1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Liang-Ge-San Decoction Ameliorates Acute Respiratory Distress Syndrome via Suppressing p38MAPK-NF-κ B Signaling Pathway.
Quan LI ; Juan CHEN ; Meng-Meng WANG ; Li-Ping CAO ; Wei ZHANG ; Zhi-Zhou YANG ; Yi REN ; Jing FENG ; Xiao-Qin HAN ; Shi-Nan NIE ; Zhao-Rui SUN
Chinese journal of integrative medicine 2025;31(7):613-623
OBJECTIVE:
To explore the potential effects and mechanisms of Liang-Ge-San (LGS) for the treatment of acute respiratory distress syndrome (ARDS) through network pharmacology analysis and to verify LGS activity through biological experiments.
METHODS:
The key ingredients of LGS and related targets were obtained from the Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform. ARDS-related targets were selected from GeneCards and DisGeNET databases. Gene Ontology and Kyoto Encyclopedia of Genes and Genomes enrichment analyses were performed using the Metascape Database. Molecular docking analysis was used to confirm the binding affinity of the core compounds with key therapeutic targets. Finally, the effects of LGS on key signaling pathways and biological processes were determined by in vitro and in vivo experiments.
RESULTS:
A total of LGS-related targets and 496 ARDS-related targets were obtained from the databases. Network pharmacological analysis suggested that LGS could treat ARDS based on the following information: LGS ingredients luteolin, wogonin, and baicalein may be potential candidate agents. Mitogen-activated protein kinase 14 (MAPK14), recombinant V-Rel reticuloendotheliosis viral oncogene homolog A (RELA), and tumor necrosis factor alpha (TNF-α) may be potential therapeutic targets. Reactive oxygen species metabolic process and the apoptotic signaling pathway were the main biological processes. The p38MAPK/NF-κ B signaling pathway might be the key signaling pathway activated by LGS against ARDS. Moreover, molecular docking demonstrated that luteolin, wogonin, and baicalein had a good binding affinity with MAPK14, RELA, and TNF α. In vitro experiments, LGS inhibited the expression and entry of p38 and p65 into the nucleation in human bronchial epithelial cells (HBE) cells induced by LPS, inhibited the inflammatory response and oxidative stress response, and inhibited HBE cell apoptosis (P<0.05 or P<0.01). In vivo experiments, LGS improved lung injury caused by ligation and puncture, reduced inflammatory responses, and inhibited the activation of p38MAPK and p65 (P<0.05 or P<0.01).
CONCLUSION
LGS could reduce reactive oxygen species and inflammatory cytokine production by inhibiting p38MAPK/NF-κ B signaling pathway, thus reducing apoptosis and attenuating ARDS.
Drugs, Chinese Herbal/pharmacology*
;
Respiratory Distress Syndrome/enzymology*
;
p38 Mitogen-Activated Protein Kinases/metabolism*
;
NF-kappa B/metabolism*
;
Animals
;
Signal Transduction/drug effects*
;
Molecular Docking Simulation
;
Humans
;
Male
;
Network Pharmacology
;
Apoptosis/drug effects*
;
Mice
5.Integrating traditional Chinese medicine constitutions into insomnia management: Findings from a cross-sectional study.
Yan HAN ; Yu WANG ; Mo-Yi SHI ; Yu LIU ; Xiao-Dong CHENG ; Yang ZHOU
Journal of Integrative Medicine 2025;23(4):382-389
OBJECTIVE:
The concept of constitution in traditional Chinese medicine (TCM) has been increasingly recognized as a crucial factor in both the prevention and treatment of insomnia. However, rigorous statistical evidence on the correlation between TCM constitutions-particularly mixed constitutions-and insomnia disorder remains limited. This study aimed to investigate the association between specific TCM constitutions and insomnia disorder.
METHODS:
A cross-sectional study was conducted at the Department of Preventive Medicine, Yueyang Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai, from November 2022 to December 2023. TCM constitutions were assessed using the Constitution in Chinese Medicine Questionnaire. Insomnia disorder was diagnosed by experienced internal medicine physicians according to the criteria of the International Classification of Sleep Disorders, Third Edition. A total of 1065 eligible participants (242 with insomnia disorder and 823 controls) were included in the final analysis.
RESULTS:
Among the participants, 862 (80.94%) exhibited biased constitutions, with 75.30% of these having mixed constitutions. Logistic regression analysis revealed a negative association between the gentleness constitution and insomnia disorder, whereas qi-deficiency, yang-deficiency, phlegm-dampness and qi-depression constitutions were positively associated with insomnia disorder. These associations remained significant after adjusting for potential confounders and were further validated through sensitivity analysis using propensity score matching.
CONCLUSION
Significant associations between TCM constitutions and insomnia disorder were demonstrated. Future research should further investigate these relationships and explore the underlying mechanisms through rigorous longitudinal and interventional studies to improve understanding and clinical applications. Please cite this article as: Han Y, Wang Y, Shi MY, Liu Y, Cheng XD, Zhou Y. Integrating traditional Chinese medicine constitutions into insomnia management: Findings from a cross-sectional study. J Integr Med. 2025; 23(4): 382-389.
Humans
;
Sleep Initiation and Maintenance Disorders/therapy*
;
Cross-Sectional Studies
;
Medicine, Chinese Traditional/methods*
;
Male
;
Female
;
Middle Aged
;
Adult
;
Aged
;
Surveys and Questionnaires
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Relationship between decline of exercise ability and mitochondrial damage in skeletal muscle of mice with high-altitude de-acclimatization
Yehui GAO ; Huiying SHANG ; Hongbo CHENG ; Weiye HAN ; Wei ZHOU ; Zhiping YU ; Xianglin TANG ; Chengrong XIAO ; Xian LIU ; Yue GAO
Chinese Journal of Pathophysiology 2025;41(7):1375-1382
AIM:This study aims to investigate the mechanisms underlying skeletal muscle mitochondrial damage associated with decline in exercise function during high-altitude de-adaptation,using a mouse model.METHODS:Twen-ty-four healthy male C57BL/6J mice were randomly assigned to two groups:a high-altitude de-adaptation group and a plain control group.The model group was exposed to a low-pressure,low-oxygen chamber simulating an altitude of 7 000 meters for two weeks,followed by eight days of rearing in a plain environment.The control group was maintained in a plain envi-ronment for the same duration.Grip strength and pole-climbing tests were conducted on the 1st,3rd,and 5th days post-re-turn to assess muscle strength and motor coordination.Treadmill exercises were performed on the 4th and 8th days to eval-uate exercise endurance.After the treadmill exercise on the 8th day,serum,liver,and skeletal muscle tissues were col-lected.Levels of lactic acid(LA),glucose(GLU),creatine kinase(CK),lactate dehydrogenase(LDH),alanine trans-aminase(ALT),and aspartate aminotransferase(AST)in serum,as well as glycogen levels in the liver and muscle,were analyzed.Additionally,the expression of proteins related to mitochondrial biogenesis,fission,fusion,and oxidative phos-phorylation in muscle tissues was assessed using Western blot.RESULTS:(1)The model group exhibited significant re-ductions in grip strength,increased pole-climbing T-turn and total times,and decreased total time and distance in the ex-haustion running test.(2)Serum levels of LA,CK,LDH,ALT,and AST were elevated,while GLU levels decreased,and glycogen levels in both the liver and muscle were reduced in the model group following the treadmill exercise.(3)Ab-normal indicators in the model group did not return to normal by the end of the de-adaptation period.(4)Western blot analysis revealed decreased expression of mitochondrial oxidative phosphorylation proteins(ATP6V1A and Mt-CO2)and mitochondrial biogenesis proteins(PGC-1α and FGF21),increased levels of mitochondrial fusion proteins(OPA1 and MFN1),and no significant changes in fission protein expression(FIS1 and DRP1)in muscle tissue from the model group.CONCLUSION:Exercise capacity in mice during the high-altitude de-adaptation period significantly declined,particu-larly in terms of muscle strength,motor coordination,and endurance.This decline is closely associated with abnormal pro-tein expression related to skeletal muscle mitochondrial energy metabolism and production.
9.Filter's retraction hook capture technique of pull-assisted method for endovascular retrieval of conical inferior vena cava filter whose hook attached to the wall
Xuan TIAN ; Jianlong LIU ; Han ZHENG ; Jinyong LI ; Xiao LIU ; Mi ZHOU ; Wei JIA ; Peng JIANG ; Zhiyuan CHENG ; Yunxin ZHANG ; Chengjia QU ; Run HUA ; Chenyang TIAN
Chinese Journal of General Surgery 2025;40(11):856-862
Objective:To investigate the clinical application value of a novel filter's retraction hook capture technique of pull-assisted method for the endovascular retrieval of conical inferior vena cava (IVC) filters whose hook attached to the wall.Methods:From January 2020 to December 2024, patients with conical filters whose hook attached to the wall admitted at Beijing Jishuitan Hospital were enrolled consecutively.Results:A total of 46 patients underwent filter retrieval using filter's retraction hook capture technique of pull-assisted method. Among these patients, 39 cases (84.8%) were successful in filter retrieval, with the penetration distance of cranial anchor vertex of 3.3(2.5, 4.4) mm, and 13 (33.3%) filters were deformed. The other 7 cases were unsuccessful, with a penetration distance of cranial anchor vertex of 5.0 (4.3, 5.0) mm, and 6 (85.7%) filters were deformed. There was a statistically significant difference between the two groups ( P<0.05). One case (2.2%) had IVC injury, one case (2.2%) experienced filter fracture, and no symptomatic pulmonary embolism occurred. Logistic regression analysis showed that filter deformation was an independent dangerous factor for filter's retraction. Conclusions:Filter's retraction hook capture technique of pull-assisted method is effective in removing conical filters whose hook attached to the wall, with no symptomatic PE occurring. This method can be considered as a new adjuvant technique for filter retrieval.
10.Flow Field Characteristics of Aortic Valve with Eccentric Lower Valve Placement:A PIV Experimental Study
Enhui HAN ; Qianwen HOU ; Yang XIAO ; Yana MENG ; Haiyang WEI ; Yu JIANG ; Jianjun HU ; Jianye ZHOU
Journal of Medical Biomechanics 2025;40(1):25-33
Objective To investigate the impact of eccentric placement for various types of artificial aortic valves on downstream flow dynamics.Methods A physiological pulsatile circulation simulation system was employed and particle image velocimetry(PIV)was utilized to analyze the downstream flow field variations for bioprosthetic and mechanical valves under two placement conditions:centralized placement(0 mm)and eccentric placement(1 mm).Hemodynamic parameters such as velocity,vorticity,and viscous shear stress were assessed to evaluate the flow field characteristics.Results By analyzing the flow field variations at four characteristic time points,namely,early systole,acceleration phase,peak systole,and deceleration phase,a significant difference in flow field distribution between bioprosthetic and mechanical valves was observed.The bioprosthetic valve exhibited a centrally symmetric jet with a higher flow velocity,whereas the mechanical valve displayed a three-jet structure with a lower central flow velocity.Under eccentric placement,the blood flow in the aortic sinus region was sluggish,with a reduction in average velocity,hindering the formation and maintenance of vortices.During the peak systolic phase,the maximum viscous shear stresses in the sinus region for the bioprosthetic and mechanical valves were 0.45 and 0.67 Pa,respectively,approaching the threshold for endothelial cell damage.Conclusions Eccentric placement of both mechanical and bioprosthetic valves resulted in reduced sinus blood flow velocity and diminished viscous shear stress,creating favorable conditions for thrombus formation.In clinical practice,careful attention should be given to the placement of valve replacement to prevent eccentric placement.

Result Analysis
Print
Save
E-mail