1.Application of a wearable visual field meter based on extended reality glasses in macular disease
Jing YUAN ; Xingchang WANG ; Xiquan SUN ; Huiguang JIAO ; Qian WANG ; Yanxia TONG ; Biyue TU ; Xixi YAN ; Zhen ZHAO ; Xiaojie OU ; Sawut ABDULLA
Chinese Journal of Experimental Ophthalmology 2025;43(11):1035-1040
Objective:To evaluate the application effect of a wearable visual field meter based on extended reality (XR) glasses for patients with macular disease.Methods:A self-controlled study was conducted.A total of 41 consecutive patients (41 eyes) with macular disease were recruited at Renmin Hospital of Wuhan University from October 2022 to October 2024.All patients underwent 10-2 center visual field test using a self-developed wearable visual field meter (XRVF), and the results were compared with those obtained using a traditional Humphrey field analyzer (HFA).The comparison parameters included mean retinal sensitivity (MS), false positive rate (FPR), false negative rate (FNR), and testing duration.A subject satisfaction questionnaire was administered.This study followed the Declaration of Helsinki.The study protocol was approved by the Medical Ethics Committee of Renmin Hospital of Wuhan University (No.WDRY2024-K263), and all subjects signed the informed consent form.Results:The retinal sensitivity of patients measured by HFA was (23.24±3.71)dB, which was higher than (22.01±3.45)dB by XRVF, showing a statistically significant difference ( t=4.924, P=0.036).The FPR measured by HFA and XRVF were (2.39±2.51)% and (2.59±3.29)%, respectively, and the FNR were (3.49±6.05)% and (3.74±5.38)%, respectively, showing no statistically significant difference ( t=-3.624, P=0.948; t=-1.241, P=0.519).The median test duration for HFA and XRVF was 6.15 (5.78, 6.65) and 5.98 (5.71, 6.69)minutes, respectively, without statistically significant difference ( Z=-1.987, P=0.953).92.6% of the subjects thought the device was comfortable, simple and practical. Conclusions:The XRVF has good consistency with the HFA, can effectively and reliably evaluate the visual field function of patients with macular disease, and is easily accepted by patients.
2.Application of a wearable visual field meter based on extended reality glasses in macular disease
Jing YUAN ; Xingchang WANG ; Xiquan SUN ; Huiguang JIAO ; Qian WANG ; Yanxia TONG ; Biyue TU ; Xixi YAN ; Zhen ZHAO ; Xiaojie OU ; Sawut ABDULLA
Chinese Journal of Experimental Ophthalmology 2025;43(11):1035-1040
Objective:To evaluate the application effect of a wearable visual field meter based on extended reality (XR) glasses for patients with macular disease.Methods:A self-controlled study was conducted.A total of 41 consecutive patients (41 eyes) with macular disease were recruited at Renmin Hospital of Wuhan University from October 2022 to October 2024.All patients underwent 10-2 center visual field test using a self-developed wearable visual field meter (XRVF), and the results were compared with those obtained using a traditional Humphrey field analyzer (HFA).The comparison parameters included mean retinal sensitivity (MS), false positive rate (FPR), false negative rate (FNR), and testing duration.A subject satisfaction questionnaire was administered.This study followed the Declaration of Helsinki.The study protocol was approved by the Medical Ethics Committee of Renmin Hospital of Wuhan University (No.WDRY2024-K263), and all subjects signed the informed consent form.Results:The retinal sensitivity of patients measured by HFA was (23.24±3.71)dB, which was higher than (22.01±3.45)dB by XRVF, showing a statistically significant difference ( t=4.924, P=0.036).The FPR measured by HFA and XRVF were (2.39±2.51)% and (2.59±3.29)%, respectively, and the FNR were (3.49±6.05)% and (3.74±5.38)%, respectively, showing no statistically significant difference ( t=-3.624, P=0.948; t=-1.241, P=0.519).The median test duration for HFA and XRVF was 6.15 (5.78, 6.65) and 5.98 (5.71, 6.69)minutes, respectively, without statistically significant difference ( Z=-1.987, P=0.953).92.6% of the subjects thought the device was comfortable, simple and practical. Conclusions:The XRVF has good consistency with the HFA, can effectively and reliably evaluate the visual field function of patients with macular disease, and is easily accepted by patients.
3.Importance of preoperative ultrasound and D-dimer determination for patients with traumatic fractures
Jinyan OU ; Xiaojie LIU ; Zhengjie WU ; Shu ZHOU
Chinese Journal of Trauma 2010;26(8):706-708
Objective To retrospectively analyze the importance of preoperative ultrasound and D-dimer determination for patients with traumatic fractures so as to evaluate the value of vascular color Doppler ultrasound in diagnosing of vein thrombosis and the correlation between D-dimer level and lower extremity vein thrombosis. Methods The study involved 1000 in-patients with multiple traumatic fractures, femoral fractures, tibial fractures or tibiofibular fractures admitted from March 2008 to April 2009 who were prepared for open reduction surgery. There were 568 males and 432 females, at age range of 20-90 years ( average 54.8 years). Vein D-dimer was examined in the morning on the second day after admission. Vascular color Doppler ultrasound was performed on the lower extremity one day before operation (after the swelling faded away, about 4-10 days after fracture). Results The vascular color Doppler ultrasound on the lower extremity showed vein thrombosis of the lower extremity in 64 patients (6.4%) including 26 patients with iliac- femoral vein thrombosis, 10 with popliteal-tibial vein thrombosis and 28 with gastrocnemius or soleus muscle vein thrombosis. On the second day after operation, out of 736 patients (73.6%) with D-dimer above normal (324 μg/L), 56 patients (7.6%) developed thrombosis afterwards;of 264 patients (26.4%) with normal D-dimer, eight patients (3.03%) developed thrombsis. Incidence of thrombosis in patients with D-dimer above 650 μg/L was higher than that in patients with D-dimer below 650 μg/L (P<0. 01). Conclusions Preoperative lower extremity vein Doppler ultrasound in traumatic fracture patients can lower the risk of fatal lung thrombosis caused by existing deep vein thrombosis.D-dimer above normal level indicates tendency of thorombosis. However, normal D-dimer still have the possibility to develop thrombosis, which deserves attention.
4.Effect of combined chemotherapy including Navelbine in the treatment of 39 cases of advanced non-small cell lung cancer
Xiaojie PAN ; Debin OU ; Ronglong WU ;
China Oncology 2001;0(02):-
Purpose:To study the effect of NVB in the treatment of advanced non small cell lung cancer (NSCLC).Methods:In 39 cases advanced stage, primary chemotherapy patients account for 30 cases and 9 were recurrent diseases.Results:CR 2 cases PR 20 cases NC 13 cases and PD 4 cases, total response rate 56.4%. The majory toxicity was bone marrow suppression.Conclusions:Combined chemotherapy including NVB has better curative effect for advanced NSCLC.

Result Analysis
Print
Save
E-mail