1.Effects of CO2 intracavitary laser combined with pelvic floor magnetic stimulation on surface electromyography of pelvic floor muscle and three-dimensional ultrasound parameters of pelvic floor in patients with female stress urinary incontinence
Tao HOU ; Li CHEN ; Shan HE ; Ping ZHOU ; Qijun ZHONG ; Xiaohu LI ; Hua ZHAO ; Yang CHEN ; Yanmei GUO
China Medical Equipment 2025;22(5):87-92
Objective:To investigate the effects of CO2 intracavitary laser combined with pelvic floor magnetic stimulation on surface electromyography(sEMG)values and pelvic floor three-dimensional ultrasound parameters in female patients with stress urinary incontinence(SUI).Methods:A prospective study was conducted on 92 female SUI patients treated at the outpatient department of Meizhou People's Hospital from October 2021 to July 2023.The patients were randomly divided into an observation group and a control group(n=46 each)using a random number table.Both groups received home-based pelvic floor muscle training.The control group additionally received pelvic floor magnetic stimulation,while the observation group was treated with CO2 intracavitary laser combined with pelvic floor magnetic stimulation.The urinary leakage status,treatment efficacy,pelvic floor muscle sEMG,pelvic floor three-dimensional ultrasound parameters,quality of life,and sexual quality of life were compared between the two groups.Assessments included the International Consultation on Incontinence Questionnaire-Short Form(ICIQ-SF),the Incontinence Impact Questionnaire-Short Form(IIQ-7),and the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire(PISQ-12).Results:1-hour leakage volume:0 g(observation group)vs.3 g(control group),24-hour leakage episodes:0 times(observation group)vs.0 times(control group),the observed differences were statistically significant(Z=-2.866,-2.355,P<0.05).Total effective rate:95.65%(observation)vs.58.70%(control),the observed differences were statistically significant(x2=4.083,P<0.05).Pelvic floor muscle sEMG(after treatment):Maximal fast contraction:(40.78±3.28)μV(observation)vs.(35.17±5.10)μV(control),Mean tonic contraction:(31.56±4.20)μV(observation)vs.(25.87±3.82)μV(control),Mean endurance contraction:(29.34±2.58)μV(observation)vs.(25.37±2.67)μV(control),all differences between the two groups were statistically significant(t=2.736,19.919,3.025,15.426,P<0.05).After treatment,both groups showed reductions in bladder neck descent(BND)during Valsalva maneuver,bladder-symphysis distance(BSD),urethral rotation angle(URA),and posterior vesicourethral angle(RVA).However,the observation group demonstrated significantly greater reductions compared to the control group(post-treatment data:observation group(24.30±3.21)mm,(2.34±0.23)mm,(56.40±5.87)°,(89.54±9.21)°;control group(26.21±3.48)mm,(3.57±0.35)mm,(60.29±6.45)°,(126.71±13.50)°.These differences were statistically significant(t=2.736,19.919,3.025,15.426,P<0.05).Similarly,both groups exhibited decreased scores on the ICIQ-SF and IIQ-7 scales,along with increased scores on the PISQ-12.Again,the observation group showed superior improvement,with statistically significant differences(t=11.478,13.168,6.631,P<0.05).Conclusion:On the basis of pelvic floor muscle training,CO2 intracavitary laser therapy combined with pelvic floor magnetic stimulation can effectively alleviate urinary incontinence symptoms in patients with female stress urinary incontinence(FSUI),enhance therapeutic efficacy,improve pelvic floor muscle strength and the stability of pelvic support structures,and promote quality of life and sexual function.
2.Impact of sublingual nitroglycerin on imaging quality of non-contrast MR coronary angiography
Xiankuo HU ; Yang ZHANG ; Yushan YUAN ; Lei ZHANG ; Peiqi MA ; Xiaohu LI
Chinese Journal of Medical Imaging Technology 2025;41(10):1730-1734
Objective To observe the impact of sublingual nitroglycerin(NTG)on imaging quality of non-contrast MR coronary angiography(NMRCA).Methods Thirty patients with suspected coronary heart disease(CHD)who would undergo coronary angiography(CAG)examination were prospectively collected.NMRCA images were acquired before and after sublingual NTG.Clinical meaningful stenosis was defined as CAG showed luminal stenosis ≥50%.Then imaging quality scores,diameters and display length of coronary arteries,as well as the impact of NTG on diagnostic performances of NMRCA for coronary artery stenosis were compared between images before and after administration of NTG.Results After administration of NTG,image quality of left main(LM)-left anterior descending artery(LAD)and left circumflex artery(LCX),as well as the proximal,mid and distal segments of LAD and distal segment of LCX significantly improved(all P<0.05).No significant difference of visible coronary artery length was noticed before and after administration of NTG(all P>0.05).After administration of NTG,diameter of right coronary artery(RCA),LM-LAD and LCX increased(all P<0.05),with dilation rate of 16.23%(13.57%,19.17%),17.52%(12.69%,21.11%)and 14.30%(7.62%,23.22%),respectively,while the sensitivity,specificity,accuracy and negative predictive value of NMRCA for diagnosing coronary artery stenosis improved(all P<0.05).Conclusion Sublingual NTG could improve imaging quality of NMRCA and increase its efficacy for diagnosing coronary artery stenosis.
3.Evaluation of traditional Chinese medicine apprenticeship education in Chinese herbal curriculum of western medical institutions
Dan YANG ; Qunli WU ; Yi LIU ; Xiaohu SHI ; Lan JIANG ; Yamin ZHANG
Basic & Clinical Medicine 2025;45(6):838-840
Objective To explore the application and effectiveness of the apprenticeship education model in Chinese herbal medicine teaching at Western medical college.Methods By comparing classic lecture-based teaching with a combined approach integrating apprenticeship education,the study assesses the impact on student learning outcomes.Participants included students from the 2018 cohort of the eight-year clinical medicine program and the 2022 cohort of the"4+4"pilot program at Peking Union Medical College,who received classic teaching methods and apprenticeship case-based teaching methods,respectively.Upon course completion,students completed a 14-item multiple-choice questionnaire covering essential theory of Chinese medicine,as well as specific categories such as qi-regulating,blood-activating herbs,among others.Results The overall accuracy rate in the apprenticeship case-based teaching group was significantly higher than that in the classic teaching group(P<0.01).Conclusions The apprenticeship education model of Traditional Chinese Medicine has a positive effect on teaching of Chinese herbal medicine at West-ern medical college and warrants further promotion and application.
4.Evaluation of apprenticeship case-based teaching in traditional Chinese medicine formulas instruction for nursing
Yue SHI ; Dan YANG ; Qunli WU ; Guangchan JING ; Yi LIU ; Qing SUN ; Xiaohu SHI
Basic & Clinical Medicine 2025;45(9):1258-1260
Objective To explore the effectiveness of the"apprenticeship case-based teaching"method in the in-struction of traditional Chinese medicine(TCM)formulas for nursing students.Methods A quasi-experimental study was conducted with 135 undergraduate nursing students from the 2023 cohort at Peking Union Medical Col-lege.Participants were randomly assigned to an experimental group(receiving apprenticeship case-based teaching)or a control group(receiving conventional teaching).Teaching effectiveness was evaluated through classroom in-struction followed by a routine test.The test covered the indications and key diagnostic points of eight representative TCM formulas.Results The experimental group overruns the control group on most test items.Statistically signifi-cant differences(P<0.05)were observed in questions related to Ma Huang Tang,Xiao Chai Hu Tang,Da Cheng Qi Tang,Liu Wei Di Huang Wan,and Ba Zheng San.Conclusions The apprenticeship case-based teaching meth-od significantly enhances students'learning gain about key diagnostic principles in TCM formulas and improves ca-pacity building of clinical reasoning.This method should be shared by schools of nursing in the teaching reformation of TCM curriculum.
5.Status Analysis of Acupoint Selection and Stimulation Parameters Application for Acupuncture Treatment of Functional Dyspepsia
Siyi ZHENG ; Han ZHANG ; Yang YU ; Chuanlong ZHOU ; Yan SHI ; Xiaohu YIN ; Shouhai HONG ; Na NIE ; Jianqiao FANG ; Yi LIANG
Journal of Traditional Chinese Medicine 2025;66(12):1293-1299
Based on commonly used acupoints in the clinical acupuncture treatment of functional dyspepsia (FD), this study systematically analyzes the therapeutic differences and synergistic effects between local and distal point selection. It also examines the suitability of primary acupoint selection for different FD subtypes, postprandial distress syndrome (PDS) and epigastric pain syndrome (EPS). The findings suggest that a combination of local and distal acupoints may be more appropriate as primary points for PDS, whereas local acupoints alone may be more suitable for EPS. Additionally, the study explores the impact of various factors, such as stimulation techniques, needling order, intensity or stimulation parameters, and depth, on the efficacy of acupuncture. It concludes that the intrinsic properties of acupoints are the primary determinants of therapeutic direction. Other factors mainly influence the magnitude rather than the direction of the effect. Future research may further investigate how different acupoint combinations, local versus distal, affect the treatment outcomes of FD subtypes, providing new insights for clinical acupuncture prescriptions.
6.A clinical study of deep learning image reconstruction algorithms in liver dual-energy CT with reduced radiation dose to further improve image quality and lesion diagnostic confidence
Yuncheng LI ; Yuguo LI ; Junlin YANG ; Jian SONG ; Xing TANG ; Wei DENG ; Zhen WANG ; Jinxiu YANG ; Bin LIU ; Yongqiang YU ; Xiaohu LI
Chinese Journal of Radiology 2025;59(1):43-49
Objective:To explore the feasibility of applying deep learning image reconstruction (DLIR) in low-radiation dose liver dual-energy CT to further improve image quality, diagnostic confidence of lesion, and accuracy of iodine concentration (IC) measurement.Methods:This prospective cohort study enrolled 60 patients scheduled for enhanced liver CT at the First Affiliated Hospital of Anhui Medical University from June 2023 to January 2024. The participants were randomly assigned into the standard dose group and low radiation dose group with 30 cases in each using randomized block method. The standard radiation dose group underwent standard-radiation dose 120 kVp scans during the venous phase, while the low radiation dose group underwent low radiation dose scans with a rapid kVp-switching spectral scanning mode at 80 kVp and 140 kVp. The effective radiation dose (ED) was calculated for both groups. The standard radiation dose group was reconstructed using adaptive statistical iterative reconstruction-V (ASIR-V) algorithm 40% (AR40 120 kVp). The low radiation dose group using high-intensity DLIR (DLIR-H) to reconstructed 40 keV and 50 keV virtual monoenergetic images (VMI) (DH-VMI 40 keV, DH-VMI 50 keV). The image quality of the above three groups was objectively evaluated through the measurement of image noise and calculation of contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) for the liver and portal vein; and the image quality was subjectively scored for image noise, contrast, lesion conspicuity, and diagnostic confidence. In the low radiation dose group, DLIR-H and ASIR-V40% reconstructed iodine maps were used to measure the liver and portal vein of IC values, standard deviations (SD), and coefficients of variation (CV). One-way analysis of variance or Kruskal-Wallis H test was used to compare the differences of subjective and objective image quality among the three groups, and paired t-test was used to compare the differences in measurement indexes between DLIR-H and ASIR-V40% reconstructed iodine maps. Results:The ED in the low radiation dose group [(2.2±0.5) mSv] was reduced by 56.8% compared to the conventional radiation dose group [(5.4±1.4) mSv]. Objective evaluations demonstrated that DH-VMI 40 keV had higher image noise, CNR, and SNR for liver and portal veins compared to AR40 120 kVp ( P<0.001). DH-VMI 50 keV had lower image noise ( P=0.200), with higher CNR and SNR for the liver and portal vein compared to AR40 120 kVp( P<0.001). In subjective evaluation, there was no statistically significant difference in image noise scores between DH-VMI 40 keV and AR40 120 kVp ( P>0.05), while the image noise score for DH-VMI 50 keV was lower than that of AR40 120 kVp ( P<0.05). Both DH-VMI 40 keV and DH-VMI 50 keV had higher scores for contrast, lesion conspicuity, and diagnostic confidence compared to those of AR40 120 kVp ( P<0.05). In the low radiation dose group, there was no statistically significant difference in IC values for the liver and portal vein between the ASIR-V40% and DLIR-H algorithm reconstructed iodine maps ( P>0.05). The SD and CV of liver and portal vein in the DLIR-H reconstructed iodine maps were lower than those in the ASIR-V40% reconstructed iodine maps ( P<0.001). Conclusions:DLIR can effectively reduce the image noise of low-energy (40, 50 keV) VMI, enhance lesion conspicuity and diagnostic confidence, and improve measurement accuracy without affecting IC values.
7.Effects of CO2 intracavitary laser combined with pelvic floor magnetic stimulation on surface electromyography of pelvic floor muscle and three-dimensional ultrasound parameters of pelvic floor in patients with female stress urinary incontinence
Tao HOU ; Li CHEN ; Shan HE ; Ping ZHOU ; Qijun ZHONG ; Xiaohu LI ; Hua ZHAO ; Yang CHEN ; Yanmei GUO
China Medical Equipment 2025;22(5):87-92
Objective:To investigate the effects of CO2 intracavitary laser combined with pelvic floor magnetic stimulation on surface electromyography(sEMG)values and pelvic floor three-dimensional ultrasound parameters in female patients with stress urinary incontinence(SUI).Methods:A prospective study was conducted on 92 female SUI patients treated at the outpatient department of Meizhou People's Hospital from October 2021 to July 2023.The patients were randomly divided into an observation group and a control group(n=46 each)using a random number table.Both groups received home-based pelvic floor muscle training.The control group additionally received pelvic floor magnetic stimulation,while the observation group was treated with CO2 intracavitary laser combined with pelvic floor magnetic stimulation.The urinary leakage status,treatment efficacy,pelvic floor muscle sEMG,pelvic floor three-dimensional ultrasound parameters,quality of life,and sexual quality of life were compared between the two groups.Assessments included the International Consultation on Incontinence Questionnaire-Short Form(ICIQ-SF),the Incontinence Impact Questionnaire-Short Form(IIQ-7),and the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire(PISQ-12).Results:1-hour leakage volume:0 g(observation group)vs.3 g(control group),24-hour leakage episodes:0 times(observation group)vs.0 times(control group),the observed differences were statistically significant(Z=-2.866,-2.355,P<0.05).Total effective rate:95.65%(observation)vs.58.70%(control),the observed differences were statistically significant(x2=4.083,P<0.05).Pelvic floor muscle sEMG(after treatment):Maximal fast contraction:(40.78±3.28)μV(observation)vs.(35.17±5.10)μV(control),Mean tonic contraction:(31.56±4.20)μV(observation)vs.(25.87±3.82)μV(control),Mean endurance contraction:(29.34±2.58)μV(observation)vs.(25.37±2.67)μV(control),all differences between the two groups were statistically significant(t=2.736,19.919,3.025,15.426,P<0.05).After treatment,both groups showed reductions in bladder neck descent(BND)during Valsalva maneuver,bladder-symphysis distance(BSD),urethral rotation angle(URA),and posterior vesicourethral angle(RVA).However,the observation group demonstrated significantly greater reductions compared to the control group(post-treatment data:observation group(24.30±3.21)mm,(2.34±0.23)mm,(56.40±5.87)°,(89.54±9.21)°;control group(26.21±3.48)mm,(3.57±0.35)mm,(60.29±6.45)°,(126.71±13.50)°.These differences were statistically significant(t=2.736,19.919,3.025,15.426,P<0.05).Similarly,both groups exhibited decreased scores on the ICIQ-SF and IIQ-7 scales,along with increased scores on the PISQ-12.Again,the observation group showed superior improvement,with statistically significant differences(t=11.478,13.168,6.631,P<0.05).Conclusion:On the basis of pelvic floor muscle training,CO2 intracavitary laser therapy combined with pelvic floor magnetic stimulation can effectively alleviate urinary incontinence symptoms in patients with female stress urinary incontinence(FSUI),enhance therapeutic efficacy,improve pelvic floor muscle strength and the stability of pelvic support structures,and promote quality of life and sexual function.
8.Impact of sublingual nitroglycerin on imaging quality of non-contrast MR coronary angiography
Xiankuo HU ; Yang ZHANG ; Yushan YUAN ; Lei ZHANG ; Peiqi MA ; Xiaohu LI
Chinese Journal of Medical Imaging Technology 2025;41(10):1730-1734
Objective To observe the impact of sublingual nitroglycerin(NTG)on imaging quality of non-contrast MR coronary angiography(NMRCA).Methods Thirty patients with suspected coronary heart disease(CHD)who would undergo coronary angiography(CAG)examination were prospectively collected.NMRCA images were acquired before and after sublingual NTG.Clinical meaningful stenosis was defined as CAG showed luminal stenosis ≥50%.Then imaging quality scores,diameters and display length of coronary arteries,as well as the impact of NTG on diagnostic performances of NMRCA for coronary artery stenosis were compared between images before and after administration of NTG.Results After administration of NTG,image quality of left main(LM)-left anterior descending artery(LAD)and left circumflex artery(LCX),as well as the proximal,mid and distal segments of LAD and distal segment of LCX significantly improved(all P<0.05).No significant difference of visible coronary artery length was noticed before and after administration of NTG(all P>0.05).After administration of NTG,diameter of right coronary artery(RCA),LM-LAD and LCX increased(all P<0.05),with dilation rate of 16.23%(13.57%,19.17%),17.52%(12.69%,21.11%)and 14.30%(7.62%,23.22%),respectively,while the sensitivity,specificity,accuracy and negative predictive value of NMRCA for diagnosing coronary artery stenosis improved(all P<0.05).Conclusion Sublingual NTG could improve imaging quality of NMRCA and increase its efficacy for diagnosing coronary artery stenosis.
9.A clinical study of deep learning image reconstruction algorithms in liver dual-energy CT with reduced radiation dose to further improve image quality and lesion diagnostic confidence
Yuncheng LI ; Yuguo LI ; Junlin YANG ; Jian SONG ; Xing TANG ; Wei DENG ; Zhen WANG ; Jinxiu YANG ; Bin LIU ; Yongqiang YU ; Xiaohu LI
Chinese Journal of Radiology 2025;59(1):43-49
Objective:To explore the feasibility of applying deep learning image reconstruction (DLIR) in low-radiation dose liver dual-energy CT to further improve image quality, diagnostic confidence of lesion, and accuracy of iodine concentration (IC) measurement.Methods:This prospective cohort study enrolled 60 patients scheduled for enhanced liver CT at the First Affiliated Hospital of Anhui Medical University from June 2023 to January 2024. The participants were randomly assigned into the standard dose group and low radiation dose group with 30 cases in each using randomized block method. The standard radiation dose group underwent standard-radiation dose 120 kVp scans during the venous phase, while the low radiation dose group underwent low radiation dose scans with a rapid kVp-switching spectral scanning mode at 80 kVp and 140 kVp. The effective radiation dose (ED) was calculated for both groups. The standard radiation dose group was reconstructed using adaptive statistical iterative reconstruction-V (ASIR-V) algorithm 40% (AR40 120 kVp). The low radiation dose group using high-intensity DLIR (DLIR-H) to reconstructed 40 keV and 50 keV virtual monoenergetic images (VMI) (DH-VMI 40 keV, DH-VMI 50 keV). The image quality of the above three groups was objectively evaluated through the measurement of image noise and calculation of contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) for the liver and portal vein; and the image quality was subjectively scored for image noise, contrast, lesion conspicuity, and diagnostic confidence. In the low radiation dose group, DLIR-H and ASIR-V40% reconstructed iodine maps were used to measure the liver and portal vein of IC values, standard deviations (SD), and coefficients of variation (CV). One-way analysis of variance or Kruskal-Wallis H test was used to compare the differences of subjective and objective image quality among the three groups, and paired t-test was used to compare the differences in measurement indexes between DLIR-H and ASIR-V40% reconstructed iodine maps. Results:The ED in the low radiation dose group [(2.2±0.5) mSv] was reduced by 56.8% compared to the conventional radiation dose group [(5.4±1.4) mSv]. Objective evaluations demonstrated that DH-VMI 40 keV had higher image noise, CNR, and SNR for liver and portal veins compared to AR40 120 kVp ( P<0.001). DH-VMI 50 keV had lower image noise ( P=0.200), with higher CNR and SNR for the liver and portal vein compared to AR40 120 kVp( P<0.001). In subjective evaluation, there was no statistically significant difference in image noise scores between DH-VMI 40 keV and AR40 120 kVp ( P>0.05), while the image noise score for DH-VMI 50 keV was lower than that of AR40 120 kVp ( P<0.05). Both DH-VMI 40 keV and DH-VMI 50 keV had higher scores for contrast, lesion conspicuity, and diagnostic confidence compared to those of AR40 120 kVp ( P<0.05). In the low radiation dose group, there was no statistically significant difference in IC values for the liver and portal vein between the ASIR-V40% and DLIR-H algorithm reconstructed iodine maps ( P>0.05). The SD and CV of liver and portal vein in the DLIR-H reconstructed iodine maps were lower than those in the ASIR-V40% reconstructed iodine maps ( P<0.001). Conclusions:DLIR can effectively reduce the image noise of low-energy (40, 50 keV) VMI, enhance lesion conspicuity and diagnostic confidence, and improve measurement accuracy without affecting IC values.
10.Influence of Spin-Lock Frequency on Quantitative Assessment of Myocardial T1ρ Mapping
Caiyun HAN ; Wei DENG ; Ren ZHAO ; Hongmin SHU ; Zhen WANG ; Jinxiu YANG ; Yongqiang YU ; Xiaohu LI
Chinese Journal of Medical Imaging 2024;32(7):731-735
Purpose To explore the influence of different spin-locking frequencies on T1ρ values based on a 3.0T MR system.Materials and Methods Thirty-eight healthy adult volunteers underwent cardiac magnetic resonance imaging at the First Affiliated Hospital of Anhui Medical University from July to September 2023.T1ρ mapping and short-axis cine imaging with steady-state free precession sequences were performed with 3.0T MR system.T1ρ mapping sequence in three short-axis slices with three spin-lock frequencies at the amplitude of 5 Hz,300 Hz,400 Hz,and 500 Hz was scanned,respectively.T1ρ relaxation times and myocardial fibrosis index were quantified for each slice and each myocardial segment,the difference in T1ρ of different spin-locking frequencies and myocardial fibrosis index was analyzed using one-way repeated-measures analysis of variance method.Results T1ρ of 5 Hz,300 Hz,400 Hz,and 500 Hz were(33.9±2.8)ms,(43.4±2.1)ms,(45.4±2.6)ms and(46.5±2.4)ms,respectively;and T1ρ values showed a significant progressive increase from the low spin-lock frequency to the high spin-lock frequency of the heart(300 Hz vs.400 Hz:P<0.001;300 Hz vs.500 Hz:P<0.001;400 Hz vs.500 Hz:P=0.043).In addition,the measured myocardial fibrosis index at 300 Hz,400 Hz and 500 Hz were(9.4±2.2)ms,(11.3±2.9)ms and(12.6±2.7)ms,respectively.Statistical analysis underscored significant variations among these measurements(300 Hz vs.400 Hz:P<0.001;300 Hz vs.500 Hz:P<0.001;400 Hz vs.500 Hz:P=0.033).Conclusion In this prospective study,myocardial T1ρ values for the specific cardiac magnetic resonance setting are provided,and we found that spin-lock frequency can affect the T1ρ values.

Result Analysis
Print
Save
E-mail