1.Xiaoyaosan Regulates HPT Axis in Rat Model with Syndrome of Liver Depression and Spleen Deficiency via CGA/GPX2/TSHβ Pathway for Thyroid Hormone Synthesis
Fang WANG ; Ruxin YUAN ; Lingjin FAN ; Zongli CHEN ; Huaye XIAO ; Liqiang YANG ; Xiaohong LI ; Chuncheng ZHENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):1-10
ObjectiveTo explore the mechanism by which Xiaoyaosan regulates HPT axis dysfunction in the rat model with the syndrome of liver depression and spleen deficiency by observing its effect on the glycoprotein hormone α-subunit (CGA)/glutathione peroxidase 2 (GPX2)/thyroid-stimulating hormone β-subunit (TSHβ) pathway for thyroid hormone synthesis. MethodsSeventy-two male SD rats were randomized into six groups: normal, model, high-dose (16.7 g·kg-1), medium-dose (8.35 g·kg-1), and low-dose (4.175 g·kg-1) Xiaoyaosan, and fluoxetine (0.001 8 g·kg-1) groups, with 12 rats in each group. The rat model of liver depression and spleen deficiency was induced by chronic restraint stress for 21 days. The intervention groups were treated with Xiaoyaosan decoctions or fluoxetine suspension, respectively. After modeling, hematoxylin-eosin staining was employed to observe morphological changes in the thyroid and pituitary tissue of the rats. Serum levels of triiodothyronine (T3), tetraiodothyronine (T4), and thyroid-stimulating hormone (TSH) were measured by enzyme-linked immunosorbent assay (ELISA). Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) and Western blot were employed to determine the mRNA and protein levels, respectively, of TSH receptor (TSHR) in the thyroid tissue, thyrotropin-releasing hormone receptor (TRHR) and TSHβ in the pituitary tissue, and thyrotropin-releasing hormone (TRH), CGA, GPX2, and TSHβ in the hypothalamic tissue. ResultsCompared with the normal group, the model group showed significant atrophy and irregularity of thyroid follicles, a marked reduction in colloid secretion, extensive vacuolar degeneration of adenocytes in the anterior pituitary, lowered serum levels of T3, T4, and TSH (P<0.01), and down-regulated mRNA and protein levels of TSHR in the thyroid tissue, TRHR and TSHβ in the pituitary tissue, and TRH, CGA, GPX2, and TSHβ in the hypothalamic tissue (P<0.01). Compared with the model group, high- and medium-dose Xiaoyaosan and fluoxetine alleviated the pathological changes in the thyroid and pituitary tissue, outperforming the low-dose Xiaoyaosan group. Moreover, they elevated the serum levels of T3, T4, and TSH (P<0.05, P<0.01). The serum TSH level was also elevated in the low-dose Xiaoyaosan group (P<0.05). The mRNA and protein levels of TSHR in the thyroid, TRHR and TSHβ in the pituitary, and TRH, CGA, GPX2, and TSHβ in the hypothalamus were up-regulated in the high- and medium-dose Xiaoyaosan groups (P<0.05, P<0.01). Additionally, the mRNA and protein levels of TSHβ in the hypothalamus were up-regulated in the low-dose Xiaoyaosan group (P<0.01). In the fluoxetine group, the mRNA and protein levels of TSHR in the thyroid, TRHR in the pituitary, and TRH, CGA, and GPX2 in the hypothalamus were up-regulated (P<0.05, P<0.01). ConclusionThe downregulation of CGA/GPX2/TSHβ pathway may be one of the biological mechanisms underlying HPT axis dysfunction in the rat model with the syndrome of liver depression and spleen deficiency. Xiaoyaosan may regulate the HPT axis dysfunction by up-regulating the CGA/GPX2/TSHβ pathway.
2.Pathogen spectrum of diarrheal disease surveillance in Fengxian District, Shanghai, 2013‒2023
Meihua LIU ; Yuan ZHUANG ; Xiaohong XIE ; Hongwei ZHAO ; Yuan SHI ; Lijuan DING ; Yi HU ; Lixin TAO
Shanghai Journal of Preventive Medicine 2025;37(4):336-341
ObjectiveTo investigate the pathogenic spectrum and epidemiological characteristics of diarrheal disease in Fengxian District of Shanghai, and to provide scientific basis for the prevention and control of diarrheal diseases. MethodsBasic information of the initial adult cases visited diarrheal disease surveillance sentinel hospital in Fengxian District, Shanghai, was collected from August 2013 to 2023, and fecal samples were collected at 1∶5 sampling intervals to isolate and identify 5 kinds of diarrheagenic Escherichia coli (DEC), Salmonella (SAL), Vibrio parahaemolyticus, Campylobacter, Vibrio cholerae, Shigella and Yersinia enterocolitica (YE). Simultaneously, nucleic acid detection was performed for 3 kinds of rotavirus, 2 kinds of norovirus, intestinal adenovirus, astrovirus and sapovirus. ResultsA total of 1 861 cases of newly diagnosed diarrheal disease were reported, with the peak in July to August. Additionally, 704 surveillance samples were detected, with a total positive detection rate of 50.57%. The detection rates of bacterial, viral and mixed infection were 25.14%, 21.02% and 4.40%, respectively. Among the pathogens detected, DEC accounted for the highest (17.61%, 124/704), followed by norovirus (16.48%, 116/704), rotavirus (6.39%, 45/704), SAL (5.97%, 42/704) and Campylobacter (3.84%, 27/704). DEC detected were mainly enteroaggregative Escherichia coli and enterotoxigenic Escherichia coli, with no detection of Vibrio cholerae, Shigella and YE. The highest total pathogen detection rate was observed from June to September, and the detection peaks of norovirus were from March to June and from October to December, whereas that of DEC was from June to October. The detection rate of rotavirus peaked from January to February, but which was not detected between 2020‒2023. The SAL positive rate peak was in September, whereas that of Campylobacter was from July to September. ConclusionThe main pathogens detected in Fengxian District from 2013‒2019 are DEC, norovirus, rotavirus, SAL and Campylobacter. Different pathogens have different detection peaks, with bacteria predominating in summer and viruses in winter and spring. Prevention and control measures should be carried out according to the epidemiological characteristics of different seasons.
3.Qihuang needle therapy for autism spectrum disorder with sleep disorder: a multi-center randomized controlled trial.
Bingxu JIN ; Qizhen LIU ; Jiahao TANG ; Yong ZHAO ; Jing XIN ; Yuan ZHOU ; Haiyan CAI ; Zhanxin HUO ; Xiaohong CHEN ; Yan BAI
Chinese Acupuncture & Moxibustion 2025;45(3):322-326
OBJECTIVE:
To observe the clinical efficacy of Qihuang needle therapy for autism spectrum disorder (ASD) children with sleep disorder.
METHODS:
A total of 60 ASD children with sleep disorder were randomly divided into an observation group and a control group, 30 cases in each group. Both groups were treated with structured education intervention, 60 min each time, once a day, 6 times a week. Qihuang needle therapy was applied at Yintang (GV24+), Baihui (GV20) and bilateral Jueyinshu (BL14), Xinshu (BL15) in the observation group, multi-direction needling was delivered and without needle retaining. The treatment was given 2 times a week, each treatment was delivered at interval of 2 days at least. Behavioral intervention was adopted in the control group. Treatment for consecutive 12 weeks was required in both groups. Before and after treatment, the scores of children's sleep habits questionnaire (CSHQ), the autism behavior checklist (ABC), the childhood autism rating scale (CARS), and the childhood autism behavior scale (CABS) were observed in the two groups.
RESULTS:
After treatment, the scores of CSHQ, ABC, CARS and CABS were decreased compared with those before treatment (P<0.01), and the above scores in the observation group were lower than those in the control group (P<0.05).
CONCLUSION
Qihuang needle therapy can effectively treat ASD with sleep disorder, improve the core symptoms of ASD and the sleep quality.
Humans
;
Autism Spectrum Disorder/physiopathology*
;
Male
;
Female
;
Child
;
Sleep Wake Disorders/physiopathology*
;
Child, Preschool
;
Acupuncture Therapy
;
Acupuncture Points
;
Treatment Outcome
;
Sleep
;
Needles
4.The interval of rescue treatment does not affect the efficacy and safety of Helicobacter pylori eradication: A prospective multicenter observational study.
Minjuan LIN ; Junnan HU ; Jing LIU ; Juan WANG ; Zhongxue HAN ; Xiaohong WANG ; Zhenzhen ZHAI ; Yanan YU ; Wenjie YUAN ; Wen ZHANG ; Zhi WANG ; Qingzhou KONG ; Boshen LIN ; Yuming DING ; Meng WAN ; Wenlin ZHANG ; Miao DUAN ; Shuyan ZENG ; Yueyue LI ; Xiuli ZUO ; Yanqing LI
Chinese Medical Journal 2025;138(12):1439-1446
BACKGROUND:
The effect of the interval between previous Helicobacter pylori (H. pylori) eradication and rescue treatment on therapeutic outcomes remains unknown. The aim of this study was to investigate the association between eradication rates and treatment interval durations in H. pylori infections.
METHODS:
This prospective observational study was conducted from December 2021 to February 2023 at six tertiary hospitals in Shandong, China. We recruited patients who were positive for H. pylori infection and required rescue treatment. Demographic information, previous times of eradication therapy, last eradication therapy date, and history of antibiotic use data were collected. The patients were divided into four groups based on the rescue treatment interval length: Group A, ≥4 weeks and ≤3 months; Group B, >3 and ≤6 months; Group C, >6 and ≤12 months; and Group D, >12 months. The primary outcome was the eradication rate of H. pylori . Drug compliance and adverse events (AEs) were also assessed. Pearson's χ2 test or Fisher's exact test was used to compare eradication rates between groups.
RESULTS:
A total of 670 patients were enrolled in this study. The intention-to-treat (ITT) eradication rates were 88.3% (158/179) in Group A, 89.6% (120/134) in Group B, 89.1% (123/138) in Group C, and 87.7% (192/219) in Group D. The per-protocol (PP) eradication rates were 92.9% (156/168) in Group A, 94.5% (120/127) in Group B, 94.5% (121/128) in Group C, and 93.6% (190/203) in Group D. There was no statistically significant difference in the eradication rates between groups in either the ITT ( P = 0.949) or PP analysis ( P = 0.921). No significant differences were observed in the incidence of AEs ( P = 0.934) or drug compliance ( P = 0.849) between groups.
CONCLUSION:
The interval duration of rescue treatment had no significant effect on H. pylori eradication rates or the incidence of AEs.
REGISTRATION
ClinicalTrials.gov , NCT05173493.
Humans
;
Helicobacter Infections/drug therapy*
;
Helicobacter pylori/pathogenicity*
;
Male
;
Female
;
Prospective Studies
;
Middle Aged
;
Anti-Bacterial Agents/adverse effects*
;
Adult
;
Aged
;
Treatment Outcome
;
Proton Pump Inhibitors/therapeutic use*
5.Multi-modal cross-scale imaging technologies and their applications in plant network analysis.
Yining XIE ; Yuchen KOU ; Yanhui YUAN ; Jinbo SHEN ; Xiaohong ZHUANG ; Jinxing LIN ; Xi ZHANG
Chinese Journal of Biotechnology 2025;41(7):2559-2578
A complete plant body consists of elements on different scales, including microscopic molecules, mesoscopic multicellular structures, and macroscopic tissues and organs, which are interconnected to form complex biological networks. The growth and development of plants involve the regulation of elements on different scales and their biological networks, which requires the coordinated operation of multiple molecules, cells, tissues, and organs. It is difficult to reveal the essence of multi-level life activities by a single method or technology. In recent years, the development of various novel imaging technologies has provided new approaches for revealing the complex life activities in plants. Using multi-modal imaging technologies to study the cross-scale network connections of plants from the microscopic, mesoscopic, and macroscopic levels is crucial for understanding the complex internal connections behind biological functions. This paper first summarizes multi-modal cross-scale imaging technologies, three-dimensional reconstruction, and image processing methods, outlines the basic framework of cross-scale network connection properties, and then summarizes the applications of multi-modal imaging technologies in elucidating plant multi-scale networks. Finally, this review systematically integrates the combined analysis of cross-scale 3D spatial structural data and single-cell omics, laying a theoretical foundation for the innovation of novel plant imaging technologies. Furthermore, it provides a new research paradigm for in-depth exploration of the interaction mechanisms among cross-scale elements and the principles of biological network connectivity in plant life activities.
Plants/metabolism*
;
Imaging, Three-Dimensional/methods*
;
Image Processing, Computer-Assisted/methods*
;
Multimodal Imaging/methods*
;
Plant Physiological Phenomena
6."Spleen-gut-muscle" Model of Chinese Medicine to Explore Effect of Gut Microbiota on COPD with Sarcopenia
Wang TAO ; Peiyi WANG ; Jie SUN ; Xiaohong ZHANG ; Qin YUAN ; Qiulin ZHU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(20):186-193
Chronic obstructive pulmonary disease (COPD) is susceptible to systemic complications. Especially,sarcopenia is an independent risk factor for COPD patients that can exacerbate respiratory muscle fatigue,lead to a higher risk of falls and fractures,and lower the quality of life. The pathogenesis of sarcopenia involves such aspects as mitochondrial dysfunction,insulin resistance,changes in skeletal muscle fiber types,and an imbalance in protein synthesis and breakdown. As nutrition support and exercise rehabilitation therapy frequently have limited effectiveness,it is urgent to find a way to slow the progression of COPD with sarcopenia. Numerous studies conducted in recent years have discovered a potential link between pulmonary microbiome disorders and the gut microbiota of COPD patients. Furthermore,a wide range of functions of gut microbiota and its metabolites have been demonstrated,such as regulating inflammation and immunity,glucose and lipid metabolism,and mitochondrial function. According to the Zangxiang theory in Chinese medicine, there are intimate connections between the spleen, intestine,and muscle,and gut microbiota may be the most essential part of ameliorating "spleen governing muscle" and increasing muscle mass and strength. This study aims to expound on the effect mechanism of gut microbiota in slowing the progression of COPD with sarcopenia,thereby furnishing novel perspectives and recommendations for forthcoming investigations and therapeutic applications.
7.Finite element analysis of osteoporosis in proximal femur after cannulated screw fixation for femoral neck fracture
Xiaofeng XUE ; Yongkang WEI ; Xiaohong QIAO ; Yuyong DU ; Jianjun NIU ; Lixin REN ; Huifeng YANG ; Zhimin ZHANG ; Yuan GUO ; Weiyi CHEN
Chinese Journal of Tissue Engineering Research 2024;28(6):862-867
BACKGROUND:After the internal fixation of cannulated screws in femoral neck fractures,because the affected limb is often unable to bear weight in the short term and the implants with high stiffness have a stress shielding effect on the fracture end,it is easy to cause osteoporosis of the affected limb and changes in the biomechanical distribution of the proximal femur,the incidence of osteonecrosis of the femoral head is high after surgery.At present,few studies have been conducted on the biomechanical effects of osteoporosis at the proximal end of the femur occurring after femoral neck fracture surgery on femoral neck fracture treated with cannulated screws. OBJECTIVE:Using finite element analysis,to investigate the biomechanical effects of osteoporosis occurring after femoral neck fracture surgery on femoral neck fracture treated with cannulated screws and explore the role of biomechanical factors in osteonecrosis of the femoral head. METHODS:Based on the obtained CT scan data of the femur in a patient with a femoral neck fracture,a proximal femoral model for internal fixation for femoral neck fracture was established by Mimics 19.0,3-Matic,UG 11.0,Hypermesh 14.0,and Abaqus software.One finite element model of the proximal femur without osteoporosis and three finite element models of the proximal femur with osteoporosis were analyzed using Abaqus software.The stress,contact pressure,displacement peak and cloud map under different components of the four models were measured and analyzed,and the internal stress changes and distribution of the femoral head were compared and analyzed. RESULTS AND CONCLUSION:The stresses and contact pressures of the femoral head and lower anterior cannulated screws varied more with the degree of osteoporosis.The peak displacement of the four models increased slowly with the degree of osteoporosis.By one-way analysis of variance,there was no significant effect of the degree of osteoporosis on the peak stress,contact pressure,and displacement of the different components.The internal stress distribution of the femoral head changed with the degree of osteoporosis.Changes in the biomechanical environment of the proximal femur have an important impact on osteonecrosis of the femoral head.
8.Drug resistance and homology of diarrheagenic Escherichia coli in sentinel hospital of Fengxian District of Shanghai, 2019‒2022
Hongwei ZHAO ; Xiaohong XIE ; Lixin TAO ; Li SHEN ; Chunli SHEN ; Meihua LIU ; Yuan SHI ; Huangfei SHENG
Shanghai Journal of Preventive Medicine 2024;36(4):352-358
ObjectiveWe conducted a drug resistance and homology analysis of diarrheagenic Escherichia coli (DEC) in Fengxian District of Shanghai in order to provide a basis for clinical rational drug use, risk monitoring and early warning. MethodsDEC were isolated from diarrheal patients in Fengxian District, Shanghai from 2019 to 2022. The minimum inhibitory concentrations (MIC) of 21 drugs to the DEC were determined. Genotyping and homology analysis were conducted with pulsed-field gel electrophoresis (PFGE). ResultsThe DEC detection rate of diarrhea cases was 18.99% (131/690), including enteroaggregative E.coli (EAEC) 64.89% (85/131), enterotoxigenic E.coli (ETEC) 22.14% (29/131), enteropathogenic E.coli (EPEC) 12.21% (16/131), and enterohemorrhagic E.coli (EHEC) 0.76%(1/131). The DEC detection showed obvious seasonal characteristics with a high incidence in summer. The DEC multidrug resistance rate was 66.41% with a total of 65 drug resistance profiles. The five antimicrobial drugs with the highest resistance rate were ampicillin (60.31%), nalidixic acid (51.91%), cefazolin (50.38%), tetracycline (44.27%), and cotrimoxazole (35.11%). The rate of DEC resistance to levofloxacin was significantly increased from 2019 to 2022. Cluster analysis showed that the similarity of 85 EAEC cluster was 58.4%‒100.0%, and 69 band patterns were obtained. The similarity of 29 ETEC cluster was 58.5%‒100.0%, and 13 band patterns were obtained, including 2 dominant band types. The similarity of 16 EAEC clusters was 53.9%‒100.0%, and 15 band patterns were obtained. Five groups of homologous strains were found, consistent with the resistance phenotypes. ConclusionAmong the diarrhea cases, the DEC epidemic intensity is high, the drug resistance situation is severe, and the risk of outbreak infection is high in Fengxian District, Shanghai. Therefore, health monitoring and prevention need to be strengthened.
9.Investigation and analysis of energy release of cardiac defibrillator at different stages of lifecycle of that
Dong LI ; Xiaolong WANG ; Feng XIE ; Yukun WANG ; Yuan LIU ; Xiaohong LI ; Mei BAI
China Medical Equipment 2024;21(3):39-43
Objective:To analyze the performance characteristics of the energy output of defibrillation device at different lifecycle stages of the equipment,and to improve the level of management,so as to ensure the safety and effectiveness of using the device.Methods:A total of 90 defibrillation devices of using 10 types included 861290 and CardioServ(included scrapped devices)during the period of 2015-2022 were retrospectively analyzed.The detected data of energy output of defibrillation device were analyzed as statistical method,and the error of releasing energy was calculated.A total of 36 defibrillation devices that were in the early stages of use(at the first three years of device use)were divided into the first year,the second year and the third year,and the data of energy outputs of devices among three years were compared.The data of the type A and type B defibrillation devices,which were the largest number of devices in the normal stage of use(the middle stage of use),were calibrated according to the energy release in the three years between 2018 and 2000.The difference of releasing energy at the preseted value of 100J between the two types of devices was analyzed.Finally,the errors of energy releases of 8 devices,which energy outputs exceeded the deadline,in the scrap period between 2015 and 2022 were summarized.Results:In the data of three groups of devices in the early stages of use,the differences at the first and second year of device use among 100J,150J and 200J of the energy releases of the preseted values were significant(t=-0.17,-0.17,-0.58,P>0.05).The difference of the measured values between the first and third years of device use was not significant(Z=-0.70,-0.38,-0.86,P>0.05).The results of variance analysis of repeated measurement of the energy releases of the devices in normal stage indicated that the difference of the energy release at 100J preseted point among different types of 41 devices was significant(F=4.40,P<0.05).The energy release of type X defibrillator appeared constantly high,and the relative error increased with the increasing of preseted values.The repeatability of the device was better,and the relationship between preseted energy(x)and release energy(y)conformed to linear relationship(R2=0.9985).In these defibrillation devices that were using,the qualified rate of energy output of>100J preseted point was 97.68%.Conclusion:There is slight difference in the mean value of energy release between different type of defibrillation devices within the qualified range,and the energy release still is a performance indicator that should be highly focused for defibrillation devices.We should combine with the maintenance and repair data of device to conduct in-depth analysis,so as to grasp the operating status of the device,and optimize the strategy of quality control,and ensure the safety of defibrillator in clinical use.
10.Feasibility of acceptance of multiple accelerators using Elekta AGL standard procedures
Liang ZHAO ; Guiyuan LI ; Xiaohong WAN ; Xinyuan CHEN ; Kuo MEN ; Jianrong DAI ; Yuan TIAN
Chinese Journal of Radiation Oncology 2024;33(3):244-249
Objective:To verify the feasibility of using Elekta accelerated go live (AGL) standard process for the acceptance of multiple accelerators.Methods:The beams of three accelerators were adjusted by PTW Beamscan three-dimensional water tank to reach the AGL standard. Dose verification was performed for three accelerators that met AGL standards. A simple field test example from Cancer Hospital Chinese Academy of Medical Sciences was used to compare the MapCheck 3 surface dose measurement results with the surface dose calculated by the same accelerator model. Images of 10 patients including head and neck, esophagus, breast, lung and rectum were randomly selected. volumetric-modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) treatment techniques were used for planning design, and the measured dose of ArcCheck was compared with the planned dose calculated by the same accelerator model. One-way ANOVA was used to statistically analyze the passing rates of two-dimensional and three-dimensional dose verification.Results:The 6 MV X-ray percentage depth dose at 10 cm underwater (PDD 10) of three accelerators was 67.45%, 67.36%, 67.47%, and the maximum deviation between the three accelerators was 0.11%. The 6 MV flattenting filter free (FFF) mode X-ray PDD 10 was 67.33%, 67.20%, 67.20%, and the maximum deviation between the three accelerators was 0.13%. All required discrete point doses on each energy 30 cm×30 cm Profile spindle of the three accelerator X-rays deviated less than ±1% from the standard data. Absolute γ analysis was performed on the results of MapCheck 3 two-dimensional dose matrix validation. Under the 10% threshold of 2 mm/3% standard, the average passing rate of the test cases in Cancer Hospital Chinese Academy of Medical Sciences was above 99%, and the difference was not statistically significant ( P>0.05). Absolute γ analysis was performed on the ArcCheck verification results. Under the 10% threshold, the pass rate of 2 mm/3% was all above 95%, the maximum average passing rate of the three accelerators with different energy and different treatment techniques was 0.28% (6 MV, VMAT), 0.19%(6 MV FFF, VMAT), 0.56% (6 MV, IMRT) and 0.05% (6 MV FFF, IMRT), and the difference was not statistically significant ( P>0.05). Conclusion:Compared with traditional accelerator acceptance process, the acceptance time of each accelerator is shortened by 4-6 weeks by using the AGL standard process, and the radiotherapy plan of patients can be interchangeably executed among different accelerators.

Result Analysis
Print
Save
E-mail