1.Latent class analysis and influencing factor study of work-related musculoskeletal disorders among operating room nurses in tertiary hospitals
Xiaogui TANG ; Li LI ; Yue ZHAO ; Ningning HU ; Feng FU ; Boya LI ; Mengru YANG ; Yinglan LI
Journal of Environmental and Occupational Medicine 2025;42(3):293-301
Background Work-related musculoskeletal disorders (WMSDs), as one of the major occupational health issues worldwide, have shown an increasing positive rate year by year. Due to the unique demands of work, operating room nurses exhibit a higher positive rate of WMSDs compared to other occupational groups, necessitating active attention and intervention. Objective To estimate the prevalence of WMSDs among operating room nurses in tertiary hospitals, explore the characteristics and latent categories of WMSDs, and analyze the influencing factors associated with the occurrence of WMSDs. Method Using a randomized cluster sampling method, operating room nurses from nine tertiary hospitals in Urumqi were selected as study participants between December 2023 and January 2024. Data were collected through a general information questionnaire, an ergonomic questionnaire for operating room nurses, and the Chinese Musculoskeletal Disorders Questionnaire. Latent class analysis was employed to examine the patterns of WMSDs among the nurses, while chi-square test and multinomial logistic regression were utilized to analyze the influencing factors of WMSDs. Result A total of 411 valid questionnaires were collected in this survey. The positive rate of WMSDs among operating room nurses in the tertiary hospitals of Urumqi over the past year was 91.9%. The positive rates, ordered from highest to lowest by body region, were neck (79.1%), shoulders (70.3%), and lower back (68.1%). The operating room nurses were categorized into three distinct groups by latent class analysis: multi-site pain group, neck-shoulder-back pain group, and neck and lower back pain group. The results of the multinomial logistic regression models revealed that gender, job strain level, ergonomic load level in the operating room, and exposure to cold or drafty working conditions or not were significant influencing factors for reporting WMSDs among operating room nurses. Specifically, having less than 5 years of work experience, low ergonomic load level, low job strain, and moderate job strain were identified as protective factors against WMSDs. Conversely, exposure to cold or drafty working environments and being female were identified as risk factors for WMSDs. The logistic regression models also indicated that compared to the neck-lower back pain group, the neck-shoulder-back pain group had a higher probability of reporting low job strain (OR=0.168, 95%CI: 0.029, 0.968) and being female (OR=4.847, 95%CI: 2.506, 9.378). In contrast, when comparing to the neck-lower back pain group, the multi-site pain group had a higher probability of reporting, low-level ergonomic workload (OR=0.079, 95%CI: 0.015, 0.412), low job strain (OR=0.019, 95%CI: 0.002, 0.145), moderate job strain (OR=0.080, 95%CI: 0.016, 0.401), high job strain (OR=0.132, 95%CI: 0.027, 0.647), less than 5 years of work experience (OR=0.173, 95%CI: 0.044, 0.683), being female (OR=2.424, 95%CI: 1.130, 5.200), and exposure to cold or drafty working environments (OR=3.277, 95%CI: 1.657, 6.481). Conclusion The positive rate WMSDs among operating room nurses in tertiary hospitals is notably high in Urumqi, with distinct co-occurrence characteristics observed within the population. To mitigate the risk of WMSDs, it is essential to implement targeted health education and prevention training programs tailored to different patterns of WMSDs. Additionally, improving working conditions, optimizing human resource allocation , and other proactive measures should be undertaken. These efforts will effectively reduce the incidence of WMSDs among operating room nurses and safeguard their occupational health.
2.Research on classification management model based on Karajek matrix for ECG monitoring equipment in emergency ICU
Xi TANG ; Ting ZENG ; Wangsheng DENG ; Yanhua DU ; Ao LIU ; Yuquan DENG ; Jinfeng MENG ; Xiaogui QI ; Lili WU ; Wanrong ZHU
China Medical Equipment 2025;22(2):132-137
Objective:To construct a classification management model on the basis of Kraljic matrix for electrocardiogram(ECG)monitoring equipment in emergency intensive care unit(ICU),so as to explore its application value in the management for ECG monitoring equipment in emergency ICU.Methods:The classification management model on the basis of index for ECG monitoring equipment in emergency ICU was constructed.According to two classification dimensions included the market supply risk and the self-value,an indicator system of classification management,which aimed at strategic materials with high value and high risk,leverage materials with high value and low risk,bottleneck materials with low value and high risk,and conventional materials with low value and low risk,was constructed.A total of fifty-one ECG monitoring equipment in the emergency ICU of The People's Hospital of Longhua of Shenzhen from January to December 2023 were selected,and they were managed respectively by conventional management mode(25 sets)and classification management mode(26 sets)according to different management modes.The standardization level of operation management for equipment,the occurrence of safety risk and the level of management for equipment of the two management modes were compared,and the satisfaction of 30 relative personnel,who used and managed these equipment,for classification management of equipment also were compared.Results:The average values of the percentage of standardization level of normality of equipment operation,disinfection and sterilization,maintenance and fault repair of using classification management mode were respectively(91.58±4.33)%,(92.1±3.28)%,(91.49±3.54)%and(92.58±3.32)%,all of which were higher than those of conventional management mode,and the differences were statistically significant(t=12.537,15.706,14.196,18.946,P<0.05),repsectively.The average incidences of the risk of pressure injury,electrical injury and body fluid extravasation of adopting classification management mode were respectively(2.54±0.87)%,(3.02±0.82)%and(1.29±0.65)%,all of which were lower than those of adopting conventional management mode,and the differences were statistically significant(t=22.825,17.453,24.424,P<0.05),respectively.The satisfaction scores of 30 relative management personnel,who used equipment on the process rationality,system standardization and quality effectiveness,of adopting classification management mode were respectively(94.26±3.54),(92.57±4.36)and(91.87±3.69),all of which were higher than those of conventional management mode,and the differences were statistically significant(t=14.052,13.991,13.551,P<0.05),respectively.The reasonable placement rate,recording rate of standardization,and intact rate of equipment in the 26 equipment by adopting classification management mode were respectively 92.31%,92.31%and 88.46%,all of which were significantly higher than those by adopting conventional management mode,and the differences were statistical significant(x2=12.052,10.398,11.338,P<0.05).Conclusion:The classification management model of ECG monitoring equipment in emergency ICU can increase the management efficiency for the equipment in operating room of hospital,and improve the operation quality of equipment,and enhance the safety of equipment in clinical use,and the standardization of operation management for equipment.
3.Research on classification management model based on Karajek matrix for ECG monitoring equipment in emergency ICU
Xi TANG ; Ting ZENG ; Wangsheng DENG ; Yanhua DU ; Ao LIU ; Yuquan DENG ; Jinfeng MENG ; Xiaogui QI ; Lili WU ; Wanrong ZHU
China Medical Equipment 2025;22(2):132-137
Objective:To construct a classification management model on the basis of Kraljic matrix for electrocardiogram(ECG)monitoring equipment in emergency intensive care unit(ICU),so as to explore its application value in the management for ECG monitoring equipment in emergency ICU.Methods:The classification management model on the basis of index for ECG monitoring equipment in emergency ICU was constructed.According to two classification dimensions included the market supply risk and the self-value,an indicator system of classification management,which aimed at strategic materials with high value and high risk,leverage materials with high value and low risk,bottleneck materials with low value and high risk,and conventional materials with low value and low risk,was constructed.A total of fifty-one ECG monitoring equipment in the emergency ICU of The People's Hospital of Longhua of Shenzhen from January to December 2023 were selected,and they were managed respectively by conventional management mode(25 sets)and classification management mode(26 sets)according to different management modes.The standardization level of operation management for equipment,the occurrence of safety risk and the level of management for equipment of the two management modes were compared,and the satisfaction of 30 relative personnel,who used and managed these equipment,for classification management of equipment also were compared.Results:The average values of the percentage of standardization level of normality of equipment operation,disinfection and sterilization,maintenance and fault repair of using classification management mode were respectively(91.58±4.33)%,(92.1±3.28)%,(91.49±3.54)%and(92.58±3.32)%,all of which were higher than those of conventional management mode,and the differences were statistically significant(t=12.537,15.706,14.196,18.946,P<0.05),repsectively.The average incidences of the risk of pressure injury,electrical injury and body fluid extravasation of adopting classification management mode were respectively(2.54±0.87)%,(3.02±0.82)%and(1.29±0.65)%,all of which were lower than those of adopting conventional management mode,and the differences were statistically significant(t=22.825,17.453,24.424,P<0.05),respectively.The satisfaction scores of 30 relative management personnel,who used equipment on the process rationality,system standardization and quality effectiveness,of adopting classification management mode were respectively(94.26±3.54),(92.57±4.36)and(91.87±3.69),all of which were higher than those of conventional management mode,and the differences were statistically significant(t=14.052,13.991,13.551,P<0.05),respectively.The reasonable placement rate,recording rate of standardization,and intact rate of equipment in the 26 equipment by adopting classification management mode were respectively 92.31%,92.31%and 88.46%,all of which were significantly higher than those by adopting conventional management mode,and the differences were statistical significant(x2=12.052,10.398,11.338,P<0.05).Conclusion:The classification management model of ECG monitoring equipment in emergency ICU can increase the management efficiency for the equipment in operating room of hospital,and improve the operation quality of equipment,and enhance the safety of equipment in clinical use,and the standardization of operation management for equipment.

Result Analysis
Print
Save
E-mail