significant differences between the two groups in the CGM indexes of GMI,mean absolute difference of mean of daily differences ( MODD) ,glucose above target range time(TAR) and TIR(P<0. 05) .The results of logistic regression analysis showed that TIR was a protective factor of DN.In the ROC curve analysis of TIR prediction DN,the area under the ROC curve was 0. 718 (95% CI = 0. 648 ~0. 789,P<0. 001) ,and the Yoden index was 0. 38.At this time,the sensitivity was 66. 7% ,and the specificity was 71. 3%.In the ROC curve analysis of GMI prediction DN,the area under the ROC curve was 0. 701 (95% CI = 0. 629 ~0. 774,P<0. 001) ,and the Yoden index was 0. 368.At this time,the sensitivity was 63. 3% , and the specificity was 73. 5%.
Conclusion
Specifically,lower TIR and higher GMI increase the risk of DN.
7.A preterm infant born to a mother with severe influenza A
Xiaorong XIA ; Hongmei LU ; Yafei GUAN ; Xiaolin MIAO ; Shudong CUI ; Jingjing PAN ; Xiaoqing CHEN
Chinese Journal of Perinatal Medicine 2020;23(7):489-491
We report a case of a 2 200 g premature male baby born through cesarean section under maternal endotracheal intubation mechanical ventilation combined with extracorporeal membrane oxygenation at 34 +1 gestational weeks, while his mother was infected with influenza A in late pregnancy. Due to neonatal pneumonia, neonatal respiratory distress syndrome, prematurity, and low birth weight, the neonate was transferred to the neonatal intensive care unit for body temperature maintenance, respiratory support, maintenance of perfusion and internal environment, and nutritional management. The infant was discharged 17 days after birth and was well at six-month-old follow-up. His mother was discharged at 20 days post-delivery.
8. Differential expression and bioinformation analysis of retinal proteins in mice with experimental autoimmune uveitis
Shuang CHEN ; Xianfeng SHAO ; Zhihui ZHANG ; Nu CHEN ; Lingzi WU ; Xuexue CUI ; Xiaorong LI ; Xiaomin ZHANG
Chinese Journal of Experimental Ophthalmology 2019;37(12):949-955
Objective:
To observe the expression of retinal proteins in experimental autoimmune uveitis (EAU) mice and to explore the possible molecular mechanism of autoimmune uveitis.
Methods:
Twelve female C57BL/6J mice were randomly divided into model group and normal control group, 6 mice in each group.In the model group, the EAU model was established by subcutaneous injection of human interphotoreceptor retinoid-binding protein (IRBP) 651-670.The fundal change of EAV mice was assessed by direct ophthalmoscope, OCT and histopathological staining.At 18 days after immunization, the retinas of the two groups were taken for retinal protein extraction, protein restriction enzyme digestion, mass spectrometry detection, data analysis, and bioinformatics analysis.This study was approved by the experimental animal Ethics Committee of Tianjin Medical University Eye Hospital (TJYY2018070113). The feeding and use of experimental animals follow the ARVO statement.
Results:
The EAU mouse model was successfully established.At 10 days after immunitation, the retina of EAV mouse was damaged.At 18 days after immunization, retinal edema and infiltration of inflammatory cells into vitreous were observed.Proteomic results showed that a total of 4 458 proteins were identified in this study, of which 522 were differentially-expressed proteins (fold change>1.5,
9.Simultaneous Determination of 6 Components in Chaihuang Tablets by HPLC-DAD
Changling DING ; Junfeng CUI ; Xiaorong SHI ; Yangyang XU ; Wenna CHENG ; Jinjie ZHANG ; Li ZHAO
China Pharmacy 2019;30(11):1477-1481
OBJECTIVE: To establish a method for simultaneous determination of 6 components in Chaihuang tablets, such as baicalin, wogonoside, baicalein, wogonin, saikosaponin a and saikosaponin d in Chaihuang tablets. METHODS: HPLC-DAD method was used to detect 3 batches of Chaihuang tablets from same manufacturers. The determination was performed on Agilent Eclipse XDB-C18 column with mobile phase consisted of acetonitrile-triethylamine phosphate aqueous solution (pH adjusted to 7.0, gradient elution) at flow rate of 1.0 mL/min. The detection wavelengths were set at 210 nm (saikosaponin a, saikosaponin d) and 277 nm (baicalin, wogonoside, baicalein, wogonin). The column temperature was 30 ℃, and sample size was 5 μL. RESULTS: The linear ranges of baicalin, wogonoside, baicalein, wogonin, saikosaponin a and saikosaponin d were 0.379 5-7.590 4 μg, 0.082 96-1.659 2 μg, 0.039 39-0.787 8 μg, 0.040 72-0.814 4 μg, 0.040 45-0.809 0 μg, 0.038 63-0.772 6 μg (all r≥0.999 3), respectively. The limits of detection were 0.008, 0.007, 0.005, 0.005, 0.020 and 0.018 μg/mL. The limits of quantitation were 0.025, 0.022, 0.015, 0.015, 0.060, 0.054 μg/mL. RSDs of precision, reproducibility and stability tests (48 h) were all lower than 1.5% (n=6). Average recoveries were 98.46%, 97.06%, 100.90%, 96.13%, 96.91%, 96.57% (RSD<2.0%, n=6). CONCLUSIONS: Established method is simple, accurate and reproducible for 6 components in Chaihuang tablets, and can be used for quality control of the tablet.
10.Discussion on the standard of clinical genetic testing report and the consensus of gene testing industry.
Hui HUANG ; pengzhiyu@bgi.com. ; Yiping SHEN ; Weihong GU ; Wei WANG ; Yiming WANG ; Ming QI ; Jun SHEN ; Zhengqing QIU ; Shihui YU ; Zaiwei ZHOU ; Baixue CHEN ; Lei CHEN ; Yundi CHEN ; Huanhuan CUI ; Juan DU ; Yong GAO ; Yiran GUO ; Chanjuan HU ; Liang HU ; Yi HUANG ; Peipei LI ; Xiaorong LI ; Xiurong LI ; Yaping LIU ; Jie LU ; Duan MA ; Yongyi MA ; Mei PENG ; Fang SONG ; Hongye SUN ; Liang WANG ; Dawei WANG ; Jingmin WANG ; Ling WANG ; Zhengyuan WANG ; Zhinong WANG ; Jihong WU ; Jing WU ; Jian WU ; Yimin XU ; Hong YAO ; Dongsheng YANG ; Xu YANG ; Yanling YANG ; Ying ZHANG ; Yulin ZHOU ; Baosheng ZHU ; Sicong ZENG ; Zhiyu PENG ; Shangzhi HUANG
Chinese Journal of Medical Genetics 2018;35(1):1-8
The widespread application of next generation sequencing (NGS) in clinical settings has enabled testing, diagnosis, treatment and prevention of genetic diseases. However, many issues have arisen in the meanwhile. One of the most pressing issues is the lack of standards for reporting genetic test results across different service providers. The First Forum on Standards and Specifications for Clinical Genetic Testing was held to address the issue in Shenzhen, China, on October 28, 2017. Participants, including geneticists, clinicians, and representatives of genetic testing service providers, discussed problems of clinical genetic testing services across in China and shared opinions on principles, challenges, and standards for reporting clinical genetic test results. Here we summarize expert opinions presented at the seminar and report the consensus, which will serve as a basis for the development of standards and guidelines for reporting of clinical genetic testing results, in order to promote the standardization and regulation of genetic testing services in China.


Result Analysis
Print
Save
E-mail