1.Expressions of miR-27a-3p mRNA and YAP1 mRNA in Breast Cancer and the Relationship With Clinicopathology and Survival Prognosis
Zhizhong LU ; Xiling LI ; Kai LI ; Siwei YANG ; Fuguo JIANG ; Shuai LI ; Haiyan SI ; Junmin LI ; Xiaoguang ZHAO
Journal of Sichuan University (Medical Sciences) 2025;56(2):521-527
Objective To analyze the expression levels of miR-27a-3p mRNA and Yes-associated protein 1(YAP1)mRNA in breast cancer,and to explore their relationships with clinicopathological features and the survival prognosis of patients.Methods A total of 130 breast cancer patients who underwent mastectomy in our hospital between January 2019 and January 2021 were enrolled.The expression levels of miR-27a-3p and YAP1 mRNA in breast tumor tissues and adjacent normal breast tissues were assessed by qRT-PCR.Furthermore,the relationships between their expression and clinicopathological features,as well as the survival prognosis of patients,were investigated.Results Compared with adjacent normal breast tissues,the expression of miR-27a-3p mRNA in breast tumor tissues was lower(P<0.05),while that of YAP1 mRNA was higher(P<0.05).A negative correlation was observed between the expression of miR-27a-3p mRNA and YAP1 mRNA in breast tumor tissues(r=-0.456,P<0.05).The expression of miR-27a-3p mRNA was correlated with tumor diameter,histological grade,tumor staging by the TNM system,lymph node metastasis,and vascular invasion in patients with breast cancer(P<0.05).The YAP1 mRNA expression was correlated with histological grade,tumor staging by the TNM system,lymph node metastasis,and vascular invasion(P<0.05).Kaplan-Meier survival analysis revealed that the 3-year overall survival rate of the miR-27a-3p low-expression group was 71.60%(48/67),which was lower than the 91.50%(54/59)of the miR-27a-3p high-expression group(log-rank x2=8.211,P=0.004).The 3-year overall survival rate of the YAP1 high-expression group was 73.80%(45/61),lower than that of the YAP1 low-expression group(87.70%,57/65)(log-rank x2=4.429,P=0.035).Multivariate regression analysis indicated that lymph node metastasis(hazard ratio[HR]=1.409;95%CI,1.057-1.644;P=0.046),vascular invasion(HR=1.541;95%CI,1.076-1.869;P=0.045),low miR-27a-3p mRNA expression(HR=0.593;95%CI,0.388-0.925;P=0.018),and high YAP1 mRNA expression(HR=0.628;95%CI,0.405-0.912;P=0.022)were relevant factors affecting the 3-year overall survival of patients with breast cancer.Conclusion A significant downregulation of miR-27a-3p mRNA and upregulation of YAP1 mRNA are observed in breast tumor tissues.The low expression of miR-27a-3p mRNA and the high expression of YAP1 mRNA are associated with adverse clinicopathological features and poor survival prognosis,and are risk factors affecting the 3-year overall survival of patients with breast cancer.They show promise as new potential therapeutic targets for breast cancer.
2.Influencing factors of aspiration in neurological critically ill patients:a Meta-analysis
Yang ZHANG ; Haiqing DIAO ; Mengyue LI ; Ting TIAN ; Xiaoguang LIU ; Qiang MA ; Guangyu LU ; Hailong YU ; Yuping LI
Journal of Clinical Medicine in Practice 2025;29(1):118-124
Objective To evaluate the influencing factors of aspiration in neurological critically ill patients by Meta-analysis.Methods PubMed,Embase,Web of Science,CNKI,and Wanfang Data were searched from inception to 1 October,2023,to obtain relevant studies on influencing fac-tors of aspiration in neurological critically ill patients.The literature screening,data extraction and quality evaluation were completed by two researchers.RevMan 5.4 and Stata 13.0 software were ap-plied for pooled Meta-analysisand assessed publication bias,respectively.Results A total of 8 arti-cles,including 1,315 neurocritical care patients,were included in this study.Nine influencing factors related to aspiration were extracted for Meta-analysis.The Meta-analysis results showed that the three influencing factors that caused aspiration in neurocritical care patients were stroke history(OR=5.03,95%CI,2.71 to 9.32,P<0.000 01),National Institutes of Health Stroke Scale(NIHSS)score>10(OR=3.35,95%CI,1.75 to 6.42,P=0.000 3),and gastric residual volume>150mL(OR=7.13,95%CI,2.55 to 9.96,P=0.001).Conclusion This study provides a scientific basis for clinical healthcare professionals to early identify high-risk patients for aspiration,take targeted inter-vention measures,and prevent the occurrence of aspiration.
3.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
4.Application of adaptive aperture in proton radiotherapy for brain tumors
Weiqing WU ; Xianglin YUAN ; Guangyuan HU ; Renchao ZHENG ; Qianxia LI ; Fei LIU ; Xiaoguang LU
Chinese Journal of Radiological Medicine and Protection 2024;44(1):24-28
Objective:To evaluate the clinical application value of the adaptive aperture by comparing intensity-modulated proton radiotherapy(IMPT) plans using and not using the aperture for brain tumors.Methods:A total of twenty patients treated with postoperative radiotherapy for brain tumors were enrolled in this study. IMPT plans were developed for each patient using and not using the adaptive aperture under the same optimization conditions. The target conformal index (CI) value, target homogeneity index (HI) value, and the dose to normal tissues of the two sets of plans were compared.Results:The IMPT plans designed using the adaptive aperture significantly increased the mean CI value from 0.58 to 0.66, while decreasing the mean 50% prescription dose volume from 797.70 cm 3 to 638.15 cm 3. These plans also reduced the irradiation doses to the cochlea, brainstem, optic chiasm, optic nerve, and lens ( t = 2.06, 3.02, 2.11, 2.58, 2.67, P < 0.05). Additionally, there was no significant difference in the HI value of the target volumes and the machine jumps (MU) between the two sets of plans ( P > 0.05). Conclusions:The adaptive aperture can significantly reduce the irradiation dose to normal tissues outside the target volumes, positively impacting the protection of organs at risk (OARs) around the target values. This demonstrates its great potential for clinical application.
5.Evaluation of analgesic effect of nalbuphine in patients with non-mechanical ventilation in intensive care unit: a multi-center randomized controlled trail
Yi ZHOU ; Shaohua LIU ; Song QIN ; Guoxiu ZHANG ; Yibin LU ; Xiaoguang DUAN ; Haixu WANG ; Ruifang ZHANG ; Shuguang ZHANG ; Yonggang LUO ; Yu FANG ; Xiaoyun FU ; Tao CHEN ; Lening REN ; Tongwen SUN
Chinese Journal of Emergency Medicine 2024;33(1):59-64
Objective:To analyze the efficacy and safety of nalbuphine for analgesia in patients with non-mechanical ventilation in intensive care unit (ICU).Methods:From December 2018 to August 2021, a multicenter randomized controlled clinical study was conducted to select non-mechanical ventilation patients with analgesic needs admitted to ICU of four hospitals in Henan Province and Guizhou Province. Patients were randomly assigned to nalbuphine group and fentanyl group. The nalbuphine group was given continuous infusion of nalbuphine [0.05~0.20 mg/(kg·h)], and the fentanyl group was given continuous infusion of fentanyl [0.5~2.0 μg/(kg·h)]. The analgesic target was critical-care pain observation tool (CPOT) score<2. The observation time was 48 hours. The primary endpoint was CPOT score, the secondary endpoints were Richmond agitation-sedation score (RASS), ICU length of stay, adverse events, and proportion of mechanical ventilation. The quantitative data of the two groups were compared by t test or Mann-Whitney U test. The enumeration data were compared by chi square test or Fisher exact probability method. The data at different time points between groups were compared by repeated measures analysis of variance. Results:A total of 210 patients were enrolled, including 105 patients in the nalbuphine group and 105 patients in the fentanyl group. There was no significant difference in baseline data between the two groups (all P>0.05). There was no significant difference in CPOT score between nalbuphine group and fentanyl group at each time point after medication ( P>0.05), the CPOT score of both groups at each time point after medication was significantly lower than that before medication, and the analgesic target could be achieved and maintained 2 hours after medication. There was no significant difference in RASS between the two groups at each time point after medication ( P>0.05), which was significantly lower than that before medication, and the target sedative effect was achieved 2 hours after medication. There was no significant difference in ICU length of stay between nalbuphine group and fentanyl group [5.0(4.0,7.5) d vs. 5.0(4.0,8.0) d, P=0.504]. The incidence of delirium, nausea and vomiting, abdominal distension, pruritus, vertigo and other adverse events in the nalbuphine group was lower than that in the fentanyl group (all P<0.05). There was no significant difference in the incidence of other adverse events such as deep sedation, hypotension and bradycardia between the two groups (all P>0.05). The incidence of respiratory depression in nalbuphine group was not significantly different from that in fentanyl group ( P>0.05), but the proportion of mechanical ventilation was significantly lower than that in the fentanyl group [1.9% (2/105) vs. 8.6%(9/105), P=0.030]. Conclusions:Nalbuphine could be used for analgesia in ICU patients with non-mechanical ventilation. The target analgesic effect could be achieved within 2 hours, and it had a certain sedative effect with a low incidence of adverse reactions.
6.The calibration of CT modeling for proton therapy treatment planning system
Renchao ZHENG ; Xiaoguang LU ; Weiqing WU ; Zu'an ZHENG ; Zhiping XIAO ; Junchao LI ; Xianglin YUAN
Chinese Journal of Radiation Oncology 2024;33(10):935-941
Objective:To verify and calibrate the CT modeling curves of three CT devices in RayStation proton treatment planning system (TPS).Methods:CT-mass density (CT-MD) curves were established by CT Hounsfield units of different tissue substitute materials obtained by scanning the model with CT equipment. CT-stopping power (CT-SP) curves were established by calculation based on the chemical composition of various human tissues. The equivalent water thickness of tissue substitute modules was calculated with different CT modeling curves in TPS. The actual equivalent water thickness of various modules was measured by a Bragg peak detector, and compared with the calculated values of TPS to verify the accuracy of different CT models.Results:The differences of CT modeling curves were significantly different under different tube voltage scanning protocols. Compared with CT-MD curves, CT-SP curves based on the stoichiometric calibration were more suitable for proton dose calculation. However, the values of stopping power corresponding to high CT values still needed to be optimized, and the calculation error after calibration was less than 3%.Conclusion:The method of verifying and calibrating CT unit curves of proton TPS is described, proving that the CT-SP curves after stoichiometric calculation are more suitable for proton dose calculation.
7.Analysis of beam characteristics of the first Mevion pencil beam scanning proton therapy system in China
Weiqing WU ; Xiaoguang LU ; Renchao ZHENG ; Zhiyi PENG ; Fei LIU ; Guangyuan HU ; Xianglin YUAN
Chinese Journal of Medical Physics 2024;41(3):282-288
Objective To present and discuss beam characteristics of the first Mevion S250i gantry-mounted accelerator pencil beam scanning proton therapy system in China.Methods The output dose was measured using a parallel-plate ionization chamber.The integrated depth dose was measured with a large-radius Bragg peak ionization chamber,covering 19 energy levels ranging from 227 MeV to 28 MeV,to analyze the proton beam characteristics.The spots in the air were measured with Phoenix flat panel detector on the beam central axis,and the precision of the delivery position was verified by measuring the multi-spot beam map.The interleaf leakage and penumbra reduction of adaptive aperture were measured to characterize its performance.Results The proton system was calibrated for a maximum energy of 227 MeV,with a(10×10)cm2uniform field delivering 1 Gy dose at a depth of 5 cm underwater.The system effectively modulated the proton beam range to the patient's surface,maintaining a constant 80%-80%Bragg peak width of 8.6 mm at all energy levels.The spot size of the highest energy beam at the isocenter was about 4 mm in the air,and the spot delivery position error was less than 1 mm.The interleaf leakage rate of the adaptive aperture for the highest energy beam was below 1.5%,and the penumbra was significantly reduced.Conclusion Mevion S250i proton therapy system demonstrates unique design and beam characteristics,which is reflected in the Bragg peak shape,spot size variation with energy,and penumbra sharpening of adaptive aperture;and these differences should be considered in treatment planning system modeling and planning for precision treatment.
8.Application of rapid daily quality assurance for pencil beam scanning proton therapy system
Renchao ZHENG ; Xiaoguang LU ; Weiqing WU ; Zhiping XIAO ; Fei LIU ; Guangyuan HU ; Xianglin YUAN
Chinese Journal of Medical Physics 2024;41(10):1206-1210
Objective To analyze the daily quality assurance(QA)measurement results of IBA Sphinx Compact device on the Mevion compact pencil beam scanning proton therapy system for evaluating its clinical application value in proton therapy.Methods The daily QA measurement of Mevion S250i proton therapy system was carried out with Sphinx Compact device for 30 consecutive days,and the measurement results were analyzed.Results The average deviation between the positioning laser and the image center was(0.42±0.27)mm in 30 days.All of the proximal and distal depth errors of the high-and low-energy pencil beams were within 0.50 mm.The position deviation of all the spots measured did not exceed 1.00 mm,and the size deviation was less than 7.5%.The deviation between the image center and the beam center was not more than 0.75 mm.The relative deviation of the flatness of the rectangular field was about 0.5%.The deviation of the output dose of the square field was within 1.0%.Conclusion The proton system daily QA measurement items recommended by AAPM TG-224 report can be accurately and rapidly measured with Sphinx Compact device.The device is a practical and efficient daily QA tool with high practical value in clinic.
9.Analysis on the clinical efficacy and influencing factors of Vbeam 595 nm pulsed dye laser in the treatment of superficial IHs
Si WANG ; Chunjing LIU ; Xiaoguang XING ; Lu CHANG
China Medical Equipment 2024;21(8):96-100
Objective:To retrospectively study the curative effect of Vbeam 595nm pulsed dye laser(PDL)in treating the mid-term infantile hemangiomas(IHs),and analyze and explore the possible influencing factors of that.Methods:A total of 219 IHs patients who underwent PDL treatment in Tangshan Maternal and Child Health Care Hospital from January 2020 to December 2022 were selected,and they received follow-up at least 6 months.The relationship between the treatment effect and the month age,location,thickness of hemangioma and the number of treatments was analyzed.Results:The median month age of the 219 pediatric children was 7 months,and the average month age of them was(4-10)months,and there was a total of 219 lesions.There were no statistically significant differences in the general data such as month age and the characteristics of lesion between different genders(P>0.05).The overall effective rate of treatment was 92.7%,and the median number of treatments was 3 times,and the average number of treatments was(2-4)times.There were no statistically significant differences in the comparisons of gender,the number of treatments and the treatment outcome(P>0.05).The curative effects of 6 pediatric children were poor,whose month age was 13(8,19)months.The curative effects of 10 pediatric children were general,whose month age was 13(8,14)months.The curative effects of 31 pediatric children were favorable,whose month age was 8(4,10)months.The curative effects of 172 pediatric children were excellent,whose month age was 6(4,9)months.The difference of month age of pediatric children among different curative effect was significant(Z=24.863,P<0.001),and the pediatric children with better curative effect had smaller month age.The treatment outcome of pediatric children with hemangioma was correlated with the thickness of lesion,the area size of lesion and the number of treatment(r=-0.32,-0.46,-0.46,P<0.05),respectively.The effective treatment mainly focused on the treatments of the 2nd-4th times.The adverse reaction caused by treatment was skin erythema,and the rate of the total residual after six months of the complication was 5.48%.Conclusion:The treatment of 595nm PDL combined with dynamic cooling device(DCD)can provide a safe and effective treatment for IHs.Early intervention for IHs can improve the curative effect,and reduce the course of treatment,and further reduce the possibility of corresponding complications.
10.Acceptance test of beam performance and mechanical precision of the first Mevion type S250i proton therapy system in China
Weiqing WU ; Xiaoguang LU ; Renchao ZHENG ; Fei LIU ; Guangyuan HU ; Xianglin YUAN
China Medical Equipment 2024;21(9):13-17
Objective:To discuss the acceptance test of beam performance and mechanical precision of the first Mevion type S250i proton therapy system in China,and verify the stability and reliability of that in clinical treatment.Methods:According to the requirements of acceptance report of manufacturer,the output and range of machine unit(MU),the accuracy and stability of size and position of beam spot,the penumbra and position accuracy of adaptive aperture(AA)of Mevion type S250i proton therapy system,as well as the tests of mechanical properties and functions of the requirement of clinical use,were checked and tested for acceptance.Results:The maximum deviation of MU output was 1.3%,and the maximum deviation of the range was 0.037 g/cm2,and the maximum distal fall-off was 0.465 cm,and the minimum range of energy modulation was 0.21 g/cm2.The maximum deviations of the size of beam spot and the maximum deviation of the position were respectively 0.07 cm and 0.05 cm.The maximum AA penumbra was 0.007 cm,and the AA position accuracy was less than 0.1 cm.Conclusion:The acceptance test of the Mevion type S250i proton therapy system indicates that the parameters of the beam performance and mechanical precision can meet the requirements of the acceptance contract and AAPM-TG224 report of manufacturer,which has verified the machine has better favorable stability and reliability.

Result Analysis
Print
Save
E-mail