1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Comparative study on the efficacy of recombinant interferon-α-2b and ipratropium bromide in the treatment of pediatric bronchiolitis
Miao CHEN ; Xiaojuan SHEN ; Wenyan PAN
China Modern Doctor 2024;62(25):85-88
Objective To investigate the clinical effect of recombinant interferon(IFN)-α-2b and ipratropium bromide atomized inhalation in pediatric bronchiolitis.Methods A total of 112 children with bronchiolitis diagnosed and treated in Huzhou Central Hospital from April 2020 to August 2022 were selected and divided into control group and observation group according to envelope method,with 56 cases in each group.The control group was treated with atomization inhalation of ipratropium bromide,and the observation group was treated with atomization inhalation of recombinant IFN-α-2b.Both groups completed 7 days of treatment,and the lung function,interferon-γ(IFN-γ),interleukin-10(IL-10),immune function and adverse reaction were compared between two groups.Results After 7 days of intervention,the disappearance time of wheezing,cough,lung moist rales and sputum sounds in observation group were significantly shorter than those in control group(P<0.05).The tidal volume(TV),peak tidal expiratory flow(PTEF),ratio of time to peak tidal expiratory flow to total expiratory time(TPTEF/TE),IFN-γ and IL-10 in both groups were significantly higher than those before intervention(P<0.05).TV,PTEF,TPTEF/TE,IFN-γ and IL-10 in observation group were higher than those in control group(P<0.05).The levels of CD3+,CD4+and CD4+/CD8+in both groups were significantly higher than before intervention,and the levels of CD8+were significantly lower than before intervention(P<0.05).The levels of CD3+,CD4+and CD4+/CD8+in observation group were significantly higher than those in control group,and CD8+was significantly lower than that in control group(P<0.05).There was no significant difference in the incidence of adverse reactions between two groups(x2=0.704,P=0.401).Conclusion Both recombinant IFN-α-2b and ipratropium bromide atomized inhalation can achieve good therapeutic effect in children with bronchiolitis,but the former can help shorten the time of symptom disappearance and improve the immune level of children,and is worthy of clinical application.
6.Impact of different diagnostic criteria for assessing mild micro-hepatic encephalopathy in liver cirrhosis: an analysis based on a prospective, multicenter, real-world study
Xiaoyan LI ; Shanghao LIU ; Chuan LIU ; Hongmei ZU ; Xiaoqing GUO ; Huiling XIANG ; Yan HUANG ; Zhaolan YAN ; Yajing LI ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Fei LIU ; Lei HUANG ; Fanping MENG ; Xiaoning ZHANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Zhangshu QU ; Min YUAN ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yongzhong LI ; Qiaohua YANG ; Huai LI ; Xuelan ZHAO ; Zemin TIAN ; Hongji YU ; Xiaojuan ZHANG ; Chenxi WU ; Zhijian WU ; Shengqiang LI ; Qian SHEN ; Xuemei LIU ; Jianping HU ; Manqun WU ; Tong DANG ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Dongmei YAN ; Jun LIU ; Wei FU ; Jie YU ; Fusheng WANG ; Xiaolong QI ; Junliang FU
Chinese Journal of Hepatology 2023;31(9):961-968
Objective:To compare the differences in the prevalence of mild micro-hepatic encephalopathy (MHE) among patients with cirrhosis by using the psychometric hepatic encephalopathy score (PHES) and the Stroop smartphone application (Encephal App) test.Methods:This prospective, multi-center, real-world study was initiated by the National Clinical Medical Research Center for Infectious Diseases and the Portal Hypertension Alliance and registered with International ClinicalTrials.gov (NCT05140837). 354 cases of cirrhosis were enrolled in 19 hospitals across the country. PHES (including digital connection tests A and B, digital symbol tests, trajectory drawing tests, and serial management tests) and the Stroop test were conducted in all of them. PHES was differentiated using standard diagnostic criteria established by the two studies in China and South Korea. The Stroop test was evaluated based on the criteria of the research and development team. The impact of different diagnostic standards or methods on the incidence of MHE in patients with cirrhosis was analyzed. Data between groups were differentiated using the t-test, Mann-Whitney U test, and χ2 test. A kappa test was used to compare the consistency between groups. Results:After PHES, the prevalence of MHE among 354 cases of cirrhosis was 78.53% and 15.25%, respectively, based on Chinese research standards and Korean research normal value standards. However, the prevalence of MHE was 56.78% based on the Stroop test, and the differences in pairwise comparisons among the three groups were statistically significant (kappa = -0.064, P < 0.001). Stratified analysis revealed that the MHE prevalence in three groups of patients with Child-Pugh classes A, B, and C was 74.14%, 83.33%, and 88.24%, respectively, according to the normal value standards of Chinese researchers, while the MHE prevalence rates in three groups of patients with Child-Pugh classes A, B, and C were 8.29%, 23.53%, and 38.24%, respectively, according to the normal value standards of Korean researchers. Furthermore, the prevalence rates of MHE in the three groups of patients with Child-Pugh grades A, B, and C were 52.68%, 58.82%, and 73.53%, respectively, according to the Stroop test standard. However, among the results of each diagnostic standard, the prevalence of MHE showed an increasing trend with an increasing Child-Pugh grade. Further comparison demonstrated that the scores obtained by the number connection test A and the number symbol test were consistent according to the normal value standards of the two studies in China and South Korea ( Z = -0.982, -1.702; P = 0.326, 0.089), while the other three sub-tests had significant differences ( P < 0.001). Conclusion:The prevalence rate of MHE in the cirrhotic population is high, but the prevalence of MHE obtained by using different diagnostic criteria or methods varies greatly. Therefore, in line with the current changes in demographics and disease spectrum, it is necessary to enroll a larger sample size of a healthy population as a control. Moreover, the establishment of more reliable diagnostic scoring criteria will serve as a basis for obtaining accurate MHE incidence and formulating diagnosis and treatment strategies in cirrhotic populations.
7.Effect of water improvement project on drinking-water-borne endemic fluorosis in Qingdao in 2020
Xiaojuan DOU ; Fengying JI ; Enqiang FENG ; Suzhen LIU ; Xuekui LI ; Cuiling SHEN ; Limei SHI
Chinese Journal of Endemiology 2022;41(2):126-129
Objective:To assess the operation and usage conditions of all water improvement projects in Qingdao, master the water fluoride content and the prevalence of dental fluorosis in children in drinking-water-borne endemic fluorosis villages, evaluate the prevention and control effect of water improvement project.Methods:From April to October in 2020, all drinking-water-borne endemic fluorosis villages in 7 cities (districts) of Qingdao were selected to investigate the operation and usage conditions of water improvement project, water fluoride and prevalence of dental fluorosis of 8 to 12 years old children. The prevention and control effect of water improvement project on drinking-water-borne endemic fluorosis in Qingdao was evaluated according to the control contents and criteria of drinking-water-borne endemic fluorosis.Results:There were 1 146 drinking-water-borne endemic fluorosis villages, the water improved rate of villages was 100.00% (1 146/1 146), the rate of normal operation of water improvement project was 99.91% (1 145/1 146). There were 1 130 villages with qualified water fluoride and the qualified rate was 98.60% (1 130/1 146). A total of 23 473 children aged 8 - 12 years old were examined, and 631 children were detected with dental fluorosis. The detection rate of dental fluorosis was 2.69% (631/23 473), the dental fluorosis index was 0.048, and the prevalence was negative. The detection rate of dental fluorosis of children in villages with excessive water fluoride (7.03%, 40/569) was higher than that in villages with qualified water fluoride (2.58%, 591/22 904, χ 2 = 41.235, P < 0.01). Conclusion:The operation and usage conditions of water improvement projects in 7 drinking- water-borne endemic fluorosis cities (districts) in Qingdao are good, and the detection rate of dental fluorosis in children is low, which has reached the national control standard.
8.Surveillance results of iodine deficiency disorders in children aged 8-10 years in Qingdao City from 2018 to 2020
Xuekui LI ; Enqiang FENG ; Suzhen LIU ; Xiaojuan DOU ; Lina PENG ; Cuiling SHEN ; Limei SHI ; Fengying JI
Chinese Journal of Endemiology 2022;41(12):977-981
Objective:To investigate the iodine nutritional status of children in Qingdao City and the effects of prevention and treatment measures on iodine deficiency disorders (IDD), and to provide a scientific basis for guiding residents to scientifically supplement iodine, taking timely targeted prevention and control measures, and scientifically adjusting intervention strategies.Methods:According to "National Iodine Deficiency Disorders Surveillance Program (2016 edition)" and "Iodine Deficiency Disorders Surveillance Program of Shandong Province", from 2018 to 2020, using the cluster sampling method, children aged 8-10 years in Qingdao City were chosen to test their household salt iodine content and random urinary iodine content, and to examine their thyroid volume by B-ultrasonography, and the correlation between thyroid volume and physical development indexes was analyzed.Results:From 2018 to 2020, a total of 6 057 children were monitored, including 3 068 boys and 2 989 girls. The median of salt iodine and iodized salt iodine of children was 23.50 and 24.10 mg/kg. The qualified rate of iodized salt was 89.95% (4 832/5 372), the coverage rate of iodized salt was 88.69% (5 372/6 057), and the consumption rate of qualified iodized salt was 79.78% (4 832/6 057). There were significant differences in the qualified rate of iodized salt, the coverage rate of iodized salt and the consumption rate of qualified iodized salt between different years (χ 2 = 135.26, 314.71, 342.87, P < 0.001). A total of 6 057 urine samples were collected from children, and the median of urinary iodine was 193.92 μg/L, of which 16.2% (979/6 057) were < 100 μg/L, and 22.5% (1 361/6 057) were ≥300 μg/L. There were statistically significant differences in the medians of urinary iodine between different years, gender and whether eating iodized salt ( H/Z = 37.25,-3.89,-5.69, P < 0.001), the median of urinary iodine in boys was higher than that of girls, and the median of urinary iodine in eating iodized salt group was higher than that of eating non-iodized salt group. There was no significant difference in the median of urinary iodine between different age ( H = 4.33, P = 0.119). The rate of goiter in children was 3.45% (71/2 057), and the difference between different years was statistically significant (χ 2 = 42.68, P < 0.001). The incidence of goiter in 2020 [7.31% (45/616)] was significantly higher than that in 2018 and 2019 [2.81% (18/641), 1.00% (8/800), P < 0.001]. Thyroid volume of children was positively correlated with height and weight ( r = 0.20, 0.22, P < 0.001). Conclusions:The iodine nutritional level of children aged 8-10 years in Qingdao City is appropriate. However, the incidence of goiter in children in some years is relatively high. The qualified rate of iodized salt, the coverage rate of iodized salt and the consumption rate of qualified iodized salt are all lower than the national standard for elimination of IDD, which should be paid attention to.
9.Effect of prevention and control measures to drinking-water-borne endemic fluorosis in Qingdao from 2019 to 2021
Xiaojuan DOU ; Enqiang FENG ; Suzhen LIU ; Xuekui LI ; Jiwei LIANG ; Cuiling SHEN ; Limei SHI ; Fengying JI
Chinese Journal of Endemiology 2022;41(12):982-985
Objective:To evaluate the effect of prevention and control measures to drinking-water-borne endemic fluorosis in Qingdao, and to provide scientific basis for formulating prevention and control strategies.Methods:From 2019 to 2021, a full coverage surveillance was carried out in 1 146 villages in 7 drinking-water-borne endemic fluorosis areas in Qingdao, including the operation status of the water improvement and fluoride reduction project, the water fluoride content in the villages, and the prevalence of dental fluorosis among children aged 8-12 years.Results:From 2019 to 2021, all the 1 146 affected villages in Qingdao had improved their water supply, and the rates of water fluoride exceeding the standard were 7.16% (82/1 146), 1.40% (16/1 146) and 3.84% (44/1 146), respectively, and the differences between years were statistically significant (χ 2 = 48.36, P < 0.001). The detection rates of dental fluorosis in children aged 8-12 years were 3.11% (803/25 856), 2.68% (629/23 460) and 3.00% (655/21 846), respectively, and the differences between years were statistically significant (χ 2 = 8.26, P = 0.016). The detection rate of dental fluorosis among children in villages with qualified water fluoride (2.85%, 1 986/69 565) was lower than that in villages with excessive water fluoride (6.32%, 101/1 597), with a statistically significant difference (χ 2 = 67.74, P < 0.001). Conclusions:From 2019 to 2021, the effect of prevention and control measures to drinking-water-borne endemic fluorosis in Qingdao is significant and the detection rate of dental fluorosis in children is low, the detection rate of dental fluorosis in villages with qualified water fluoride is significantly lower than that in villages with excessive water fluoride. In the future, we should continue to strengthen water fluoride monitoring and engineering maintenance to ensure that the water fluoride content continues to be qualified and effectively reduce the harm of fluorosis.
10.Comparative analysis of blood components distribution in 24 domestic prefecture-level blood stations
Cheng PENG ; Guanlin HU ; Li LI ; Zhenxing WANG ; Jinghan ZHANG ; Yugen CHENG ; Liping HUANG ; Qiuhong MUO ; Yang LIU ; Wenzhi WANG ; Haining WANG ; Hao LI ; Youhua SHEN ; Xiaojuan YANG ; Guoqian YANG ; Ling WU ; Feng YAN ; Ning LI ; Jing LIU ; Lin BAO ; Mengshang ZHANG ; Jing CUI ; Zhujun FU ; Helong GUO ; Shutao PANG
Chinese Journal of Blood Transfusion 2022;35(9):942-946
【Objective】 To understand the current situation of blood components distribution in domestic prefecture-level blood stations through analyzing the components distribution data of 24 prefecture-level blood stations in China. 【Methods】 The data of components distribution of 24 blood stations from 2017 to 2020 as well as the data of blood deployment of 24 blood stations from 2019 to 2020 were collected and analyzed. 【Results】 From 2017 to 2020, positive annual growth in red blood cells, plasma and cryoprecipitate was observed in 22, 19 and 15 out of the 24 blood stations, and the annual growth median rate of above three components was 5.24%, 3.80% and 3.25%, respectively. Among the 24 prefecture-level blood stations, 23 carried out the preparation of cryoprecipitate. 【Conclusion】 The distribution of red blood cells, cryoprecipitate and plasma in prefecture-level blood stations is increasing year by year. However, there is a overstock of plasma, and most blood stations need blood employment.

Result Analysis
Print
Save
E-mail