1.Laboratorydiagnosis and perinatal blood management of HDFN in a Jr(a-) pregnant woman
Pan XIAO ; Ke SONG ; Wei YANG ; Lingling LI ; Yi LIU ; Chunya MA ; Yang YU
Chinese Journal of Blood Transfusion 2026;39(2):248-255
Objective: To report the antibody identification, blood management during pregnancy and the monitoring process of fetal hemolytic disease of fetus and newborn (HDFN) in a pregnant woman with a history of blood transfusion and pregnancy who developed anti-Jr
. Methods: Saline tube technique and anti-human globulin technique were used for maternal blood typing, unexpected antibody screening and identification, as well as for determining antibody titer and IgG subclasses. PCR-SSP was employed for genotyping of 18 blood group systems. Next-generation sequencing (NGS) was utilized for gene sequencing of 38 blood group systems. Sanger sequencing was applied to verify rare blood group mutations detected by NGS and to investigate the corresponding rare blood group genes in family members. Blood preparation was achieved through anemia management in prenatal clinics and autologous blood collection during pregnancy. The newborn underwent the three primary tests for HDFN and plasma IgG subclass testing. Results: The pregnant woman's blood type was B, RhD positive, with a positive unexpected antibody screen, and the antibody identification pattern was consistent with a high-frequency antigen antibody. Gene sequencing revealed a homozygous ABCG2 c.376C>T mutation in the woman, resulting in the Jr(a-) phenotype, and anti-Jr
antibody was present in her plasma. No compatible Jr(a-) blood was found among family members. The maternal anti-Jr
IgG titer remained stable at 256 during pregnancy, with no detectable IgG1 or IgG3 subclasses against the Jr
antigen. A total of 800 mL of autologous blood was collected in two stages during pregnancy. The newborn was B, RhD positive, Jr(a+), with a positive unexpected antibody screen (anti-Jr
). IgG subclass typing detected no IgG1 or IgG3. The direct antiglobulin test was positive, while the acid elution test was negative. Conclusion: The combination of serology and blood group genetic analysis provides a diagnostic basis for identifying antibodies to high-frequency antigens. Managing perinatal anemia and implementing staged autologous blood storage can secure blood supply for the perioperative period. IgG antibody subclass typing offers a reference for clinical assessment and prevention of HDFN.
2.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
3.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
4.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
5.The expression and mechanistic study of Y‑box binding protein‑1 in oral squamous cell carcinoma
Yi ZHANG ; Xiao YU ; Wei SHAO ; Xin CHEN
Acta Universitatis Medicinalis Anhui 2026;61(3):524-532
ObjectiveTo analyze the expression level and clinical significance of Y‑box binding protein‑1(YB1) in tissues and cells of oral squamous cell carcinoma (OSCC). MethodsBioinformatics analysis, immunohistochemistry, Western blot and qRT-PCR were used to detect the expression of YB1 in OSCC tissues, and the prognosis and survival analysis were performed. The effects of YB1 on the proliferation, migration and invasion of OSCC cells were evaluated by CCK-8, scratch assay and Transwell assay, and the expression changes of phosphoinositide 3-kinase/protein kinase B (PI3K/AKT) signaling pathway and epithelial-mesenchymal transition (EMT) related markers after YB1 knockdown were detected by Western blot. ResultsBioinformation analysis showed that the expression level of YB1 in OSCC samples was higher than that in normal samples (P0.001), and its expression was correlated with gender (P=0.022) and tumor differentiation degree (P0.001). Kaplan-Meier plotter survival analysis showed that the survival rate of YB1 was low (Log-rank P=0.012). Immunohistochemistry, Western blot and qRT-PCR experiments verified that the expression level of YB1 in OSCC tissues was higher than that of normal tissues. The results of cell experiments showed that knockdown of YB1 inhibited the malignant biological behaviors such as proliferation, migration and invasion of OSCC cells. Western blot results showed that the knockdown of YB1 could reduce the protein expression levels of p-PI3K and p-AKT, and inhibit EMT. ConclusionYB1 is highly expressed in tissues and cells in OSCC, and reveals the important role of the YB1/PI3K/AKT axis in the process of EMT of OSCC, which is expected to become a new tumor marker for early diagnosis and treatment and prognosis evaluation of OSCC.
6.Rapid Identification of Different Parts of Nardostachys jatamansi Based on HS-SPME-GC-MS and Ultra-fast Gas Phase Electronic Nose
Tao WANG ; Xiaoqin ZHAO ; Yang WEN ; Momeimei QU ; Min LI ; Jing WEI ; Xiaoming BAO ; Ying LI ; Yuan LIU ; Xiao LUO ; Wenbing LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):182-191
ObjectiveTo establish a model that can quickly identify the aroma components in different parts of Nardostachys jatamansi, so as to provide a quality control basis for the market circulation and clinical use of N. jatamansi. MethodsHeadspace solid-phase microextraction-gas chromatography-mass spectrometry(HS-SPME-GC-MS) combined with Smart aroma database and National Institute of Standards and Technology(NIST) database were used to characterize the aroma components in different parts of N. jatamansi, and the aroma components were quantified according to relative response factor(RRF) and three internal standards, and the markers of aroma differences in different parts of N. jatamansi were identified by orthogonal partial least squares-discriminant analysis(OPLS-DA) and cluster thermal analysis based on variable importance in the projection(VIP) value >1 and P<0.01. The odor data of different parts of N. jatamansi were collected by Heracles Ⅱ Neo ultra-fast gas phase electronic nose, and the correlation between compound types of aroma components collected by the ultra-fast gas phase electronic nose and the detection results of HS-SPME-GC-MS was investigated by drawing odor fingerprints and odor response radargrams. Chromatographic peak information with distinguishing ability≥0.700 and peak area≥200 was selected as sensor data, and the rapid identification model of different parts of N. jatamansi was established by principal component analysis(PCA), discriminant factor alysis(DFA), soft independent modeling of class analogies(SIMCA) and statistical quality control analysis(SQCA). ResultsThe HS-SPME-GC-MS results showed that there were 28 common components in the underground and aboveground parts of N. jatamansi, of which 22 could be quantified and 12 significantly different components were screened out. Among these 12 components, the contents of five components(ethyl isovalerate, 2-pentylfuran, benzyl alcohol, nonanal and glacial acetic acid,) in the aboveground part of N. jatamansi were significantly higher than those in the underground part(P<0.01), the contents of β-ionone, patchouli alcohol, α-caryophyllene, linalyl butyrate, valencene, 1,8-cineole and p-cymene in the underground part of N. jatamansi were significantly higher than those in the aboveground part(P<0.01). Heracles Ⅱ Neo electronic nose results showed that the PCA discrimination index of the underground and aboveground parts of N. jatamansi was 82, and the contribution rates of the principal component factors were 99.94% and 99.89% when 2 and 3 principal components were extracted, respectively. The contribution rate of the discriminant factor 1 of the DFA model constructed on the basis of PCA was 100%, the validation score of the SIMCA model for discrimination of the two parts was 99, and SQCA could clearly distinguish different parts of N. jatamansi. ConclusionHS-SPME-GC-MS can clarify the differential markers of underground and aboveground parts of N. jatamansi. The four analytical models provided by Heracles Ⅱ Neo electronic nose(PCA, DFA, SIMCA and SQCA) can realize the rapid identification of different parts of N. jatamansi. Combining the two results, it is speculated that terpenes and carboxylic acids may be the main factors contributing to the difference in aroma between the underground and aboveground parts of N. jatamansi.
7.Development of A High-performance Rectangular Ion Trap for Multi-reflection Time-of-Flight Mass Spectrometer
Xiao-Xia CHEN ; Yi REN ; Qi HUANG ; Da-Jun XIANG ; Chang-Wei LI ; Yi HONG ; Lei LI ; Zheng-Xu HUANG ; Mei LI ; Jing-Wei XU ; Zhen ZHOU
Chinese Journal of Analytical Chemistry 2025;53(1):38-46
As a new generation of time-of-flight mass spectrometry,multiple-reflection time-of-flight mass spectrometry(MR-TOF-MS)has been increasingly applied in the fields such as nuclear physics,chemistry,and biology due to its ultra-high resolution and rapid analysis capabilities.However,the analytical performance of MR-TOF-MS largely depends on the ion bunch state entering the mass analyzer.In this study,a rectangular ion trap(RIT)was developed,designed and processed using printed circuit board technology,as an ion accumulating and focusing device for MR-TOF mass analyzer.Compared to traditional ion traps composed of two sets of planar electrodes,this RIT had higher voltage utilization efficiency,resulting in more efficient ion collection and focusing.The ions were cooled to a sufficiently small bunch for precise mass measurement with MR-TOF-MS mass spectrometry in only 1 ms of cooling time in the RIT,then orthogonally ejected to the MR-TOF mass spectrometer for mass analysis.Experimental results indicated that the working cycle,ion flux,and ion focusing state of the RIT fully met the requirements of the MR-TOF mass analyzer.When coupled with the MR-TOF mass analyzer,the RIT enabled MR-TOF-MS to achieve a mass resolution of 1.5×105.
8.Simultaneous Determination of Ten Kinds of Neonicotinoid Residues in Water for Aquaculture by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
Li-Sha MA ; Yi YIN ; Lin-Ting WEI ; Qi SHAN ; Xiao-Xin DAI ; Shu-Gui LIU
Chinese Journal of Analytical Chemistry 2025;53(8):1352-1361,中插96-中插99
A solid-phase extraction-ultra-performance liquid chromatography-tandem mass spectrometry(SPE-UPLC-MS/MS)method was established for simultaneous determination of 10 kinds of neonicotinoid pesticide residues in aquaculture water.Based on the chemical properties of neonicotinoid pesticides and the matrix characteristics of aquaculture water,suitable temporary storage methods for water samples and appropriate solid-phase extraction columns were selected,and the extraction conditions(including elution solvents and sample loading volumes)were optimized.The method employed acetonitrile and 5 mmol/L ammonium acetate solution(containing 0.1%formic acid)as the mobile phase and an Oasis HLB solid-phase extraction column combined with PSA as a dispersive sorbent for sample purification.The method exhibited good linearity in detection of neonicotinoid in concentration range of 0.2-50 ng/mL(R2>0.99797),with a detection limit of 0.5 ng/L and a quantification limit of 1 ng/L,which were significantly lower than the maximum acceptable method detection limits(9-500 ng/L)for neonicotinoid insecticides in water published by the European Commission.In pond water,rice-fish water,and seawater,the average recoveries of the 10 target analytes were 74.6%-114.1%,with relative standard deviations ranging from 0.3%to 9.6%.Using this method,actual sample tests were conducted on the Pearl River water,Zhaoqing pond water,and Qingyuan rice-fish aquaculture water.The total concentration of five neonicotinoid pesticides in the Pearl River water ranged from 154.8 to 246.6 ng/L,the total concentration of four neonicotinoid pesticides in the Zhaoqing pond water was 95.0-176.1 ng/L,and the total concentration of three neonicotinoid pesticides in the Qingyuan rice-fish aquaculture water was 2.3-11.7 ng/L.This method was simple in operation,highly sensitive,and had strong resistance to interference.It was suitable for detection of trace neonicotinoid pesticides in aquaculture water and could provide technical support for construction of a green aquaculture environment and resolution of international trade disputes.
9.Estimate the Age of Han Adult Based on the Pulp Chamber Volume and Pulp Dentinal Index of Right First Molars Using Oral and Maxillofacial CBCT
Yan-Jie DING ; Xiao ZHANG ; Wen-Li SHI ; Zi-Yi LI ; Wei WANG ; Shi-Lin ZHANG ; Gen-Jie YANG ; A-Ji GUO ; Bo JIN
Journal of Forensic Medicine 2025;41(1):59-65
Objective To explore the correlation between the actual age and the pulp chamber volume(PCV)and pulp dentinal index(PDI)of the right first molars based on cone beam computed tomog-raphy(CBCT)technology,and to construct an accurate and convenient model for age estimation.Methods CBCT image data of 1 857 Han adults(883 males and 974 females)from the Department of Stomatology,Affiliated Hospital of North Sichuan Medical College were collected.The data were di-vided into training and validation sets at a ratio of 8∶2.A total of 1 485 training samples were used to construct the age estimation model,and 372 samples were used to validate the accuracy of the model.The Mimics 21.0 software was used to measure the PCV and calculate the PDI of the right first molars.Their correlations with age and the differences between different sexes and tooth positions were analyzed.Results Both the PCV and the PDI of the first molars showed strong negative correla-tions with the actual age(r values ranged from 0.82 to 0.89).The differences in PCV and PDI be-tween different sexes and tooth positions were statistically significant(P<0.05).The age estimation model based on PDI was superior to that based on PCV.The model based on the PDI values of the two right first molars(y=73.72-44.15 x3-28.27 x4,where x3 and x4 are the PDI values of the right maxil-lary and mandibular first molars,respectively)was the best,with the R2 of 0.79 and the mean abso-lute error of 4.90 years.Conclusion Both PCV and PDI of the first molars are effective indicators for age estimation.The age estimation model based on the PDI is more convenient and accurate than that based on the PCV,providing a more effective method for age estimation in forensic practice.
10.Comparison of Three Drowning-related Plankton Testing Methods in Drowning Diagnosis
Xiao-Feng ZHANG ; Qin SU ; Xiao-Hui CHEN ; Wei-Bin WU ; Dong-Yun ZHENG ; Jian ZHAO ; Ling CHEN ; Qu-Yi XU ; Chao LIU
Journal of Forensic Medicine 2025;41(3):244-251
Objective To compare the application effects of plankton multiplex polymerase chain reac-tion-capillary electrophoresis(PCR-CE),SYBR Green Ⅰ real-time quantitative PCR(qPCR)and microwave digestion-vacuum filtration-automated scanning electron microscopy(MD-VF-Auto SEM)in the diagnosis of drowning.Methods Lung,liver and kidney tissues from 212 drowned corpses and 30 non-drowned corpses were examined respectively by the three drowning-related plankton testing methods,and the detection rates of plankton in each tissue by three methods were compared.Results In drowned corpses,the total detection rates of PCR-CE,qPCR,and MD-VF-Auto SEM were 93.9%,96.2%,and 95.3%,respectively,with no statistically significant difference(P>0.05).The detection rate of lung tissue by MD-VF-Auto SEM(100%)was higher than those of PCR-CE and qPCR(P<0.05),and there was no significant difference in the detection rates of the three methods in liver or kidney tissues(P>0.05).In non-drowning corpses,a small number of diatoms(less than 10 cells/10 g)were detected by MD-VF-Auto SEM method,only in liver and kidney tissues,while the other two methods yielded negative results for all tissues.Conclusion All three methods have good efficacy in the examination of drowned corpses.The MD-VF-Auto SEM method directly observes diatom morpho-logical characteristics through scanning electron microscopy,and the qualitative and quantitative analy-ses are intuitive and accurate.It has great advantages in the examination of difficult degradation samples.The PCR-CE method and qPCR method have a low sample demand(0.5 g),are easy to operate and have short detection time(4-7 h).They are easy to be applied in the grassroots depart-ments and are suitable for the rapid determination of drowned corpses in routin cases.The combina-tion of the two DNA methods with the MD-VF-Auto SEM method can increase the detection rate of plankton,ensuring the reliability of examination results.This combined use is of significant importance in the application of drowning diagnosis.

Result Analysis
Print
Save
E-mail