1.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
2.Cross-sectional survey of healthcare-associated infection in 5 736 medical institutions across China in 2024
Cui ZENG ; Wuqiang GAO ; Fu QIAO ; Hui ZHAO ; Xu FANG ; Linping LI ; Xiuwen CHEN ; Jiansen CHEN ; Dan LI ; Yuan ZHOU ; Lingli YU ; Qinglan MENG ; Xia MOU ; Lijuan XIONG ; Weiguang LI ; Ding LIU ; Jiaqing XIAO ; Limei OU ; Baozhen LI ; Jun YIN ; Haojun ZHANG ; Qiang FU ; Qun LU ; Biao WU ; Ya-wei XING ; Shumei SUN ; Shuncai WANG ; Longmin DU ; Jingping ZHANG ; Wen-ying HE ; Gui CHENG ; Nan REN ; Xun HUANG ; Anhua WU
Chinese Journal of Infection Control 2025;24(11):1572-1583
Objective To understand the current situation of healthcare-associated infection(HAI)in China,pro-vide data support and decision-making basis for formulating scientific and effective strategies for HAI prevention and control.Methods A nationwide cross-sectional survey on HAI was conducted among various types and levels of medical institutions in China according to a unified protocol of bedside surveys and case investigations.Results In 2024,a total of 5 736 medical institutions and 2 751 765 patients were surveyed.Among them,34 889 HAI cases were identified,with a prevalence rate of 1.27%.The number of HAI episodes was 38 032,and case prevalence rate was 1.38%.The prevalence rate of HAI in medical institutions in different regions of China ranged from 0.66%to 2.35%.Among medical institutions of different scales,those with a bed capacity of ≥900 had the high-est incidence of HAI,reaching 1.65%.The most common infection site was the lower respiratory tract(44.66%),followed by the urinary tract(12.94%),surgical site(9.32%),upper respiratory tract(7.02%),and bloodstream infection(5.78%).The top 3 departments with the highest HAI rates were the general intensive care unit(10.02%),department of neurosurgery(5.51%),and department(group)of hematology(5.34%).A total of 23 238 strains of HAI pathogens were detected,with 10 714 strains(46.10%)from lower respiratory tract speci-mens.The top 5 detected strains were Klebsiella pneumoniae(14.76%),Pseudomonas aeruginosa(13.33%),Escherichia coli(12.79%),Acinetobacter baumannii(9.23%),and Staphylococcus aureus(7.88%).231 944 pa-tients underwent class Ⅰ incision surgery were monitored,with 1 647 cases experienced surgical site infection,and the prevalence rate of surgical site infection was 0.71%.The number of patients who should undergo pathogen de-tection(patients receiving therapeutic and therapeutic combined prophylactic antimicrobial agents)was 715 179,while the actual number was 480 492,with a pathogen detection rate of 67.18%.425 225 patients received patho-genic detection before treatment,with a detection rate of 59.46%.Conclusion The overall HAI prevalence in Chi-na is lower,showing disparities among medical institutions of different regions and scales.Therefore,precise imple-mentation of measures is necessary for HAI prevention and control,with a focus on high-risk institutions and high-risk departments,key areas,and critical procedures.All levels of medical institutions should continuously reduce the incidence of HAI by strengthening monitoring,standardizing the use of antimicrobial agents,and reinforcing basic HAI prevention and control measures.
3.Efficacy and Safety of Blinatumomab in Adult Patients with B-Cell Acute Lymphoblastic Leukemia
Ya-Lei HU ; Yong-Feng SU ; Yang LI ; Xuan ZHENG ; An WANG ; Yi-Zhi WANG ; Lei XU ; Chun-Ji GAO ; Liang-Ding HU ; Dai-Hong LIU ; Xiao-Ning GAO
Journal of Experimental Hematology 2025;33(6):1571-1576
Objective:To evaluate the efficacy and safety of blinatumomab in adult patients with relapsed/refractory(R/R)or measurable residual disease(MRD)positive B-cell acute lymphoblastic leukemia(B-ALL)in the real world.Methods:The clinical data of 30 B-ALL patients received at least 1 course of blinatumomab therapy in the Chinese PLA General Hospital from January 1st,2021 to December 31st,2023 were retrospectively analyzed,including pre-treatment baseline clinical feature,post-treatment complete response(CR),CR with partial hematologic recovery(CRh),CR with incomplete hematologic recovery(CRi),complete MRD response rate,MRD response rate(MRD<10-4),overall survival(OS),and disease-free survival(DFS),as well as drug-related adverse reactions.Results:Among 5 patients who were not assessed 4 were MRD negative and 1 did not receive bone marrow biopsy.In the R/R B-ALL group(13 cases),11 patients achieved CR/CRh/CRi and 10 patients achieved complete MRD response.In MRD+group(12 cases),9 patients achieved overall MRD response and 7 patients achieved complete MRD response.The median follow-up time was 8.4(95%CI:6.3-10.4)months.The median OS was 15.5(95%CI:0.7-30.3)months in the R/R group,while not reached in the MRD+group.The median DFS of the two groups were not reached.Drug-related adverse reactions occurred in 22 patients,and pyrexia was the most common(13 cases).Grade ≥3 adverse reactions occurred in 15 patients,and neutropenia was the most common(9 cases).Cytokine release syndrome occurred in 6 patients,including 5 cases with grade 1 and 1 case with grade 3.No patients interrupted therapy or died due to drug-related adverse reactions.Conclusion:Blinatumomab is effective in the treatment of R/R or continuous MRD+B-ALL with acceptable adverse reactions.
4.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
5.The evolution of ventricular assist devices and future perspectives
Sheng-hua LI ; Mei LIU ; Han-luo LI ; Ya-lan LEI ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(3):170-175
Ventricular assist devices(VADs)have emerged as a pivotal therapeutic option for end-stage heart failure,undergoing significant technological advancements from pneumatic membrane pumps to continuous-flow centrifugal pumps.This review provides a detailed overview of several VAD models,including HeartMate Ⅲ,EVAHEART 2,and Heart Con.The initial generation of VADs established a foundation for subsequent developments,despite the occurrence of frequent complications.The second generation of VADs demonstrated a notable improvement in patient prognosis but carried the risk of ventricular collapse.The third generation of VADs represents a further reduction in size,incorporating magnetic levitation technology to enhance durability and blood compatibility.In the future,the development of VADs will focus on better emulating the physiological function of the native heart,improving pulsatility,and extending device longevity.As technology advances,VADs are expected to offer heart failure patients with a greater range of treatment options and a higher quality of life.
6.Design and performance verification of high altitude adaptive oxygen generator
Bo WANG ; Xiao-feng LIU ; Wen-jia LIU ; Yi LI ; Ya-nan WU ; Shu-jie CUI ; Wei ZHANG
Chinese Medical Equipment Journal 2025;46(4):29-34
Objective To design a high altitude adaptive oxygen generator for the crews to alleviate their high altitude reaction in high altitude environment and meet their requirements for oxygen supply.Methods A high altitude adaptive oxygen generator based on the mature pressure swing adsorption oxygen production method was designed with the key technologies of discharge capacity compensation of air compression pump and airway fusion of molecular sieve tower,which had the components of molecular sieve tower,air compression pump,controller,cooling fan,cooler,solenoid valve,regulator,flow meter and etc.Trials were carried out at the simulated altitude and field plateau environment so as to verify the high altitude adaptive performance of the oxygen generator developed.Results The trial results showed the oxygen generator met the desired objectives and the requirements for oxygen volume fraction in GJB 2799-1996 General specification for medical oxygen generator using molecular sieve method.Conclusion The oxygen generartor provides oxygen supply effectively for vehicle operators in plateau environments or the ones rushing into the plateau.[Chinese Medical Equipment Journal,2025,46(4):29-34]
7.Research on the construction of evaluation index system for Huimin Insurance:Based on entropy weight TOPSIS method
Yang LIU ; Min-jiang GUO ; Ya-zi LI ; Xiao-juan ZHANG
Chinese Journal of Health Policy 2025;18(2):1-7
Objective:To build an evaluation index system for Huimin Insurance and provide reference for promoting the steady and sustainable development of Huimin Insurance.Methods:The evaluation indicators were initially constructed through literature analysis method and further revised and improved.The entropy weight TOPSIS method was used to evaluate and analyze 84 Huimin Insurance products with complete evaluation indicator data in 21 provinces across the country.Results:The constructed evaluation index system for Huimin Insurance includes 4 first-level indicators,10 second-level indicators and 28 third-level indicators.The weights of the first-level indicators,from high to low,are the sustainability indicator of Huimin Insurance(0.335 0),the guarantee ability indicator(0.235 1),the fairness indicator of participation in insurance(0.229 9)and the guarantee level indicator(0.200 0).The evaluation results show that the top ranked products are mainly concentrated in Zhejiang and Guangdong.Conclusion:The evaluation results of the entropy weight TOPSIS method are suitable for the comprehensive evaluation of Huimin Insurance and are comprehensive and scientific.They can be used to evaluate the operation and development of Huimin Insurance products,laying a good foundation for further evaluation of the sustainability of Huimin Insurance.
8.Effect of fasting blood glucose on coronary fractional flow reserve in patients with borderline coronary artery disease
Yi-wen ZHANG ; Ya-dong LIU ; Meng-xiao WANG ; Yi-ru WANG ; Yun-peng YANG ; Yun-fang SU ; Ji-xin ZHI
Chinese Journal of Interventional Cardiology 2025;33(5):272-277
Objective To explore the correlation between fasting blood glucose(FBG)level and fractional flow reserve(FFR)in patients with borderline coronary artery disease,and to clarify its potential influence on FFR measurement.Methods From August 2020 to August 2023,the data of 135 patients with coronary atherosclerotic heart disease who received coronary angiography and FFR evaluation in the Fourth Affiliated Hospital of Harbin Medical University were retrospectively collected.According to the exclusion and inclusion criteria,85 cases of borderline diseased vessels of single coronary artery with stenosis degree of 50%-80%were screened out,and they were divided into FBG≥6.1 mmol/L group(47 cases)and FBG<6.1 mmol/L group(38 cases).The baseline data,angiographic and functional indexes of the two groups were compared,and the correlation between FBG and FFR was analyzed.Results Compared with the FBG<6.1 mmol/L group,the FBG≥6.1 mmol/L group had a higher proportion of FFR negative results(72.3%vs.23.7%,P<0.001),and the FFR measurement values were generally increased[0.84(0.80,0.90)vs.0.75(0.68,0.80),P<0.001],with statistically significant differences.Pearson correlation analysis was performed on all lesions,and FFR>0.80(negative result)was positively correlated with FBG≥6.1 mmol/L(r=0.484,P<0.001).Conclusions Among the patients with borderline coronary artery disease(50%-80%stenosis)included in this study,FBG≥6.1 mmol/L is significantly correlated with FFR>0.80.For patients with borderline coronary lesions with elevated FBG,the influence of blood glucose factors should be carefully considered in clinical interpretation of FFR results.
9.Application of mechanical circulatory support devices in heart failure
Ya-lan LEI ; Mei LIU ; Han-luo LI ; Sheng-hua LI ; Xiao-ke SHANG
Chinese Journal of Interventional Cardiology 2025;33(5):288-294
Following extensive interdisciplinary research and development over several years,mechanical circulatory support devices(MCSD),including ventricular assist device(VAD)and total artificial heart(TAH),are now established as vital treatment options for patients with advanced heart failure.These devices have proven to be crucial in assisting or replacing a failing heart,offering patients a new lease of life and improving their quality of life.Currently,mechanical circulatory support(MCS)has become a well-recognised,long-term treatment option for patients who are unable to undergo heart transplantation due to donor organ shortages or contraindications.Given their continuous availability independent of donor organ limitations,these devices are poised to play an increasingly vital role in the future of medicine.This article aims to summarize the evolution,clinical applications,categorization,and potential complications of MCSD.
10.Analysis of dosimetric verification results of intensity-modulated radiotherapy for breast cancer based on EPID fraction images
Xiao-hui WU ; Ya-zheng CHEN ; Zu-wen YAO ; Rui LIU ; Yang LIU ; Xiao-hua WANG
Chinese Medical Equipment Journal 2025;46(6):54-58
Objective To investigate the stability and reproducibility of the treatment fractions during the intensity-modulated radiotherapy(IMRT)for breast cancer and the effect of respiratory motion on the dose irradiation of breast cancer radiotherapy by comparing the results of breast cancer dosimetric verification based on fractionated images by an electronic portal imaging device(EPID).Methods A total of 28 IMRT patients admitted to some hospital from January to June 2023 were grouped according to the pathological results and effects of respiratory motion on the accuracy of radiotherapy during clinical treatment,including 14 cases in a breast group and 14 cases in a non-breast group with 8 ones of head and neck tumors,5 ones of esophageal cancer and 1 case of cervical cancer.All the patients underwent a scan with cone beam computed tomography(CBCT)before the first radiotherapy,and image registration was carried out with a positioning CT.An EPID was used to acquire transmission dose images of 10 fractions of radiotherapy,and γ analysis was performed using the RIT 113 QA software to compare the images of the subsequent 9 fractions with those of the first fraction,with the images of the first fraction of radiotherapy as the baseline values.Absolute maximum dose normalization was implemented under the condition of 10%dose assessment threshold,and the γ-pass rates under the 3 criteria of 2%/2 mm,3%/2 mm and 3%/3 mm were counted separately.The fraction dose verification results of the 28 patients were divided into 3 treatment phases of 2-4 times(T1),5-7 times(T2)and 8-10 times(T3)to analyze the stability of dose irradiation during the radiotherapy.SPSS 22.0 software was used for statistical analysis.Results Under the condition of 10%dose assessment threshold,the breast and non-breast groups had the γ-pass rates being(95.80±2.65)%and(94.60±6.59)%under the 2%/2 mm criterion and(98.46±1.31)%and(97.50±3.30)%under the 3%/2 mm criterion respectively,and the differences were statistically significant(all P<0.05).Under the assessment criteria of 2%/2 mm,3%/2 mm and 3%/3 mm,the breast group had the γ-pass rates of fractions of treatment significantly lower than those of the non-breast group(all P<0.05),while the γ-pass rates showed no significant differences at T1,T2 and T3 treatment phases(all P>0.05).Conclusion EPID fraction images contribute to evaluating IMRT accuracy effectively.IMRT has high stability and reproducibility during the treatment cycle,while respiration may result in dose deviation during the fraction radiotherapy for breast cancer,and optical surface tracking technology or active breathing control technology is suggested to be involved in to relieve dose deviation.[Chinese Medical Equipment Journal,2025,46(6):54-58]

Result Analysis
Print
Save
E-mail